Montage- und Bedienungsanleitung Mounting and operating instructions Instructions de montage et mode d'emploi CALEC® MB Wärmerechner Heat meter calculator Calculateur d'énergie thermique VD 3-168 DEF 06.2005 79,5 Elektronikbaugruppe mit Klemmenbezeichnungen 150 (116,5) (203) (193,5) 77 4,5 140 OPT 1 OPT 2 100 OPT 3 (48) OPT 4 Steckbrücke für Eingang 1 Steckbrücke für Eingang 2 1 1 110 DIN-Schienenmontage: 2 Befestigungsschrauben Ø5 mm Dreilochmontage: 3 Befestigungsschrauben Ø5 mm DIN-Rail mounting: 2 screws Ø5 mm 3-holes mounting: 3 screws Ø5 mm Montage rail DIN: 2 vis Ø5 mm Fixation à 3 vis: 3 x Ø5 mm 159 +0,3 167 +0,50 1 5 6 2 + + - Source Sense Warm Sense Seite Source 3 7 8 4 + + - Source Sense Kalt Sense Seite Source 10 + Input 1 11 - Input 1 +0,3 (79,5) (4) 1 56 + 57 24 25 60 61 64 + 65 50 + 51 52 + 53 - Input 2 Input 2 M-Bus M-Bus ~15VAC ~15VAC 18V/100mA Out 18V/100mA Out Option 1 OUT 1 Option 1 OUT 2 70 + 71 72 + 73 74 + 75 76 + 77 78 + 79 80 + 81 - Option 2 OUT 1 Option 2 OUT 2 Option 3 OUT 1 Option 3 OUT 2 Option 4 OUT 1 Option 4 OUT 2 Aktiv 1 Analog 1 Aktiv MAGxx/ SONOxx LEFT 1 Achtung: Steckkarten mit der Bestückungsseite gegen die Klemmen einbauen! 66117fd.eps L = Phase, N = Nullleiter AM066117a 16 Passiv 209 (7) 68 Steckbrücken für Eingangsvarianten: 25 61 65 51 53 71 73 75 77 79 81 57 11 4 8 2 6 24 60 64 50 52 70 72 74 76 78 80 56 10 3 7 1 5 10 +0,50 5,8 195 229,5 174 L N Ausschnitt in Schalttafel Panel cut out Découpe du tableau Netzanschluss 230V/50Hz L Phase N Nulleiter Fronteinbau mit MPM-Montagesatz Panel mounting with MPM-Kit Montage en tableau avec kit MPM VD 3-168 DEF 2 Aquametro AG Module électronique avec désignation des bornes Electronic sub-assembly with terminal designations OPT 1 OPT 1 OPT 2 OPT 2 OPT 3 OPT 3 OPT 4 OPT 4 Jumper connections for input 1 Jumper connections for input 2 L N 1 1 25 61 65 51 53 71 73 75 77 79 81 57 11 4 8 2 6 24 60 64 50 52 70 72 74 76 78 80 56 10 3 7 1 5 1 5 6 2 + + - Source Sense Hot Sense Side Source 3 7 8 4 + + - Source Sense Cold Sense Side Source 10 + Input 1 11 - Input 1 56 + 57 24 25 60 61 64 + 65 50 + 51 52 + 53 - Input 2 Input 2 M-Bus M-Bus ~15VAC ~15VAC 18V/100mA Out 18V/100mA Out Option 1 OUT 1 Option 1 OUT 2 70 + 71 72 + 73 74 + 75 76 + 77 78 + 79 80 + 81 - Option 2 OUT 1 Option 2 OUT 2 Option 3 OUT 1 Option 3 OUT 2 Option 4 OUT 1 Option 4 OUT 2 Mains connection 230V/50Hz L Live N Neutral Cavaliers pour entrée 1 Cavaliers pour entrée 2 Jumper arrangements for input variants: Passive 1 Active 1 Analogue 1 Active MAGxx/ SONOxx L N 1 25 61 65 51 53 71 73 75 77 79 81 57 11 4 8 2 6 24 60 64 50 52 70 72 74 76 78 80 56 10 3 7 1 5 LEFT 1 Important: Install the plug-in cards with the components side towards the terminals! 1 5 6 2 + + - Source Sense Côté Sense Chaud Source 3 7 8 4 + + - Source Sense Côté Sense Froid Source 10 + Input 1 11 - Input 1 56 + 57 24 25 60 61 64 + 65 50 + 51 52 + 53 - Input 2 Input 2 M-Bus M-Bus ~15VAC ~15VAC 18V/100mA Out 18V/100mA Out Option 1 OUT 1 Option 1 OUT 2 70 + 71 72 + 73 74 + 75 76 + 77 78 + 79 80 + 81 - Option 2 OUT 1 Option 2 OUT 2 Option 3 OUT 1 Option 3 OUT 2 Option 4 OUT 1 Option 4 OUT 2 Raccordement au réseau 230V/50Hz L Phase N Neutre Cavaliers pour variantes d'entrée: Passive 1 Active 1 Analogique 1 Active MAGxx/ SONOxx LEFT 1 Attention: Monter les cartes enfichables avec le côté composants du côté des serre-fils! 66117ff.eps 66117fe.eps L = phase, N = neutre L = Live, N = Neutral Aquametro AG 1 3 VD 3-168 DEF Inhaltsverzeichnis/Contents/Table des matières Massbilder Elektronikbaugruppe mit Klemmenbezeichnungen 1. Produktvorstellung und Verpackung 2. Anschlussvorschrift 3. Anschlussschemas 4. Anschluss des Temperaturfühlerpaares 5. Anschluss des Durchflussgebers 6. Ausgangssignale 7. Deckel aufsetzen und verschliessen 2 2 5-6 7 8-9 10 11 12-13 14 8. Inbetriebnahme, Funktionskontrolle 9. Fehlermeldungen 10. Technische Daten 11. Hinweis auf Eichpflicht 12. Einsatzdauer und Wartung 13. Garantie und Haftung 14. Bedienungsanleitung 15. Konformitätserklärung 16. Anhang: Menu-Übersicht Softwareoptionen 14-15 15-16 17-18 19 19 19 21-23 23 24-26 Diagrammes with dimensions Electronic sub-assembly with terminal designations 1. Product description and packaging 2. Connecting the power supply 3. Wiring diagrams 4. Connecting the temperature sensor pair 5. Connecting the flow transmitter 6. Output signals 7. Replacing and fixing cover 2 3 28-29 30 31-32 33 34 35-36 37 8. Commissioning and operational checks 9. Error messages 10. Technical data 11. Validity of calibration 12. Service life and maintenance 13. Guarantee and liability 14. Operating instructions 15. Declaration of conformity 16. Annexe: Menu-overview software options 37-38 38-39 40-41 42 42 42 44-46 46 47-50 Schémas d’encombrement Module électronique avec désignation des bornes 1. Présentation du produit et emballage 2. Prescriptions de branchement 3. Schémas de connexion 4. Raccordement des thermosondes 5. Raccordement du débitmètre 6. Signaux de sortie 7. Remise en place du couvercle et fermeture 2 3 51-52 53 54-55 56 57 58-59 60 8. Mise en service, contrôle du bon fonctionnement 9. Messages d’erreur 10. Caractéristiques techniques 11. Étalonnage officiel 12. Durée de service et entretien 13. Garantie et responsabilité 14. Mode d’emploi 15. Déclaration de conformité 16. Annexe: aperçu des menus, options "software" 60 61-62 63-64 65 65 65 67-69 69 70-73 VD 3-168 DEF 4 Aquametro AG 1. Produktvorstellung und Verpackung 1.1 Montageort Das CALEC® MB Wärmerechenwerk dient als Teilgerät einer Wärmezählermesseinrichtung zur exakten Energieverbrauchserfassung. Wir, die Mitarbeiter von Aquametro, haben dieses Produkt mit grösster Sorgfalt hergestellt und geprüft. Die Eichbehörden haben uns, nach strengen Typenprüfungen die Messtauglichkeit gemäss den geltenden Anforderungen bestätigt. • • • • • Bitte helfen Sie, durch eine sorgfältige Installation und dem Befolgen der Einbauvorschriften, dass der Wärmezähler seine Aufgabe dauerhaft und zur Zufriedenheit unserer Kunden erfüllen kann. Gut zugänglich für Montage, Ablesung und Service Geschützten, möglichst trockenen Platz wählen Vor Hitze- und Sonnenbestrahlung schützen Verfügbare bzw. erlaubte Fühlerleitungslängen beachten Abstand von starken elektrischen Störquellen einhalten Zur Installation von Rechenwerk, Durchflussmesser und Temperaturfühlern gelten die Vorschriften und Empfehlungen der Wärmezählernorm EN 1434, Teil 6. Der separate Durchfluss-Impulsgeber ist mit dem Durchflusseingang des Rechenwerks zu verbinden. Der am Rechenwerk aufgeführte Impulswert muss unbedingt mit demjenigen des Durchflussgebers übereinstimmen. Das Temperaturfühlerpaar muss gemäss den Herstellerangaben und den Zulassungsauflagen installiert und eingebaut werden. In der Schachtel befindet sich: 1 Stk. CALEC ® MB Wärmerechner 1 Stk. DIN-Montageschiene 35mm 1 Stk. Zubehörbeutel enthaltend: 4 Metallbrücken für 2-Leiter-Fühleranschluss div. Blindverschlusstopfen klein und gross 4 Plombierzapfen rot 2 Plombierkleber 1 Montagevorschrift, Hinweise 1 Stk. Montage- und Bedienungsanleitung + evtl. Montagebügel nach Bestellung Vorsicht Vorhandene Eich- und Werkplombenkleber nicht entfernen oder beschädigen! Verfall von Eichgültigkeit und Fabrikgarantie! 1.2 Montageanleitung Deckel (Rechneroberteil) durch Lösen der 4 Kreuzschlitzschrauben abnehmen. Der Deckel kann durch Ausziehen des Bandkabelsteckers Aquametro AG 5 VD 3-168 DEF vom Geräteboden (Grundprint) getrennt und bis zur Beendigung der Anschlussarbeiten weggelegt werden. Dazu Bandkabelstecker möglichst parallel durch beidseitiges Fassen am Kabel herausziehen! Vor dem Einschalten der Netzspannung ist die Verbindung wieder herzustellen! 1.3 Sicherstellung der Schutzklasse Die Umgebungsschutzklasse IP54 ist nur bei unausgebrochenen Befestigungslöchern gewährleistet. Die Einhaltung des verlangten Schutzgrades ist durch den Betreiber mit einer einwandfreien Montage sicherzustellen. Dies trifft besonders für die Kabeleinführung zu. Nur gut passende Kabel und fest angezogene Gummidichtungen führen zum Erfolg! Gehäuseboden durch Aufschnappen auf mitgelieferte 35 mm DIN-Schiene (EN 50022) befestigen, oder gemäss Massbild auf Seite 2 mit Holzschrauben (5 x 30, kein Senkkopf) an die Wand schrauben. Die obere Schraube dient dabei als Aufhängepunkt. 1.4 Kabeleinführungen Zur fachgerechten Installation sind insgesamt 9 Kabelverschraubungen vorhanden, nämlich: 1 3 5 7 1 x PG 11 zur Einführung des Netzanschlusses (Kabel Ø 5...10 mm) A 6 2 B Pos.A 1 x PG 13 zur Einführung eines Steuerkabels (Kabel Ø 6...12 mm); zur eventuell gemeinsamen Fühler- und Impulsgeberverlängerung Pos.B 7 x PG 7 zur Einzeleinführung (KaBild-5.eps bel Ø 2...5 mm) von Temperaturfühler, Impulsgeber und anderen Signal-Ein- und Ausgängen. Pos. 1-7. Zum ordnungsgemässen Festziehen der eng beieinanderliegenden Ver- Bild-2.eps Für den Frontplatteneinbau wird ein Montagechassis und ein Frontrahmen (gemäss Massbild Seite 2, unten) benötigt. Der Einbausatz (MPM) umfasst eine Gummidichtung, welche das Gerät umschliesst. Für den Ersatz von bestehenden in Frontplatten eingebauten MCL- und MCP-Modellen steht ein vorbereiteter Montage- und Umbausatz (CPM) zur Verfügung. VD 3-168 DEF 6 Aquametro AG Phase Das Gerät kann entweder mit einem 230 V-Netzanschluss oder am AMBUS®-Kleinspannungsnetz betrieben werden. Die Versorgungsart richtet sich nach dem vorgeplanten Messkonzept. Sämtliche Anschlüsse sind nach dem beiliegenden Anschlussschema auszuführen. Klemmen bis Nr. 50 entsprechen der Wärmezählernorm EN 1434-2. Arbeiten am 230 V-Netz dürfen nur von berechtigten Fachleuten unter Beachtung der geltenden Vorschriften ausgeführt werden! Wird Netzspannung an anderen als den Klemmen L + N angelegt, besteht Lebensgefahr und das Gerät wird zerstört! 66117gd.eps 2. Anschlussvorschrift Null Netzspannung möglichst an einer separaten Sicherung oder am Heizungsstromkreis anschliessen. Das Gerät ist schutzisoliert und benötigt keinen Schutzleiteranschluss. Der Netzanschluss erfolgt an den mit L + N bezeichneten Klemmen. Alle übrigen Klemmen sind ausschliesslich für Kleinspannung (<50 V) und Messsignale reserviert. Anschluss: Das Netzanschlusskabel (5-10 mm Ø) durch die linke (Pos. A) PG11-Stopfbuchse (SW 22) einführen und gut festziehen. Netzleiter an Klemme N und L anschliessen. Das Schlaufen der NetzKleinspannungsversorgung anschlussleitungen ist aus praktischen Gründen nicht L N oder 25 61 möglich. Wird kein Netzkabel benötigt, so ist die leere 24 60 Kabelverschraubung mit eie.x..4x0.8 230 V / 50 Hz 15VAC Meternem (im Zubehörbeutel mitNetzanschluss AMBUS .Bus gelieferten) Deckel abzudichten. 2.2 schraubungen ist der Einsatz eines geschlitzten Steckschlüssels von 15 mm Schlüsselweite erforderlich (Foto). Nichtbenützte Kabeleinführungen sind mit den beigelegten Verschlusskappen abzudichten! Kleinspannungsanschluss (15V) an die zentrale Busstromversorgung 2.1 Dieser Anschluss dient der eingeschränkten Kleinspannungsversorgung bei fehlender Netzspannung. In Verbindung mit einem AMBUS®- Zentralgerät wird diese Versorgung zusammen mit dem 2 poligen M-Bus zum CALEC®-MB geführt und ermöglicht so eine sichere Kommunikation. Das Gerät wird mit einem 4-poligen runden Anschlusskabel (3-5mm Ø) mit einer beliebigen Busabzweigdose verbunden. Der Anschluss erfolgt an den beiden Klemmen 60 und 61. Wird kein Buskabel eingeführt, so ist die Kabelverschraubung zu verschliessen. In Deutschland ist nur die 230 V-Versorgung für den eichpflichtigen Betrieb zugelassen. 230 V- Netzanschluss Die Stromversorgung ist gegen mutwillige Unterbrechung ausreichend zu sichern. Der Wärmezähler ist nach dem Stand der Technik so zu schützen, dass bei einem elektrischen Fehler eine sichere Abschaltung erfolgt. Die Vorsicherung ist auf max. 10 A zu begrenzen. Aquametro AG 7 VD 3-168 DEF 3. Anschlussschemas Anschluss mit 2 Relaisausgängen und Impulssammlereingang (ISPC) Anschlussschema CALEC® MB Null Phase Steckkarte 1 Hilfsspannung 18 V DC / 100mA OUT 1 OUT 2 AM066103.4 50 51 52 53 OUT 3 OUT 4 7370 71- 72 + + Warmseite Hot side Côté chaud 1 5 6 2 Kaltseite Cold side Côté froid Netzanschluss 230 V / 50 HZ AM066117ed1 Null Phase Emetteur d'imp. ou entrée tarif + Durchflussgeber oder Tarifeingang Flow sensor or tariff input + - Anschluss Steuer- und Tarifeingang (DTF), gesteuert durch internes Relais L N Hilfsspannung 18 V DC / 100mA Steckkarte 2 z.B. DTF Eingang 2 2RWC od. 2RNC od. 2AOU OUT 3 OUT 4 5756 + 7370 71- 72 + + 50 51 52 53 Impulsgeber Flow sensor Débitmètre 64 65+ Steckkarte 1 2RWC od. 2RNC OUT 1 OUT 2 - Netzanschluss 230 V / 50 HZ AM066117ed2 + Nulleiter / Neutral / Neutre Phase / Line / Phase VD 3-168 DEF 3 7 8 4 Hilfsspannungsausgang Auxiliary voltage output Sortie de tension auxiliaire 18VDC 64 65 M-Bus M-Bus Kleinspannungsversorung Low voltage connection Alimentation basse tension L N OUT5 OUT6 Optionskarte 3 Option card 3 Carteoption 3 Optionskarte 2 Option card 2 Carteoption 2 OUT3 OUT4 OUT1 OUT2 Option IN2 Optionskarte 1 Option card 1 Carteoption 1 50 51 52 53 + - + 70 71 72 73 + - + 74 75 76 77 Durchfluss / Flow / Débit 64 65 z.B. ISPC Eingang 2 (IN 2) 56 57 Netzanschluss Mains supply Alimentation réseau 230V/50Hz Eingang 1 / Input 1/ Entrée 1 IN1 10 11 Source Sense Sense + Source + 56 57 OUT7 OUT8 Optionskarte 4 Option card 4 Carteoption 4 + - + 78 79 80 81 Anschlüsse Connections Connexions L N Source Sense Sense + Source + 60 61 24 25 Wärmerechner Heat calculator CALEC MB Calculateur de chaleur Steckkarte 2 8 Aquametro AG Anschlussvarianten der Analogausgänge Passive Analogausgänge (Steckbrücke auf passiv) 64 65 L N OUT 1 OUT 2 50 51 52 53 OUT 3 Steckkarte 1 (2AOU) OUT 4 73 70 71 72 + + - Hilfsspannung 18 V DC / 100mA Null Hilfsspannung 18 V DC / 100mA Achtung: Polarität vertauscht! Steckkarte 2 (2AOU) Phase Null Phase Steckkarte 1 (2AOU) Aktive Analogausgänge (Steckbrücke auf aktiv) 64 65 L N - - DC Quelle 5...24 V AM066117ed3 OUT 2 OUT 3 - + + - + Null Phase L N Hilfsspannung 18 V DC / 100mA max. 64 65 OUT 1 OUT 2 50 51 52 53 + AM066117ed5 Steckbrücke auf Optionsbaugruppe 2AOU: Steckkarte 2 (2AOU) OUT 3 - Netzanschluss 230 V / 50 HZ Aktive Analogausgänge (Steckbrücke auf passiv) Steckkarte 1 (2AOU) OUT 4 7370 71- 72 + + 50 51 52 53 + Netzanschluss 230 V / 50 HZ OUT 1 Steckkarte 2 (2AOU) OUT 4 7370 71- 72 + + 1 6 Netzanschluss 230 V / 50 HZ Rv AM066117ed4 aktiv Bürde: R V max = (Us-5)/0.02A Us = 24V Aquametro AG passiv Beispiel: (24V-5V) / 0.02A = 950Ω 9 VD 3-168 DEF 4. Anschluss des Temperaturfühlerpaares Direktanschluss (Anschlussbild a): Geeignet für Kabelfühler mit ungekürztem Originalkabel! Empfohlene Anschlussarten Kabelfühler direkt angeschlossen 57 11 56 4 10 8 3 Kabelfühler mit 4-Drahtverbindung 2 7 57 6 1 11 56 5 Wichtig: Die Originalanschlusskabel von Kabelfühlern dürfen nicht gekürzt werden, da der vorhandene Leitungswiderstand immer zum Temperatur-Messwiderstand addiert wird! Vorsicht! 4 10 8 3 2 7 Kabelfühler mit 2-Drahtverbindung Kopffühler mit 4-Drahtverbindung 6 1 57 11 56 5 4 8 10 3 7 2 6 57 5 1 11 56 4 10 8 3 2 7 6 1 4-Drahtverlängerung: (Anschlussbild b + c) Kabelverlängerungen sind mit einer gesicherten Verbindung und einem 4-adrigen Verbindungskabel (4 x 0,8 Ø) pro Fühler, gemäss dem Fühleranschlussbild b oder c auszuführen. Diese Anschlussart ist vorzuziehen, besonders wenn die Originalfühlerkabel zu kurz sind, um gemäss Bild a direkt angeschlossen werden zu können. 5 d) c) b) a) VD-30 Kaltseite Fühlertypen: PLH85/100 PLH120/100 TPK1121..21..31 Warmseite Warmseite Kaltseite Kaltseite Fühlertypen: PLC85/100/2 PLC120/100/2 PLC210/100/2 DS100 Warmseite Kaltseite Warmseite VD-30 66117B VD 3-168 DEF 10 2-Drahtverlängerungen gemäss Anschlussbild d sind möglichst zu vermeiden. Aquametro AG 11 - 4 10 2 8 3 7 57 6 1 + Durchflussgeber 5. Anschluss des Durchflussgebers OPTION 11 - 4 10 56 5 IN 2 2 8 3 7 + 2. Durchflussgeber oder Tarif-Eingang 6 1 5 66117cd.eps 57 56 Im Gegensatz zu den Temperaturfühlern ist die Leitungsführung des Durchflusssignals unkritisch. Als Leitungstyp eignet sich 2 x 0,8 ØKabel. Bei der Verwendung von Passiv-Impulsgebern ist das Zusammenführen in einem gemeinsamen Verlängerungskabel mit den Temperaturfühlern möglich. Ein allfällig zweiter Eingang wird an den Klemmen 56 / 57 angeschlossen. Die Funktion hängt von der spezifizierten Ausführung ab (DTF, ISPC, etc). Am Durchflusseingang (Klemmen 10 + 11) können vier verschiedene Arten von Volumengebern angeschlossen werden. • Mechanische Reed- oder Relaiskontakte • Elektronische Namur-Impulsgeber nach DIN 19 234 und „open collector“-Schalter. Bei diesen Gebern ist auf die Anschlusspolarität gemäss Anschlussschema zu achten! • Aktiv-Ausgänge: Ein externer Stromimpuls versorgt den galvanisch getrennten Eingangsstromkreis des Rechenwerkes. • Analoge Durchflussgeber: der Durchfluss wird in ein 0/4...20 mAStromsignal umgewandelt. Wichtig: Durchflussgeber können höchst unterschiedliche Impulswerte aufweisen! Bitte immer nur Teilgeräte mit gleichen Impulswertigkeiten (Liter pro Impuls) miteinander verbinden! Die Umschaltung von elektronischen Passiv-Impulsgeber auf AktivImpulsgeber kann (auch nachträglich) durch Umstecken der Steckbrücken unmittelbar über den Anschlussklemmen erfolgen. Die notwendigen Einstellungen sind auf dem aufgeklebten Anschlussschema ersichtlich. (Diese Massnahme ist nur bei einem Wechsel des Impulsgebertyps gegenüber der Bestellspezifikation erforderlich). Ein nachträgliches Umprogrammieren des Impulswertes verbietet die Eichgesetzgebung in allen Fällen wo der Zähler zur Verrechnung verwendet wird. Gleiches gilt für die Abschaltung des Entprellschutzes und den Wechsel des Kaltseite- oder Warmseite-Einbauortes des Durchflussgebers. Aquametro AG IN 1 Durchfluss Fühlereinbau Die Temperaturfühler werden nach der geltenden EN 1434-Norm entweder direkt via Kugelhahn oder mit Tauchhülsen in die Rohrleitung eingebaut. Der Einbau ist mit grösster Sorgfalt vorzunehmen, da dieser die Messgenauigkeit entscheidend beeinflussen kann! Prellschutz Wird das Gerät für mechanische Impulsgeber (I.) geliefert, so ist der Eingang bereits mit einer Kontaktentprellung versehen. Diese ist fest programmiert und kann nicht ausgeschaltet werden. 11 VD 3-168 DEF Relaisausgang 50+52 70+72 74+76 78+80 Analogausgang max.100mA/50V CALEC® MB sind serienmässig mit der genormten M-Bus-Schnittstelle nach EN 1434-3 versehen, mit welcher sich alle relevanten Parameter auslesen, sowie alle Ausgangsfunktionen programmieren lassen. Der polaritätsunabhängige Busanschluss erfolgt an den Klemmen 24 / 25. RL OUT 1...8 Die vorhandenen Optionen werden gemäss dem Anschlussschema an den Klemmen 50...53 (Steckplatz 1), 70...73 (Steckplatz 2), 74...77 (Steckplatz 3) und 78...81 (Steckplatz 4) angeschlossen. Je nach eingesteckter Kartenart, sind pro Karte zwei Kontakt-, zwei Analog-Stromkreise, eine RS232- oder eine RS485-Schnittstelle verfügbar. Die Kennzeichnung der vorhandenen Karten, deren Funktion, Einstellungen und Anschlüsse kann in der Anzeige unter ”Feld-Konfiguration” eingesehen werden (z.B. OUT 1-Relais-Klemme 50/51-Impuls Energie1-Impulswert 1 kWh). 0/4 .. 20 mA + AC or DC 51+53 71+73 75+77 79+81 RV OUT 1...8 51+53 71+73 75+77 79+81 DCQuelle - Analogausgang Jeder Stromkreis lässt sich einzeln als aktiver oder passiver Analogausgang konfigurieren. Die aktiven Ausgänge werden von der internen Hilfsspannung mit maximal 100 mA versorgt. Potenzialtrennung Die passiven Analogausgänge sind untereinander galvanisch getrennt. Die aktiven Analogausgänge sind über die gemeinsame Masse verbunden. Sie sind mit der Hilfsspannung und den Optionskarten galvanisch verbunden, aber vom Rest der Elektronik galvanisch getrennt. Ist die Klemmennummer eines Ausganges nicht bekannt, bzw. ist kein Anlageschema erstellt worden, so kann dies auch nachträglich an der Anzeige abgelesen werden. Belastung Bei Verwendung der internen Hilfsspannung darf die Bürde aller Analogkreise folgender Wert nicht überschreiten: Wichtig: Optionenkarten nie unter Spannung einbauen oder austauschen! Risiko von Datenverlust! R V max = (Us-5)/0.02 A Relaisausgang Pro Optionskarte 2RNC bzw. 2RWC sind 2 Halbleiter-Relais verfügbar, die mit max. 100 mA AC oder DC bei max. 50 V belastet werden dürfen. VD 3-168 DEF 50+52 70+72 74+76 78+80 66117dd.eps 6. Ausgangssignale Andernfalls sollten alle Analogausgänge mit einer leistungsstärkeren externen Quelle versorgt werden. 