6 Wire Contact Wiring Guide
Product designed to meet the requirements of EN 50131-2-6:2008 Grade 2 and Environmental Class III.
Suitable for use in systems designed to comply with PD6662:2010
6 Wire Contact with built in resistors for use in Fully Supervised Loop standard Double Pole systems, using
Single or Multiple doors. See colour code chart below for matching Contact resistors to your Control Panel.
Contact / Control Panel Colour Codes Spectrum Range
This table details the Contact colour coding system used to associate a Contact with the correct value
resistors for your chosen Control Panel. The colour code is a suffix to the Contact product code. For
example 6RSA-RD denotes a Red Contact with 4K7 and 2K2 resistors fitted. This table does NOT refer to
WIRE colours; see Contact Wiring below for details of wire colours.
Code
RD
Colour
Red
GN
BL
GY
PU
YL
OR
Green
Blue
Grey
Purple
Yellow
Orange
Resistor Values Connection Mode Control Panel
4k7 / 2k2
Series
ADE, Bosch, Castle, Menvier, Pyronix,
Scantronic, Texecom
1k / 1k
Series
Honeywell
8k2 / 8k2
Parallel
Guardall
4k7 / 4k7
Series
Aritech, Pyronix
6k8 / 4k7
Series
Guardtec
2k2 / 2k2
Series
Bosch, Europlex
5k6 / 5k6
Series
DSC
Note: DO NOT SHORTEN CABLE BEFORE READING THE FOLLOWING PARAGRAPH.
The contact wires have been colour coded using coloured sleeving. The core wires are not
coloured inside the sheath. To shorten the overall cable length, strip the sheath using the rip cord
and slide the sleeves down to the required length. Then cut the cable to the required length ensuring the coloured sleeves remain on the core wires to enable easy installation.
White
White
Red
Yellow
Blue
Black
6 Wire
Contact
Contact can be used in the following formats:
·
Standard double pole - Single and double leaf doors
·
Fully supervised loop - Single leaf door
- Series mode connection
·
Fully supervised loop - Double leaf doors - Series mode connection
·
Fully supervised loop - Single leaf door
- Parallel mode connection
·
Fully supervised loop - Double leaf doors - Parallel mode connection
Technical Support Line + 44 (0) 2392 696638
Elmdene International Ltd
©2012
6 Wire Instruction Sheet
Page 1
-
Figures 1 & 2
Figure 3
Figure 4
Figure 5
Figure 6
PAK300006 Issue 04B Aug 2012
Figure 1
Standard Double Pole Wiring (No resistors) - Single Leaf Door Arrangement
White
To Control
Panel Tamper
Figure 3
Contact Resist
JB
Box
Tamper
White
Black
To Control
Zone Circuit
White
White
Black
Red
Red
Contact 1
Door 1
Colours not shown are not connected
-
Figure 2
Standard Double Pole Wiring (No resistors) - Double Leaf Door Arrangement
Figure 4
Contact Resisto
JB
White
To Control
Panel Tamper
Box
Tamper
White
To Contr
Panel Zo
Black
To Control
Zone Circuit
Red
Red
Black
Red
White
White
Black
White
White
Contact 2
Contact 1
Door 2
Door 1
Colours not shown are not connected
Colours not sho
-
Technical Support Line + 44 (0) 2392 696638
Elmdene International Ltd
©2012
6 Wire Instruction Sheet
Page 2
-
PAK300006 Issue 04B Aug 2012
Technical Support L
Elmdene Int
©2012
rangement
rangement
Figure 3
Contact Resistors + End of Line Resistor (Series) - Single Leaf Door Arrangement
JB
Black
To Control
Panel Zone
Black
Blue
Yellow
Yellow
Red
Contact
Door 1
Colours not shown are not connected
-
Figure 4
Contact Resistors + End of Line Resistor (Series) - Double Leaf Door Arrangement
JB
Black
Box
Tamper
To Control
Panel Zone
Yellow
Yellow
ite
sue 04B Aug 2012
Box
Tamper
Red
Black
Black
Door 1
Door 2
-
Technical Support Line + 44 (0) 2392 696638
Elmdene International Ltd
Blue
Contact
