CIATRONIC System
Transcription
CIATRONIC System
t r o f m o c l CIATRONIC System Ultimate precision air-conditioning u n i v e r s a A i r co n d i t i o n i n g ca b i n e t s NA 05.93 A > CIATRONIC > CIAT, System Precision air- European leader in air-conditioning CIAT's unique expertise is backed up by over 70 years experience, including 30 years in computer cabinets. With 9 production sites around the world and representatives in more than 70 countries, CIAT is a choice partner. Our air handling division already has over 150,000 appliances in service in Europe. Backed up by this experience and our R&D potential, we offer solutions that satisfy the specific requirements of precision air-conditioning. > > AT THE FOREFRONT of technology CIAT's European research centre, based at Culoz in France, spearheads its development and production efforts, creating the latest technologies in order to guarantee optimum heating and ventilation performance. Our test laboratory has gained world-wide recognition for its leading edge studies on fluids and energy optimisation. CIAT's production quality and its management of the logistics chain from supplier to final client are managed by supply chain software that optimises production time. For our clients, this industrial production also guarantees constant quality of both our products and the information provided. > A PARTNER in your precision Our know-how focuses specifically on satisfying the most exacting demands for temperature and humidity control. Our patented CIAT regulation PLCs, “air-control®” systems that adapts air flows to thermal loads in premises, and high filtration Opacimetric (F7) and Hepa (H13) devices provide the highest performances on the market. In addition, the eco-design of our filter technology anticipates environmental standards in this area. -c onditioning r-c > EXPERTISE in high security To protect your installations, we offer you the highest security thanks to full control from design to installation. CIAT's worldwide sales network distributes our products and ensures their maintenance, providing acknowledged reliability. Safety and troubleshooting devices are standard in our cabinets, in both the air-conditioning and cooling parts. The regulation automatons make it possible to switch from rotation, emergency and assistance modes between cabinets via a communication bus. The twin coil function is a chilled water and direct expansion battery installed in the same cabinet that guarantees emergency backup in case the chilled water circuit fails. > > REFERENCES in High - Tech Telecommunications SFR, France Télécom, LD Com, Belgacom, Mobilcom, T System, Algeria Télécom, Télécom Nepal Information Systems IBM, Michelin, Total Ministry of Finance, Alcatel, Process engineering / Metrics / Storage of sensitive products Emin Leydier, Canal +, Stade de France, Musée du Petit Palais > CIATRONIC System The r ange Micro 2000 Performance and simplicity Flow rate: 1 000 to 2 000 m3/h Output: 5 to 10 kW > Temperature and humidity control > Chilled water or direct air expansion > More compact > Short delivery times > Optimisation of cost / performance ratio Company computer room e perf ormanc e Magister 2 Exacting performance > Flow rate: 3 000 to24 000 m3/h Output: 10 to 100 kW Expair Performance and efficiency Flow rate: 2 000 to 12 000 m3/h Output: 10 to 50 kW > Temperature and humidity control > Chilled water or direct air expansion > Numerous options > Competitiveness > Delivery within 3 weeks Computer room, telephone premises (unbundling, BBC) Electric premises Sensitive storage > Temperature and humidity control > Chilled water or direct air expansion with air or water > Numerous adaptations, options and air flows > High energy efficiency > Low sound level > High efficiency filtration > Maximum security for your premises Computer rooms Electric premises Telephone exchanges Industrial applications Hospitals Metrology > >< Micro 2000 P erf ormanc e and simplicity 1 > Easy integration on site Centrifugal fan with direct drive and manual variation for flow/pressure adaptation to air handling network Optimal compactness Communicative control between cabinets and possible connection to CTM (MODBUS / JBUS / LON) 3 > Easy installation and maintenance Connection: - hose kit for hydraulic connection - access to front panel - preloaded external units (direct expansion model) - easy access to connections Handling: aluminium frame and low weight, as compressors are in the external unit Easy extraction of filters 5 > Simplicity and efficiency Associated CONDENCIAT CL condensation units High quality design and finishing High energy output - SCROLL compressor and R410A fluid - speed variation card to adapt the fan to the condenser exchange requirement Installation: external unit capable of being offset by 50 metres from the internal unit > Chilled water models (EG) > Direct air expansion (DDA) >< > Expair P erf ormanc e and efficiency 2 > Fast availability Essential components managed in stock: - panels - batteries / coils - condensation units - humidifiers - filters - electric batteries 4 > Competitiveness and performance Temperature and humidity control Rationalisation of components Double wall panel for better acoustic damping (fire resistance MO) Wide range of options Chilled water, direct expansion and air cooled condensation models > Chilled water models (EG) > Direct air expansion (DDA) > > Chilled water models (EG) > Direct air expansion (DDA) > Direct water expansion (DDE) > Magister 2 P erf ormanc e and e xigency 1 > Energy saving SCROLL compression technology for R410A fluid for maximum energy efficiency (high EER) Installation of the modular deep coil battery to minimise the system effect Plug fan ventilators