12 Aquametro AG RS232-Kommunikationsschnittstelle Die Schnittstelle wird von der Hilfsspeisung gespeist und ist somit vom Grundgerät galvanisch getrennt. Die Signale für GND, TXD und RXD sind an den Anschlussklemmen verfügbar. An einer vierten Anschlussklemme wird ein Signal von +10V angelegt, welches als DTR bzw. RTS verwendet werden kann. Die Kommunikationsschnittstelle verwendet das M-Bus-Protokoll nach EN 1434-3;1997 und IEC 870-5. Sie unterstützt Übertragungsraten von 300 bis 9600 Baud. Die Kommunikation erfolgt in Halbduplex. Die RS232Schnittstelle verwendet gretrennte Kanäle für Senden und Empfangen. RS485-Kommunikationsschnittstelle Die Schnittstelle wird von der Hilfsspeisung gespeist und ist somit vom Grundgerät galvanisch getrennt. Die Kommunikationsschnittstelle verwendet das M-Bus-Protokoll nach EN 1434-3;1997 und IEC 870-5. Sie unterstützt Übertragungsraten von 300 bis 9600 Baud. Die Kommunikation erfolgt in Halbduplex. Die RS485Schnittstelle sendet und empfängt über den gleichen Kanal. RS232 RS485 B+ B- Steckplatz 1 Kl. 50 Kl. 51 Kl. 52 Kl. 53 TXD RXD GND +10V Steckplatz 2 Kl. 70 Kl. 71 Kl. 72 Kl. 73 Steckplatz 1 Kl. 50 Kl. 51 Kl. 52 Kl. 53 Steckplatz 3 Kl. 74 Kl. 75 Kl. 76 Kl. 77 Steckplatz 2 Kl. 70 Kl. 71 Kl. 72 Kl. 73 Steckplatz 4 Kl. 78 Kl. 79 Kl. 80 Kl. 81 Steckplatz 3 Kl. 74 Kl. 75 Kl. 76 Kl. 77 Steckplatz 4 Kl. 78 Kl. 79 Kl. 80 Kl. 81 Aquametro AG 13 VD 3-168 DEF 7. Deckel aufsetzen und verschliessen ausgeführt werden. Bei vorhandener AMBUS® FA/ZS-Vernetzung, können alle angeschlossenen Zähler gleichzeitig eingestellt werden. Nach dem Anschluss aller Verbindungen, im spannungslosen Zustand den Bandkabelstecker wieder vorsichtig einstecken und dessen sicheren Halt kontrollieren. Beim Schliessen des Deckels ist auf die korrekte Lage der Dichtung zu achten. Deckelschrauben gleichmässig und mit Vernunft anziehen (Kunststoffgewinde). Plomben und Sicherheitskleber erst nach erfolgreicher Inbetriebnahme der Messung anbringen! Durchflusskontrolle ★-Anzeige im Totalisatorfeld, blinkt bei Durchfluss. Die Blinkfrequenz steht in keinem Zusammenhang mit der Durchflussmenge. Durchflusswerte sind unter “Momentanwerte” sichtbar (Q xxxxx m3/h). 8. Inbetriebnahme, Funktionskontrolle Analogausgänge zeigen den aktuellen Ausgangsstrom-Sollwert in mA an. Nachprüfen unter ”Feldkonfiguration”-”Ausgang Nr...”- ”Funktion”. Der angegebene Strom ist ein Sollwert und sollte mit dem Sekundärstrom übereinstimmen, sofern die Hilfsspannung und die Bürde des Analogstromkreises korrekt angeschlossen sind. Kontrolle der Optionsausgänge Relaisausgänge bewirken bei jedem Schalten einen Zählschritt des Ereigniszählers. Anhand des entsprechenden Zählerstandes kann die Ausgangsfunktion überprüft werden. Nachprüfen unter ”Feldkonfiguration” - ”Ausgang Nr...” - ”Funktion”. Die Inbetriebnahme einer Wärmemessung bezweckt, die messtechnische Funktionstüchtigkeit zu überprüfen, um die Richtigkeit der Messung garantieren zu können. Aquametro empfiehlt dringend, die Inbetriebnahme durch einen ihrer Spezialisten ausführen zu lassen. Abschluss und Plombierung Nach der endgültigen Inbetriebnahme werden die zwei oberen Schrauben des Gerätedeckels mit den mitgelieferten Verschlusszapfen gesichert. Die unteren beiden Schrauben werden mit den ebenfalls mitgelieferten Benutzersicherungskleber versiegelt. Setzen von Datum und Uhrzeit Ohne Echtzeituhrkarte (2RWC) bleibt die interne Uhr im spannungslosen Zustand stehen. Sollen die Stichtagsablesung und die Loggerfunktionen sinnvoll benützt werden, so ist bei der definitiven Inbetriebnahme das Datum und die Uhrzeit über die Schnittstelle einzustellen. Die Präsenz der Echtzeituhrkarte ist an der Datumanzeige ersichtlich, wenn diese mit dem aktuellen Datum übereinstimmt. Der interne Betriebstundenzähler registriert die Gesamtfunktionsdauer. Zeitkorrekturen können sowohl mit den Tasten (siehe Bedienung) als auch über die Kommunikationsschnittstelle VD 3-168 DEF 14 Aquametro AG 9. Fehlermeldungen Auftretende Fehler werden in der Hauptanzeige durch abwechselndes Blinken von ****Fehler**** an den zwei Zeilen angezeigt. Im Untermenue "Fehlermeldung" wird die Fehlerursache im Klartext angezeigt. Behebbare Fehler, wie vertauschte Temperaturfühler oder Verbindungsfehler, können vor Ort beseitigt werden. Gerätefehler müssen in der Regel durch den Austausch des fehlerhaften Gerätes beseitigt werden. Aquametro AG 15 VD 3-168 DEF 3-168-d.eps Inbetriebnahme-Checkliste 1. Zugehörigkeit von Durchflussmesser und Rechenwerk: Stimmt der Impulswert (bzw. Messbereich bei analogen Gebern) vom Durchflussmesser mit dem des Rechenwerks überein ? 2. Liegt der erwartete Durchfluss innerhalb des Messbereichs des Gebers ? 3. Ist die Einbaulage des Zählers richtig ? 4. Stimmt die Durchflussrichtung mit der Pfeilrichtung überein ? 5. Wurden die Leitungen gespült ? 6. Sind alle Verbindungen dicht ? 7. Ist der Durchflussgeber komplett eingebaut und mit Wasser gefüllt ? 8. Gehören die Temperaturfühler zum gleichen Paar ? 9. Sind die Temperaturfühler korrekt verkabelt ? Sind eventuelle Leitungsverlängerungen gemäss Anleitung verdrahtet ? 10. Anzeige vorhanden ? 11. Sind die Temperaturen plausibel (Th höher als Tc) ? 12. Ist der Durchfluss plausibel ? 13. Zählerstände Energie ______________ kWh MWh MJ GJ MI Volumen ______________ m3 Betriebsstunden ______________ 14. I n b e t r i e b n a h m e Datum ______________ Uhrzeit ______________ 15. Deckel und ggf. Temperaturfühler schliessen und plombieren F e h l e r me l d u n g HW Temp Alarm (Cold) A rt de s F e hl e rs Hardware Temperatur-Alarm Kaltseite Temperaturmessung nicht möglich HW Temp Alarm (Hot) Hardware Temperatur-Alarm Warmseite Temperaturmessung nicht möglich Delta-T Alarm Differenztemperatur SW Temp Alarm (Cold) Software Temperatur-Alarm Kaltseite SW Temp Alarm (Hot) Software Temperatur-Alarm Warmseite Namur Unterbruch NAMUR-Überwachung Alarm 6 Reserve Alarm 6 Registerüberlauf bei Relais-Impulsfunktion oder RTC Daten unplausibel Problem mit Ausgangsoptions-Karte(n) M ö gl i c he U rs a c he Fehlende Brücken bei Zweileiter-Anschluss Unterbruch bzw. Kurzschluss bei den Fühlerleitungen M a s s n a h me n 4 Brücken nach Anschlussschema verwenden Fühlerleitungen abklemmen und mit Ohmmeter Fühlerleitungen bzw. Fühler überprüfen. Wenn OK, mit Widerstand z.B. 100 Ohm Temperatureingang überprüfen siehe oben siehe oben Bereichüberschreitung Differenztemperatur Zulässiger Bereich dT -10...200°C Bereichüberschreitung Temperatur Kaltseite. Zulässiger Bereich bei Wasser Tc 0...200°C. Bei anderen Wärmeträgern gemäss Angaben. Bereichüberschreitung Temperatur Warmseite. Zulässiger Bereich bei Wasser 0...200°C. Bei anderen Wärmeträgern gemäss Angaben. NAMUR-Geber defekt oder unterbrochen I<0.2 mA Temperaturfühler vertauscht oder siehe oben Aktuelle Temperatur überprüfen Untermenue "Momentanwerte" und mit Temperaturbereich im Untermenue "Werkskonfiguration" vergleichen. siehe oben NAMUR-Geber überprüfen oder Geberstrom messen Undervoltage alarm Ausgangs-Impulswert zu klein. CALEC wird in Überlast betrieben. RTC Daten unplausibel Programmierung passt nicht zur Options-Hardware z.B. Energie-Imp. bei 2AOU bis V103, ab V104 Fehlermeldung Relais Ausgangs-Impulswert zu klein overflow. Registerüberlauf bei Relaismomentane Leistung bzw. Durchfluss zu gross, Impulsfunktion Überlastbetrieb Alarm bei Unterspannung TP10/2<11.7V Spannung am Kleinspannungseingang zu klein Spannung überprüfen 16...24VDC oder 12...18VAC 50/60Hz Overvoltage alarm Alarm bei Überspannung TP10/2>35V Spannung am Kleinspannungseingang zu gross Spannung überprüfen 16...24VDC oder 12...18VAC 50/60Hz Serial EEPROM alarm! Overflow alarm Probleme bei EEPROM auslesen Zu hohe Leistung oder Durchfluss Gerätefehler Bei mehr als 40 Zählschritten pro Messzyklus in d e r E n e r g i e a n z e i g e o d e r w e n n µP n i c h t m e h r nachkommt Gerätefehler Gerät zur Reparatur einsenden Fehlermeldung erlischt nur bei Q=0 oder wenn Spannungsversorgung unterbrochen wird. Gerät zur Reparatur einsenden Probleme bei RAM auslesen Gerätefehler Gerät zur Reparatur einsenden EPROM/FLASH alarm! Probleme bei FlashEPROM auslesen Gerätefehler Analogic input MB kann Optionskarte 2 AIN nicht ansprechen O p t i o n s k a r t e 2 A I N n i c h t v o r h a n d e n o d e r d e f e k t Option Alarm Backup alarm (ab V104) RAM alarm! Mit CALTOOL oder MBUSTOOL Impulswert vergrössern. Momentane Leistung oder Durchfluss überprüfen. Datum und Uhrzeit kontrollieren. Optionskarte(n) nicht vorhanden oder vertauscht. Kontrolle mittels Untermenue "Feldkonfiguration". Mit CALTOOL oder MBUSTOOL Impulswert vergrössern. Momentane Leistung oder Durchfluss überprüfen. Gerät zur Reparatur einsenden 3-168-d2 Option overflow (ab V104) Gerät zur Überprüfung einsenden Dieser Alarm kann mit dem Produktionsprogramm aktiviert bzw. unterdrückt werden. VD 3-168 DEF 16 Aquametro AG 10. Technische Daten Wärmezähler-Rechenwerk Temperatur-Messbereich Temperaturdifferenzbereich Amtl. zulässiger Messbereich Zugelassener Temperaturdifferenzbereich T 0°C ∆T 0 T 5°C ∆T 3 Temperaturfühler Typ, Anschlussart Fühlerkabellängen Pt100 nach IEC 751, Zwei- oder Vierleitertechnik geprüft bis 15 m Energieanzeigeeinheit Anzeigekapazität Max. thermische Leistung kWh - MWh | MJ - GJ 99’999’999 30’000 MW / GJ/h Volumenanzeigeeinheit Anzeigekapazität Mess- und Berechnungsintervall Betriebsdauer zwischen Revisionen m3 oder Ml (Megaliter) 99’999’999 ~ 2 sec. 10 Jahre Rechenwerk-Genauigkeitsklasse Max. Mess- und Berechnungsfehler EN 1434-1 / OIML Cl. 4 ≤ 0.5% bei ∆T ≥ 3K, typ. 0,3% Speisung und Schnittstellen Netzanschluss Speisung über AMBUS-Netz Kommunikationsschnittstelle am Gehäusedeckel Kommunikationsschnittstelle an M-Bus-Anschlussklemmen 230 V (+10-15%) 50 Hz, 15 VA, schutzisoliert 16...24 V DC oder 12...18 V AC 50/60Hz Optische Schnittstelle gemäss EN 1434-3, mit M-Bus-Protokoll M-Bus-Protokoll nach EN 1434-3 (IEC 870-5), galvanisch getrennt Gehäuse, Umgebungsbedingungen Wandgehäuse Umgebungsschutzklasse Umgebungstemp.-bereich, Umgebungsklasse Lagertemperaturbereich zur Montage auf DIN-Schiene oder Dreilochbefestigung IP 54 5 ... 55°C, EN 1434 Class “C“ -20 ... 65°C Aquametro AG ... ... ... ... 200°C 200 K 180°C 175 K 17 VD 3-168 DEF Durchflusseingang Durchfluss-Impulseingang für - Kontaktgeber - Open Collector-Geber - Namur-Geber (DIN 19234) - Aktive Impulsgeber über den Optokopplereingang Impulsdauer Impulsdauer Impulsdauer Impulsdauer Programmierbare Impulswertigkeiten 0.001 ml ... 100 m3 mit einer Auflösung von 0.001 ml Durchfluss-Analogeingang (Option) 0...20 mA oder 4...20 mA, linearer Signalverlauf Eingangswiderstand 120 Ω, keine galvanische Trennung 1 0 0 ' 0 0 0 m 3/ h kaltseitig oder warmseitig Maximaler Durchflusswert Einbauort des Durchflussmessers ≥ ≥ ≥ ≥ 25 ms 2.5 ms 2.5 ms 50 µs, max. 10 kHz, 5...30 V, ≥ 5 mA 2. Durchfluss- oder Steuereingang (optional) Steuereingang EIN AUS aktives Signal über Optokopplereingang 5...30 V, ≥ 5 mA, mit geschlossenem Kontakt kein aktives Signal, mit offenem Kontakt Durchfluss-Impulseingang für - Kontaktgeber - Open Collector-Geber - Namur-Geber (DIN 19234) - Aktive Impulsgeber über den Optokopplereingang max. 50 Hz, max. 50 Hz, max. 50 Hz, Impulsdauer Programmierbare Impulswertigkeiten 0.001 ml ... 100 m3 mit einer Auflösung von 0.001 ml Durchfluss-Analogeingang (Option) 0...20 mA oder 4...20 mA, linearer Signalverlauf Eingangswiderstand 120 Ω, keine galvanische Trennung kaltseitig oder warmseitig (nur bei Option Twin E) Einbauort des Durchflussmessers keine Entprellfunktion mit 64:1 Teiler max. 200 Hz mit 64:1 Teiler max. 200 Hz ≥ 50 µs, mit 64:1 Teiler max. 1000 Hz, 5...30 V, ≥ 5 mA Ausgangsfunktionen (optional) Relaisausgangskarte 2RWC, 2RNC zwei Halbleiterkontakte potentialfrei m a x . W e r t e 5 0 V A C / D C , 1 0 0 m A , R ON ≤ 2 0 Ω , R OFF ≥ 1 M Ω Analogausgangskarte 2AOU galvanisch getrennt, aktiv oder passiv zu betreiben, Ausgangsstrom 0...20 mA oder 4...20 mA Versorgung 5...24 VDC, RL max bei 24 V = 950 Ω 300...9600 Baud Halbduplex, max. Leitungslänge 15 m 300...9600 Baud Halbduplex, max. Leitungslänge 1200 m Schnittstellenkarte RS232 Schnittstellenkarte RS485 VD 3-168 DEF 18 Aquametro AG 11. Hinweis auf Eichpflicht 13. Garantie und Haftung Wärmezähler, welche zur direkten Verrechnung einer physikalischen Menge dienen, sind in den meisten Ländern eichpflichtig, d.h. der amtlichen Kontrolle durch Beglaubigung (Eichung) unterstellt. Beglaubigte Wärmezähler müssen nach Ablauf der Eichgültigkeitsdauer von einer berechtigten Prüfstelle wiederbeglaubigt werden. Für die Einhaltung dieser Vorschrift ist der Betreiber des Wärmezählers verantwortlich. Die Gültigkeitsdauer der Beglaubigung wird durch nationale Eichgesetze geregelt und beträgt in der Regel 5 Jahre. Aquametro garantiert im Rahmen der allgemeinen Verkaufs- und Lieferbedingungen für die Qualität dieses Produktes. Aquametro ist qualitätszertifiziert nach ISO 9001/EN 29001 und ihre Produkte werden nach den aktuellen Normen und den bekannten Richtlinien hergestellt. Aquametro haftet nicht für unsachgemässen Einbau und Betrieb. Deshalb unbedingt: • Einbau- und Bedienungsanleitung beachten! • Gerät nur für den bestimmten Zweck einsetzen. • Zubehör nur verwenden, wenn eine sicherheitstechnisch unbedenkliche Verwendungsfähigkeit vorliegt. • Die Haftung für Installation und Handhabung des Messgerätes geht auf den Eigentümer oder Betreiber über. 12. Einsatzdauer und Wartung Die geplante Gebrauchsdauer des Rechenwerkes bis zur ersten Revision beträgt 10 Jahre. Das Baujahr ist auf dem Typenschild nach der Seriennummer (S/N 3.xxx.xxx/ 96) angebracht und kann auch in der Anzeige unter “Werkskonfiguration” gelesen werden. Das Gerät benötigt keine Wartung. Zur Reinigung nur feuchten Lappen, keine Lösungsmittel verwenden! Aquametro AG 19 VD 3-168 DEF Menue-Übersicht Standardausführung (weitere Menue-Übersichten Seite 21...24) Hauptmenue Untermenue Anzeige bei Impulseingang Anzeige bei Stromeingang (Opt.) IN1 EBS 1.000 L/Imp Kaltseite oder = IN1 Strom 0...20 mA EBS Kaltseite + EH 0002216.1608 kWh VH 00259.425303 m3 E V 00002216. kWh 000259.42 m3 Textfeld Anzeige nur bei Fehler Fehlermeldung Anzeige nur bei Fehler kein Fehler HW Temp Alarm (hot) Enter Exit Enter Exit Enter Exit Enter E 00002216. kWh E 00002216. kWh Exit Stichtag 1 30.06.-- Stichtag 2 30.12.-- Enter P Q Anzeige nur bei Fehler Option Alarm Enter Exit Anzeige nur bei Fehler Overflow Alarm Enter Exit xxxxxxx Alarm Enter Stichtagswerte Enter Momentanwerte 3.759526 MW Temp. ∆T 175.04 K k-Faktor 1.1770 Wh/l/K Datum 18.247 m3/h H 180.0 C 4.9 °C Dichte 1.00068 kg/l Zeit 11.05.98 10.25 Betriebsstundenzähler E x i t xxxxxxxx h Enter 10.25 11.05.98 Edit: Up, Down Data Logger Enter Periode 1 Monat Integr.zeit 15 Min Datum 00 xx.xx.xx Datum Enter 01 4 Infofelder xx.xx.xx Datum Enter 02 4 Infofelder xx.xx.xx Datum Enter 03 4 Infofelder xx.xx.xx Datum Enter 04 xx.xx.xx Datum Enter 05 4 Infofelder 4 Infofelder nur bei Impulseingang nur bei Stromeingang (Opt.) xx.xx.xx Datum Enter 06 4 Infofelder xx.xx.xx Datum Enter 07 4 Infofelder xx.xx.xx Datum Enter 08 4 Infofelder xx.xx.xx Datum Enter xx 4 Infofelder xx.xx.xx Datum Enter 14 4 Infofelder Werkskonfiguration Enter Fabr.Nr. 03784829 Fabr.Datum 31.05.97 CALEC MB Ver. 200 Fluid Nr. 000 Wärmerechner Wasser Temp.fühler Pt100 T 0...200 °C Enter Datum xx.xx.xx E 00002216. kWh Datum xx.xx.xx V 000259.42 m3 nur bei Stromeingang (Opt.) IN1 Impuls xxxxxxx IN1 Strom 0...20mA Einbauort Kl. 10/11 Enter Kl. 10/11 Enter xx.xx.xx Exit Enter Vol.geber Schl.mengenunterdr. Schl.mengenunterdr. Exit Kaltseite Q 0.000 m3/h ∆T 0.00 °C Enter Impulswert 1.0000 l 20mA->30.000 m3/h Max.Frequenz 200 Hz linear Zeit 00:00 xx.xx.xx P 3.759526 MW Zeit 00:00 xx.xx.xx Q 18.247 m3/h Exit Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Funktion xxxxxx OUT3 Enter Kl. 70/71 Funktion xxxxxx OUT4 Enter Kl. 72/73 Funktion xxxxxx OUT5 Enter Kl. 74/75 Funktion xxxxxx OUT6 Enter Kl. 76/77 Funktion xxxxxx OUT7 Enter Kl. 78/79 Funktion Status-Test Enter nur bei Impulseingang nur bei Stromeingang (Opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 03.56 mA Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# Tasten up + down OK Exit Enter xxxxxx OUT8 Enter Kl. 80/81 Funktion xxxxxx OUT9 Enter Kl. --/-- Funktion Ereignis OUT10 Enter Kl. --/-- Funktion Ereignis M-Bus BAUD = 2400 Enter Kl. 24/25 Adr. 000 Funktion Sprache Deutsch Exit Aendern Enter Exit Enter Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Exit Enter standard-d.eps Feldkonfiguration Enter Diese Anzeigen erscheinen nur wenn vorhanden VD 3-168 DEF 20 Aquametro AG 14. Bedienungsanleitung dazu, um aus der Grundstellung in den hochauflösenden Anzeigemodus zu schalten. Das Geräte wird über 3-Tasten an der Frontplatte bedient. Mit den zwei (Auf) (Ab) -Pfeiltasten wird vorwärts oder rückwärts durch das Menue geblättert. Mit der “Enter”-Taste wird aus der Menueübersicht oder der aktuellen Position in die ausgewählte Funktion verzweigt. Diese Verzweigungspunkte sind fast immer mit dem “ENTER”Text in der Anzeige bezeichnet. Eine Orientierung zur Auffindung der Anzeigewerte finden Sie im beiliegenden Menueübersichtsplan. Abweichungen durch Optionen und Sonderanfertigungen werden sinngemäss angezeigt. 14.1 Beispiel Ich will die Betriebstemperaturen ansehen und befinde mich in der Grundstellung (Anzeige des Energie- und Volumentotals) Einstellung von Datum und Uhrzeit Zeitkorrekturen (zum Nachstellen nach Spannungsausfällen oder Sommer-/Winterzeitumstellung) können einmal pro Monat mit den Bedienungstasten vorgenommen werden. Die Zeiteinstellung erfolgt ausschliesslich über die Minutenanzeige. Eine Beeinflussung des Datumwertes mit den Tasten ist ausgeschlossen. Weitergehende Zeit- und Datumseinstellungen lassen sich nur über die Kommunikationsschnittstelle mit der entsprechenden Software ausführen, sofern diese nicht vom Energieversorger gesperrt wurde. -Taste mehrmals betätigen bis “Momentanwerte” angezeigt wird. -Taste drücken um ins Momentanwertmenue zu gelangen -Taste mehrmals betätigen bis die Temperaturanzeige erscheint Damit ist das Ziel erreicht. Die Anzeige schaltet nach einiger Zeit selbsttätig in die Grundstellung zurück. Soll die Suche fortgesetzt werden, also z.B. die Funktion und Einstellung der ersten Optionskarte eingesehen werden, wie folgt fortfahren: oder -Taste betätigen bis “EXIT” und “ENTER” in der Anzeige erscheint. -Taste drücken um ins Hauptmenue zurück zu gelangen -Taste mehrmals betätigen bis “Feldkonfiguration” angezeigt wird -Taste drücken um ins Feldkonfigurationsmenue zu gelangen -Taste betätigen bis die gewünschte Information erscheint -Taste drücken um im Untermenue weitere Angaben einzusehen Vorgehen für die manuelle Zeitkorrektur Mit Hilfe der Tasten zu “Momentanwerte” bis zur Datum-/UhrzeitAnzeige. Bei der Zeitanzeige -Taste drücken. Jetzt kann mit der oder -Taste, die Zeit in Minutenschritten vor- und nachgestellt werden. Mit der -Taste wird der eingestellte Wert übernommen. Die Eingabe kann am gleichen Tag beliebig wiederholt werden. Nach erfolgtem Datumswechsel kann im laufenden Monat keine weitere Zeiteinstellung mehr vorgenommen werden (Schutz gegen Stichtags- und Tarifmanipulation). Tip: Schnellrücksprung in die Grundstellung: Tasten und gleichzeitig betätigen. Diese Kombination dient auch Aquametro AG 21 VD 3-168 DEF 14.2 14.4 Feldprogrammierbare Daten eingeben Zählerablesung über die Infrarotschnittstelle Alle feldprogrammierbaren Einstellungen, welche den Gebrauch der Optionen erlauben, können mit Hilfe der ”CALTOOL”-Programmiersoftware von Aquametro über eine der Kommunikations-Schnittstellen eingegeben oder verändert werden. Eine Beeinflussung der eigentlichen Wärmemengenmessung ist ausgeschlossen. Die Zählerauslesung über die eingebaute Infrarotschnittstelle erfolgt durch Anlegen eines Infrarot-Datenkopfes (z.B. Aquametro Typ OCI 9600) an der mit IEC 8705 auf der Frontplatte bezeichneten Stelle. Der Auslesekopf wird durch Magnetkraft gehalten. Das Auslesegerät muss mit der geeigneten Software gemäss EN 1434-3 (M-Bus) versehen sein. Für die Einzelauslesung empfiehlt sich die vorgängig erwähnte ”CALTOOL”-Software. Bild-14.eps Achtung: Elektrozähler mit optischer Auslesung funktionieren mit dem älteren ZVEI-Protokoll (IEC 1107)! Die Einleitung der Auslesung erfolgt durch das Handterminal oder den Auslesecomputer. Der Auslesevorgang verändert keine Werte innerhalb des Gerätes. 