Weather: Environmental Sound proof
Transcription
Weather: Environmental Sound proof
INDUSTRIAL SOUNDPROOFING – Engineering and Constructions ECIB ensures shelters design with high resistance structure designed for extreme conditions Weather: High range of temperatures from -40 to +50 °C Environmental Strong wing, rains, snow, ice, dust, blast Sound proof High noise level of equipment installed within the shelter 18, rue François Jacob - 62800 LIEVIN Tel: 03 21 13 49 13 – Fax: 03 21 42 22 55 - [email protected] EP 2012.12.01 rev 0 1 PASSIVE FIRE / BLAST ENCLOSURE ECIB developed these products for high-risk sites such as drilling platform, compressing gas, refinery; they mainly protect the sensitive or emergency equipments such as fire pumps. They can force machinery beyond its usual limits in case of fire or accidental explosion, in order to assure the sustainability of the equipment. DESCRIPTION The construction design of fire covers fire classes A and H (hydrocarbon fire) from 0 to 120 minutes H120; it is often associated with the explosion (blast 0.3 to 1 bar). The construction of a reinforced steel structure of high inertia combined with a thick ribbed cladding is developed to resist to blowing load. Calculations and numerical simulations are performed using Pro-Mechanica that enables the deformations visualization. The materials are certified Fire BV as well as single doors or double doors. 4 layer insulation cross assures a high sound insulation. INSTALLATION Ready to install on the frame customer, bonding high strength nuts and bolts. The frame can receive a cladding H60 or H120. CONSTITUTION External steel sheet of high thickness 3 to 4mm S 235, S 355 K2, stainless steel 316L, duplex Rock-wool high-density 150kgs/m3 Undercoating 240µ with OHGPI certification OPTIONS Waterproof enclosure pressurized for area ATEX .System concept for polar temperature. Modules fledged large 18 Rue Francois Jacob 62800 LIEVIN Tel : 03 21 13 49 13 – Fax : 03 21 42 22 55 - [email protected] INDUSTRIAL SOUNDPROOFING – Engineering and Constructions LIST of REFERENCE Refinery plant and offshore site Khariaga(2000) Location:Khariaga field in North Russia Enclosures on generators for caterpillar engines Samotlor field (2002) Location: Urals Federal District, Siberia Enclosure on pumps for Sulzer pumps France Priobskoïe field (2003) Location Urals Federal District, Siberia Enclosure on pumps for Sulzer pumps France The Amenam-Kpono field(2003) Location: eastern part of the Niger Delta Enclosure on fire pumps for Sulzer pumps and caterpillar engines Dalia oil offloading (2004) Location: Gulf of Guinea, offshore Angola Enclosure on boiling pumps for Sulzer pumps France Moho bilondo (2008) Location: Offshore the Republic of the Congo Enclosure on fire pumps for caterpillar engines Pazflor (2005) Location: Gulf of Guinea, Offshore Angola Enclosure on fire pumps for caterpillar engines 18, rue François Jacob - 62800 LIEVIN Tel: 03 21 13 49 13 – Fax: 03 21 42 22 55 - [email protected] 3 2 INDUSTRIAL SOUNDPROOFING – Engineering and Constructions Total E&P Yemen(2007 and 2008) Location: Yemen Enclosure on fire pumps for caterpillar engines Total Ofon phase 2( 2009/2010) Location: Offshore Nigeria 4 Enclosures H 60 blast 0,5 bars on fire pumps for Flowserve pumps Sakhaline Location: Okhotsk sea east Russia 1 Enclosure H60 blast 0,3 bars on fire pumps for Flowserve pumps Total CLOV ( 2011) Location: Gulf of Guinea Offshore Angola 1 Enclosure on generators for caterpillar engines 18, rue François Jacob - 62800 LIEVIN Tel: 03 21 13 49 13 – Fax: 03 21 42 22 55 - [email protected] 3 3 PASSIVE FIRE / BLAST ENCLOSURE ECIB developed these products for high-risk sites such as drilling platform, compressing gas, refinery; they mainly protect the sensitive or emergency equipments such as fire pumps. They can force machinery beyond its usual limits in case of fire or accidental explosion, in order to assure the sustainability of the equipment. DESCRIPTION The construction design of fire covers fire classes A and H (hydrocarbon fire) from 0 to 120 minutes H120; it is often associated with the explosion (blast 0.3 to 1 bar). The construction of a reinforced steel structure of high inertia combined with a thick ribbed cladding is developed to resist to blowing load. Calculations and numerical simulations are performed using Pro-Mechanica that enables the deformations visualization. The materials are certified Fire BV as well as single doors or double doors. 4 layer insulation cross assures a high sound insulation. INSTALLATION Ready to install on the frame customer, bonding high strength nuts and bolts. The frame can receive a cladding H60 or H120. CONSTITUTION External steel sheet of high thickness 3 to 4mm S 235, S 355 K2, stainless steel 316L, duplex Rock-wool high-density 150kgs/m3 Undercoating 240µ with OHGPI certification OPTIONS Waterproof enclosure pressurized for area ATEX .System concept for polar temperature. Modules fledged large 18 Rue Francois Jacob 62800 LIEVIN Tel : 03 21 13 49 13 – Fax : 03 21 42 22 55 - [email protected] INDUSTRIAL SOUNDPROOFING – Engineering and Constructions REFERENCES Raffineries et offshore Khariage (2000) Localisation : Nord Russie Zone Khariaga Enveloppes pour groupes électrogènes pour moteurs CATERPILLAR Champ Samotlor (2002) Localisation : Sibérie – District Fédéral de l’Oural Enveloppe sur pompes SULZER Champ Priobskoïe (2003) Localisation : District Fédéral de l’Oural Enveloppe sur pompes SULZER Champ Amenam-Kpono (2003) Localisation : Est du Delta du Niger Enveloppe sur pompes incendie SULZER et sur moteurs CATERPILLAR Stockage DALIA OIL (2004) Localisation : Golfe de Guinée – Offshore Angola Enveloppe sur pompes à fluide chaud SULZER Pazflor (2005) Localisation : Golfe de Guinée – Offshore Angola Enveloppe sur pompes incendie pour moteurs CATERPILLAR Total E & P Yemen (2007 – 2008) Localisation : Yemen Enveloppe sur pompes incendie pour moteurs CATERPILLAR Moho Bilondo (2008) Localisation : Au large de la République du Congo Enveloppe sur pompes incendie pour moteurs CATERPILLAR 18, rue François Jacob - 62800 LIEVIN Tel: 03 21 13 49 13 – Fax: 03 21 42 22 55 - [email protected] EP 2012.12.01 rev 0 1 INDUSTRIAL SOUNDPROOFING – Engineering and Constructions REFERENCES (suite) Total Ofon –phase 2 (2009 – 2010) Localisation : Au large du Nigéria 4 enveloppes H60 anti-explosion 0,5 bars sur pompes incendie pour pompes FLOWSERVE Sakhaline Localisation : Côte est Russie – Okhotsk 1 enveloppe H60 anti-explosion 0.3 bars sur pompes incendie pour pompes FLOWSERVE Total CLOV (2011) Localisation : Golfe de Guinée – Offshore Angola 1 Enveloppe pour groupe électrogène pour moteur CATERPILLAR 18, rue François Jacob - 62800 LIEVIN Tel: 03 21 13 49 13 – Fax: 03 21 42 22 55 - [email protected] EP 2012.12.01 rev 0 2