GEL LEAd Acid BAttErY c 12V-24Ah - All

Transcription

GEL LEAd Acid BAttErY c 12V-24Ah - All
Battery specification / Fiche technique
Part No: AMP90100
GEL lead acid BatterY
C 12V-24Ah
gel
gel
CYCLIC
deep
cycle
MAIN INFORMATION / INFORMATIONS GéNéRALES
BRAND / MARQUENX
TECHNOLOGY / TECHNOLOGIE
GEL Lead Acid
NOMINAL VOLTAGE / TENSION NOMINALE 12V
Nominal Capacity / Capacité nominale 24Ah (20hr)
DIMENSIONS ( ± 2 mm) / DIMENSIONS ( ± 2 mm)
• Length / Longueur 166mm ± 1mm (6.54 inches)
• Width / Largeur
175mm ± 1mm (6.93 inches)
• Height / Hauteur
125mm ± 1mm (4.92 inches)
• Total height with terminals / Hauteur totale (avec cosses)
125mm ± 1mm (4.92 inches)
weight ( ± 2 %) / Poids ( ± 2 %)
Approx.8.7 kg (19.18 lbs)
terminaL / type de cosses T12
CASING / Type de Bac
UL94 HB (Standard ABS)
color / couleur de bac
Grey top and grey case
TECHNICAL INFORMATION / INFORMATIONS TECHNIQUES
CAPACITY / CAPACITé
24.0 Ah /1.20A (20hr,1.80V/cell,25°C/77°F)
22.1 Ah / 2.21A (10hr,1.80V/cell,25°C/77°F)
19.75 Ah / 3.95A (5hr,1.75V/cell,25°C/77°F)
17.28 Ah / 5.76A (3hr,1.75V/cell,25°C/77°F)
14.5 Ah / 14.5A (1hr,1.60V/cell,25°C/77°F)
MAX DISCHARGE CURRENT / cOURANT DE DéCHARGE
240A (5s)
internal resistance / résistance interne Approx 15.8mΩ
OPERATING TEMPERATURE RANGE / plage de température
-15°~50°C (5 ~122°F)
Nominal operating temperature / température d’utilisation 25 ± 3°C (77 ± 5°F)
Capacity vs temperature / capacité selon la température
40°C (104°F) 102%
25°C (77°F) 100%
n T12 / Terminal
Unité : mm / Unit: inches
0°C (32°F) 85%
APPLICATIONS
Electric tools / Outils électriques
Vehicles / Véhicules
Lawn mowers / Tondeuses à gazon
Wheelchairs / Fauteuils roulants
Railway and marine systems / Infrastructures marines et ferroviaires
Electric toys / Jouets électriques
Golf trolleys and golf carts / Charriots et voiturettes de golf
Medical equipment / Medical www.enix-energies.com • Date : 14-10-2014 • Rev.No : A1
l 1/2
OUTLINE SAFETYWARNING:USE ONLYWITHINTHEALLOWED PARAMETERS.Do not short circuit or over-load the battery.Charge only using an approved charger designed specifically to charge this battery.Do not heat above maximum temperatures indicated.Never crush,mutilate,puncture or abuse the battery.
Do not dismantle the pack or disable any of the protective devices or circuits. DO NOT USE THE BATTERY IF YOU SUSPECT IT MAY BE FAULTY OR DAMAGED.
© Copyright Enix Energies 2005. NB: This document and the product design are the intellectual property of Enix Energies. No document or design may be copied or used for commercial purposes without written permission of Enix Energies. Users must satisfy themselves, by means of
testing etc, that products are suitable for their application. Data in this document is for general guidance only; consult cell manufacturers data for definitive information. Information is given free of charge and in good faith, but no responsibility can be accepted for any errors or omission
or costs or losses or liabilities arising from the use of this information. All business is conducted to Enix Energies terms and conditions only.
Battery specification / Fiche technique
Part No: AMP90100
Constant current discharge (amperes) at 25°C
table de décharge à courant et puissance constants (a) à 25°C
F.V/Temps 10min15min20min30min45min 1h 2h 3h 4h 5h 6h 8h 10h 20h
1.85V/cell 28.123.621.217.013.110.96.81 5.164.253.643.152.51 2.131.17
1.80V/cell 33.327.624.219.014.411.97.33 5.524.523.833.302.61 2.211.20
1.75V/cell 38.331.027.020.615.512.77.70 5.764.683.953.402.69 2.261.22