14.3 Einstellung von Stichtagsdaten, Loggerperiodendauer und Integrationsperiode Mit Hilfe des ”CALTOOL”-Programmes können diese Einstellungen in der Regel frei verändert werden. Im Gegensatz zu den “offenen” Optionsparametern, können diese Einstellungen mit Hilfe der ”CALTOOL”Software vor weiteren Veränderungen geschützt werden (Aktivierung von Lock level 2). Ein abermaliges Verändern kann danach nur noch durch eine Entsperrung erfolgen, welche das Öffnen des Gerätes mit entsprechender Verletzung der Werkplombe erfordert. VD 3-168 DEF Kommunikationsparameter Die Einstellung der Kommunikationsparameter erfolgt mit der ”CALTOOL”-Software. Die Standard-Baudrate des CALEC® MB beträgt 2400 Baud. Auslesegeräte sollten in der Lage sein, mit dieser Geschwindigkeit zu kommunizieren. Für den Betrieb eines Terminalgerätes mit anderer Baudrate ist die CALEC®-Baudrate vorher anzupassen. Achtung: Bei gleichzeitigem Datenzugriff an der Infrarotschnittstelle und einem fest installierten M-Bus-Netz können Synchronisationsprobleme auftreten, welche nur durch einen zeitlich versetzten Zugriff behoben werden können. 22 Aquametro AG 15. Konformitätserklärung 14.5 Sprachwechsel vornehmen Das Gerät wird grundsätzlich viersprachig geliefert. Die Umschaltung zwischen den Sprachen kann über die Bedientasten vorgenommen werden. Vorgehen Mit den Tasten das Menü ”Feldkonfiguration” anwählen und von dort bis zur Sprachanzeige weiterschalten. Jetzt kann mit der oder Taste, die Sprache eingestellt und jeweils mit der -Taste übernommen werden. Der Vorgang kann beliebig wiederholt werden. 14.6 Display Test (Anzeigetest) In dieser Stellung müssen zwei Zeilen à 20 Zeichenfelder mit allen Punkten sichtbar sein. 14.7 M-Busbetrieb Für die M-Bus-Vernetzung gelten die Regeln der M-Bus-Norm EN 1434-3 und die Ergänzungs-Empfehlungen von Aquametro gemäss der technischen Information AMBUS®. Aquametro AG 23 VD 3-168 DEF 16. Anhang: Menu-Übersicht Softwareoptionen Option DTF Hauptmenue Untermenue Anzeige bei Impulseingang Anzeige bei Stromeingang (Opt.) IN1 EBS 1.000 L/Imp Kaltseite oder = IN1 Strom 0...20 mA EBS Kaltseite + EH 0002216.1608 kWh VH 00259.425303 m3 E V 00002216. kWh 000259.42 m3 Et 00002216. kWh Vt 000153.87 m3 EHt 002216.1608 kWh VHt 0153.873500 m3 Textfeld Anzeige nur bei Fehler Fehlermeldung Anzeige nur bei Fehler kein Fehler HW Temp Alarm (hot) Enter Exit Enter Exit Anzeige nur bei Fehler Option Alarm Enter Exit Anzeige nur bei Fehler Enter Exit Overflow Alarm Enter Exit xxxxxxx Alarm Enter Enter E 00000321. kWh Et 00000026. kWh E 00001216. kWh Et 000000104. kWh Exit Stichtag 1 30.06.97 Stichtag 1 30.06.97 Stichtag 2 30.12.97 Stichtag 2 30.12.97 Enter Enter P Q Stichtagswerte Momentanwerte 3.759526 MW Temp. ∆T 175.04 K k-Faktor 1.1770 Wh/l/K Datum 18.247 m3/h H 180.0 C 4.9 °C Dichte 1.00068 kg/l Zeit 11.05.98 10.25 Betriebsstundenzähler E x i t xxxxxxxx h Enter 10.25 11.05.98 Edit: Up, Down Data Logger Enter Periode 1 Monat Integr.zeit 15 Min Datum 00 xx.xx.xx Datum Enter 01 4 Infofelder xx.xx.xx Datum Enter 02 4 Infofelder xx.xx.xx Datum Enter 03 4 Infofelder xx.xx.xx Datum Enter 04 xx.xx.xx Datum Enter 05 4 Infofelder 4 Infofelder nur bei Impulseingang nur bei Stromeingang (Opt.) xx.xx.xx Datum Enter 06 4 Infofelder xx.xx.xx Datum Enter 07 4 Infofelder xx.xx.xx Datum Enter 08 4 Infofelder xx.xx.xx Datum Enter xx 4 Infofelder xx.xx.xx Datum Enter 14 4 Infofelder Werkskonfiguration Enter Fabr.Nr. 03784829 Fabr.Datum 31.05.97 CALEC MB Ver. 200 Fluid Nr. 000 Tarifrechner Wasser Temp.fühler Pt100 T 0...200 °C Vol.geber IN2 Impuls xxxxxxx Schl.mengenunterdr. Schl.mengenunterdr. Exit Kaltseite Kl. 56/57 Enter Q 0.000 m3/h ∆T 0.00 °C Impulswert 1.0000 l 20mA->30.000 m3/h Max.Frequenz 200 Hz linear Enter Datum xx.xx.xx Et 0000942. kWh nur bei Stromeingang (Opt.) IN1 Impuls xxxxxxx IN1 Strom 0...20mA Einbauort Kl. 10/11 Enter Kl. 10/11 Enter xx.xx.xx Exit Enter Datum xx.xx.xx E 00002216. kWh Zeit 00:00 xx.xx.xx 3.759526 MW Enter P Impulswert --/-Tarif switch Zeit 00:00 xx.xx.xx Q 5.942 m3/h Exit Enter Feldkonfiguration Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Funktion xxxxxx OUT3 Enter Kl. 70/71 Funktion xxxxxx OUT4 Enter Kl. 72/73 Funktion xxxxxx OUT5 Enter Kl. 74/75 Funktion xxxxxx OUT6 Enter Kl. 76/77 Funktion xxxxxx OUT7 Enter Kl. 78/79 Funktion Status-Test Enter nur bei Impulseingang nur bei Stromeingang (Opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 03.56 mA Tarif2: on/off t = 00000358 s Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# Tasten up + down OK Exit Enter xxxxxx OUT8 Enter Kl. 80/81 Funktion xxxxxx OUT9 Enter Kl. --/-- Funktion Ereignis OUT10 Enter Kl. --/-- Funktion Ereignis M-Bus BAUD = 2400 Enter Kl. 24/25 Adr. 000 Funktion Sprache Deutsch Exit Aendern Enter Exit Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Exit Enter Diese Anzeigen erscheinen nur wenn vorhanden VD 3-168 DEF 24 Aquametro AG Enter Option ISPC Hauptmenue Untermenue Anzeige bei Impulseingang Anzeige bei Stromeingang (Opt.) IN1 EBS 1.000 L/Imp Kaltseite oder = IN1 Strom 0...20 mA EBS Kaltseite + EH1 002216.1608 kWh VH1 0259.425303 m3 E1 00002216. kWh V1 000259.42 m3 VH2 0153.873500 m3 V2 000153.87 m3 Textfeld Anzeige nur bei Fehler Fehlermeldung Anzeige nur bei Fehler kein Fehler HW Temp Alarm (hot) Enter Exit Enter Exit Anzeige nur bei Fehler Option Alarm Enter Exit Anzeige nur bei Fehler Enter Exit Overflow Alarm Enter Exit xxxxxxx Alarm Enter Enter E1 00000321. kWh V2 00000026. m3 E1 00001216. kWh V2 000000104. kWh Exit Stichtag 1 30.06.97 Stichtag 1 30.06.97 Stichtag 2 30.12.97 Stichtag 2 30.12.97 Enter Enter P Q Stichtagswerte Momentanwerte 3.759526 MW 18.247 m3/h Q2 6.735 m3/h Temp. ∆T 175.04 K k-Faktor 1.1770 Wh/l/K Datum H 180.0 C 4.9 °C Dichte 1.00068 kg/l Zeit 11.05.98 10.25 Betriebsstundenzähler E x i t xxxxxxxx h Enter 10.25 11.05.98 Edit: Up, Down Data Logger Enter Periode 1 Monat Integr.zeit 15 Min Datum 00 xx.xx.xx Datum Enter 01 4 Infofelder xx.xx.xx Datum Enter 02 4 Infofelder xx.xx.xx Datum Enter 03 4 Infofelder xx.xx.xx Datum Enter 04 xx.xx.xx Datum Enter 05 4 Infofelder 4 Infofelder nur bei Impulseingang nur bei Stromeingang (Opt.) xx.xx.xx Datum Enter 06 4 Infofelder xx.xx.xx Datum Enter 07 4 Infofelder xx.xx.xx Datum Enter 08 4 Infofelder xx.xx.xx Datum Enter xx 4 Infofelder xx.xx.xx Datum Enter 14 4 Infofelder Werkskonfiguration Enter Fabr.Nr. 03784829 Fabr.Datum 31.05.97 CALEC MB Ver. 200 Fluid Nr. 000 ISPC Rechner Wasser Temp.fühler Pt100 T 0...200 °C Vol.geber IN2 Impuls xxxxxxx Schl.mengenunterdr. Schl.mengenunterdr. Exit Kaltseite Kl. 56/57 Enter Q 0.000 m3/h ∆T 0.00 °C Impulswert 1.0000 l 20mA->30.000 m3/h Max.Frequenz 200 Hz linear Enter Datum xx.xx.xx V1 000059.42 m3 nur bei Stromeingang (Opt.) IN1 Impuls xxxxxxx IN1 Strom 0...20mA Einbauort Kl. 10/11 Enter Kl. 10/11 Enter xx.xx.xx Exit Enter Datum xx.xx.xx E1 00002216. kWh Zeit 00:00 xx.xx.xx 3.759526 MW Enter P Impulswert 1.0000 l Max.Frequenz 50 Hz Zeit 00:00 xx.xx.xx Q 18.247 m3/h Exit Enter Feldkonfiguration Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Funktion xxxxxx OUT3 Enter Kl. 70/71 Funktion xxxxxx OUT4 Enter Kl. 72/73 Funktion xxxxxx OUT5 Enter Kl. 74/75 Funktion xxxxxx OUT6 Enter Kl. 76/77 Funktion xxxxxx OUT7 Enter Kl. 78/79 Funktion Status-Test Enter nur bei Impulseingang nur bei Stromeingang (Opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 03.56 mA IN 2 f = 0.00 Hz t = 00000358 s Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# Tasten up + down OK Exit Enter xxxxxx OUT8 Enter Kl. 80/81 Funktion xxxxxx OUT9 Enter Kl. --/-- Funktion Ereignis OUT10 Enter Kl. --/-- Funktion Ereignis M-Bus BAUD = 2400 Enter Kl. 24/25 Adr. 000 Funktion Sprache Deutsch Exit Aendern Enter Exit Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Exit Enter Diese Anzeigen erscheinen nur wenn vorhanden Aquametro AG 25 VD 3-168 DEF Enter Option BDE und BDV Hauptmenue Untermenue Anzeige bei Impulseingang Anzeige bei Stromeingang (Opt.) IN1 EBS 1.000 L/Imp Kaltseite oder = IN1 Strom 0...20 mA EBS Kaltseite + EH+ 02216.1608 kWh VH+ 0259.425303 m3 E+ 00002216. kWh V+ 000259.42 m3 E- 00002216. kWh V- 000153.87 m3 EH- 02216.1608 kWh VH- 0153.873500 m3 Textfeld Anzeige nur bei Fehler Fehlermeldung Anzeige nur bei Fehler kein Fehler HW Temp Alarm (hot) Enter Exit Enter Exit Anzeige nur bei Fehler Option Alarm Enter Exit Anzeige nur bei Fehler Enter Exit Overflow Alarm Enter Exit xxxxxxx Alarm Enter Enter E+ 00000321. kWh E- 00000026. kWh E+ 00001216. kWh E- 00000104. kWh Exit Stichtag 1 30.06.97 Stichtag 1 30.06.97 Stichtag 2 30.12.97 Stichtag 2 30.12.97 Enter Enter P Q Stichtagswerte Momentanwerte 3.759526 MW Temp. ∆T 175.04 K k-Faktor 1.1770 Wh/l/K Datum 18.247 m3/h H 180.0 C 4.9 °C Dichte 1.00068 kg/l Zeit 11.05.98 10.25 Betriebsstundenzähler E x i t xxxxxxxx h Enter 10.25 11.05.98 Edit: Up, Down Data Logger Enter Periode 1 Monat Integr.zeit 15 Min Datum 00 xx.xx.xx Datum Enter 01 4 Infofelder xx.xx.xx Datum Enter 02 4 Infofelder xx.xx.xx Datum Enter 03 4 Infofelder xx.xx.xx Datum Enter 04 xx.xx.xx Datum Enter 05 4 Infofelder 4 Infofelder nur bei Impulseingang nur bei Stromeingang (Opt.) xx.xx.xx Datum Enter 06 4 Infofelder xx.xx.xx Datum Enter 07 4 Infofelder xx.xx.xx Datum Enter 08 4 Infofelder xx.xx.xx Datum Enter xx 4 Infofelder xx.xx.xx Datum Enter 14 4 Infofelder Werkskonfiguration Enter Fabr.Nr. 03784829 Fabr.Datum 31.05.97 CALEC MB Ver. 200 Fluid Nr. 000 BDE Rechner Wasser oder Temp.fühler Pt100 T 0...200 °C BDV Rechner V o l . g e b e r IN2 Impuls xxxxxxx S c h l . m e n g e n u n t e r d r . S c h l . m e n g e n u n t e r d r . E x i t Enter Q 0.000 m3/h ∆T 0.00 °C K a l t s e i t e Kl. 56/57 Impulswert 1.0000 l 20mA->30.000 m3/h Max.Frequenz 200 Hz linear Enter Datum xx.xx.xx E- 0000942. kWh nur bei Stromeingang (Opt.) IN1 Impuls xxxxxxx IN1 Strom 0...20mA Einbauort Kl. 10/11 Enter Kl. 10/11 Enter xx.xx.xx Exit Enter Datum xx.xx.xx E+ 00002216. kWh Zeit 00:00 xx.xx.xx 3.759526 MW Enter P Impulswert --/-Tarif switch Zeit 00:00 xx.xx.xx P1.238545 MW Exit Enter Feldkonfiguration Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Funktion xxxxxx OUT3 Enter Kl. 70/71 Funktion xxxxxx OUT4 Enter Kl. 72/73 Funktion xxxxxx OUT5 Enter Kl. 74/75 Funktion xxxxxx OUT6 Enter Kl. 76/77 Funktion xxxxxx OUT7 Enter Kl. 78/79 Funktion Status-Test Enter nur bei Impulseingang nur bei Stromeingang (Opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 03.56 mA Durchfluss : positiv Lock level 1 Exit t = 00000358 s M-Bus access 0002134 Enter ################# ################# Tasten up + down OK Exit Enter xxxxxx OUT8 Enter Kl. 80/81 Funktion xxxxxx OUT9 Enter Kl. --/-- Funktion Ereignis OUT10 Enter Kl. --/-- Funktion Ereignis M-Bus BAUD = 2400 Enter Kl. 24/25 Adr. 000 Funktion Sprache Deutsch Exit Aendern Enter Exit Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Exit Enter Diese Anzeigen erscheinen nur wenn vorhanden Diese Anzeigen sind nur bei Option BDV vorhanden VD 3-168 DEF 26 Aquametro AG Enter Option Twin E und Twin V Hauptmenue Untermenue Anzeige bei Impulseingang Anzeige bei Stromeingang (Opt.) IN1 EBS 1.000 L/Imp Kaltseite oder = IN1 Strom 0...20 mA EBS Kaltseite + EH1 02216.1608 kWh VH1 0259.425303 m3 E1 00002216. kWh V1 000259.42 m3 E2 00002216. kWh V2 000153.87 m3 EH2 02216.1608 kWh VH2 0153.873500 m3 Textfeld Anzeige nur bei Fehler Fehlermeldung Anzeige nur bei Fehler kein Fehler HW Temp Alarm (hot) Enter Exit Enter Exit Anzeige nur bei Fehler Option Alarm Enter Exit Anzeige nur bei Fehler Enter Exit Overflow Alarm Enter Exit xxxxxxx Alarm Enter Enter E 1 0 0 0 0 0 3 2 1 . k W h E2 00000026. kWh E 1 0 0 0 0 1 2 1 6 . k W h E2 00000104. kWh E x i t S t i c h t a g 1 3 0 . 0 6 . 9 7 Stichtag 1 30.06.97 S t i c h t a g 2 3 1 . 1 2 . 9 7 Stichtag 2 31.12.97 Enter Enter P Q Stichtagswerte Momentanwerte 3.759526 MW P2 18.247 m3/h Q2 0.975246 MW Temp. ∆T 175.04 K k-Faktor 1.1770 Wh/l/K Datum 4.682 m3/h H 180.0 C 4.9 °C Dichte 1.00068 kg/l Zeit 11.05.98 10.25 Betriebsstundenzähler E x i t xxxxxxxx h Enter 10.25 11.05.98 Edit: Up, Down Data Logger Enter Periode 1 Monat Integr.zeit 15 Min Datum 00 xx.xx.xx Datum Enter 01 4 Infofelder xx.xx.xx Datum Enter 02 4 Infofelder xx.xx.xx Datum Enter 03 4 Infofelder xx.xx.xx Datum Enter 04 xx.xx.xx Datum Enter 05 4 Infofelder 4 Infofelder nur bei Impulseingang nur bei Stromeingang (Opt.) xx.xx.xx Datum Enter 06 4 Infofelder xx.xx.xx Datum Enter 07 4 Infofelder xx.xx.xx Datum Enter 08 xx.xx.xx Datum Enter 09 xx.xx.xx Datum Enter 10 4 Infofelder 4 Infofelder 4 Infofelder nur bei Stromeingang 2 (Opt.) nur bei Stromeingang 2 (Opt.) nur bei Stromeingang 2 (Opt.) xx.xx.xx Datum Enter xx 4 Infofelder xx.xx.xx Datum Enter 14 Werkskonfiguration Enter Fabr.Nr. 03784829 Fabr.Datum 31.05.97 CALEC MB Ver. 200 Fluid Nr. 000 Twin-E Rechner Wasser Temp.fühler Pt100 T 0...200 °C oder Twin V Rechner IN1 Impuls xxxxxxx IN1 Strom 0...20mA Einbauort Kl. 10/11 Enter Kl. 10/11 Enter Datum xx.xx.xx nur bei Twin-V V 00000942. m3 Vol.geber IN2 Impuls xxxxxxx IN2 Strom 0...20mA Schl.mengenunterdr. Schl.mengenunterdr. Schl.mengenunterdr. Exit Kaltseite Kl. 56/57 Enter Kl. 56/57 Enter Q 1.000 m3/h Q2 0.000 m3/h ∆T 0.00 °C Impulswert 1.0000 l 20mA->30.000 m3/h Max.Frequenz 200 Hz linear xx.xx.xx Exit Enter Enter Datum xx.xx.xx E1 00002216. kWh 4 Infofelder Datum xx.xx.xx nur bei Twin-E E n t e r E2 00000942. kWh Impulswert 1.000 l 20mA->24.000 m3/h Max.Frequenz 50 Hz linear Zeit 00:00 xx.xx.xx P1 3.759526 MW Zeit 00:00 xx.xx.xx nur bei Twin-V Q 1.238545 m3/h Zeit 00:00 xx.xx.xx nur bei Twin-E P2 1.238545 MW Feldkonfiguration Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Funktion xxxxxx OUT3 Enter Kl. 70/71 Funktion xxxxxx OUT4 Enter Kl. 72/73 Funktion xxxxxx OUT5 Enter Kl. 74/75 Funktion xxxxxx OUT6 Enter Kl. 76/77 Funktion xxxxxx OUT7 Enter Kl. 78/79 Funktion xxxxxx OUT8 Enter Kl. 80/81 Funktion Status-Test Enter nur bei Impulseingang nur bei Stromeingang (Opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 12.16 mA nur bei Stromeingang 2 (Opt.) IN 2 f = 0.00 Hz t = 00000358 s IN2 I = 7.12 mA Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# xxxxxx OUT9 Enter Kl. --/-- Funktion Tasten up + down OK Exit Enter Ereignis OUT10 Enter Kl. --/-- Funktion Ereignis M-Bus BAUD = 2400 Enter Kl. 24/25 Adr. 000 Funktion Sprache Deutsch Exit Aendern Enter Exit Exit Enter Enter Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Exit Enter Diese Anzeigen erscheinen nur wenn vorhanden Diese Anzeigen sind nur bei Option Twin E vorhanden Aquametro AG 27 VD 3-168 DEF 1. Product description and packaging 1.1 Point of installation The CALEC® MB heat calculator is a component of a heat meter which allows precise measurement of heat energy consumption. Designed, manufactured and tested with great care by Aquametro engineers, this unit is certified by the calibration authorities in compliance with current requirements and standards. • • • • • Please help to ensure a long reliable service of this heat meter by carefully installing it according to the instructions. easily accessible for installation, reading and servicing well protected and dry as possible protected against heat and exposure to sunlight takes account of available or allowed sensor cable lengths observe recommended distance away from sources of strong electrical interference Installation of the calculator, flow and temperature sensors must comply with the regulations and recommendations of the heat meter standard EN1434, Part 6. The separate flow sensor must be securely connected to the calculator and the pulse value indicated on the heat calculator must strictly correspond to that on the flow sensor. Temperature sensors must be installed and connected according to the manufacturer’s data. Packaging contents: 1 CALEC® MB heat calculator 1 DIN standard 35mm mounting rail 1 accessory pouch containing: 4 metal jumpers for 2-wire sensor connections various small and large blanket plugs 4 red sealing studs 2 sealing stickers 1 list of above accessories 1 Installation and operating manual Caution Do not remove or damage any calibration or factory seals! 1.2 Installation instructions Remove the top cover by releasing the 4 Phillips screws. Separate the cover from the base by carefully pulling out the ribbon cable plug and keep in a safe place until connection work is finished (Pull out the ribbon VD 3-168 DEF 28 Aquametro AG Bild-2.eps cable plug squarely by holding it on both sides). Be sure to reinsert the plug before applying the mains supply! Snap the housing base onto the 35mm-DIN rail, or fix it to the wall with the three panhead wood screws (5 x 30, no countersunk-head screws) as shown in the drawing on page 2. The top screw serves as a suspension point. For installation in front panels, a prefabricated mounting kit (as depicted on page 2) is available. The mounting kit (MPM) includes a rubber gasket which surrounds the calculator. For replacement of existing panel mounted CALEC® MCL/ MCP models, a conversion kit (CPM) is available. 1.4 Cable inserts For correct installation 9 cable ports are provided as follows: Pos. A 1 x PG 11 for mains power cable (Ø 5...10mm) Pos. B 1 x PG 13 for control cable (Ø 6...12mm); could be used for a common extension of temperature sensor and pulser wires. Pos. 1...7 7 x PG 7 for individual cables (Ø 2...5mm): used for temperature sensors, pulser and other signal cables required by the output options. A 1 3 5 7 2 6 For correct tightening of the closely spaced cable ports, use a slotted socket key of 15mm (see figure). B Any unused cable ports should be sealed off with the help of the cover (blanket) caps provided. 1.3 Protection class assurance Bild-5.eps The protection class IP54 is only assured with unbroken fixing holes. The user is responsible for compliance with the required protection class and for faultless installation. This also applies to cable inserts: use only wellfitting cables and tight rubber seals. Aquametro AG 29 VD 3-168 DEF 2. Connecting the power supply Insert the mains cable (Ø 5...10mm) through the left hand (Pos.A) PG11 cable port and tighten firmly. For practical reasons the power cables must not be looped. If no power cable is introduced, fit the cover cap (included in the accessory pouch) into the empty cable port. The unit can be operated either with a 230VAC power supply or with the AMBUS® low voltage network, depending on the measuring concept. All connections must be made according to the enclosed wiring diagramme. Terminal numbers up to 50 correspond to the EN1434 heat meter standard. Small voltage supply or N 230 V / 50 Hz mains connection 2.1 61 25 24 60 e.x..4x0.8 15VAC MeterAMBUS .Bus 66117ge.eps Phase L Null Mains connections must be made by trained and authorised personnel only! Local safety regulations must be observed. Connection to terminals other than L+N is extremely dangerous and will permanently damage the equipment. 