CPF-38 Lennox Peninsula
Transcription
CPF-38 Lennox Peninsula
MERIT™ SERIES CPF-38 Appliance Specifications 12 ¹⁄₂" (318 mm) 12 ¹⁄₂" (318 mm) 10 ¹⁄₂" (267 mm) 5 ¹⁄₄" (133 mm) 48 ³⁄₄" (1238 mm) 48 ³⁄₄" (1238 mm) 32" (813 mm) 42 ¹⁄₂" (1080 mm) Combustion Air 21" (533 mm) 3 ⁷⁄₈" (98 mm) 5 ³⁄₄" (146 mm) 8 ⁹⁄₁₆" (217 mm) 8 ¹³⁄₁₆" (224 mm) 38" (965 mm) 39 ¹⁄₄" (997 mm) End View Front View 23 ¹⁵⁄₁₆" (608 mm) 25 ³⁄₁₆" (640 mm) 8" (203 mm) Model CPF-38 Part Number 052011 Weight 210 lbs. 39 ¹⁄₄" (997 mm) Top View Note: All specifications, ratings and dimensions are subject to change without notice. Fireplace Finishes Mantels And Trim Vertical Surround Limitations Hearth Extensions & Wall Shields Combustible mantels and trim may be installed 12" (305 mm) above the fireplace opening as per NFPA 211; Section 7-2.3.3. and the Mantel limitation diagram. If a mantel is of a noncombustible material, it is exempt from these requirements as long as it does not interfere with the installation or operation of glass doors. Combustible materials may project beyond the sides of the fireplace opening as long as they are kept within the shaded areas illustrated in the diagram below. A hearth extension must be installed with all fireplaces. Its purpose is twofold. It protects a combustible floor in front of the fireplace from both radiant heat and sparks and it distinguishes the prescribed hearth extension area from other non-protected surfaces. Combustible Materials Allowed in Shaded Area 1" (25 mm) 8" (203 mm) Max. 1 ¹⁄₂" (38 mm) Combustible Mantel and Trim 12" (305 mm) Min. Side Wall 8" (203 mm) Min. to Fireplace Opening Spacer 30˚ False Header End Opening Hearth Extension 8" (203 mm) Minimum Distance to Side Wall 25 ³⁄₁₆" Finished Wall 5 ¹⁄₄" (133 mm) C B C Fireplace Opening U.S. Mantel Limitations (See Installation Instructions for Canadian Installation) A Opening Width A - 16" (406 mm) B - 28 ¹⁄₂" (724 mm) C - 8" (203 mm) D - 44 ¹⁄₂" (1130 mm) NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 775,624M Rev. A 04/07 MERIT™ SERIES CPF-38 Framing Specifications Note: All framing dimensions calculated for ¹⁄₂" dry wall at the appliance face. If sheathing the chase or finishing with other thickness materials, calculations will need to be made. Typical Installation Chimney and Termination 49" (1245 mm) End View 42 ³⁄₄" (1086 mm) Framing Dimensions for Roof Right Front View FTF8 at 2" (51 mm) Pitch C D* 0/12 16 ¹⁄₂" (419 mm) 16 ¹⁄₂" (419 mm) 6/12 16 ¹⁄₂" (419 mm) 19" (483 mm) 12/12 16 ¹⁄₂" (419 mm) 23 ¹⁄₂" (597 mm) D C 4 x 4 Header Roof Framing 2x4 False Header (Optional) * Perpendicular to Roof Ridge. Framing Dimensions for Ceiling Ceiling Opening Flue Type A B FTF8, Vertical at 2" (51 mm) 16 ¹⁄₂" (419 mm) 16 ¹⁄₂" (419 mm) FTF8, Offset At 2" (51 mm) 16 ¹⁄₂" (419 mm) *24 ³⁄₁₆" (614 mm) Maximum B 7" Min. (178 mm) 27" (686 mm) *39 ¹⁄₄" (997 mm) Maximum 49" (1245 mm) 42 ³⁄₄" (1086 mm) A Ceiling Framing *Dimensions Calculated For 1/2” Drywall Framing NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 775,624M Rev. A 04/07