1.70V/cell 43.334.329.222.016.413.38.06 5.954.814.063.502.75 2.301.24
1.65V/cell 46.536.330.823.017.013.88.30 6.134.934.143.562.79 2.331.25
1.60V/cell 50.739.132.924.418.014.58.57 6.325.084.253.642.85 2.371.26
CONSTANT POWER DISCHARGE (WATTS) at 25°C
décharge à puissance constante (watts) à 25°C
F.V/Temps 1.85V/cell 1.80V/cell 1.75V/cell 1.70V/cell 1.65V/cell 1.60V/cell 10min15min20min30min45min 1h 2h 3h 4h 5h 6h 8h 10h 20h
52.844.540.232.525.321.213.3 10.18.347.166.214.97 4.232.33
61.451.345.536.027.623.014.2 10.78.827.496.485.17 4.382.38
69.857.050.238.729.524.314.9 11.29.107.726.665.31 4.482.42
77.862.453.841.130.925.415.5 11.59.337.916.845.42 4.562.45
82.265.156.242.632.026.215.9 11.89.538.056.945.49 4.612.48
88.168.959.344.733.527.416.3 12.19.808.247.085.58 4.682.50
Discharge Characteristics
caractéristiques de décharge
Float Charging Characteristics
Caractéristiques de charge en floating
Charging Characteristics
Charge
Volume
0
Temperature 25 C
13.0
%
120
Charged
Voltage
Charging
Current
(A)
(V/cell)
Charge At 0.15C Amp initial charging current and 2.4V/Cell Constant
o
Voltage at 25C
12.0
0.1C
100
Terminal Voltage(V)
11.0
10.0
1C
2C
9.0
0.6C
0.1C
0.2C
0.4C
0.05C
C=C 2 0
2
4
6 8 10
min
20
80
0.08C
2.4
60
0.06C
2.3
40
0.04C
2.2
20
0.02C
2.1
40
4
2
60
6
H
8
10
0C
20
Discharge Time
Temperature Effects in Relation to Battery Capacity
effet de la température sur la batterie
0
After 100% Discharge
Charging Current
(initial at 0.1c Amp)
4
8
12
16
20
Charging Time(hours)
28
24
Effect of Temperature on Long Term Float Life
effet de la température sur la durée de vie en floating
110
Acc.to IEC 896-2 (25
100
0
C / 77 0F)
90
100
80
Extracted capacity in %
90
Available capacity / %
Charge Voltage
(Constant 2.45v/cell)
After 50% Discharge
8.0
1
Charged Volume
2.5
80
70
60
C20
C10
C5
C3
C1
50
40
70
60
50
40
30
20
10
30
-20
-15
-10
-5
5
0
10
15
20
25
30
400
800
1200
Battery temperature/
1600
2000
2400
2800
3200
3600
4000
Number of Cycles
Cycle Life in Relation to Depth of Discharge
cycle de vie en fonction de la profondeur de la décharge
100
10 0C
A
Remaining Capacity(%)
80
25 0C
60
30 C
40 C
40
C
20
0
B
0
0
0
2
4
6
10
8
12
Storage Time(Months)
www.enix-energies.com • Date : 14-10-2014 • Rev.No : A1
l 2/2
OUTLINE SAFETYWARNING:USE ONLYWITHINTHEALLOWED PARAMETERS.Do not short circuit or over-load the battery.Charge only using an approved charger designed specifically to charge this battery.Do not heat above maximum temperatures indicated.Never crush,mutilate,puncture or abuse the battery.
Do not dismantle the pack or disable any of the protective devices or circuits. DO NOT USE THE BATTERY IF YOU SUSPECT IT MAY BE FAULTY OR DAMAGED.
© Copyright Enix Energies 2005. NB: This document and the product design are the intellectual property of Enix Energies. No document or design may be copied or used for commercial purposes without written permission of Enix Energies. Users must satisfy themselves, by means of
testing etc, that products are suitable for their application. Data in this document is for general guidance only; consult cell manufacturers data for definitive information. Information is given free of charge and in good faith, but no responsibility can be accepted for any errors or omission
or costs or losses or liabilities arising from the use of this information. All business is conducted to Enix Energies terms and conditions only.

Documents pareils

PG Range PG-12v30 - Power

PG Range PG-12v30 - Power (12yr Design Life in Float Service at 20ºC) Dimensions (mm)

Plus en détail