230 V mains connections 2.2 The mains supply must be adequately protected against unauthorised interruption. The heat meter must be protected according to the latest state of technology to ensure safe shutdown in case of electrical failure. The safety fuse must be limited to max. 10A. Low voltage connections (15V) to the centralised M-Bus power supply Connect the meter to a separate fuse or to the heating control circuit. The calculator is fully isolated and requires no grounding connections. Connect mains power to the terminals marked L + N. All other terminals are strictly reserved for low voltage (< 50V) and measuring signals only. This low voltage power supply is used for restricted operation if no mains supply is available. When used in conjunction with an AMBUS® central unit, this power supply together with the 2-wire M-Bus cable connected to the CALEC® provides a reliable system for communications. If no bus cable is introduced, cover the empty cable port with the cap provided. In Germany, the device has been approved for operation with 230 V supply only. VD 3-168 DEF 30 Aquametro AG 3. Wiring diagrams Connection with 2 relay outputs and pulse counter input (ISPC) Live Warmseite Hot side Côté chaud OUT 3 OUT 4 7370 71 72 + + - Kaltseite Cold side Côté froid AM066117ee1 + Impulsgeber Flow sensor Débitmètre 64 65+ Neutral 2RWC or. 2RNC OUT 1 OUT 2 50 51 52 53 Option card 2 e.g. DTF Input 2 2RWC or 2RNC or 2AOU OUT 3 OUT 4 56 57- 7370 71- 72 + + + AM066117ee2 + - Mains connection 230 V / 50 HZ Aux. voltage 18 V DC / 100mA Netzanschluss Mains supply Alimentation réseau 230V/50Hz 64 65 Nulleiter / Neutral / Neutre Phase / Line / Phase Aquametro AG 60 61 24 25 Hilfsspannungsausgang Auxiliary voltage output Sortie de tension auxiliaire 18VDC L N Optionskarte 2 Option card 2 Carteoption 2 OUT3 OUT4 OUT1 OUT2 Optionskarte 1 Option card 1 Carteoption 1 50 51 52 53 + - + 70 71 72 73 L N M-Bus M-Bus Kleinspannungsversorung Low voltage connection Alimentation basse tension 50 51 52 53 e.g. ISPC Input 2 (IN 2) 56 57 Option card 1 Live Option IN2 OUT 2 Mains connection 230 V / 50 HZ Emetteur d'imp. ou entrée tarif OUT5 OUT6 Optionskarte 3 Option card 3 Carteoption 3 + - + 74 75 76 77 Durchfluss / Flow / Débit 64 65 OUT 1 Option card 2 Control and tariff input (DTF) connection, controlled by internal relay + Durchflussgeber oder Tarifeingang Flow sensor or tariff input 1 5 6 2 3 7 8 4 Eingang 1 / Input 1/ Entrée 1 IN1 10 11 Source Sense Sense + Source + 56 57 OUT7 OUT8 Optionskarte 4 Option card 4 Carteoption 4 + - + 78 79 80 81 Anschlüsse Connections Connexions Source Sense Sense + Source + Aux. voltage 18 V DC / 100mA L N AM066103.4 Wärmerechner Heat calculator CALEC MB Calculateur de chaleur Neutral Option card 1 Wiring diagram for CALEC® MB 31 VD 3-168 DEF Connection variants of the analogue outputs Passive analogue outputs (jumper on passive) 64 65 L N OUT 1 OUT 2 50 51 52 53 OUT 3 Warning: Inverted polarity! Option card 1 (2AOU) OUT 4 73 70 71 72 + + - Neutral Aux. voltage 18 V DC / 100mA Option card 2 (2AOU) Live Neutral Live Option card 1 (2AOU) Active analogue outputs (jumper on active) Aux. voltage 18 V DC / 100mA 64 65 L N - DC 5...24 V - AM066117ee3 OUT 2 50 51 52 53 + Mains connection 230 V / 50 HZ OUT 1 + - + Option card 2 (2AOU) OUT 3 - Neutral Live L N Aux. voltage 18 V DC / 100mA max. 64 65 OUT 1 OUT 2 50 51 52 53 - + AM066117ee5 Option card 2 (2AOU) OUT 3 + Mains connection 230 V / 50 HZ Active analogue outputs (jumper on passive) Option card 1 (2AOU) OUT 4 7370 71- 72 + + Jumper on optional modules 2AOU: OUT 4 7370 71- 72 + + 1 6 Mains connection 230 V / 50 HZ Rv AM066117ee4 active Maximum Load: R V max = (Us-5)/0.02A Us = 24V VD 3-168 DEF passive Example: (24V-5V) / 0.02A = 950Ω 32 Aquametro AG 4. Connecting the temperature sensor pair Direct connection ( Fig. a). Suitable for the original uncut sensor cable! Recommanded connections cable sensor directly connected 57 11 56 4 10 8 3 cable sensor with 4- wire connection 2 7 Attention 6 1 57 5 11 56 4 10 8 3 head sensor with 4- wire connection 2 7 6 1 57 11 56 5 4 8 10 3 7 2 Important: The original cable lengths must never be shortened because the wire resistance is always added to the temperature sensor resistance. cable sensor with 2- wire extension 6 57 5 1 11 56 4 10 8 3 2 7 6 1 5 d) c) b) a) VD-30 PLH85/100 PLH120/100 TPK1121..21..31 hot side sensor types: cold side hot side cold side hot side cold side sensor types: PLC85/100/2 PLC120/100/2 PLC210/100/2 DS100 This type of connection is preferred, especially if the original cable length is too short for direct connection (see Fig. a). hot side cold side VD-30 4-wire extension (Figs. b and c) For each sensor, cable extensions must be made with a secure wire connection (e.g. pressfit) using 4-wire telephone cables (4 x 0,8Ø) as indicated in the wiring diagrammes b) or c). 2-wire extensions (Fig. d) should be avoided whenever possible because of the high risk of unbalanced resistances. 66117B Aquametro AG 33 VD 3-168 DEF IN 1 11 - 5. Connecting the flow transmitter 4 10 2 8 3 7 1 + Flow transmitter Four different types of volumetric pulsers can be connected to the input for the flow transmitter (IN1: terminals 10 + 11). 57 6 11 10 56 5 - 4 2 8 3 6 1 7 5 + 2nd flow transmitter or Tariff input 66117ce.eps 57 56 Compared to the temperature sensors, wiring of the flow transmitter signal input is less critical. A cable of 2 x 0,8 Ø is recommended. Passive pulsers allow sharing of a common extension cable with the temperature sensors. An alternative second input (IN2) is connected to terminals 56/57. The functionality depends on the specific version (e.g. DTF, ISPC, etc.). • Mechanical reed or relay contacts • Electronic pulsers complying with DIN 19234 (Namur) and ”open collector”circuits (Note the correct polarity shown on the wiring diagramme!) • Active pulsers. An external power source delivers the required pulse current to the galvanically isolated output. • Analogue: the flow is vonverted into a 0/4...20 mA current signal. Changing from passive to active input can be made (even on-site) by resetting the jumpers near the connection terminals. The neccessary settings are shown on the stick-on connection diagramme. (This step is only required when the installed pulser type does not correspond to the specifications given with the order). Important Flow meters may deliver pulses with very different pulse values! Only combine subunits with the same pulse value (Litres per pulse)! Debouncing If the unit is set up for mechanical pulsers, the input is fitted with a debouncing filter. This cannot be altered without reprogramming the unit. Changing the original pulse value is strictly forbidden by law if the meter is being used for accounting purposes. This also applies to changing the flow sensor position from the cold to the hot side (or vice versa) and disabling the debounce filter. VD 3-168 DEF OPTION IN 2 Flow Sensor installation The temperature sensors are installed in compliance with EN1434 either directly immersed (inside a ball valve), or contained within sleeves in the supply and return pipes. The installation must be done with the maximum care since it is the most important criterium for attaining the required accuracy. 34 Aquametro AG Relay output 50+52 70+72 74+76 78+80 Analogue output max.100mA/50V RL The standard CALEC® MB is fitted with an M-Bus-interface in compliance with EN1434-3. This allows all relevant parameters to be selected and all output functions to be programmed. The polarity independent connection is made to terminals 24 / 25. OUT 1 to 8 50+52 70+72 74+76 78+80 0/4 .. 20 mA + AC or DC 51+53 71+73 75+77 79+81 RV OUT 1 to 8 51+53 71+73 75+77 79+81 DCSource - 66117de.eps 6. Output signals Electric insulation The passive analogue outputs are galvanically isolated from each other. The active outputs are connected via common earth. They are galvanically connected with the auxiliary voltage and the option cards, but galvanically isolated from the rest of the electronics. The available option cards are connected, as indicated in the wiring diagramme, to terminals 50 ..53 (socket 1), 70 .. 73 (socket 2), 74 .. 77 (socket 3) and 78...81 (socket 4). Depending on the particular type of card inserted, the following are available per card: two contact power circuits, two analogue power circuits, one RS232 interface or one RS 485 interface. The identification of an inserted card, its function, setup and terminals are indicated in the display menu under ”Field configuration” (e.g. OUT 1Relay- Kl. 50/51 - Pulse energy1 - pulse value 1 kWh). Load resistance When using the internal auxiliary power output, the maximum load resistance of all analogue circuits must not exceed the following value: If an option terminal number is not known and no installation wiring diagramme is available, a readout of the terminals and functions as mentioned above may be helpful after switching on the unit. R V max = (Us-5)/0.02 A Otherwise, all analogue outputs should be supplied with a highercapacity external power source. Important: Never remove or insert option cards with the power on. This may lead to loss of meter data! Relay output 2 solid state relays are available per option card 2RNC or 2 RWC, which have a maximum permitted load of 10 mA AC or DC at max. 50 V. Analogue output Each power circuit can be individually configured as an active or passive analogue output. The active outputs are powered by the internal auxiliary voltage supply at a maximum of 100 mA. Aquametro AG 35 VD 3-168 DEF RS232 Communications interface The interface is powered by the auxiliary supply and it is galvanically isolated from the calculator. The signals for GND, TXD and RXD are available at the connection terminals. A signal of +10V (which can be used as DTR or RTS) is applied at a fourth terminal. The protocol used is identical to the M-Bus protocol defined in EN 1434-3:1997 and IEC 870-5. It supports 300 to 9600 baud. Half-duplex communication is used; however, transmissions and reception use separate channels. RS232 TXD RXD GND +10V Socket 1 Term. 50 Term. 51 Term. 52 Term. 53 Socket 2 Term. 70 Term. 71 Term. 72 Term. 73 Socket 3 Term. 74 Term. 75 Term. 76 Term. 77 Socket 4 Term. 78 Term. 79 Term. 80 Term. 81 VD 3-168 DEF RS485Communications interface The interface is powered by the auxiliary supply and it is galvanically isolated from the calculator. The protocol used is identical to the M-Bus protocol defined in EN 1434-3:1997 and IEC 870-5. It supports 300 to 9600 baud. Half-duplex communication is used. Transmissions and reception use the same channel. RS485 36 B+ B- Socket 1 Term. 50 Term. 51 Term. 52 Term. 53 Socket 2 Term. 70 Term. 71 Term. 72 Term. 73 Socket 3 Term. 74 Term. 75 Term. 76 Term. 77 Socket 4 Term. 78 Term. 79 Term. 80 Term. 81 Aquametro AG Time adjustments are possible with the keypads (see operating manual) or via the communication interface. If an M-Bus network with central access is present, all connected meters can be time adjusted by a single broadcast command. 7. Replacing and fixing cover • After all connections have been made, reinsert the ribbon cable with the power turned off and check that it is firmly connected. • While closing the cover, make sure that the rubber gasket is in the correct position • Tighten the cover screws uniformly and without too much torque (plastic threads) • Do not apply seals and security stickers until commissioning is completed ! Testing flow A ★ flashes on the meter display whenever there is flow. The flashing frequency is not related to the actual flow rate. The measured value of flow rate is given on the “Instantaneous values” display (Q xxxx.xxx m3/h). Testing the optional output circuits Each activation of a relay results in an increment of the corresponding event counter. By observing the index of the event counter the output function can be monitored. Check this with the ”Field configuration” - ” OUT x” - ”Function” menu. 8. Commissioning and operational checks Analogue outputs show their currents in mA. These can be checked with the ”Field configuration” - ”OUT x” - „Function” menu. The displayed value should correspond to the measured output current provided that the auxillary voltage is applied and the circuit resistance is correct. During commissioning, the functionality of the heat metering system is checked in order to guarantee the correctness of readings. Aquametro strongly recommends having the system commissioned by one of its experienced specialists. Finalizing and sealing After the final commissioning the two upper cover screws should by covered with the plastic studs provided. The lower two screws should be sealed with the included stickers. Setting date and time Without the real-time clock card (2RWC) installed, the internal clock stops whenever the power supply is shut off. If the billing dates and the data logger functions are to be used, the time and date must be actualized during commissioning via the serial interface. The presence of a real-time clock card is recognised when the displayed date and time correspond to actual values. The internal hours in service counter registers the total operating time. Aquametro AG 37 VD 3-168 DEF 9. Error messages Errors are indicated on the main display by an alternating flashing of *****Error *****. A detailed description of the cause of the error is given under the ”Error message” sub-menu. A remediable error (e.g. inversed temperature sensors or connection faults) may be eliminated on-site. Internal heat meter errors will generally require repair or replacement of the device. VD 3-168 DEF 38 Aquametro AG 3-168-e.eps Commissioning check-list 1. Match between flow transmitter and heat calculator: does the pulse value (or measuring range for analogue transmitters) of the flow transmitter match the pulse value of the heat calculator ? 2. Is the expected flow rate within the measuring range of the transmitter ? 3. Is the flow transmitter installed in the correct position ? 4. Does the direction of flow match the direction of the arrow ? 5. Have the pipes been flushed ? 6. Are all the connections tight ? 7. Has the flow transmitter been completely installed and filled with water ? 8. Do the temperature sensors belong to the same pair ? 9. Have the temperature sensors been cabled correctly ? Are any cable extensions wired according to the instructions ? 10. Is the display present ? 11. Are the temperatures plausible (Th higher than Tc) ? 12. Is the flow rate plausible ? 13. Meter readings Energy ______________ kWh MWh MJ GJ MI Volume ______________ m3 Operating hours ______________ 14. C o m m i s s i o n e d Date ______________ Time ______________ 15. Close and affix seals to the cover and the temperature sensor (if applicable). E r r o r me s s a g e HW Temp Alarm (Cold) HW Temp Alarm (Hot) T y pe o f f a ul t Po s s i b l e c a u s e A c t i o ns t o be t a ke n Hardware temperature alarm (cold side) Jumpers missing in case of two-wire connection Use 4 jumpers as shown in the wiring diagramme Temperature measurement is impossible Breakage and/or short circuit in the sensor wiring Disconnect sensor wires and check sensor wires and/or sensor(s) with Ohmmeter. If OK, check temperature input with resistor, for example: 100 Ohm. Hardware temperature alarm (hot side) see above see above Temperature measurement is impossible Delta-T Alarm Differential temperature SW Temp Alarm (Cold) Software temperature alarm (cold side) SW Temp Alarm (Hot) Software temperature alarm (hot side) Namur line break NAMUR monitoring Alarm 6 Reserve Alarm 6 Register over flow on relay pulse function or RTC data invalid. Problem with output option card(s) Differential temperature range exceeded. P e r m i s s i b l e r a n g e : dT -10...200°C Cold side temperature range exceeded. Permissible range for water Tc: 0...200°C, or according to specifications for other heat carriers. Hot side temperature range exceeded. Permissible range for water 0...200°C, or according to specifications for other heat carriers. NAMUR transmiter is faulty, or interrupted I<0.2 mA Transposed temperature sensors, or see above Check current temperature ("Instant Values" sub-menu), and compare with temperature range in "Factory Configuration" sub-menu. see above Check NAMUR transmitter or measure transmitter current Check voltage, 16...24VDC or 12...18VAC 50/60Hz Overvoltage alarm Alarm for overvoltage, TP10/2>35V Voltage on low voltage input is too high Check voltage, 16...24VDC or 12...18VAC 50/60Hz Serial EEPROM alarm! Overflow alarm EEPROM readout problems Power or flow is too high Equipment fault By more than 40 metering steps per measurement c y c l e i n t h e e n e r g y d i s p l a y , o r w h e n µP c a n n o longer keep up Equipment fault Send equipment in for repair Fault message only goes out at Q=0 or if voltage supply is interrupted. Send equipment in for repair RAM alarm! RAM read-out problems Equipment fault Send equipment in for repair EPROM/FLASH alarm! FlashEPROM readout problems Equipment fault Send equipment in for repair Analogic input MB receives no response from 2AIN option card T h e 2 A I N o p t i o n c a r d i s n o t p r e s e n t o r i s f a u l t y Option Alarm Backup alarm (from V104) Use CALTOOL or MBUSTOOL to increase pulse value. Check actual power or flow. Validate date and time. Option card(s) not present or transposed. Check using "Field Configuration" sub-menu. Use CALTOOL or MBUSTOOL Ito increase pulse value Check instant power or flow 3-168-e2.eps Undervoltage alarm Output pulse value too low. CALEC is operated at overload. RTC data invalid. Programming does not match option hardware, for example: energy pulse at 2AOU up to V103, from V104 Relay overflow Output pulse value too low. error message. Register overflow on relay Actual power or flow too high, overload operation. pulse function. Alarm for undervoltage, TP10/2<11.7V Voltage on low voltage input is too low Option overflow (from V104 on) Send the device in to be checked This alarm can be activated or suppressed with the production program. Aquametro AG 39 VD 3-168 DEF 10. Technical data Heat meter calculator Measurement operating temperature range Temperature difference range Type approved operating range Approved temperature difference range T 0°C ∆T 0 T 5°C ∆T 3 Temperatur sensor type, Connection style Sensor cable length Pt100 according to IEC 751, Two or four-wire type Tested to 15 m Energy display units Display capacity Maximum thermal power kWh - MWh | MJ - GJ 99’999’999 30’000 MW / GJ/h Volume display units Display capacity Measuring and calculation time interval Time between revisions m3 or Ml (Megaliter) 99’999’999 ~ 2 sec. 10 years Accuracy class Measuring and calculation error EN 1434-1 / OIML Cl. 4 ≤ 0.5% at ∆T ≥ 3K, typ. 0,3% Power supply and interfaces Mains supply Supply via AMBUS-network Communications interface on the calculator panel Communications interface at the M-Bus terminals 230 V (+10-15%) 50 Hz, 15 VA, fully isolated 16...24 V DC or 12...18 V AC 50/60Hz Optical interface acc. to EN1434-3 with M-Bus protocol M-Bus protocol according to EN 1434-3 (IEC 870-5), galvanic isolation Housing, environmental conditions Wall housing Protection class Ambient temperature range, Environmental class Storage temperature range for installation on DIN rail (35 mm) or tree-hole fixture IP 54 5 ... 55°C, EN 1434 Class “C“ -20 ... 65°C VD 3-168 DEF ... ... ... ... 200°C 200 K 180°C 175 K 40 Aquametro AG Flow rate input Flow pulse input for - Contact pulser - Open collector pulser - Namur pulser (DIN 19234) - Active pulsers via optocoupler input Duration Duration Duration Duration Programmable pulse values 0.001 ml ... 