the AQUACALC Module SANDRA

Transcription

the AQUACALC Module SANDRA
BDLT-SANDRA
Optimize the monitoring and the management of sewerage
Resolve the
management
issues
of
sewerage
systems
Improve the monitoring and efficiency of your
sewerage systems
Sewer network discharge Self monitoring in order to
answer
regulatory
environment
protection
requirements (French regulation),
SANDRA adresses specific the needs of operating data
management :
Sewerage system permanent diagnosis
o network flow management,
o Sensor status management
Value and share your data
wastewater treatment plants
collection networks
measuring stations (rain gauges, surface water
quality,…)
Thanks to BDLT-SANDRA, you can create advanced
indicators and improve monitoring reports of your
facilities.
Linked to BDLT, SANDRA allows the management of
the entire technical data information chain, from field
sensors to end users. Thanks to SANDRA data valuing
and sharing is enhanced while producing sewerage
systems « smart » monitoring reports
FEATURES
BENEFITS
Automatic processing of large series of urban
hydrology chronological data
Data is gathered in a unique tool for a clear and
jointly agreed vision
Calculation methods dedicated to self-monitoring
and permanent diagnosis
Operations are monitored,
improved continuously
User friendly interface and configuration wizards
for operating teams productivity
Regulatory and customised reports are easily
generated
Dedicated client for mobile users on networks
Capacity to anticipate, act and react is improved
managed
and
Sewerage system operator work is valued
shared and communicated
1
1
© ONDEO SYSTEMS - BDLT V4 - SANDRA
Créé le 20/03/2012 10:27:00
SANDRA FEATURES
Simply generate your reports
Validate your field data
With SANDRA and a Microsoft Excel-based BDLT
reports generator, manage, share and value your data
with simplicity and a high level of customization.
SANDRA includes a set of validation / correction
features of sewerage system data :
Data comparison with trend charts and graphs
Spreadsheets, graphs, and trend charts
Automated validation methods (threshold, variation,
dead band, consistency of the measure with a binary
signal)
Intuitive display of data validity status
Management and display of comments about data
validation processings
Correction
methods
(interpolation,
substitution, manual correction,…)
extension,
Only reliable data is used for report generation.
Raw data is always stored and can be accessed at
every moment
Make advanced dataprocessing
Maps and graphic views
SANDRA includes a lot of data processing methods :
Periodic and pluviometry events
Periodic and irregular sewer network discharges
DO Prairies
Pluviométrie
Hauteur totale précipitée (mm) :
Nombre d'évènements :
Durée totale des précipitations (h) :
Intensité moyenne maximale (mm/h) :
33,3
7
12,8
4,29
Trop-plein du PR Rive Gauche
1
Durée totale de déversement (h) :
3
Volume total déversé (m3) :
0
dont temps sec (m3) :
0%
% de volume déversé :
3
23
Débit de pointe déversé (m /h) :
Dry weather flow
Continuous infiltration of clean water into sewer
network module
PR Rive Gauche
la Seine
Drainage area
Flow calculation methods library
o Triangular weir (Gouley & Grimp,…)
o Rectangular weir (Bazin,…)
o Latéral weir (Dominguez,…)
PR Fonderie
Trop-plein du PR Fonderie
Durée totale de déversement (h) :
Volume total déversé (m3) :
dont temps sec (m3) :
% de volume déversé :
Débit de pointe déversé (m3/h) :
Aval vanne de Normandie
4 953
Débit moyen journalier (m3/j) :
36
Débit d'ECPP* (m3/j) :
18%
% d'ECPP* :
-0,6
Hauteur max de mise en charge (m) :
*ECPP : Eaux Claires Parasites Permanentes
Aval DO Normandie
Durée totale de déversement (h) :
Volume total déversé (m3) :
dont temps sec (m3) :
% de volume déversé :
Débit de pointe déversé (m3/h) :
Rû de l'Etang
Rû de Buzot
Débit moyen journalier (m3/j) :
Débit maximal (m3/j) :
Débit minimal (m3/j) :
1 860
5 207
319
Formula editor
Data sampling methods
ONDEO SYSTEMS
38, Rue du Président Wilson
78230 Le Pecq - France
Tél. +33.1.34.80.53.02
Fax. +33.1.34.80.53.80
[email protected]
2
© ONDEO SYSTEMS - BDLT V4 - SANDRA
20
7 325
663
4%
1 290
Amont du PR Fonderie
7773
Débit moyen journalier (m3/j) :
76
Débit d'ECPP* (m3/j) :
25%
% d'ECPP* :
Hauteur max de mise en charge (m) :
0,15
*ECPP : Eaux Claires Parasites Permanentes
DO Normandie
Rû de Buzot
Aval du PR Rive Gauche
11 753
Débit moyen journalier (m3/j) :
23 452
Débit maximal (m3/j) :
8 606
Débit minimal (m3/j) :
230
Débit d'ECPP* (m3/j) :
47%
% d'ECPP* :
*ECPP : Eaux Claires Parasites Permanentes
www.ondeosystems.com
13
9 209
1 134
4%
9 411

Documents pareils