for better air handling efficiency linked with electronic switching motor (DC voltage variator) for optimal electric output Automatic control: the automaton controls fan speed as a function of the load in the premises 2 > Easier handling and maintenance Rigid cabinet, reinforced frame, double wall panel All internal devices can be accessed via the front panel Direct coupling between the fan and motor Filtration mounted on rails to facilitate handling Communication of controls provides feedback and monitoring of the building 3 > Safety for your installations Master/slave operation Communication with MODBUS / JBUS / LON protocol for real-time information TWIN COIL function for replication of fluid systems F7 filtration at air intake, H13 on air discharge Double wall insulation with compressed 25 mm thick rock wool: fire resistance MO CIAT synergy: air or water cooled condenser manufactured by CIAT for perfect control of the entire unit 4 > Adaptation and precision Temperature and humidity control Acoustic level reduced by - A double wall insulation - Low noise plug fan - Optimised aeraulics: reduced system effect air speed less than 2.5 m/s Design: fits perfectly in its environment Compact Continuous air filtration Different batteries can be chosen as a function of site conditions Adjustment of air-flow as a function of air intake temperature Adjustment of fan speed to offset filter clogging and preserve constant flow rate Set point stability thanks to the use of control automatons (PI or PID) and regulation valve (progressive) > Everything you need to know about the Technol ogic al choic es / Design / Options Application PERFORMANCE FILTRATION FAN HUMIDITY CONTROL (option) HEATING COIL (option) MICRO 2000 EXPAIR MAGISTER 2 Flow rate range (m3/h) 1 000 to 2 000 2 000 to 12 000 3 000 to 24 000 MODEL AVAILABLE The name of the model corresponds to its nominal output 2 000 4 000 / 6 000 8 000 / 12 000 3 000 / 6 000 8 000 / 12 000 16 000 / 20 000 24 000 Power range (kW) 5 to 10 10 to 45 15 to 100 Filtration (air intake) G4 G4 / F7 G4 / F7 or G4 + F7 CONSTRUCTION REFRIGERANT CIRCUIT OPTIONS 4 rows 3 to 6 rows according to wat. temp. 5 rows Direct expansion coil Double coil EG+EG, EG+DD Condensate drain pan 4 rows of copper plated with aluminium finned tubes / Galvanized steel Galvanized steel 3 rows 3 + 3 rows Stainless steel Fan Direct drive electric centrifugal fan Flow rate adjustment (standard pressure) Voltage variator (option) Direct drive electric plug fan Motor with electronic switching (DC) variation from a set point of 0.10 V Humidifier Electrode Humidifier control Progressive Dehumidification Hot water coil Electric battery regulation Option Not available Stainless steel shielded element Electric battery regulation 1 stage Assemblies available 1 SI / 3 SD Direct air expansion model (DDA) Direct water expansion model (DDE) CONTROL H10 / H13 Final filtration (additional box) Chilled water models (EG) CONFIGURATION Industry, telecom, hospitals, etc. Model Chilled water coil COLD BATTERY Tertiary, computer room premises, etc. Option Low inertia shielded element 2 stages or TRIAC 1 SI 3 / 4 / 5 SD 1 / 2 SI 3 / 4 /5 SD Water coil controlled by Water coil controlled by progressive 3-way valves progressive 2 or 3-way valves Cabinet linked to a CIAT Condenciat Cabinet linked to a type condensation unit CIAT AIRIAL type air (compressor outside cabinet) cooled condenser (compressor inside cabinet) Plate condenser built into the cabinet + pressostatic valve (compressor inside cabinet) Control CIAT µair connect CIAT µair connect CAREL pCO3 CIAT µair connect CAREL pCO3 Protocol MODBUS / JBUS MODBUS / JBUS / LON MODBUS / JBUS / LON Master / slave function Display Filter clogging control Air flow control Water leak control YES Text Standard Standard Option YES Text Standard Standard Option YES Text Standard Standard Option Low limit control on discharge Option Option Option Frame Galvanised steel jacket + oven painting Aluminium upright Reinforced frame + aluminium upright Panel Double wall with compressed rock wool (fire resistance MO) Double wall with compressed rock wool (fire resistance MO) Double wall with compressed rock wool (fire resistance MO) Fluid compressor Compressor technology R410A SCROLL R410A SCROLL R410A SCROLL Adjustable support frame YES YES YES Discharge plenum YES YES YES Air intake motorised damper NO YES YES CIATRONIC System As sembly / Air fl o w direction Return air at top Return air at top ! ! Micro 2000 ! Expair ! Magister 2 Magister 2 Air discharge at rear Air discharge at bottom Air discharge at top ! Micro 2000 ! Expair ! Magister 2 Recycling at front Air discharge at top Air discharge at top ! Expair ! Magister ! Expair ! Magister 2 Return air at bottom Return air at rear Range Micro Expair Magister 2 Model 2000 4000 6000 8000 12 000 6000 8000 12 000 16 000 20 000 24 000 8,4 8,9 1 2000 18,1 15,6 1 4000 26 23,9 1 6000 36,2 36,3 2 8000 54 48,1 2 12000 26 27 1 6000 33 34 1 8000 53 52 2 12000 Performance Total output EG model (kW)(1) Total output EG model (kW)(2) Number of refrigerant circuits Rated air flow rate (m3/h) (1) conditions: water 7/12°C - recycled air 24°C 50% - normal flow rate (2) conditions: recycled air 24°C 50% - normal flow rate 65 67 2 16000 92 92 2 20000 105 97 2 24000 2 Non contractual document. With the thought of material improvement always in mind, CIAT reserves the right,without notice, to proceed with any technical modification. Avenue Jean Falconnier - B.P. 14 01350 - Culoz - France Tél. : 33 4 79 42 42 42 Fax : 33 4 79 42 42 10 e-mail : [email protected] - http:\\www.ciat.com Compagnie Industrielle d’A Applications Thermiques - S.A. with a registered capital of 26 000 000 € - R.C.S. Belley B 545 620 114