100 m3 with a resolution of 0.001 ml Analogue input for flow rate (option) 0...20 mA or 4...20 mA, linear signal progression Input resistor 120 Ω, no galvanic isolation 1 0 0 ' 0 0 0 m 3/ h Cold or hot side Maximum flow rate Flow transmitter mounting position of of of of pulse pulse pulse pulse ≥ ≥ ≥ ≥ 25 ms 2.5 ms 2.5 ms 50 µs, max. 10 kHz, 5...30 V, ≥ 5 mA 2. Flow rate or control input (optional) Control input ON OFF with active signal via the optocoupler input 5...30 V, ≥ 5 mA, with closed contact no active signal, with open contact Flow pulse input for - Contact pulser - Open collector pulser - Namur pulser (DIN 19234) - Active pulsers via optocoupler input max. 50 Hz, no debounce function max. 50 Hz, with 64:1 divider max. 200 Hz max. 50 Hz, with 64:1 divider max. 200 Hz Duration of pulse ≥ 50 µs, with 64:1 divider max. 1000 Hz, 5...30 V, ≥ 5 mA Programmable pulse values 0.001 ml ... 100 m3 with a resolution of 0.001 ml Analogue input for flow rate (option) 0...20 mA or 4...20 mA, linear signal progression Input resistor 120 Ω, no galvanic isolation Cold or hot side (with option Twin E only) Flow transmitter mounting position Output functions (optional) Relay output card 2RWC, 2RNC two solid state contacts, potential-free m a x . v a l u e s 5 0 V A C / D C , 1 0 0 m A , R ON ≤ 2 0 Ω , R OFF ≥ 1 M Ω Analogue output card 2AOU galvanically isolated, to be operated actively or passively, output current 0...4 mA or 4...20 mA Supply 5...24 VDC, RL max at 24 V = 950 Ω 300...9600 baud half duplex, max. cable length 15 m 300...9600 baud half duplex, max. cable length 1200 m Interface card RS232 Interface card RS485 Aquametro AG 41 VD 3-168 DEF 11. Validity of calibration 13. Guarantee and liability In most countries heat meters used for invoicing physical quantities are subject to compulsory recalibration. After the initial period of validity has expired, heat meters must be recalibrated regularly by an authorized authority, usually every five years. The heat meter operator is responsible for complying with this obligation. Aquametro guarantees this product within the framework of its general conditions of sale and delivery. Aquametro is quality certified to ISO 9001/EN29001 and its products comply with current standards and directives. Aquametro cannot be held liable for any consequences arising from incorrect installation and/or operation. It is therefore essential to: • follow the installation and operation instructions • use the unit for the designed purpose only • use only accessories that have been proved safe and reliable. • All liability for installation and handling of the unit is carried by the owner or operator. 12. Service life and maintenance The service life of the heat calculator until the first revision is 10 years. The year of manufacture is indicated by the serial number on the nameplate (e.g. S/N 3.xxx.xxx/96) and is also displayed under ”Works configuration”. The unit is maintenance-free. Clean with a damp cloth only. Never use solvents. VD 3-168 DEF 42 Aquametro AG Menu-Overview Standard (More menu-overviews: page 42...45) Sub-menu Mainmenu Display on pulse input IN1 EBS Display on current input (opt.) 1.000 L/Imp cold side or = IN1current 0...20 mA EBS cold side + EH 0002216.1608 kWh VH 00259.425303 m3 E V 00002216. kWh 000259.42 m3 Textfield Display on error only Error message Display on error only n o f a u l t HW temp. alarme(hot) Enter Exit Enter Exit Enter Exit Enter E 00002216. kWh E 00002216. kWh Exit Bill date 1 30.06.-- Bill date 2 30.12.-- Instantaneous values Enter P Q Display on error only Option Alarm Enter Exit Display on error only Overflow Alarm Enter Exit xxxxxxx Alarme Enter Billing date Enter 3.759526 MW Temp. ∆T 175.04 K k-Fact 1.1770 Wh/l/K Date 18.247 m3/h H 180.0 C 4.9 °C Density 1.00068 kg/l Time 11.05.98 10.25 10.25 Edit: Data Logger Enter Period monthly Integr.lap 15 min Date 00 xx.xx.xx Date Enter 01 4 Infofield Exit Enter 11.05.98 Up, Down xx.xx.xx Date Enter 02 4 Infofield Total working time xxxxxxxx h xx.xx.xx Date Enter 03 4 Infofield xx.xx.xx Date Enter 04 4 Infofield xx.xx.xx Date Enter 05 4 Infofield xx.xx.xx Date Enter 06 4 Infofield xx.xx.xx Date Enter 07 4 Infofield xx.xx.xx Date Enter 08 xx.xx.xx Date Enter xx 4 Infofield 4 Infofield inhibition of low ∆T 0.00 °C Exit xx.xx.xx Date Enter 14 4 Infofield on pulse input only Factory config. Enter Serial Nr. 03784829 Man. date 31.05.97 CALEC MB Ver. 200 Fluid number Heat calculator water 000 Temp.sensor Pt100 T 0...200 °C IN1 pulse Kl. 10/11 on current input only (opt.) xxxxxxx IN1 current 0...20mA Enter Kl. 10/11 Enter Enter Date xx.xx.xx V 000259.42 m3 on current input only (opt.) Flow sensor location inhibition of low cold side Q 0.000 m3/h xx.xx.xx Exit Enter Date xx.xx.xx E 00002216. kWh Enter pulse value 1.0000 l 20mA->30.000 m3/h max.frequency200 Hz linear Time 00:00 xx.xx.xx P 3.759526 MW Time 00:00 xx.xx.xx Q 18.247 m3/h Exit Enter Field configuration Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Function xxxxxx OUT3 Enter Kl. 70/71 Function xxxxxx OUT4 Enter Kl. 72/73 Function xxxxxx OUT5 Enter Kl. 74/75 Function xxxxxx OUT6 Enter Kl. 76/77 Function xxxxxx OUT7 Enter Kl. 78/79 Function Status check Enter on pulse input only on current input only (opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 03.56 mA Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# Keys up + down OK Exit Enter xxxxxx OUT8 Enter Kl. 80/81 Function xxxxxx OUT9 Time count OUT10 Time count M-Bus BAUD = 2400 Enter Kl. --/-Enter Kl. --/-Enter Kl. 24/25 Adr. 000 Function Function Function Language English Exit Aendern Enter Exit Exit English Enter Exit Français Enter Exit Italiano Enter Exit Enter standard-e.eps Optional fields Aquametro AG 43 Enter Deutsch Enter VD 3-168 DEF 14. Operating instructions Tip for fast return to main display: Press the or keys simultaneously. This combination is also used for switching to the high resolution display mode from the basic setting. The device is operated using three buttons (keypad) on the front panel. Moving up and down through the menu is achieved with the up and down arrow keys. The ”Enter” key is used to select a function in the menu. The word ”Enter” is nearly always displayed at the appropriate point. The enclosed table, showing an overview of the menu, will help you find the values of interest. Deviations due to options and special versions are shown as appropriate. Example Displaying the operating temperatures (starting from the main meter display showing energy and volume). 14.1 Repeatedly press the key down until ”Instantaneous values” is displayed. Press the return key to select the instantaneous values menu. Repeatedly press the key until the temperatures are displayed. The display returns automatically to the main meter display after a few minutes. Setting date and time Time corrections (e.g. after power failure or for summer/winter changeover) can be made once a month with the operating keys. Time settings are made exclusively in steps of one minute. The date cannot be changed from the keypad. Any further time and date alterations can only be made via the communications interface using the corresponding software, if this is not disabled by the heat supplier (Locklevel 2). If the search is to be continued, e.g. to display function and settings of the first option card, proceed as follows: Press the or keys until ”EXIT” and ”ENTER” are displayed. Press the key to return to the main menu Repeatedly press the key until ”Field configuration” is displayed Press the key to activate the field configuration menu Repeatedly press the key until the desired information is displayed Press the key to display further information in the sub-menu. VD 3-168 DEF Procedure for manually correcting the time Use the keypad to select the date and time display from the ”Instantaneous values” menu. Press the key at the date and time display. Then press the or key to advance or retard the time in steps of one minute. Press to confirm the setting. During the same day, time adjustments can be repeated any number of times, but after the date has changed no further time adjustment is possible (protection against unauthorized manipulation of meter reading dates). 44 Aquametro AG 14.2 14.4 Entering field programmable data Meter reading via an optical interface All field programmable settings, which allow the use of the various options, can be entered or changed via the M-Bus interface using the ”CALTOOL”-software. These functions have no effect on the metering, serving only as an additional convenience. 14.3 Setting billing dates, logger periods and integration times These settings can be changed at will via the M-Bus or optical interface using the ”CALTOOL” software. In contrast to the unprotected optional field parameters, these settings can be protected against further alterations with the ”lock-level” utility by setting it to two. No further changes can then be made without opening the unit and breaking the seal. Bild-14.eps Meter reading via an optical interface is accomplished by placing the reading head (e.g. Aquametro OCI 9600) on the appropriate point on the meter marked with IEC 870-5. The head is held in place magnetically. The hand-held reading unit must be able to execute a suitable program in compliance with the EN 1434-3 (M-Bus) specifications. For single unit readouts the ”CALTOOL”-software is adequate. Caution: Electricity meters with optical interfaces use the older ZVEI-protocol (IEC 1107)! Reading is initiated exclusively from the hand-held terminal or remote computer. Reading does not change or delete any data stored in the CALEC® MB. Communication parameters Communication parameters are set via the interface with ”CALTOOL”software. A baud rate of 2400 is the default for CALEC® MB. Reading units must be able to communicate at this speed, otherwise the CALEC®baud rate must first be reduced . Warning: In case of simultaneous access via M-Bus and the optical interface, data transfer conflicts may arise which can only be solved by an exclusive access by one of the two sources at any one time. Aquametro AG 45 VD 3-168 DEF 15. Declaration of conformity 14.5 Language selection The unit is delivered with four language options. Language selection can be made with the keypad. Procedure Use the keypad to select the language display from the ”Field configuration” menu. Select the desired language with the and keys. Confirm the selection with . This procedure can be repeated as many times as necessary. 14.6 Display test In this position two lines containing 20 fields of dots each must be visible. 14.7 M-Bus operation For M-Bus network operation the EN 1434-3 directives and the additional Aquametro recommendations given in the AMBUS®-technical information are applicable. VD 3-168 DEF 46 Aquametro AG 16. Annexe: Menu-overview software options Option DTF Mainmenu Sub-menu Display on pulse input Display on current input (opt.) IN1 EBS 1.000 L/Imp cold side or = IN1current 0...20 mA EBS cold side + EH 0002216.1608 kWh VH 00259.425303 m3 E V 00002216. kWh 000259.42 m3 Et 00002216. kWh Vt 000153.87 m3 EHt 002216.1608 kWh VHt 0153.873500 m3 Textfield Display on error only Error message Display on error only n o f a u l t HW temp. alarme(hot) Enter Exit Enter Exit Display on error only Option Alarm Enter Exit Display on error only Enter Exit Overflow Alarm Enter Exit xxxxxxx Alarme Enter Enter E 00000321. kWh Et 00000026. kWh E 00001216. kWh Et 000000104. kWh Exit Bill date 1 30.06.97 Bill date 1 30.06.97 Bill date 2 30.12.97 Bill date 2 30.12.97 Enter Instantaneous values Enter P Q Billing date 3.759526 MW Temp. ∆T 175.04 K k-Fact 1.1770 Wh/l/K Date 18.247 m3/h H 180.0 C 4.9 °C Density 1.00068 kg/l Time 11.05.98 10.25 10.25 Edit: Data Logger Enter Period monthly Integr.lap 15 min Date 00 xx.xx.xx Date Enter 01 4 Infofield Exit Enter 11.05.98 Up, Down xx.xx.xx Date Enter 02 4 Infofield Total working time xxxxxxxx h xx.xx.xx Date Enter 03 4 Infofield xx.xx.xx Date Enter 04 4 Infofield xx.xx.xx Date Enter 05 4 Infofield xx.xx.xx Date Enter 06 4 Infofield xx.xx.xx Date Enter 07 4 Infofield xx.xx.xx Date Enter 08 4 Infofield xx.xx.xx Date Enter xx 4 Infofield 4 Infofield inhibition of low ∆T 0.00 °C Exit xx.xx.xx Date Enter 14 on pulse input only Factory config. Enter Serial Nr. 03784829 Man. date 31.05.97 CALEC MB Ver. 200 Fluid number Tarif calculator water 000 Temp.sensor Pt100 T 0...200 °C IN1 pulse Kl. 10/11 on current input only (opt.) xxxxxxx IN1 current 0...20mA Enter Kl. 10/11 Enter pulse value 1.0000 l 20mA->30.000 m3/h max.frequency200 Hz linear xxxxxxx i n h i b i t i o n o f l o w Enter Q 0.000 m3/h Enter Date xx.xx.xx Et 0000942. kWh on current input only (opt.) F l o w s e n s o r l o c a t i o n IN2 pulse c o l d s i d e Kl. 56/57 xx.xx.xx Exit Enter Date xx.xx.xx E 00002216. kWh Time 00:00 xx.xx.xx 3.759526 MW Enter P Pulse value --/-Tarif switch Time 00:00 xx.xx.xx Q 5.942 m3/h Exit Enter Field configuration Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Function xxxxxx OUT3 Enter Kl. 70/71 Function xxxxxx OUT4 Enter Kl. 72/73 Function xxxxxx OUT5 Enter Kl. 74/75 Function xxxxxx OUT6 Enter Kl. 76/77 Function xxxxxx OUT7 Enter Kl. 78/79 Function Status check Enter on pulse input only on current input only (opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 03.56 mA Tarif2: on/off t = 00000358 s Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# Keys up + down OK Exit Enter xxxxxx OUT8 Enter Kl. 80/81 Function xxxxxx OUT9 Time count OUT10 Time count M-Bus BAUD = 2400 Enter Kl. --/-Enter Kl. --/-Enter Kl. 24/25 Adr. 000 Function Function Function Language English Exit Aendern Enter Exit Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Exit Enter Optional fields Aquametro AG 47 VD 3-168 DEF Enter Option ISPC Mainmenu Sub-menu Display on pulse input Display on current input (opt.) IN1 EBS 1.000 L/Imp cold side or = IN1current 0...20 mA EBS cold side + EH1 002216.1608 kWh VH1 0259.425303 m3 E1 00002216. kWh V1 000259.42 m3 VH2 0153.873500 m3 V2 000153.87 m3 Textfield Display on error only Error message Display on error only n o f a u l t HW temp. alarme(hot) Enter Exit Enter Exit Display on error only Option Alarm Enter Exit Display on error only Enter Exit Overflow Alarm Enter Exit xxxxxxx Alarme Enter Enter E1 00000321. kWh V2 00000026. m3 E1 00001216. kWh V2 000000104. kWh Exit Bill date 1 30.06.97 Bill date 1 30.06.97 Bill date 2 30.12.97 Bill date 2 30.12.97 Enter Instantaneous values Enter P Q Billing date 3.759526 MW 18.247 m3/h Q2 6.735 m3/h Temp. ∆T 175.04 K k-Fact 1.1770 Wh/l/K Date H 180.0 C 4.9 °C Density 1.00068 kg/l Time 11.05.98 10.25 10.25 Edit: Data Logger Enter Period monthly Integr.lap 15 min Date 00 xx.xx.xx Date Enter 01 4 Infofield xx.xx.xx Date Enter 02 4 Infofield Exit Enter 11.05.98 Up, Down xx.xx.xx Date Enter 03 4 Infofield Total working time xxxxxxxx h xx.xx.xx Date Enter 04 4 Infofield xx.xx.xx Date Enter 05 4 Infofield xx.xx.xx Date Enter 06 4 Infofield xx.xx.xx Date Enter 07 4 Infofield xx.xx.xx Date Enter 08 4 Infofield xx.xx.xx Date Enter xx 4 Infofield 4 Infofield inhibition of low ∆T 0.00 °C Exit xx.xx.xx Date Enter 14 on pulse input only Factory config. Enter Serial Nr. 03784829 Man. date 31.05.97 CALEC MB Ver. 200 Fluid number ISPC calculator water 000 Temp.sensor Pt100 T 0...200 °C IN1 pulse Kl. 10/11 on current input only (opt.) xxxxxxx IN1 current 0...20mA Enter Kl. 10/11 Enter pulse value 1.0000 l 20mA->30.000 m3/h max.frequency200 Hz linear xxxxxxx i n h i b i t i o n o f l o w Enter Q 0.000 m3/h Enter Date xx.xx.xx V1 000059.42 m3 on current input only (opt.) F l o w s e n s o r l o c a t i o n IN2 pulse c o l d s i d e Kl. 56/57 xx.xx.xx Exit Enter Date xx.xx.xx E1 00002216. kWh Time 00:00 xx.xx.xx 3.759526 MW Enter P pulse value 1.0000 l max.frequency 50 Hz Time 00:00 xx.xx.xx Q 18.247 m3/h Exit Enter Field configuration Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Function xxxxxx OUT3 Enter Kl. 70/71 Function xxxxxx OUT4 Enter Kl. 72/73 Function xxxxxx OUT5 Enter Kl. 74/75 Function xxxxxx OUT6 Enter Kl. 76/77 Function xxxxxx OUT7 Enter Kl. 78/79 Function Status check Enter on pulse input only on current input only (opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 03.56 mA IN 2 f = 0.00 Hz t = 00000358 s Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# Keys up + down OK Exit Enter xxxxxx OUT8 Enter Kl. 80/81 Function xxxxxx OUT9 Time count OUT10 Time count M-Bus BAUD = 2400 Enter Kl. --/-Enter Kl. --/-Enter Kl. 24/25 Adr. 000 Function Function Function Language English Exit Aendern Enter Exit Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Exit Enter Optional fields VD 3-168 DEF 48 Aquametro AG Enter Option Twin E and Twin V Mainmenu Sub-menu Display on pulse input IN1 EBS Display on current input (opt.) 1.000 L/Imp cold side or = IN1current 0...20 mA EBS cold side + EH1 02216.1608 kWh VH1 0259.425303 m3 E1 00002216. kWh V1 000259.42 m3 E2 00002216. kWh V2 000153.87 m3 EH2 02216.1608 kWh VH2 0153.873500 m3 Textfield Display on error only Error message Display on error only n o f a u l t HW temp. alarme(hot) Enter Exit Enter Exit Display on error only Option Alarm Enter Exit Display on error only Enter Exit Overflow Alarm Enter Exit xxxxxxx Alarme Enter Enter E 1 0 0 0 0 0 3 2 1 . k W h E2 00000026. kWh E 1 0 0 0 0 1 2 1 6 . k W h E2 00000104. kWh E x i t B i l l d a t e 1 3 0 . 0 6 . 9 7 Bill date 1 30.06.97 B i l l d a t e 2 3 1 . 1 2 . 