DK-6050 - TDK

Transcription

DK-6050 - TDK
Ref. Certif. No.
DK-6050
IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST
CERTIFICATES FOR ELECTRICAL EQUIPMENT
(IECEE) CB SCHEME
SYSTEME CEI D’ACCEPTATION MUTUELLE DE
CERTIFICATS D’ESSAIS DES EQUIPEMENTS
ELECTRIQUES (IECEE) METHODE OC
CB TEST CERTIFICATE CERTIFICAT D’ESSAI OC
Product
Produit
Power Supply
Name and address of the applicant
Nom et adresse du demandeur
TDK-LAMBDA UK LTD
KINGSLEY AVE
ILFRACOMBE, EX34 8ES United Kingdom
Name and address of the manufacturer
Nom et adresse du fabricant
TDK-LAMBDA UK LTD
KINGSLEY AVE
ILFRACOMBE, EX34 8ES United Kingdom
Name and address of the factory
Nom et adresse de l’usine
TDK-LAMBDA CORP
2704-1 SETTAYA-MACHI
NAGAOKA-SHI, 940-1195 NIIGATA-KEN Japan
Note: When more than one factory, please report on page 2
Note: Lorsque il y plus d'une usine, veuillez utiliser la 2ème page
Additional Information on page 2
Ratings and principal characteristics
Valeurs nominales et caractéristiques principales
133-318Vdc nom
100-240Vac nom, 45-440Hz
4.7A rms max, 3.8Adc max
(See enclosure 7-01 for details of outputs on test report)
Trademark (if any)
Marque de fabrique (si elle existe)
TDK-Lambda
Type of Manufacturer's Testing Laboratories used
Type de programme du laboratoire d'essais
constructeur
Model / Type Ref.
Ref. De type
EFE300 Series
See Page 2
Additional information (if necessary may also be
reported on page 2)
Les informations complémentaires (si nécessaire,,
peuvent être indiqués sur la 2ème page
For building-in. Also investigated to EN 60950-1:2006 + A11:2009
A sample of the product was tested and found
to be in conformity with
Un échantillon de ce produit a été essayé et a été
considéré conforme à la
IEC 60950-1(ed.2)
As shown in the Test Report Ref. No. which forms part
of this Certificate
Comme indiqué dans le Rapport d’essais numéro de
référence qui constitue partie de ce Certificat
E135494-A33-CB-2 issued on 2012-02-09
Additional Information on page 2
This CB Test Certificate is issued by the National Certification Body
Ce Certificat d’essai OC est établi par l’Organisme National de Certification
UL (US), 333 Pfingsten Rd IL 60062, Northbrook, USA
UL (Demko), Borupvang 5A DK-2750 Ballerup, DENMARK
UL (JP), Marunouchi Trust Tower Main Building 6F, 1-8-3 Marunouchi, Chiyoda-ku, Tokyo 100-0005, JAPAN
UL (CA), 7 Underwriters Road, Toronto, M1R 3B4 Ontario, CANADA
For full legal entity names see www.ul.com/ncbnames
Date: 2012-02-09
Signature:
Jan-Erik Storgaard
1/2
Ref. Certif. No.
DK-6050
Model Details:
EFE300 Series ( EFE300x-a-bcde- f-g-hij)
Factories:
TDK-LAMBDA UK LTD
KINGSLEY AVE
ILFRACOMBE, EX34 8ES United Kingdom
TRIO ENGINEERING CO LTD
SHIJI INDUSTRIAL ESTATE
DONGYONG
PANYU
GUANGZHOU, GUANGDONG China
Unit Configuration Code:
EFE300x-a-bcde- f-g-hij
where:
x=Nothing or J for Japanese models (may have non-safety differences)
a=Channel 1 Output Voltage: any voltage within the Adjustment Range for the Vout (nom) from the Output
Table below, e.g. 12.8 for 12.8V output (12Vout nom), 24.6 for 24.6V output (24Vout nom).
b=CN for Open Frame with fan output , CU for U chassis with fan output, CC for U chassis and cover with fan
output, EC for U chassis and cover with fan.
c=M for Molex input connector or equivalent, J for JST connector or equivalent.
d=D for dual fused input.
e=S for Standard Leakage, L for Low Leakage, R for Reduced Leakage, T for Tiny Leakage.*
f=Nothing for horizontal output connector, V for vertical output connector.
g=Nothing for standard channel 1 output voltage, xD or xPD where D is for units with programmed negative
load regulation, PD is for units with programmed positive load regulation, x is the voltage of the regulation in
100mVolts and is within the Output Adjustment range (example, 7D = 0.7V of negative load regulation, 24PD = 2.4V of
positive load regulation).
hij=Three numbers from 0 to 9 which denotes various output voltage/current settings within the specified
ranges of each output for a particular unit or blank for standard output settings. (may define non-safety
related parameters/feature, e.g. reduced primary current limit, reduced OVP)
* At 440Hz, leakage current is > 3.5mA and therefore must be assessed in the end use application.
* L < 300uA leakage, R < 150uA leakage and T < 75uA leakage.
Additional information (if necessary)
Information complémentaire (si nécessaire)
UL (US), 333 Pfingsten Rd IL 60062, Northbrook, USA
UL (Demko), Borupvang 5A DK-2750 Ballerup, DENMARK
UL (JP), Marunouchi Trust Tower Main Building 6F, 1-8-3 Marunouchi, Chiyoda-ku, Tokyo 100-0005, JAPAN
UL (CA), 7 Underwriters Road, Toronto, M1R 3B4 Ontario, CANADA
For full legal entity names see www.ul.com/ncbnames
Date: 2012-02-09
Signature:
Jan-Erik Storgaard