SOLARWATT Glass-Foil Solar Modules
Transcription
SOLARWATT Glass-Foil Solar Modules
SOLARWATT Glass-Foil Solar Modules ��������������������������������� The SOLARWATT M230-96 GET LK Solar Modules developed for power grid connected photovoltaic systems integrate the well-known properties of all SOLARWATT´s modules such as a high quality, large energy yields and very low power tolerance with an efficient installation and an outstanding cost effectiveness. SOLARWATT M230-96 GET LK By using high-efficient polycrystalline solar cells of an efficiency up to 15% a high power density will be obtained on roofs. The modules are equipped with Tyco plug connectors that are touch-safe and protected against polarity reversal. monocristalline solar cell with 15 - 17% efficiency, 125 x 125 mm 1054 1604 SOLARWATT AG Maria-Reiche-Straße 2a 01109 Dresden, Germany Tel. +49 (0) 3 51 / 88 95-0 Fax +49 (0) 3 51 / 88 95-111 www.solarwatt.de [email protected] Certified acc. to: DIN EN ISO 9001 and 14001 SOLARWATT Solar modules M230-96 GET LK are noted for: Efficient, low-loss energy production Certified materials and quality of workmanship 25 years warranty to power output according to SOLARWATT’s Limited Warranty Conditions Subject to change without notice. 2007/08 Specification M230-96 GET LK Nominal Power Pmax @ STC* 215 Wp 220 Wp 225 Wp 230 Wp 235 Wp 240 Wp 245 Wp 250 Wp typ. Nominal Voltage Umpp @ STC* 47,0 V 47,4 V 47,6 V 47,7 V 47,8 V 48,0 V 48,1 V 48,3 V typ. Nominal Current Impp @ STC* 4,58 A 4,65 A 4,74 A 4,83 A 4,92 A 5,01 A 5,10 A 5,18 A typ. Open Circuit Voltage UOC @ STC* 58,3 V 58,5 V 58,7 V 58,9 V 59,1 V 59,2 V 59,3 V 59,4 V typ. Short Circuit Current ISC @ STC* 5,07 A 5,13 A 5,21 A 5,28 A 5,40 A 5,50 A 5,60 A 5,65 A Off-load voltage rating 58,3 V 58,5 V 58,8 V 59,4 V 59,7 V 59,2 V 58,9 V 58,9 V 45 ° C NOCT ** typ. Nominal Power Pmax @ NOCT** 155 Wp 158 Wp 162 Wp 166 Wp 169 Wp 173 Wp 176 Wp 180 Wp typ. Nominal Voltage Umpp @ NOCT** 41,5 V 41,9 V 42,1 V 42,1 V 42,2 V 42,4 V 42,6 V 42,7 V typ. Open Circuit Voltage UOC @ NOCT** 52,8 V 53,0 V 53,3 V 53,8 V 54,1 V 53,6 V 53,4 V 53,8 V typ. Short Circuit Current ISC@ NOCT** 4,08 A 4,13 A 4,19 A 4,25 A 4,35 A 4,43 A 4,51 A 4,55 A Module efficiency reduction at 200 W/m *** -0,2 % -0,2 % -0,2 % -0,3 % -0,3 % -0,3 % -0,3 % -0,3 % 2 typ. Temperature Coefficient of PN -0,50 %/K typ. Temperature Coefficient of Uoc -0,37 %/K typ. Temperature Coefficient of ISC +0,03 %/K Max. System Voltage 1000 V IP protection level IP 65 Reverse current power rating IR*** 15 A Module Technology Module Design No. and Type of Solar Cells Cables Bypass-Diodes Dimensions (LxWxH) Weight Glass-Foil-Laminate Cover material: high transparent solar glass (tempered), 4 mm Encapsulation: EVA-Solar Cells -EVA Back material: Tedlar-Polyester-Tedlar, white 96 monocrystalline solar cells, 125 x 125 mm Junction box with Tyco Plug connector cables, 2 x 4 mm2, length: each 1.2 m 4 pcs. 1604 x1054 x 5 mm 24 kg Operating Temperature Range -40 ... +80 °C Ambiente Temperature Range -40 ... +45 °C Mechanical ratings Qualifications 2.400 Pa approved (Wind speed 130 km/h with safety factor 3) IEC 61215 (Ed. 2 in preparation), Safety Class II, IEC 61730 in preparation Measuring tolerances Pmax @ STC ± 5%, all other electric parameters ± 10% This data sheet conforms to DIN EN 50380:2003 * STC : Standard Test Conditions, conditions de mesure : Intensité d’irradiation 1000 W/m2, répartition spectrale AM 1,5, température 25±2 °C, selon norme EN 60904-3 ** NOCT : Normal Operation Cell Temperature, conditions de mesure : Intensité d’irradiation 800 W/m2, AM 1,5, température 20 °C, vitesse du vent 1m/s, marche à vide électrique *** Baisse du rendement des modules avec la diminution de l’intensité d’irradiation de 1000 W/m2,à 200 W/m2, température 25 °C, selon norme EN 60904-1 **** Courant de retour admissible L’utilisation d’une alimentation externe n‘est autorisée sur les modules qu‘à condition d‘utiliser un fusible calibré à < 3 x ISC @ NOCT**