9 7 Bill date 2 31.12.97 Enter Instantaneous values Enter P Q Billing date 3.759526 MW P2 18.247 m3/h Q2 0.975246 MW Temp. ∆T 175.04 K k-Fact 1.1770 Wh/l/K Date 4.682 m3/h H 180.0 C 4.9 °C Density 1.00068 kg/l Time 11.05.98 10.25 10.25 Edit: Data Logger Enter Period monthly Integr.lap 15 min Date 00 4 Infofield 4 Infofield xx.xx.xx Date Enter 01 xx.xx.xx Date Enter 02 4 Infofield xx.xx.xx Date Enter 03 4 Infofield Total working time xxxxxxxx h Exit Enter 11.05.98 Up, Down xx.xx.xx Date Enter 04 4 Infofield xx.xx.xx Date Enter 05 4 Infofield xx.xx.xx Date Enter 06 4 Infofield xx.xx.xx Date Enter 07 4 Infofield xx.xx.xx Date Enter 08 xx.xx.xx Date Enter xx xx.xx.xx Enter 4 Infofield 4 Infofelder 4 Infofelder on current input 2 only (opt.) on current input 2 only (opt.) on current input 2 only (opt.) 4 Infofelder 4 Infofield Date 14 4 Infofelder Date xx.xx.xx E1 00002216. kWh on pulse input only Factory config. Enter Serial Nr. 03784829 Man. date 31.05.97 CALEC MB Ver. 200 Fluid number Twin-E calculator water 000 Temp.sensor Pt100 T 0...200 °C or Twin V calculator IN1 pulse Kl. 10/11 on current input only (opt.) xxxxxxx IN1 current 0...20mA Enter Kl. 10/11 Enter Flow sensor location IN2 pulse cold side Kl. 56/57 pulse value 1.0000 l 20mA->30.000 m3/h max.frequency200 Hz linear xxxxxxx IN2 current 0...20mA inhibition of low Enter Kl. 56/57 Enter Q 1.000 m3/h xx.xx.xx Exit Enter Enter Date xx.xx.xx V 00000942. m3 inhibition of low inhibition of low Q2 0.000 m3/h ∆T 0.00 °C Exit Option Twin-V only Date xx.xx.xx Option Twin-E only E n t e r E2 00000942. kWh pulse value 1.000 l 20mA->24.000 m3/h max.frequency 50 Hz linear Time 00:00 xx.xx.xx P1 3.759526 MW Time 00:00 xx.xx.xx Option Twin-V Q 1.238545 m3/h only Time 00:00 xx.xx.xx Option Twin-E P2 1.238545 MW only Field configuration Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Function xxxxxx OUT3 Enter Kl. 70/71 Function xxxxxx OUT4 Enter Kl. 72/73 Function xxxxxx OUT5 Enter Kl. 74/75 Function xxxxxx OUT6 Enter Kl. 76/77 Function xxxxxx OUT7 Enter Kl. 78/79 Function xxxxxx OUT8 Enter Kl. 80/81 Function Status check Enter on pulse input only on current input only (opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 12.16 mA on current input 2 only (opt.) IN 2 f = 0.00 Hz t = 00000358 s IN2 I = 7.12 mA Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# xxxxxx OUT9 Time count OUT10 Time count M-Bus BAUD = 2400 Enter Kl. --/-Enter Kl. --/-Enter Kl. 24/25 Adr. 000 Function Keys up + down OK Exit Enter Function Function Language English Exit Aendern Enter Exit Exit Enter Enter Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Exit Enter Optional fields Display on option Twin E only Aquametro AG 49 VD 3-168 DEF Option BDE and BDV Mainmenu Sub-menu Display on pulse input Display on current input (opt.) IN1 EBS 1.000 L/Imp cold side or = IN1current 0...20 mA EBS cold side + EH+ 02216.1608 kWh VH+ 0259.425303 m3 E+ 00002216. kWh V+ 000259.42 m3 E- 00002216. kWh V- 000153.87 m3 EH- 02216.1608 kWh VH- 0153.873500 m3 Textfield Display on error only Error message Display on error only n o f a u l t HW temp. alarme(hot) Enter Exit Enter Exit Display on error only Option Alarm Enter Exit Display on error only Enter Exit Overflow Alarm Enter Exit xxxxxxx Alarme Enter Enter E+ 00000321. kWh E- 00000026. kWh E+ 00001216. kWh E- 00000104. kWh Exit Bill date 1 30.06.97 Bill date 1 30.06.97 Bill date 2 30.12.97 Bill date 2 30.12.97 Enter Instantaneous values Enter P Q Billing date 3.759526 MW Temp. ∆T 175.04 K k-Fact 1.1770 Wh/l/K Date 18.247 m3/h H 180.0 C 4.9 °C Density 1.00068 kg/l Time 11.05.98 10.25 10.25 Edit: Data Logger Enter Period monthly Integr.lap 15 min Date 00 xx.xx.xx Date Enter 01 4 Infofield Exit Enter 11.05.98 Up, Down xx.xx.xx Date Enter 02 4 Infofield Total working time xxxxxxxx h xx.xx.xx Date Enter 03 4 Infofield xx.xx.xx Date Enter 04 4 Infofield xx.xx.xx Date Enter 05 4 Infofield xx.xx.xx Date Enter 06 4 Infofield xx.xx.xx Date Enter 07 4 Infofield xx.xx.xx Date Enter 08 4 Infofield xx.xx.xx Date Enter xx 4 Infofield 4 Infofield inhibition of low ∆T 0.00 °C Exit xx.xx.xx Date Enter 14 on pulse input only Factory config. Enter Serial Nr. 03784829 Man. date 31.05.97 CALEC MB Ver. 200 Fluid number BDE calculator water or 000 Temp.sensor Pt100 T 0...200 °C BDV calculator IN1 pulse Kl. 10/11 on current input only (opt.) F l o w s e n s o r l o c a t i o n IN2 pulse c o l d s i d e Kl. 56/57 pulse value 1.0000 l 20mA->30.000 m3/h max.frequency200 Hz linear xxxxxxx i n h i b i t i o n o f l o w Enter Q 0.000 m3/h Enter Date xx.xx.xx E0000942. kWh on current input only (opt.) xxxxxxx IN1 current 0...20mA Enter Kl. 10/11 Enter xx.xx.xx Exit Enter Date xx.xx.xx E+ 00002216. kWh Time 00:00 xx.xx.xx 3.759526 MW Enter P Pulse value --/-Tarif switch Time 00:00 xx.xx.xx P1.238545 MW Exit Enter Field configuration Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Function xxxxxx OUT3 Enter Kl. 70/71 Function xxxxxx OUT4 Enter Kl. 72/73 Function xxxxxx OUT5 Enter Kl. 74/75 Function xxxxxx OUT6 Enter Kl. 76/77 Function xxxxxx OUT7 Enter Kl. 78/79 Function Function Status check Enter on pulse input only on current input only (opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 03.56 mA Flow : positiv t = 00000358 s Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# xxxxxx OUT8 Enter Kl. 80/81 Keys up + down OK Exit Enter xxxxxx OUT9 Time count OUT10 Time count M-Bus BAUD = 2400 Enter Kl. --/-Enter Kl. --/-Enter Kl. 24/25 Adr. 000 Function Function Function Language English Exit Aendern Enter Exit Enter Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Exit Enter Optional fields Display on option BDV only VD 3-168 DEF 50 Aquametro AG 1. Présentation du produit et emballage 1.1 Emplacement de montage Le calculateur CALEC® MB est l’une des composantes d’un système de mesure de chaleur; c’est lui qui se charge du calcul précis de la consommation d’énergie thermique. Aquametro a fabriqué et testé ce produit avec le plus grand soin. Il a été soumis à des contrôles rigoureux par divers organismes d’homologation et déclaré conforme aux prescriptions en vigueur. • bonne accessibilité pour montage, relevé et entretien • choisir un emplacement autant que possible protégé et sec • protéger le calculateur contre la chaleur et le rayonnement direct du soleil • ne pas dépasser les longueurs de câble disponibles/autorisées pour les thermosondes • respecter les distances par rapport aux sources de fortes interférences électriques Une installation dans les règles de l’art et un montage conforme aux prescriptions contribueront à faire en sorte que le compteur de chaleur puisse remplir sa fonction durablement et à l’entière satisfaction de nos clients. Les prescriptions et recommandations de la norme pour compteurs de chaleur, EN 1434-6, sont applicables pour l’installation du calculateur de chaleur, du débitmètre et des thermosondes. Connecter le débitmètre à l’entrée IN1 du calculateur. S’assurer que la valeur d’impulsion du débitmètre est identique à celle indiquée sur le calculateur. Monter et raccorder les thermosondes selon les directives du fabricant et celles inhérentes à l’homologation. La boîte d’emballage contient: 1 calculateur de chaleur CALEC® MB 1 rail de montage DIN 1 sachet d’accessoires comprenant: 4 ponts métalliques pour le raccordement des thermosondes à deux fils, divers obturateurs borgnes de différentes tailles, 4 capsules de plombage rouges, 2 autocollants de plombage, 1 feuillet spécifiant le contenu du sachet 1 exemplaire des instructions de montage/mode d’emploi + éventuellement un étrier de montage (à commander) Aquametro AG Attention Ne pas retirer ou détériorer les plombs ou autocollants de plombage posés en usine! L’étalonnage officiel et la garantie d’usine seront automatiquement annulés. 51 VD 3-168 DEF 1.2 1.3 Instructions de montage Maintien de la classe de protection Enlever le couvercle (face avant) du calculateur après avoir desserré les 4 vis de fixation. Il peut être entièrement détaché du boîtier en déconnectant le câble plat qui le relie à la platine, et mis de côté jusqu’à ce que les travaux de branchement soient terminés. La classe de protection IP 54 n’est assurée que si les trous de fixation ne sont pas perforés. L’exploitant doit assurer par un montage correct le respect du degré de protection exigé. Il en est de même pour les entrées de câbles: câbles parfaitement adaptés et joints en caoutchouc bien serrés sont indispensables. 1.4 Déconnecter le câble plat avec précaution, en tirant parallèlement sur les deux côtés de la fiche! Rebrancher le câble avant la mise sous tension du calculateur. Entrées de câbles 9 presse-étoupes sont à disposition pour effectuer une installation selon les règles de l’art: 1 3 5 7 1 x PG 11 pour le câble d’alimentation (câble Ø 5...10) pos. A A 6 B 2 1 x PG 13 pour un câble de commande (câble Ø 6...12 mm); peut servir à rallonger simultanément les câbles de l’émetteur d’impulsions et ceux des thermosondes; pos. B 7 x PG 7 pour entrées individuelles (câbles Ø 2…5 mm): thermosondes, émetteur d’impulsions, autres entrées ou sorties; pos. 1 - 7. Pour un serrage correct des passe-câbles filetés logés très près les uns des autres, une clé à douille de 15 mm avec fente longitudinale est indispensable (voir photo). Engager le boîtier sur le profilé en chapeau 35 mm (EN 50022) livré avec l’appareil ou le fixer au mur au moyen de 3 vis à bois à tête plate (5 x 30 pas de vis à tête conique) selon schéma en page 2, la vis supérieure servant à la suspension. Pour le montage en tableau, il faut un étrier-support et un cadre (schéma d’encombrement en bas de la page 2), livrés avec le kit de montage MPM, qui comprend également un joint en caoutchouc entourant le calculateur. Remplacement d’un ancien modèle MCL/MCP: montage mural: kit de montage CWM; montage en tableau: kit de montage CPM. VD 3-168 DEF 52 Aquametro AG Amener, si possible, la tension du secteur sur un fusible séparé ou brancher sur l’alimentation du circuit de chauffage. Le calculateur est entièrement isolé et ne nécessite pas de mise à la terre. Le branchement au secteur s’effectue aux bornes marquées L + N. Toutes les autres bornes sont réservées exclusivement à la basse tension (< 50 V) et aux signaux de mesure. Raccordement: faire passer le câble d’alimentation (Ø 5...10 mm) par le presse-étoupe PG 11 de gauche (SW 22) et bien serrer. Connecter les fils du secteur aux bornes N et L. Pour Alimentation des raisons pratiques, un raccordement basse tension en cascade de plusieurs alimentationsou secteur n’est pas possible. En l’absence de câble d’alimentation-secteur, e.x..4x0.8 230 V / 50 Hz 15VAC Meterfermer le passe-câble avec l’un des Raccordement AMBUS .Bus secteur obturateurs borgnes contenus dans le sachet d’accessoires. 2. Prescription de branchement Le calculateur peut aussi bien être alimenté en 230 V que par le réseau basse tension AMBUS® . L’un ou l’autre des modes d’alimentation sera choisi en fonction du concept de mesure prévu. Toutes les connexions sont à effectuer selon le schéma de branchement ci-inclus. Les bornes numérotées jusqu’à 50 correspondent à la norme ”compteurs de chaleur” EN 1434-2. Phase Seuls des professionnels dûment accrédités sont en droit d’effectuer des travaux sur le secteur 230 V, en observant les prescriptions locales. Lorsque la tension 230 V est appliquée à des bornes autres que L + N prévues à cet effet, le calculateur sera inutilisable et il y a danger de mort! 24 60 2.2 Branchement basse tension (15V) via la centrale d’alimentation AMBUS ® 2.1 Ce branchement sert à l’alimentation du calculateur (dans ce cas, sans rétro-éclairage du module d’affichage et sans la source de tension auxiliaire) lorsqu’il n’est pas raccordé au secteur. Si le calculateur est intégré dans un réseau avec centrale de télérelevé AMBUS®, l’alimentation est amenée en même temps que les deux fils du M-Bus, assurant ainsi une communication sûre. Le calculateur est relié par un câble quadripolaire rond (Ø 3...5 mm) à l’une des boîtes de dérivation du Bus. Le raccordement pour l’alimentation se fait aux bornes 60 et 61. En l’absence du câble M-Bus, fermer le passe-câble avec un obturateur. En Allemagne, seule l’alimentation en 230 V est autorisée pour le fonctionnement en conformité d’étalonnage. Branchement au secteur 230 V Il faut s’assurer que l’alimentation en courant ne puisse indûment être coupée. Prendre toutes mesures de protection nécessaires envers le calculateur afin d’assurer sa mise hors circuit en cas de défaut d’ordre électrique. Le fusible sera limité à 10 A max. Aquametro AG 61 25 N Neutre L 66117gf.eps Les entrées non utilisées sont à fermer avec les obturateurs borgnes contenus dans le sachet d’accessoires. 53 VD 3-168 DEF Connexion avec 2 sorties de relais et 1 entrée de collecteur d'impulsions (ISPC) 3. Schémas de connexion carte-option 1 neutre phase Schémas de connexion CALEC® MB tension auxiliaire 18 V DC / 100mA OUT 1 OUT 2 AM066103.4 OUT 3 OUT 4 7370 71 72 + + - Warmseite Hot side Côté chaud 1 5 6 2 Kaltseite Cold side Côté froid raccordement-secteur 230 V / 50 HZ AM066117ef1 neutre phase Emetteur d'imp. ou entrée tarif + Durchflussgeber oder Tarifeingang Flow sensor or tariff input + - Connexion de l'entrée de commande et tarifaire (DTF), commandée par un relais interne tension auxiliaire 18 V DC / 100mA L N carte-option 2 par Ex. DTF entrée 2 2RWC ou 2RNC ou 2AOU OUT 3 OUT 4 56 57- 73 70 71- 72 + + 50 51 52 53 + Impulsgeber Flow sensor Débitmètre 64 65+ carte-option 1 2RWC ou 2RNC OUT 1 OUT 2 - raccordement-secteur 230 V / 50 HZ AM066117ef2 + Nulleiter / Neutral / Neutre Phase / Line / Phase VD 3-168 DEF 3 7 8 4 Hilfsspannungsausgang Auxiliary voltage output Sortie de tension auxiliaire 18VDC 64 65 M-Bus M-Bus Kleinspannungsversorung Low voltage connection Alimentation basse tension L N OUT5 OUT6 Optionskarte 3 Option card 3 Carteoption 3 Optionskarte 2 Option card 2 Carteoption 2 OUT3 OUT4 OUT1 OUT2 Option IN2 Optionskarte 1 Option card 1 Carteoption 1 50 51 52 53 + - + 70 71 72 73 + - + 74 75 76 77 Durchfluss / Flow / Débit 50 51 52 53 par Ex. ISPC entrée 2 (IN 2) 56 57 Netzanschluss Mains supply Alimentation réseau 230V/50Hz Eingang 1 / Input 1/ Entrée 1 IN1 10 11 Source Sense Sense + Source + 56 57 OUT7 OUT8 Optionskarte 4 Option card 4 Carteoption 4 + - + 78 79 80 81 Anschlüsse Connections Connexions 64 65 L N Source Sense Sense + Source + 60 61 24 25 Wärmerechner Heat calculator CALEC MB Calculateur de chaleur carte-option 2 54 Aquametro AG Variantes de connexion des sorties analogiques Sorties analogiques passives (strap enfichable sur passif) 64 65 L N OUT 1 OUT 2 50 51 52 53 OUT 3 carte-option 1 (2AOU) OUT 4 73 70 71 72 + + - neutre tension auxiliaire 18 V DC / 100mA Attention: polarité inversée! carte-option 2 (2AOU) phase neutre phase carte-option 1 (2AOU) Sorties analogiques actives (strap enfichable sur actif) tension auxiliaire 18 V DC / 100mA 64 65 L N raccordement-secteur 230 V / 50 HZ OUT 1 - DC 5...24 V AM066117ef3 OUT 2 50 51 52 53 + - carte-option 2 (2AOU) + - + OUT 3 OUT 4 7370 71- 72 + + - + - + raccordement-secteur 230 V / 50 HZ Sorties analogiques actives (strap enfichable sur passif) neutre phase carte-option 1 (2AOU) L N tension auxiliaire 18 V DC / 100mA max. 64 65 OUT 1 OUT 2 50 51 52 53 AM066117ef5 Strap enfichable sur le groupe optionnel 2AOU: carte-option 2 (2AOU) OUT 3 OUT 4 7370 71- 72 + + 1 6 raccordement-secteur 230 V / 50 HZ Rv AM066117ef4 actif Résistance: R V max = (Us-5)/0.02A Us = 24V Aquametro AG passif Exemple: (24V-5V) / 0.02A = 950Ω 55 VD 3-168 DEF 4. Raccordement des thermosondes Raccordement direct (schéma a) uniquement sondes avec câbles d’origine non raccourcis! Modes de raccordement conseillés Sondes à câbles raccordées directement 57 11 56 4 10 8 3 2 7 Attention! Sondes à câbles en raccordement à 4 fils 57 6 1 11 56 5 4 10 8 3 2 7 1 Sondes à câbles avec rallongement à 2 fils Sondes à têtes de raccordement, branchement à 4 fils 6 57 5 11 56 4 8 3 7 10 2 6 57 5 1 Important: les câbles d’origine des thermosondes à câble ne doivent pas être raccourcis, puisque la résistance des fils se rajoute toujours à celle de la sonde de température! 11 56 4 10 8 3 2 7 6 1 Rallongement/raccordement à 4 fils (schémas b + c): bien fixer les câbles de rallongement; utiliser un câble quadripolaire (Ø 4 x 0,8) pour chacune des sondes; brancher selon schéma b ou c. 5 d) c) b) a) VD-30 66117bf.eps côté froid types de sondes: PLH85/100 PLH120/100 TPK1121..21..31 VD 3-168 DEF 56 côté chaud côté chaud côté froid PLC85/100/2 PLC120/100/2 PLC210/100/2 DS100 côté froid types de sondes: côté chaud côté chaud côté froid VD-30 Le branchement à 4 fils est particulièrement recommandé, notamment lorsque les câbles d’origine des thermosondes sont trop courts pour pouvoir être raccordés directement selon le schéma a. Le rallongement à 2 fils selon schéma d est à éviter autant que possible. Aquametro AG OPTION IN 2 Montage des thermosondes Conformément aux prescriptions de la norme EN-1434, les thermosondes sont à installer soit en contact direct avec le caloporteur par l’intermédiaire d’un robinet à boisseau sphérique, soit dans des doigts de gant montés dans la tuyauterie. Le montage est à effectuer avec le plus grand soin, puisque la précision de mesure en dépend pour une grande partie. 57 11 56 - 5. Raccordement du débitmètre 4 10 2 8 3 7 57 6 1 + Capteur de débit 11 10 56 5 - 4 2 8 3 7 + 2e entrée de débit ou entrée tarif 6 1 5 66117cf.eps Débit IN 1 L’entrée pour impulsions volumétriques (bornes 10 + 11) permet de raccorder quatre types d’entrées de débit: • Émetteurs mécaniques Reed ou relais • Émetteurs électroniques Namur selon DIN 19234 ou commutateurs à collecteur ouvert. Respecter absolument la polarité indiquée sur le schéma de raccordement! • Sorties de débit actives; l’émetteur d’impulsions devra fournir du courant pour activer le circuit d’entrée isolé galvaniquement. Contrairement aux thermosondes, le câblage des émetteurs d’impulsions ne demande pas de précautions particulières. Un câble de Ø 2 x 0,8 convient parfaitement. Si des émetteurs passifs sont utilisés, il est possible d’effectuer l’amenée conjointement avec les thermosondes par l’intermédiaire d’un câble de rallongement commun. Une deuxième entrée éventuelle sera raccordée aux bornes 56/57. Ses caractéristiques sont identiques à celle de l’entrée 1 décrite plus haut. Sa fonction dépend de l’option choisie (DTF, ISPC, etc). Important: Les débitmètres peuvent avoir les valeurs d’impulsion les plus diverses! Raccorder impérativement le débitmètre à un calculateur programmé pour la même valeur d’impulsion (litres/impulsion). Il est possible de modifier, même ultérieurement sur le site, l’entrée volumétrique de sorte à pouvoir passer d’un émetteur électronique passif à un émetteur actif; il suffit de changer le pontage situé directement au-dessus des bornes. Les positions de pontage adéquates sont reprises sur le schéma de raccordement collé dans le calculateur (ceci n’est nécessaire qu’en cas de modification du type d’émetteur par rapport à celui spécifié à la commande). La législation interdit une modification ultérieure de la valeur d’impulsion programmée dans tous les cas où le calculateur est utilisé à des fins de facturation. Il en est de même pour la désactivation du filtre antirebonds et pour tout changement relatif au lieu de montage (côté froid/ côté chaud) du débitmètre. Aquametro AG Filtre anti-rebonds Si le calculateur est destiné à être raccordé à un émetteur d’impulsions mécanique (I.), l’entrée est protégée d’origine par un filtre anti-rebonds. Celui-ci est programmé en usine et ne peut plus être désactivé. 57 VD 3-168 DEF Sortie analogique max.100mA/50V RL Le CALEC® MB est équipé d’origine de l’interface M-Bus selon EN 1434-3, avec lequel toutes les données de mesure peuvent être relevées et toutes les fonctions de sortie programmées. Le Bus est raccordé aux bornes 24/25 (pas de polarité à respecter). Les signaux de sortie des cartes-options en présence sont disponibles aux bornes 50…53 (emplacement des bornes 1), 70…73 (emplacement des bornes 2) 74…77 (emplacement des bornes 3) et 78...81 (emplacement des bornes 4). Options disponibles par carte: deux contacts, deux sorties de courant, un canal d’interface RS 232 ou RS 485. Le type de chacune des cartes en présence, leur fonction, leur programmation et les bornes auxquelles elles sont raccordées peuvent être consultés dans le menu d’utilisation sous ”configuration sur site” (ex. OUT 1 - relais - bornes 50/51 - impulsion énergie1 - valeur d’imp. 1 kWh). Si les numéros des bornes d’une sortie ne sont pas connus, c’est-à-dire si aucun schéma spécifique à l’installation n’a été établi, le calculateur fournira lui-même ce renseignement. OUT 1 à 8 50+52 70+72 74+76 78+80 0/4 .. 20 mA + AC ou DC 51+53 71+73 75+77 79+81 RV OUT 1 à 8 51+53 71+73 75+77 79+81 source DC - 66117df.eps Sortie à relais 6. Signaux de sortie 50+52 70+72 74+76 78+80 Séparation du potentiel Les sorties analogiques passives sont isolées par isolation galvanique les unes des autres. Les sorties analogiques actives sont reliées à la même masse. Elles sonst reliées par galvanisation à la tension de secours et aux cartes en option, mais sont isolées par isolation galvanique des autres composants électroniques. Charge En cas d'utilisation de la tension de secours interne, la résistance de tous les circuits analogiques ne peut excéder la valeur suivante: R V max = (Us-5)/0.02 A Important: ne jamais mettre en place ou remplacer une carte-option alors que le calculateur est sous tension! Risque de perte des données! Sinon, toutes les sorties analogiques doivent être alimentées par une source extérieure plus puissante. Sortie de relais Chaque carte en option 2RNC ou 2RWC comporte 2 relais à semiconducteur qui peuvent recevoir au maximum 100 mA en CA ou en CC à 50 V maximum. Sortie analogique La configuration individuelle de chaque boucle de courant peut être choisie en sortie analogique passive ou active. Les sorties actives sont alimentées par une alimentation séparée interne, courant maximum de 100 mA. VD 3-168 DEF 58 Aquametro AG RS232 Interface de communication L'interface est alimentée par l'alimentation auxiliaire et elle est ainsi séparée galvaniquement de l'appareil. Les signaux pour GND, TXD et RXD sont disponibles aux bornes de connexion. Un signal +10 V utilisable comme DTR et/ou RTS est appliqué à une quatrième borne. Le protocole utilisé est identique à celui du M-Bus selon EN1434-3:1997 et IEC 870-5. Un emplacement doit être disponible sur la carte de base pour l'enfichage du module en option qui supporte 300 à 9600 bauds. La communication s'effectue en half duplex, alors que l'émission et la réception sont assurées par des canaux séparés. RS232 TXD RXD GND +10V Emplacement des bornes 1 50 51 52 53 Emplacement des bornes 2 70 71 72 73 Emplacement des bornes 3 74 75 76 77 Emplacement des bornes 4 78 79 80 81 Aquametro AG RS485 Interface de communication L'interface est alimentée par l'alimentation auxiliaire et elle est ainsi séparée galvaniquement de l'appareil. Le protocole utilisé est identique à celui du M-Bus selon EN1434-3:1997 et IEC 870-5. Un emplacement doit être disponible sur la carte de base pour l'enfichage du module en option qui supporte 300 à 9600 bauds. La communication s'effectue en half duplex, alors que l'émission et la réception sont assurées par le même canal. 