Colours not shown are not connected
©2012
Red
Contact
6 Wire Instruction Sheet
Page 3
-
PAK300006 Issue 04B Aug 2012
Figure 5
Contact Resistor + End of Line Resistor (Parallel) - Single Leaf Door Arrangement
JB
Black
To Control
Panel Zone
Box
Tamper
Yellow
Yellow
Black
Blue
Contact
Door 1
Colours not shown are not connected
-
Figure 6
Contact Resistor + End of Line Resistor (Parallel) - Double Leaf Door Arrangement
JB
Black
To Control
Panel Zone
Red
Box
Tamper
Red
Black
Yellow
Blue
Contact
Contact
Door 1
Door 2
Black
Colours not shown are not connected
-
Technical Support Line + 44 (0) 2392 696638
Elmdene International Ltd
©2012
6 Wire Instruction Sheet
Page 4
-
PAK300006 Issue 04B Aug 2012
Elmdene International Ltd
(Tel: +44(0)23 9269 6638
3 Keel Close, Interchange Park,
6Fax: +44(0)23 9266 0483
Portsmouth, Hampshire, PO3 5QD, UK üWeb: www.elmdene.co.uk
Pour tous les contacts ELMDENE PARAMÉTRABLE:6yyy-xxx-xx-2R-Ra/Rb
Ra et Rb pour les produits équipés de résistances de fin de ligne dont la valeur
dépend de la centrale
Configuration 1: Autoprotection et alarme en mode "boucle sèche"
Raccordement à la
centrale
Alarme
Rouge
Autoprotecti
on
Noir
Vert
Blanc
Résistance de boucle
Porte
autoprotection
Fermée
Pontet
Porte
Ouverte
Aucun
Circuit ouvert
Circuit fermé
-
Aucun
Circuit fermé
Circuit fermé
Circuit ouvert
Configuration 2: Alarme "Fin de Ligne"; autoprotection "boucle sèche"
Raccordement à la
centrale
Alarme
Rouge
Autoprotecti
on
Noir
Vert
Blanc
Résistance de boucle
Porte
autoprotection
Fermée
Pontet
Porte
Ouverte
Rouge
Bleu
Ra
Circuit fermé
-
Circuit fermé
Circuit fermé
Circuit ouvert
Configuration 3: Boucle commune à 2 résistances séries en fin de ligne
Raccordement à la
centrale
Boucle
Jaune
Blanc
Pontet
Rouge
Bleu
Noir
Vert
Porte
Ouverte
Ra + Rb
Résistance de boucle
Porte
autoprotection
Fermée
Rb
Circuit ouvert
Configuration 4: Boucle commune à 2 résistances parallèles en fin de ligne
Raccordement à la
centrale
Boucle
Jaune
Blanc
Pontet
Jaune
Bleu
Noir
Vert
Technical Support Line + 44 (0) 2392 739412
Porte
Ouverte
Ra
Résistance de boucle
Porte
autoprotection
Fermée
Ra x Rb
Ra + Rb
PAK300006_Fr
Circuit ouvert
Mar 2005 - Issue 03B
Elmdene International Ltd
Tel: +44(0)23 9269 6638
3 Keel Close, Interchange Park,
Fax: +44(0)23 9266 0483
Portsmouth, Hampshire, PO3 5QD, UK ÞWeb: www.elmdene.co.uk
Voor alle Elmdene Universele Contacten: 6yyy-xxx-xx-2R-Ra/Rb
Ra en Rb zijn de einde lijn weerstanden (waarde is afhankelijk van type)
Configuratie 1: Enkel alarm contact en sabotagelus (Geen weerstanden)
Zone aansluitingen
Alarm
Contact
Sabotage
Contact
Doorverbinding
Alarm
Weerstandswaarde
In rust
Sabotage
Rood
Zwart
Geen
open
(oneindig)
gesloten
(0 Ohm)
-
Groen
Wit
Geen
gesloten
(0 Ohm)
gesloten
(0 Ohm)
Open (oneindig)
Configuratie 2: Fully Supervised Loop, Alleen alarm weerstand
Zone aansluitingen
Alarm
Contact
Sabotage
Contact
Rood
Zwart
Doorverbinding
Rood
Blauw
Groen
Wit
Alarm
Weerstandswaarde
In rust
Sabotage
Ra
gesloten
(0 Ohm)
-
gesloten
(0 Ohm)
gesloten
(0 Ohm)
open (oneindig)
Configuratie 3: Fully Supervised Loop, Weerstanden in “serie aansluiting”
Zone aansluitingen
FSL
Geel
Wit
Doorverbinding
Rood
Blauw
Zwart
Groen
Alarm
Ra + Rb
Weerstandswaarde
In rust
Sabotage
Rb
open (oneindig)
Configuratie 4: Fully Supervised Loop, Weerstanden in “paralllel aansluiting”
Zone aansluitingen
FSL
Geel
Wit
Doorverbinding
Geel
Blauw
Zwart
Groen
Technical Support Line + 44 (0) 2392 696638
Alarm
Ra
Weerstandswaarde
In rust
Sabotage
Ra x Rb
Ra + Rb
open (oneindig)
PAK300006_NL May 2005 - Issue 03B