DK-6050 - TDK
Transcription
DK-6050 - TDK
Ref. Certif. No. DK-6050 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI D’ACCEPTATION MUTUELLE DE CERTIFICATS D’ESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE CERTIFICAT D’ESSAI OC Product Produit Power Supply Name and address of the applicant Nom et adresse du demandeur TDK-LAMBDA UK LTD KINGSLEY AVE ILFRACOMBE, EX34 8ES United Kingdom Name and address of the manufacturer Nom et adresse du fabricant TDK-LAMBDA UK LTD KINGSLEY AVE ILFRACOMBE, EX34 8ES United Kingdom Name and address of the factory Nom et adresse de l’usine TDK-LAMBDA CORP 2704-1 SETTAYA-MACHI NAGAOKA-SHI, 940-1195 NIIGATA-KEN Japan Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la 2ème page Additional Information on page 2 Ratings and principal characteristics Valeurs nominales et caractéristiques principales 133-318Vdc nom 100-240Vac nom, 45-440Hz 4.7A rms max, 3.8Adc max (See enclosure 7-01 for details of outputs on test report) Trademark (if any) Marque de fabrique (si elle existe) TDK-Lambda Type of Manufacturer's Testing Laboratories used Type de programme du laboratoire d'essais constructeur Model / Type Ref. Ref. De type EFE300 Series See Page 2 Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire,, peuvent être indiqués sur la 2ème page For building-in. Also investigated to EN 60950-1:2006 + A11:2009 A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la IEC 60950-1(ed.2) As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport d’essais numéro de référence qui constitue partie de ce Certificat E135494-A33-CB-2 issued on 2012-02-09 Additional Information on page 2 This CB Test Certificate is issued by the National Certification Body Ce Certificat d’essai OC est établi par l’Organisme National de Certification UL (US), 333 Pfingsten Rd IL 60062, Northbrook, USA UL (Demko), Borupvang 5A DK-2750 Ballerup, DENMARK UL (JP), Marunouchi Trust Tower Main Building 6F, 1-8-3 Marunouchi, Chiyoda-ku, Tokyo 100-0005, JAPAN UL (CA), 7 Underwriters Road, Toronto, M1R 3B4 Ontario, CANADA For full legal entity names see www.ul.com/ncbnames Date: 2012-02-09 Signature: Jan-Erik Storgaard 1/2 Ref. Certif. No. DK-6050 Model Details: EFE300 Series ( EFE300x-a-bcde- f-g-hij) Factories: TDK-LAMBDA UK LTD KINGSLEY AVE ILFRACOMBE, EX34 8ES United Kingdom TRIO ENGINEERING CO LTD SHIJI INDUSTRIAL ESTATE DONGYONG PANYU GUANGZHOU, GUANGDONG China Unit Configuration Code: EFE300x-a-bcde- f-g-hij where: x=Nothing or J for Japanese models (may have non-safety differences) a=Channel 1 Output Voltage: any voltage within the Adjustment Range for the Vout (nom) from the Output Table below, e.g. 12.8 for 12.8V output (12Vout nom), 24.6 for 24.6V output (24Vout nom). b=CN for Open Frame with fan output , CU for U chassis with fan output, CC for U chassis and cover with fan output, EC for U chassis and cover with fan. c=M for Molex input connector or equivalent, J for JST connector or equivalent. d=D for dual fused input. e=S for Standard Leakage, L for Low Leakage, R for Reduced Leakage, T for Tiny Leakage.* f=Nothing for horizontal output connector, V for vertical output connector. g=Nothing for standard channel 1 output voltage, xD or xPD where D is for units with programmed negative load regulation, PD is for units with programmed positive load regulation, x is the voltage of the regulation in 100mVolts and is within the Output Adjustment range (example, 7D = 0.7V of negative load regulation, 24PD = 2.4V of positive load regulation). hij=Three numbers from 0 to 9 which denotes various output voltage/current settings within the specified ranges of each output for a particular unit or blank for standard output settings. (may define non-safety related parameters/feature, e.g. reduced primary current limit, reduced OVP) * At 440Hz, leakage current is > 3.5mA and therefore must be assessed in the end use application. * L < 300uA leakage, R < 150uA leakage and T < 75uA leakage. Additional information (if necessary) Information complémentaire (si nécessaire) UL (US), 333 Pfingsten Rd IL 60062, Northbrook, USA UL (Demko), Borupvang 5A DK-2750 Ballerup, DENMARK UL (JP), Marunouchi Trust Tower Main Building 6F, 1-8-3 Marunouchi, Chiyoda-ku, Tokyo 100-0005, JAPAN UL (CA), 7 Underwriters Road, Toronto, M1R 3B4 Ontario, CANADA For full legal entity names see www.ul.com/ncbnames Date: 2012-02-09 Signature: Jan-Erik Storgaard 2/2