59 RS485 B+ B- Emplacement des bornes 1 50 51 52 53 Emplacement des bornes 2 70 71 72 73 Emplacement des bornes 3 74 75 76 77 Emplacement des bornes 4 78 79 80 81 VD 3-168 DEF jour de référence déterminé” sont appelées à être utilisées, il convient de programmer la date et l’heure exactes lors de la mise en service via l’interface. Doté d’une carte-option avec horloge temps réel, le calculateur affichera la date réelle. Un compteur interne d’heures de service enregistre la durée totale de fonctionnement de l’appareil. Des remises à l’heure peuvent être effectuées soit par l’intermédiaire des touches (voir mode d’emploi), soit par l’interface de communication. Dans un réseau avec centrales AMBUS FA/ZS, tous les appareils raccordés peuvent être remis à l’heure en même temps. 7. Remise en place du couvercle et fermeture Une fois tous les branchements effectués et le calculateur n’étant pas sous tension, reconnecter le câble plat avec précaution et s’assurer qu’il soit bien en place. Lors de la fermeture du couvercle, vérifier que le joint ne soit pas déplacé. Resserrer les vis du couvercle uniformément et avec mesure (taraudage sur matière synthétique). N’apposer ou coller les dispositifs de plombage qu’une fois l’installation définitivement mise en service! Contrôle du débit L’appareil affiche un ★ clignotant s’il reçoit des impulsions de débit. La fréquence du clignotement n’est pas en rapport avec celle des impulsions. Le débit lui-même sera affiché sous ”valeurs instantanées”(Q xxxxx m3/h). Contrôle des cartes-options: Sorties à relais Chaque commutation est enregistrée par un compteur d’évènements. Sur la base de l’index de celui-ci, il est possible contrôler le bon fonctionnement des sorties. Voir sous ”configuration sur site” - ”sortie N°…” - ”fonction”. 8. Mise en service, contrôle du bon fonctionnement Sorties analogiques Le niveau de courant momentané est affiché en mA. Voir sous ”configuration sur site” - ”sortie N°…” - ”fonction”. Le courant affiché est une valeur de consigne et devrait être identique au courant effectif fourni par la carte-option, pour autant que la tension auxiliaire appliquée et la charge ohmique du circuit soient correctes. La mise en service d’une installation de mesure d’énergie thermique sert avant tout à contrôler sa fonctionnalité, afin de pouvoir garantir l’exactitude des données affichées par le calculateur. C’est la raison pour laquelle Aquametro conseille vivement de faire effectuer la mise en service par l’un de ses spécialistes. Programmation de la date et de l’heure Si le calculateur n’est pas équipé d’une carte-option avec horloge temps réel (2RWC), l’horloge interne de l’appareil s’arrête dès qu’il n’est plus sous tension. Dans les cas où les fonctions ”historique” et ”relevé à un VD 3-168 DEF 60 Aquametro AG 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Compatibilité entre le capteur de débit et le calculateur: Est-ce que la valeur d'impulsion du capteur correspond à celui du calculateur (respectivement la plage de mesure pour les débitmètres à signaux analogiques) ? Est-ce que le débit prévisible correspond à la plage de mesure du compteur ? Est-ce que la position du compteur est correcte ? Est-ce que le sens d'écoulement correspond au sens de la flèche ? Est-ce que les conduites ont été purgées ? Est-ce que tous les raccords sont étanches ? Est-ce que le capteur est correctement monté et rempli d'eau ? Est-ce que les sondes de température font partie de la même paire ? Est-ce que les sondes de température sont correctement raccordés ? Est-ce que les rallonges éventuelles des conducteurs sont câblées selon les instructions ? Est-ce que l'affichage est visible ? Est-ce que les températures sont plausibles (Th plus grand que Tc) ? Est-ce que le débit est plausible Index du compteur énergie ______________ kWh MWh MJ GJ MI volume ______________ m3 heures de service ______________ Mise en service date ______________ heure ______________ Fermer et plomber le couvercle et, si nécessaire, les sondes de température. Fin de la mise en service et plombage Lorsque la mise en service est définitivement terminée, condamner l’accès aux deux vis supérieures du couvercle à l’aide des capsules de plombage contenues dans le sachet d’accessoires. Les deux vis inférieures sont à protéger par les autocollants de plombage. Aquametro AG 9. Messages d’erreur Lorsqu’une erreur est détectée, les deux lignes affichent en alternance le message ****Erreur****. L’origine de l’erreur est indiquée en clair dans le sous-menu ”messages d’erreur”. Certaines peuvent être corrigées sur place, par ex. thermosondes inversées ou raccordements erronés. Si c’est le calculateur lui-même qui est en panne, il doit en général être remplacé. 61 VD 3-168 DEF 3-168-f.eps Check-list de mise en service A n n o n c e d 'e r r e u r HW Temp Alarm (Cold) G e n r e d 'e r r e u r Alarme de température HW côté froid Mesure de la température impossible HW Temp Alarm (Hot) Alarme de température HW côté chaud Mesure de la température impossible Delta-T Alarm Différence de température SW Temp Alarm (Cold) Alarme de température SW côté froid SW Temp Alarm (Hot) Alarme de température SW côté chaud Namur hors service Surveillance NAMUR Alarm 6 Réserve alarme 6 Dépassement de capacité de la fonction sortie à impulsions ou RTC data invalides. Problèmes de carte(s) de sortie option Option overflow (ab V104) Option Alarm Undervoltage alarm C a us e po s s i bl e Pont manquants Rupture ou court-circuit des sondes de température M e s ure s à pre ndre Mettre en place les 4 ponts selon le schéma de raccordement Déconnecter les liaisons et vérifier les sondes, respectivement les liaisons à l'aide d'un Ohm-mètre. Si elles sont en ordre, vérifier l'entrée à l'aide d'une résistance de 100 Ohm par ex. Voir le point précédent Voir le point précédent Dépassement de la plage de différence de t e m p é r a t u r e : p l a g e a d m i s s i b l e d T - 1 0 . . . 2 0 0°C Dépassement du domaine température côté froid. Plage admissible avec de l'eau Tc 0 ... 200°C. Pour d'autres fluides caloporteurs selon indications. Dépassement du domaine température côté chaud. Plage admissible avec de l'eau Tc 0 ... 200°C. Pour d'autres fluides caloporteurs selon indications. Emetteur NAMUR défectueux ou interruption I<0.2mA Raccordement des sondes de température croisés ou voir le point précédent Vérifier la température actuelle à l'aide du sous-menu "Valeurs momentanées" et comparer avec la plage de mesure dans le sous-menu "Configuration de l'installation". Valeur d'impulsion de sortie trop petite. Le CALEC se trouve dans une situation de surcharge. RTC data invalides La programmation ne correspond pas à la carte utilisée, par exemple impulsions d'énergie avec 2AOU. jusqu'à V103, à partir de V104 annonce Valeur d'impulsion de sortie trop petite. d'erreur dépassement relais. Dépassement Valeur momentanée de la puissance, respectivede capacité de la fonction relais à imp. ment débit trop grand, fonctionnement en surcharge Alarme en cas de sous-tension TP10/2<11.7V T e n s i o n d ’ a l i m e n t a t i o n t r o p p e t i t e Voir le point précédent Vérifier l'émetteur NAMUR ou mesurer le courant du senseur Augmenter la valeur d'imp. à l'aide de CALTOOL ou MBUSTOOL. Vérifier la valeur momentanée de la puissance ou du débit. Controller date et heure. Carte(s) d'option non présente ou croisée. Contrôler à l'aide du sous-menu "Configuration de l'installation". Augmenter la valeur d'impulsions à l'aide de CALTOOL ou MBUSTOOL. Vérifier la valeur momentanée de la puissance ou du débit. Vérifier la tension 16...24 VDC ou 12...18 VAC 50/60 Hz Alarme en cas de surtension TP10/2>35V Tension à l'entrée basse tension trop grande Vérifier la tension 16...24 VDC ou 12...18 VAC 50/60 Hz Serial EEPROM alarm! Overflow alarm P r o b l è m e d e l e c t u r e d e l ' EEPROM Trop grande puissance ou trop grand débit Erreur d'appareil En cas de plus de 40 pas de comptage dans l'affichage d'énergie lors d'un cycle de mesure ou s i l e µ- p r o c e s s e u r n ' a r r i v e p l u s à s u i v r e Erreur d'appareil Envoyer l'appareil pour réparation L'erreur ne disparaît que si Q=0 ou si l'alimentation est interrompue Envoyer l'appareil pour réparation Problème de lecture de la mémoire RAM Erreur d'appareil Envoyer l'appareil pour réparation Backup alarm (ab V104) RAM alarm! EPROM/FLASH alarm! Problème de lecture de la mémoire EPROM/Flash E r r e u r d ' a p p a r e i l Envoyer l'appareil pour réparation Analogic input Pas de communication avec la carte-option 2AIN C a r t e - o p t i o n 2 A I N n o n d i s p o n i b l e o u d é f e c t u e u s e Renvoyer le calculateur pour réparation 3-168-f2 Overvoltage alarm Cette alarme peut être activée, respectivement inhibée par le programme de production. VD 3-168 DEF 62 Aquametro AG 10. Caractéristiques techniques Calculateur d'énergie thermique Plage de température de service Différence de température Plage de mesure homologuée Différence de température homologuée T 0°C ∆T 0 T 5°C ∆T 3 Type de sonde de température, type de connexion Longueur de câble Pt100 selon IEC 751, raccordement à 2 ou 4 fils, testé jusqu'à 15 m Unité d'affichage de l'énergie Capacité d'affichage Puissance thermique max. kWh - MWh | MJ - GJ 99’999’999 30’000 MW / GJ/h Unité d'affichage du volume Capacité d'affichage Intervalle de mesure et d'intégration Durée de service entre les révisions m3 ou Ml (Megaliter) 99’999’999 ~ 2 sec. 10 ans Classe de précision Erreur de mesure et d'intégration EN 1434-1 / OIML Cl. 4 ≤ 0.5% à ∆T ≥ 3K, typ. 0,3% Alimentation et interfaces Alimentation secteur Alimentation par le réseau AMBUS Interface de communication sur le couvercle du boîtier Interface de communi. aux bornes de raccordement M-Bus 230 V (+10-15%) 50 Hz, 15 VA, à double isolation 16...24 V DC ou 12...18 V AC 50/60Hz Interface optique avec protocole M-Bus selon EN 1434-3 avec protocole M-Bus selon EN 1434-3 (IEC 870-5), avec séparation galvanique Boîtier, environnement Boîtier pour montage mural Classe de protection Plage de temp. ambiante, classe d'environnement Température de stockage sur rail DIN (35 mm) ou par l'intermédiaire de 3 vis IP 54 5 ... 55°C, EN 1434 Class “C“ -20 ... 65°C Aquametro AG ... ... ... ... 200°C 200 K 180°C 175 K 63 VD 3-168 DEF Entrée "débit" Entrée d'impulsions volumétriques pour - émetteurs mécaniques à contact "sec" - émetteurs à collecteur ouvert - émetteurs selon Namur (DIN 19234) - émetteurs actifs raccordés sur l'entrée à optocoupleur durée durée durée durée Valeurs d'impulsion programmables 0.001 ml ... 100 m3 avec une résolution de 0.001 ml Entrée de débit analogique (option) 0...20 mA ou 4...20 mA, caractéristique de la courbe: linéaire résistance à l'entrée 120 Ω, sans séparation galvanique 1 0 0 ' 0 0 0 m 3/ h côté froid ou chaud Débit maximum Lieu de montage du débitmètre d'impulsion d'impulsion d'impulsion d'impulsion ≥ ≥ ≥ ≥ 25 ms 2.5 ms 2.5 ms 50 µs, max. 10 kHz, 5...30 V, ≥ 5 mA 2e entrée de débit ou entrée-commande (option) Entrée-commande (DTF, BDV) ON OFF alimentée par signal actif via optocoupleur 5...30 V, ≥ 5 mA, ou contact fermé pas de signal actif ou contact ouvert Entrée d'impulsions volumétriques pour - émetteurs mécaniques à contact "sec" - émetteurs à collecteur ouvert - émetteurs selon Namur (DIN 19234) - émetteurs actifs raccordés sur l'entrée à optocoupleur max. 50 Hz; sans filtre anti-rebonds max. 50 Hz; avec diviseur 64:1 max. 200 Hz max. 50 Hz; avec diviseur 64:1 max. 200 Hz durée d'impulsion ≥ 50 µs, avec diviseur 64:1 max. 1000 Hz, 5...30 V, ≥ 5 mA Valeurs d'impulsion programmables 0.001 ml ... 100 m3 avec une résolution de 0.001 ml Entrée de débit analogique option) 0...20 mA ou 4...20 mA, caractéristique de la courbe: linéaire résistance à l'entrée 120 Ω, sans séparation galvanique côté froid ou chaud (avec option Twin E) Lieu de montage du débitmètre Fonctions de sortie (cartes-options) Relais 2RWC, 2RNC deux contacts à semi-conducteurs, libres de potentiel m a x . 5 0 V A C / D C , 1 0 0 m A , R ON ≤ 2 0 Ω , R OFF ≥ 1 M Ω Courant analogique 2AOU avec séparation galvanique, sortie active ou passive, courant de 0...4 mA ou 4...20 mA allimentation 5...24 VDC (sortie passive), RL max à 24 V = 950 Ω 300...9600 Baud en half duplex, longueur de câble max. 15 m 300...9600 Baud en half duplex, longueur de câble max. 1200 m (2 fils) Carte-interface RS232 Carte-interface RS485 VD 3-168 DEF 64 Aquametro AG 11. Obligation d’étalonnage officiel 13. Garantie et responsabilité Les compteurs de chaleur utilisés pour la facturation directe d’une quantité physique sont soumis dans la plupart des pays à l’obligation d’étalonnage, c’est-à-dire à un contrôle officiel par homologation. Après leur vérification primitive, les compteurs de chaleur doivent être réétalonnés par une autorité compétente avant expiration de la période de validité. Le respect des délais de réétalonnage incombe à l’exploitant du compteur de chaleur. La durée de validité d’un étalonnage officiel est fixée par la législation nationale; en règle générale elle est de 5 ans. Aquametro se porte garante de la qualité de ce produit dans le cadre de ses conditions générales de vente et de livraison. Aquametro est certifiée ISO 9001/EN 29001; ses produits sont fabriqués en conformité avec les normes actuelles et les directives en sa possession. Aquametro décline toute responsabilité en cas de montage et d’exploitation incorrects. Il convient donc de: • se conformer aux prescriptions de montage et d’utilisation • n’affecter l’appareil qu’à l’usage auquel il est destiné • n’utiliser que des accessoires pour lesquels il n’y aucune contreindication du point de vue sécurité d’emploi La responsabilité pour l’installation et le maniement de l’appareil de mesure passe au propriétaire ou à l’exploitant. 12. Durée d’utilisation et entretien Le CALEC® MB peut rester en service pendant 10 ans avant la première révision. L’année de fabrication est mentionnée sur la plaque signalétique, juste après le numéro de série (S/N 3.xxx.xxx/96); elle peut également être mise à l’affichage sous ”configuration en usine”. Le calculateur ne requiert pas d’entretien particulier. Pour son nettoyage, utiliser uniquement un chiffon humide, en aucun cas un solvant! Aquametro AG 65 VD 3-168 DEF Aperçu du menu Standard (Autres menus: page 64...67) Menu principal Sous menu Affichage visible en option "entrée d'impulsions" IN1 EBS 1.000 L/Imp côté froid Affichage visible en option "entrée de courant" (opt.) ou = IN1courant 0...20 mA EBS côté froid + EH 0002216.1608 kWh VH 00259.425303 m3 E V 00002216. kWh 000259.42 m3 Champ de texte Affichage visible seulement en cas de message d'erreur Message d'erreur Enter Affichage visible seulement en cas de message d'erreur pas d'erreur HW alarme de temp(hot) Enter Exit Enter Exit Exit Enter E 00002216. kWh E 00002216. kWh Exit Date réf. 1 30.06.-- Date réf. 2 30.12.-- Valeurs momentanées Enter P Q Affichage visible seulement en cas de message d'erreur Option Alarm Enter Exit Affichage visible seulement en cas de message d'erreur Overflow Alarm Enter Exit xxxxxxx Alarme Enter Jour de relevé Enter 3.759526 MW Temp. ∆T 175.04 K Fact-k 1.1770 Wh/l/K Date 18.247 m3/h H 180.0 C 4.9 °C Densité 1.00068 kg/l Heure 11.05.98 10.25 10.25 Edit: 11.05.98 Up, Down Enregistr. données Enter Période mensuelle Durée intégr.15 min Date 00 xx.xx.xx Date Enter 01 4 champs infos xx.xx.xx Date Enter 02 4 champs infos Duré de service xxxxxxxx h xx.xx.xx Date Enter 03 4 champs infos Exit Enter xx.xx.xx Date Enter 04 xx.xx.xx Date Enter 05 4 champs infos 4 champs infos seulement en option "entrée d'impulsions" seulement en option "entrée de courant" (opt.) xx.xx.xx Date Enter 06 4 champs infos xx.xx.xx Date Enter 07 4 champs infos xx.xx.xx Date Enter 08 4 champs infos xx.xx.xx Date Enter xx 4 champs infos xx.xx.xx Date Enter 14 4 champs infos Configuration en usine Enter N° de fabr. 03784829 Date fabr. 31.05.97 CALEC MB Ver. 200 N° de fluide Compteur de chaleur eau 000 Enter Date xx.xx.xx V 000259.42 m3 seulement en option "entrée de courant" (opt.) Sonde de temp. Pt100 I N 1 i m p u l s i o n x x x x x x I N 1 c o u r a n t 0 . . . 2 0 m A P l a c e m e n t d é b i t m è t r e S e u i l d ' i n h i b i t i o n T 0...200 °C Kl. 10/11 Enter Kl. 10/11 Enter côté froid Q 0.000 m3/h xx.xx.xx Exit Enter Date xx.xx.xx E 00002216. kWh Seuil d'inhibition ∆T 0.00 °C Exit Enter valeur d'imp. 1.0000 l 20mA->30.000 m3/h fréquence max. 200 Hz linéaire Heure 00:00 xx.xx.xx P 3.759526 MW Heure 00:00 xx.xx.xx Q 18.247 m3/h Exit Enter Configuration client Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Fonction xxxxxx OUT3 Enter Kl. 70/71 Fonction xxxxxx OUT4 Enter Kl. 72/73 Fonction xxxxxx OUT5 Enter Kl. 74/75 Fonction xxxxxx OUT6 Enter Kl. 76/77 Fonction xxxxxx OUT7 Enter Kl. 78/79 Fonction Service Enter seulement en option "entrée d'impulsions" seulement en option "entrée de courant" (opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 03.56 mA Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# Touches up+down OK Exit Enter xxxxxx OUT8 Enter Kl. 80/81 Fonction xxxxxx OUT9 cptr. durée OUT10 Enter Kl. --/-Enter Kl. --/-- Fonction Fonction cptr. durée M-Bus BAUD = 2400 Enter Kl. 24/25 Adr. 000 Fonction Langue Français Exit Aendern Enter Exit Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Enter Exit Enter standard-f.eps champs facultatifs, visibles seulement en option VD 3-168 DEF 66 Aquametro AG 14. Mode d’emploi Appuyer sur jusqu’à ce que l’information désirée apparaisse. Appuyer sur pour mettre d’autres informations du sous-menu à l’affichage. L'appareil se manipule à l'aide des trois touches sur la plaque frontale. Les deux touches (vers le haut) et (vers le bas) permettent d’avancer dans le menu ou de revenir en arrière. La touche ”enter” sert à entrer dans la fonction désirée à partir du menu principal ou d’une position dans le sous-menu. Cette possibilité est pratiquement toujours signalée à l’affichage par le texte ”ENTER”. Truc: retour rapide à l’affichage de base: Appuyer en même temps sur les touches et . Cette combinaison de touches permet également de passer de l’affichage de base à l’affichage à haute résolution. L’aperçu en page 14 reprend les informations pouvant être mises à l’affichage et leur localisation dans les menus et sous-menus. Les options ou exécutions spéciales spécifiques au calculateur apparaissent également à l’affichage. Exemple: Je veux visualiser les températures de service et l’affichage est en position standard (quantités d’énergie et de volume totalisées). Appuyer plusieurs fois sur la touche jusqu’à ce que ”valeurs instantanées” apparaisse. Appuyer sur la touche pour entrer dans le menu ”valeurs instantanées”. Appuyer plusieurs fois sur la touche jusqu’à ce que les températures soient affichées. L’objectif est ainsi atteint. L’affichage revient automatiquement en position standard au bout d’un certain temps. 