Data Sheet (English)
Transcription
Data Sheet (English)
Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-4 ■ A special software (function module) for integration in PLC systems is not required. ■ Cable max. 50 m between interface and read/write head ■ 2 decimal rotary coding switches for the adjustment of the Profibus address ■ Maximum transmission rate to the fieldbus 12 Mbps ■ Sub-D female, 9-pin, for fieldbus connection ■ Screw terminals for voltage supply ■ LEDs for display of supply voltage, group and bus errors as well as status and diagnostics TI-BL20-DPV1-S-4 1545075 4 85.1 x 128.9 x 74.4 mm Rated voltage from the supply terminal Supply voltage System power supply Field supply Admissible range Max. field supply current Max. system supply current 24 VDC 24 VDC 24 VDC / 5 VDC 24 VDC 18…30 VDC 10 1.2 Fieldbus transmission rate Fieldbus address range Fieldbus addressing Service Interface Fieldbus connection technology Voltage supply connection Fieldbus termination 9.6 kbps … 12 Mbps 1...99 2 rotary switches PS/2 socket 1 x female sub-D connector screw terminals external Transmission rate Cable length Electrical isolation 115.2 kbps 50 m isolation of electronics and field level via optocouplers Connection technology screw, tension spring Sensor supply 0.25 A per channel, short-circuit proof Number of diagnostics bytes Number of diagnostics bytes Number of parameter bytes Number of parameter bytes Number of input bytes Number of output bytes 4 3 8 5 24 24 ■ Connection of up to 4 read/write heads via BL ident extension cables ■ Mixed operation of HF and UHF read/ write heads Edition • 2016-11-03T07:20:49+01:00 Type designation Ident no. Number of channels Dimensions (W x L x H) 1/7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-4 Operating temperature Storage temperature Relative humidity Vibration test Shock test Drop and topple Electro-magnetic compatibility Protection class included in delivery 0…+55 °C Field/System Supply -25…+85 °C 5 to 95% (internal), Level RH-2, no condensation (at 45 °C storage) acc. to EN 61131 acc. to IEC 68-2-27 acc. to IEC 68-2-31 and free fall to IEC 68-2-32 acc. to EN 50,082-2 IP20 2 x end brackets BL20-WEW-35/2-SW, 1 x end plate BL20-ABPL Functional principle The BL ident® system can be installed in many different ways. Various fieldbus standards, such as PROFIBUS-DP, EtherNet/IP, Ethernet Modbus TCP, EtherCAT, DeviceNet, CANopen and PROFINET IO allow flexible integration. BL ident® simple electronic modules (BL20-2RFID-S, BL67-2RFID-S) can be integrated in existing control or host systems without function block, since standard input/output process data is used for communication. Programmable gateways with peripheral preprocessing function relieve the control system and fieldbus level. Edition • 2016-11-03T07:20:49+01:00 Preassembled sets (2, 4, 6 or 8-port), easily mounted, available for all fieldbus networks. 2/7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-4 Anschlussübersicht Power Supply The U system supply feeds power to the gateway and the I/O modules. The U field supply feeds power to the sensors and actuators. SYS L Edition • 2016-11-03T07:20:49+01:00 PROFIBUS-DP Fieldbus cable (example): D9T451-2M (ident no. 6915759) or RSSW-D9T451-2M (ident no. 6915779) 3/7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-4 Compatible base modules Type Pin configuration BL20-S4T-SBBS 6827046 Tension spring connection …/S2500 Connectors BL20-S4S-SBBS 6827047 Screw connection …/S2501 Connectors Edition • 2016-11-03T07:20:49+01:00 Connectors …/S2503 4/7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-4 LED display LED D Color RED RED RW0 / RW1 FLASHING (0.5 Hz) OFF ON FLASHING (2 Hz) ON FLASHING (2 Hz) Meaning Error report or diagnostics active. Failure of MODBUS communication Check if more than 2 adjacent electronic modules are pulled. Relevant modules are located between gateway and this module. Upcoming module diagnostics No tag, diagnostics disabled Tag available Data exchange with tag enabled Read/write head fault Short-circuit in the supply line of read/write head Edition • 2016-11-03T07:20:49+01:00 GREEN GREEN RED RED Status OFF ON 5/7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-4 I/O Data Mapping Channel 0 Channel 1 OUTPUT Channel 0 DONE BUSY Error Code Error Code 1 Reserved READ DATA (8 Byte) ERROR XCVR CON XCVR ON TP TFR Reserved DONE BUSY Error Code Error Code 1 Reserved READ DATA (8 Byte) ERROR XCVR CON XCVR ON TP TFR Reserved Bit 7 XCVR Reserved Bit 5 TAG ID Bit 4 READ Bit 3 WRITE Bit 2 TAG INFO Byte Count 2 Bit 1 XCVR INFO Byte Count 1 Bit 0 RESET Byte Count 0 m+2 m+3 m+4 m+5 … m+10 m+11 m+12 m+13 Address high byte Address low byte WRITE DATA (8 Byte) TAG ID READ WRITE TAG INFO XCVR INFO RESET Byte Count Byte Count Byte Count 2 1 0 m+14 m+15 m+16 m+17 … m+22 m+23 Address high byte Address low byte WRITE DATA (8 Byte) XCVR Reserved Bit 6 NEXT NEXT Edition • 2016-11-03T07:20:49+01:00 Channel 1 n n+1 n+2 n+3 n+4 n+5 … n+10 n+11 n+12 n+13 n+14 n+15 n+16 n+17 … n+22 n+23 BYTE m m+1 6/7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-4 Accessories Type code Ident no. Description FW-D9TLEDKU9PGW-FC-ME-SH-8,5 6604220 PROFIBUS-DP field-wireable 9-pin Sub-D connector, male/female, angled, insulation displacement contact, metal housing, 12 Mbps, switchable terminating resistor FW-D9TLEDKU9XX-G- 6604221 FC-ME-SH-8,5 PROFIBUS-DP field-wireable 9-pin Sub-D male, straight, cutting clamp contact, metal housing, 12 Mbps, switchable terminating resistor I/O-ASSISTANT-KABEL-BL20/BL67 RS232 service cable for Gateways with PS2 interface 6827133 Shield terminal and strain relief for bus cable Edition • 2016-11-03T07:20:49+01:00 BS3511/KLBUE4-31.5 6827342 7/7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com