14.1 Réglage de la date et de l’heure Une fois par mois, l’heure peut être corrigée par l’intermédiaire des touches (par ex. remise à l’heure après interruption de courant ou passage de l’heure d’été à l’heure d’hiver et vice-versa). Seul le champ des minutes peut être modifié. Cette opération ne permet aucune influence sur la date. Une programmation libre de l’heure et de la date n’est possible qu’au moyen d’un logiciel adéquat raccordé via l’interface de communication, pour autant que l’exploitant de chauffage n’aie pas verrouillé l’accès à cette fonction. Si vous voulez visualiser d’autres données, par exemple fonction et programmation de la carte-option N° 1, continuer comme suit: Appuyer sur ou jusqu’à ce que ”EXIT” et ”ENTER” apparaisse à l’affichage. Appuyer sur pour revenir au menu principal. Appuyer plusieurs fois sur jusqu’à ce que ”configuration en usine” apparaisse. Appuyer sur pour entrer dans le menu ”configuration en usine”. Aquametro AG Procédure de correction manuelle de l’heure A l’aide des touches, mettre à l’affichage ”valeurs instantanées”, puis ”date, heure”. Lorsque l’heure apparaît, appuyer sur ; à présent, une 67 VD 3-168 DEF correction minute par minute est possible à l’aide des touches et . Mise en mémoire à l’aide de . Cette opération peut être renouvelée à volonté durant le même jour. Dès qu’un changement de date aura eu lieu, aucune modification manuelle de l’heure ne sera plus possible au cours du même mois (protection contre d’éventuelles manipulations des jours de référence ou des données de tarification). 14.4 Relevé du calculateur via l’interface de lecture optique Le relevé par l’intermédiaire de l’interface optique intégrée s’effectue en appliquant une tête de lecture à infrarouge (par ex. type OCI 9600 d’Aquametro) sur l’emplacement marqué IEC 870-5 sur la plaque frontale. La tête de lecture est maintenue en place par l’intermédiaire d’un aimant. L’appareil de relevé doit être équipé du logiciel adéquat selon EN 1434-3 (M-Bus). Pour un relevé individuel, nous recommandons le logiciel ”CALTOOL” déjà mentionné plus haut. Attention: l’interface optique correspond au standard ZVEI (IEC 1107), mais transmet exclusivement le protocole M-Bus. Le relevé est initialisé à l’aide d’un lecteur portable ou d’un ordinateur. L’opération de relevé n’a aucune influence sur les données mémorisées par le calculateur. 14.2 Programmation des données de configuration sur site Les programmations possibles sur site, entre autres celles relatives aux options, peuvent être effectuées ou modifiées à l’aide du logiciel ”CALTOOL” d’Aquametro par l’intermédiaire de l’interface de communication. Une influence, quelle qu’elle soit, sur la mesure d’énergie thermique elle-même, est exclue. 14.3 Programmation des jours de relevé, de la période de saisie Datalogger et des intervalles d’intégration Paramètres de communication Les paramètres de communication sont établis par le logiciel ”CALTOOL”. La vitesse de transmission standard du CALEC® MB est de 2400 Baud. Les appareils de relevé seront de préférence en mesure de communiquer à cette vitesse. Dans le cas contraire, adapter auparavant le Baudrate du CALEC®. Attention: un relevé simultané par l’intermédiaire de l’interface de lecture optique et par un réseau M-Bus peut causer des problèmes de synchronisation, qui ne peuvent être résolus que par des accès décalés dans le temps. Normalement, ces données peuvent être changées à volonté à l’aide du logiciel ”CALTOOL”. Cependant, contrairement aux options -accessibles librement- elles peuvent être protégées contre toute modification ultérieure, toujours à l’aide du logiciel ”CALTOOL” (activation du niveau de protection 2). Dès lors, toute re-modification de ces données nécessite l’ouverture du calculateur, entraînant la détérioration du plombage d’usine. VD 3-168 DEF 68 Aquametro AG 15. Déclaration de conformité 14.5 Modification de langue Le calculateur est fourni avec possibilité d’affichage en quatre langues. La sélection de la langue à utiliser se fait à l’aide des touches de la plaque frontale. Procédure A l’aide des touches, mettre à l’affichage ”configuration sur site”, jusqu’à ”langue”. Sélectionner la langue à l’aide des touches et et confirmer par . Cette opération peut être renouvelée à volonté. 14.6 Display Test (test d’affichage) Lorsque cette fonction est à l’affichage, deux lignes à 20 champs de caractères chacune doivent apparaître, tous les points visibles. 14.7 Mode M-Bus Pour la mise en réseau M-Bus, respecter les directives de la norme M-Bus EN 1434-3, ainsi que les prescriptions complémentaires d’Aquametro, reprises dans l’Information Technique AMBUS®. Aquametro AG 69 VD 3-168 DEF 16. Annexe: aperçu des menus, options "software" Option DTF Menu principal Sous menu Affichage visible en option "entrée d'impulsions" IN1 EBS 1.000 L/Imp côté froid Affichage visible en option "entrée de courant" ou = IN1courant 0...20 mA EBS côté froid + EH 0002216.1608 kWh VH 00259.425303 m3 E V 00002216. kWh 000259.42 m3 Et 00002216. kWh Vt 000153.87 m3 EHt 002216.1608 kWh VHt 0153.873500 m3 Champ de texte Affichage visible seulement en cas de message d'erreur Message d'erreur Enter Affichage visible seulement en cas de message d'erreur pas d'erreur HW alarme de temp(hot) Enter Exit Enter Exit Affichage visible seulement en cas de message d'erreur Option Alarm Enter Exit Affichage visible seulement en cas de message d'erreur Exit Overflow Alarm Enter Exit xxxxxxx Alarme Enter Enter E 00000321. kWh Et 00000026. kWh E 00001216. kWh Et 000000104. kWh Exit Date réf. 1 30.06.97 Date réf. 1 30.06.97 Date réf. 2 30.12.97 Date réf. 2 30.12.97 Enter Valeurs momentanées Enter P Q Jour de relevé 3.759526 MW Temp. ∆T 175.04 K Fact-k 1.1770 Wh/l/K Date 18.247 m3/h H 180.0 C 4.9 °C Densité 1.00068 kg/l Heure 11.05.98 10.25 10.25 Edit: 11.05.98 Up, Down Enregistr. données Enter Période mensuelle Durée intégr.15 min Date 00 xx.xx.xx Date Enter 01 4 champs infos xx.xx.xx Date Enter 02 4 champs infos Duré de service xxxxxxxx h xx.xx.xx Date Enter 03 4 champs infos Exit Enter xx.xx.xx Date Enter 04 xx.xx.xx Date Enter 05 4 champs infos 4 champs infos seulement en option "entrée d'impulsions" seulement en option "entrée de courant" (opt.) xx.xx.xx Date Enter 06 4 champs infos xx.xx.xx Date Enter 07 4 champs infos xx.xx.xx Date Enter 08 4 champs infos xx.xx.xx Date Enter xx 4 champs infos xx.xx.xx Date Enter 14 N° de fabr. 03784829 Date fabr. 31.05.97 CALEC MB Ver. 200 N° de fluide Compteur Tarif eau 000 Date xx.xx.xx Et 0000942. kWh seulement en option "entrée de courant" (opt.) Sonde de temp. Pt100 IN1 impulsion xxxxxxx IN1 courant 0...20mA Placement débitmètre IN2 impulsion xxxxxxx Seuil d'inhibition T 0...200 °C Kl. 10/11 Enter Kl. 10/11 Enter c ô t é f r o i d Kl. 56/57 Enter Q 0.000 m3/h valeur d'imp. 1.0000 l 20mA->30.000 m3/h fréquence max. 200 Hz linéaire Enter Date xx.xx.xx E 00002216. kWh 4 champs infos Configuration en usine Enter xx.xx.xx Exit Enter Seuil d'inhibition ∆T 0.00 °C Exit Heure 00:00 xx.xx.xx 3.759526 MW Enter P valeur d'imp. --/-Tarif switch Heure 00:00 xx.xx.xx Q 5.942 m3/h Exit Enter Configuration client Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Fonction xxxxxx OUT3 Enter Kl. 70/71 Fonction xxxxxx OUT4 Enter Kl. 72/73 Fonction xxxxxx OUT5 Enter Kl. 74/75 Fonction xxxxxx OUT6 Enter Kl. 76/77 Fonction xxxxxx OUT7 Enter Kl. 78/79 Fonction Service Enter seulement en option "entrée d'impulsions" seulement en option "entrée de courant" (opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 03.56 mA Tarif2: on/off t = 00000358 s Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# Touches up+down OK Exit Enter xxxxxx OUT8 Enter Kl. 80/81 Fonction xxxxxx OUT9 cptr. durée OUT10 Enter Kl. --/-Enter Kl. --/-- Fonction Fonction cptr. durée M-Bus BAUD = 2400 Enter Kl. 24/25 Adr. 000 Fonction Langue Exit Français Exit Aendern Enter Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Exit Enter Champs facultatifs, visibles seulement en option VD 3-168 DEF 70 Aquametro AG Enter Option ISPC Menu principal Sous menu Affichage visible en option "entrée d'impulsions" IN1 EBS 1.000 L/Imp côté froid Affichage visible en option "entrée de courant" ou = IN1courant 0...20 mA EBS côté froid + EH1 002216.1608 kWh VH1 0259.425303 m3 E1 00002216. kWh V1 000259.42 m3 VH2 0153.873500 m3 V2 000153.87 m3 Champ de texte Affichage visible seulement en cas de message d'erreur Message d'erreur Enter Affichage visible seulement en cas de message d'erreur pas d'erreur HW alarme de temp(hot) Enter Exit Enter Exit Affichage visible seulement en cas de message d'erreur Option Alarm Enter Exit Affichage visible seulement en cas de message d'erreur Exit Overflow Alarm Enter Exit xxxxxxx Alarme Enter Enter E1 00000321. kWh V2 00000026. m3 E1 00001216. kWh V2 000000104. kWh Exit Date réf. 1 30.06.97 Date réf. 1 30.06.97 Date réf. 2 30.12.97 Date réf. 2 30.12.97 Enter Valeurs momentanées Enter P Q Jour de relevé 3.759526 MW 18.247 m3/h Q2 6.735 m3/h Temp. ∆T 175.04 K Fact-k 1.1770 Wh/l/K Date H 180.0 C 4.9 °C Densité 1.00068 kg/l Heure 11.05.98 10.25 10.25 Edit: 11.05.98 Up, Down Enregistr. données Enter Période mensuelle Durée intégr.15 min Date 00 xx.xx.xx Date Enter 01 4 champs infos xx.xx.xx Date Enter 02 4 champs infos xx.xx.xx Date Enter 03 4 champs infos Duré de service xxxxxxxx h xx.xx.xx Date Enter 04 Exit Enter xx.xx.xx Date Enter 05 4 champs infos 4 champs infos seulement en option "entrée d'impulsions" seulement en option "entrée de courant" (opt.) xx.xx.xx Date Enter 06 4 champs infos xx.xx.xx Date Enter 07 4 champs infos xx.xx.xx Date Enter 08 4 champs infos xx.xx.xx Date Enter xx 4 champs infos xx.xx.xx Date Enter 14 4 champs infos Configuration en usine Enter N° de fabr. 03784829 Date fabr. 31.05.97 CALEC MB Ver. 200 N° de fluide Compteur ISPC eau 000 valeur d'imp. 1.0000 l 20mA->30.000 m3/h fréquence max. 200 Hz linéaire Enter Date xx.xx.xx V1 000059.42 m3 seulement en option "entrée de courant" (opt.) Sonde de temp. Pt100 IN1 impulsion xxxxxxx IN1 courant 0...20mA Placement débitmètre IN2 impulsion xxxxxxx Seuil d'inhibition T 0...200 °C Kl. 10/11 Enter Kl. 10/11 Enter c ô t é f r o i d Kl. 56/57 Enter Q 0.000 m3/h xx.xx.xx Exit Enter Date xx.xx.xx E1 00002216. kWh Seuil d'inhibition ∆T 0.00 °C Exit Heure 00:00 xx.xx.xx 3.759526 MW Enter P valeur d'imp. 1.0000 l fréquence max. 50 Hz Heure 00:00 xx.xx.xx Q 18.247 m3/h Exit Enter Configuration client Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Fonction xxxxxx OUT3 Enter Kl. 70/71 Fonction xxxxxx OUT4 Enter Kl. 72/73 Fonction xxxxxx OUT5 Enter Kl. 74/75 Fonction xxxxxx OUT6 Enter Kl. 76/77 Fonction xxxxxx OUT7 Enter Kl. 78/79 Fonction Fonction Service Enter seulement en option "entrée d'impulsions" seulement en option "entrée de courant" (opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 03.56 mA IN 2 f = 0.00 Hz t = 00000358 s Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# xxxxxx OUT8 Enter Kl. 80/81 Touches up+down OK Exit Enter xxxxxx OUT9 cptr. durée OUT10 Enter Kl. --/-Enter Kl. --/-- Fonction Fonction cptr. durée M-Bus BAUD = 2400 Enter Kl. 24/25 Adr. 000 Fonction Langue Français Exit Aendern Enter Exit Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Enter Exit Enter Champs facultatifs, visibles seulement en option Aquametro AG 71 VD 3-168 DEF Option BDE et BDV Menu principal Sous menu Affichage visible en option "entrée d'impulsions" IN1 EBS 1.000 L/Imp côté froid Affichage visible en option "entrée de courant" ou = IN1courant 0...20 mA EBS côté froid + EH+ 02216.1608 kWh VH+ 0259.425303 m3 E+ 00002216. kWh V+ 000259.42 m3 E- 00002216. kWh V- 000153.87 m3 EH- 02216.1608 kWh VH- 0153.873500 m3 Champ de texte Affichage visible seulement en cas de message d'erreur Message d'erreur Enter Affichage visible seulement en cas de message d'erreur pas d'erreur HW alarme de temp(hot) Enter Exit Enter Exit Affichage visible seulement en cas de message d'erreur Option Alarm Enter Exit Affichage visible seulement en cas de message d'erreur Exit Overflow Alarm Enter Exit xxxxxxx Alarme Enter Enter E+ 00000321. kWh E- 00000026. kWh E+ 00001216. kWh E- 00000104. kWh Exit Date réf. 1 30.06.97 Date réf. 1 30.06.97 Date réf. 2 30.12.97 Date réf. 2 30.12.97 Enter Valeurs momentanées Enter P Q Jour de relevé 3.759526 MW Temp. ∆T 175.04 K Fact-k 1.1770 Wh/l/K Date 18.247 m3/h H 180.0 C 4.9 °C Densité 1.00068 kg/l Heure 11.05.98 10.25 10.25 Edit: 11.05.98 Up, Down Enregistr. données Enter Période mensuelle Durée intégr.15 min Date 00 xx.xx.xx Date Enter 01 4 champs infos xx.xx.xx Date Enter 02 4 champs infos Duré de service xxxxxxxx h xx.xx.xx Date Enter 03 4 champs infos Exit Enter xx.xx.xx Date Enter 04 xx.xx.xx Date Enter 05 4 champs infos 4 champs infos seulement en option "entrée d'impulsions" seulement en option "entrée de courant" (opt.) xx.xx.xx Date Enter 06 4 champs infos xx.xx.xx Date Enter 07 4 champs infos xx.xx.xx Date Enter 08 4 champs infos xx.xx.xx Date Enter xx xx.xx.xx Date Enter 14 4 champs infos 4 champs infos Seuil d'inhibition ∆T 0.00 °C Exit Configuration en usine Enter N° de fabr. 03784829 Date fabr. 31.05.97 CALEC MB Ver. 200 N° de fluide Compteur BDE eau ou 000 Compteur BDV valeur d'imp. 1.0000 l 20mA->30.000 m3/h fréquence max. 200 Hz linéaire Enter Date xx.xx.xx E0000942. kWh seulement en option "entrée de courant" (opt.) Sonde de temp. Pt100 IN1 impulsion xxxxxxx IN1 courant 0...20mA Placement débitmètre IN2 impulsion xxxxxxx Seuil d'inhibition Enter Q 0.000 m3/h T 0...200 °C Kl. 10/11 Enter Kl. 10/11 Enter c ô t é f r o i d Kl. 56/57 xx.xx.xx Exit Enter Date xx.xx.xx E+ 00002216. kWh Heure 00:00 xx.xx.xx 3.759526 MW Enter P valeur d'imp. --/-Tarif switch Heure 00:00 xx.xx.xx P1.238545 MW Exit Enter Configuration client Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Fonction xxxxxx OUT3 Enter Kl. 70/71 Fonction xxxxxx OUT4 Enter Kl. 72/73 Fonction xxxxxx OUT5 Enter Kl. 74/75 Fonction xxxxxx OUT6 Enter Kl. 76/77 Fonction xxxxxx OUT7 Enter Kl. 78/79 Fonction Service Enter seulement en option "entrée d'impulsions" seulement en option "entrée de courant" (opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 03.56 mA Débit : positif t = 00000358 s Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# Touches up+down OK Exit Enter xxxxxx OUT8 Enter Kl. 80/81 Fonction xxxxxx OUT9 cptr. durée OUT10 Enter Kl. --/-Enter Kl. --/-- Fonction Fonction cptr. durée M-Bus BAUD = 2400 Enter Kl. 24/25 Adr. 000 Fonction Langue Exit Français Exit Aendern Enter Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Exit Enter Champs facultatifs, visibles seulement en option Champs facultatifs, visibles seulement en option "BDV" VD 3-168 DEF 72 Aquametro AG Enter Option Twin E et Twin V Menu principal Sous menu Affichage visible en option "entrée d'impulsions" IN1 EBS Affichage visible en option "entrée de courant" 1.000 L/Imp côté froid ou = IN1courant 0...20 mA EBS côté froid + EH1 02216.1608 kWh VH1 0259.425303 m3 E1 00002216. kWh V1 000259.42 m3 E2 00002216. kWh V2 000153.87 m3 EH2 02216.1608 kWh VH2 0153.873500 m3 Champ de texte Affichage visible seulement en cas de message d'erreur Message d'erreur Enter Affichage visible seulement en cas de message d'erreur pas d'erreur HW alarme de temp(hot) Enter Exit Enter Exit Affichage visible seulement en cas de message d'erreur Option Alarm Enter Exit Affichage visible seulement en cas de message d'erreur Exit Overflow Alarm Enter Exit xxxxxxx Alarme Enter Enter E 1 0 0 0 0 0 3 2 1 . k W h E2 00000026. kWh E 1 0 0 0 0 1 2 1 6 . k W h E2 00000104. kWh E x i t D a t e r é f . 1 3 0 . 0 6 . 9 7 D a t e r é f . 1 30.06.97 D a t e r é f . 2 3 1 . 1 2 . 9 7 D a t e r é f . 2 31.12.97 Enter Valeurs momentanées Enter P Q Jour de relevé 3.759526 MW P2 18.247 m3/h Q2 0.975246 MW Temp. ∆T 175.04 K Fact-k 1.1770 Wh/l/K Date 4.682 m3/h H 180.0 C 4.9 °C Densité 1.00068 kg/l Heure 11.05.98 10.25 10.25 Edit: 11.05.98 Up, Down Enregistr. données Enter Période mensuelle Durée intégr.15 min Date 00 xx.xx.xx Date Enter 01 4 champs infos xx.xx.xx Date Enter 02 4 champs infos xx.xx.xx Date Enter 03 4 champs infos Duré de service xxxxxxxx h xx.xx.xx Date Enter 04 Exit Enter xx.xx.xx Date Enter 05 4 champs infos 4 champs infos seulement en option "entrée d'impulsions" seulement en option "entrée de courant" (opt.) xx.xx.xx Date Enter 06 4 champs infos xx.xx.xx Date Enter 07 4 champs infos xx.xx.xx Date Enter 08 xx.xx.xx Date Enter 09 xx.xx.xx Date Enter 10 4 champs infos 4 champs infos 4 champs infos seulement en option "entrée de courant" 2 (opt.) seulement en option "entrée de courant" 2 (opt.) seulement en option "entrée de courant" 2 (opt.) xx.xx.xx Date Enter xx 4 champs infos xx.xx.xx Date Enter 14 Configuration en usine Enter N° de fabr. 03784829 Date fabr. 31.05.97 CALEC MB Ver. 200 N° de fluide Compteur Twin-E eau 000 Sonde de temp. Pt100 I N 1 i m p u l s i o n x x x x x x x I N 1 c o u r a n t 0 . . . 2 0 m A P l a c e m e n t d é b i t m è t r e I N 2 i m p u l s i o n x x x x x x x I N 2 c u r r e n t 0 . . . 2 0 m A S e u i l d ' i n h i b i t i o n T 0...200 °C Kl. 10/11 Enter Kl. 10/11 Enter côté froid Kl. 56/57 Enter Kl. 56/57 Enter Q 1.000 m3/h ou Compteur Twin V valeur d'imp. 1.0000 l 20mA->30.000 m3/h fréquence max. 200 Hz linéaire xx.xx.xx Exit Enter Enter Date xx.xx.xx E1 00002216. kWh 4 champs infos Date xx.xx.xx V 00000942. m3 Seuil d'inhibition Seuil d'inhibition Q2 0.000 m3/h ∆T 0.00 °C Exit Option Twin-V seulement Date xx.xx.xx Option Twin-E seulement E n t e r E2 00000942. kWh valeur d'imp. 1.000 l 2 0 m A - > 2 4 . 0 0 0 m 3 / h fréquence max. 50 Hz linéaire Heure 00:00 xx.xx.xx P1 3.759526 MW Heure 00:00 xx.xx.xx Option Twin-V Q 1.238545 m3/h seulement Heure 00:00 xx.xx.xx Option Twin-E P2 1.238545 MW seulement Configuration client Enter OUT1 Kl. 50/51 xxxxxx OUT2 Enter Kl. 52/53 Fonction xxxxxx OUT3 Enter Kl. 70/71 Fonction xxxxxx OUT4 Enter Kl. 72/73 Fonction xxxxxx OUT5 Enter Kl. 74/75 Fonction xxxxxx OUT6 Enter Kl. 76/77 Fonction xxxxxx OUT7 Enter Kl. 78/79 Fonction xxxxxx OUT8 Enter Kl. 80/81 Fonction Service Enter seulement en option "entrée d'impulsions" seulement en option "entrée de courant" (opt.) IN 1 f = 5.06 Hz t = 00000000 s IN1 I = 12.16 mA seulement en option "entrée de courant" 2 (opt.) IN 2 f = 0.00 Hz t = 00000358 s IN2 I = 7.12 mA Lock level 1 Exit M-Bus access 0002134 Enter ################# ################# xxxxxx OUT9 cptr. durée OUT10 Enter Kl. --/-Enter Kl. --/-- Fonction Touches up+down OK Exit Enter Fonction cptr. durée M-Bus BAUD = 2400 Enter Kl. 24/25 Adr. 000 Fonction Langue Exit Français Exit Aendern Enter Exit Enter Enter Deutsch Enter Exit English Enter Exit Français Enter Exit Italiano Enter Exit Enter Champs facultatifs, visibles seulement en option Champs facultatifs, visibles seulement en option "Twin E" Aquametro AG 73 VD 3-168 DEF VD 3-168 DEF 74 Aquametro AG Aquametro AG 75 VD 3-168 DEF Änderungen vorbehalten Sous réserve de modifications Modification rights reserved copyright © Aquametro AG AQUAMETRO SA Ringstrasse 75 CH-4106 Therwil Tel. 061 725 11 22 Fax 061 725 15 95 [email protected] Rue du Jura 10 CH-1800 Vevey Tel. 021 923 51 30 Fax 021 922 58 44 [email protected] AQUAMETRO MESSTECHNIK GmbH Zum Panrepel 24 D-28307 Bremen Tel. 0421 / 871 64-0 Fax 0421 / 871 64-19 [email protected] AQUAMETRO BELGIUM SPRL Bd. Lambermont 131 B-1030 Bruxelles Tel. 02 / 241 62 01 Fax 02 / 216 22 63 [email protected] AQUAMETRO s.r.o. Prosecká 811 / 76a CZ-190 00 Praha 9 Tel. 02 / 86 88 77 78 Fax 02 / 86 88 95 59 [email protected] A1 - 06.2005 - Art.-Nr. 11633 www.aquametro.com AQUAMETRO AG