Gestion active de la demande énergétique, une approche

Transcription

Gestion active de la demande énergétique, une approche
Stignergy SA
Y-Parc – Swiss Technopole
Rue Galilée 7
CH – 1400 Yverdon-Les-Bains
«Gestion active de la demande énergétique,
une approche biomimétique»
Sami Najjar, CEO
[email protected]
M. +41 76 223 53 15
Journée Aristote
Du 3 juin 2014
École polytechnique
Palaiseau
Vision & Mission: Global leader of Control & Optimization
of Electrical Energy Demand for professionals
Locations:
Stignergy SA - Headquarters & Busdev
Y-Parc – Swiss Technopole
Yverdon-les-Bains (CH)
Ra&D - Logistics Branch Office – Tunis
Founded:
HEIG-VD SpinOFF
Yverdon-les-Bains, November 2012
Personnel:
5
Ra&D
Expected Revenue:
2009 – 2015 Budget CHF 3 million
CHF 4 million in 2016
Team
Sami Najjar: CEO & Founder
HES engineer graduated. Senior Telecom & IT Engineer Cable & Wireless
Startup experience: Keycom SA founder from 2004 to 2008
Alexandre Wetzel: CTO
MS in Communication System EPFL
Software development specialist in networking and mobility
Montassar Ben Abdallah: Logistic & Quality Manager
Electronics engineering graduated from the National School of Engineers of
Tunis (ENIT). PFE HEIG-VD Switzerland.
Youssef Sahbi: Software Engineer
Ghada Dhibi: Hardware Engineer
Software engineering graduated from
the National School of Engineers of
Tunis (ENIT). PFE HEIG-VD
Switzerland.
Electronics engineering graduated
from the National School of
Engineers of Tunis (ENIT). PFE
HEIG-VD Switzerland.
Challenge
Energy Consump.on kWh Solution’s aim
•  Bill reduction : 10 to 15% and ++
•  10’000 CHF/year for a medium hotel (from 265 kW to 186 kW)
Power [kW]
Power Heat Pump
[kW]
Fridge
Washing Machine
Computer, Light,…etc.
Energy demand
Peak demand not controlled
Heat Pump
Fridge
Peak demand controlled
Washing Machine
Fridge
Fridge
Computer, Light,…etc.
11:00
11:15
11:30
11:45
12:00
12:15
12:30
11:00
11:15
11:30
11:45
12:00
12:15
12:30
SEMS: Smart Energy Management System
Benefit
SEMS services
Philosophie
"   Bio-­‐inspiré : Intelligence ar.ficielle inspiré de la nature, du comportement des insectes sociaux. Le cas des abeilles vivant en essaim : l’échange d'informa.on entre elles (la distance, la direc.on, la quan.té et la nature de la nourriture) fait que, globalement, elles arrivent à résoudre des problèmes difficiles, (exploita.on de sources de nourriture, construc.on de rayons,…etc.). "   Une “intelligence collec.ve” émerge de l’interac.on entre des agents rela.vement simples. "   L’ac.on collec.ve des agents trouve des solu.ons au problème sans aucun superviseur. "   Stignergy est inspiré des principes de la ‘S.gmergie’ qui se réfère au comportement d’insectes sociaux. SEMS Assembly
Measurements series
Appliances usage
Unpredictable appliances
(Unknown start date, unknown duration )
[P]
ON/OFF
Decision
ON/OFF
Decision
semi-predictable appliances
(Unknown start date, known duration )
[ P, T ]
SEMS
Algorithm
ON/OFF
Decision
Predictable appliances
(Known start date, known duration)
[ P, T, earliest date, latest date]
Appliances behavior
Service
Electrical duty cycle
Permanent
Temporary
Periodic
Aperiodic
Pilotable
Non-pilotable
Pilotable
Modifiable
Interruptible
(Deleting)
(Interrupt)
Shiftable
(Postponing)
Non-pilotable
SEMS actions
Energy
demand
Average
demand
11h00
11h15
11h30
11h45
SEMS actions
1. Postponing the start
2. Deleting a cycle
3. Interrupt the appliance
Energy
demand
Average
demand
11h00
11h15
11h30
11h45
SEMS operations
Two phases
•  Learning
– The terminals just measure the electrical
consumption
– Duration: about one week
•  Executing
– The terminals are active and decide to switch
ON or OFF their associated appliance
– Optimizations start in this phase
SEMS Learning - Profiles
Profiles are used to represent the consumption of a device based on
measurements and observations
Real measurements Intensity [A] 1,00 0,80 0,60 0,40 0,20 1 11 21 31 41 51 61 71 81 91 101 111 121 0,00 Time [min] 0,8 0,6 0,4 0,2 0 1 10 19 28 37 46 55 64 73 82 91 100 109 118 127 Profile Intensity [A] 1 Time [min] SEMS Learning - Profiles
Learning - Profiles list
•  Thermic and Thermic clock
•  Simple blocks
•  Average 15 (Avg15)
•  More…
SEMS Scope
•  Energy Storage Management:
 
Better valuation of local power production like photovoltaic panel
 
More Energy demand reduction -> More bill reduction
CTI grant 621K CHF – Stignergy industrial partnership with Leclanché (Yverdon)
& academic partnership, MIS of HEIG-VD (Yverdon)
•  SmartGrid integration: SEMS
 
Enable two-way communication between the energy consumer and the
energy supplier central system
 
Provide prediction charge to the balance of Demand/Response
Competition
+
Features Dynamic SEMS-­‐EDCO Decentralized System Efficiency Reliability Live reports Centralized Building Management Load Shedding StaAc System Roadmap: •  Energy Storage Management : SEMS-­‐ESCO •  SmartGrid IntegraAon – Demand/Response : SEMS-­‐GridExchange •  M2M Environment : SEMS-­‐M2MEnviro + Advantages Easy installaAon Low investment Fast amorAzaAon Simplicity of use VersaAlity Robustness Value proposition
•  Plug & Reap Savings: 10 to 15% or more of electricity bill
•  Low Investment: Amortization in 24 to 30 months
•  Easy Installation: Max 30 min/Terminal, with simple screwdriver
•  Maintenance-Free: No monitoring or maintenance required
•  Large Versatility: Applicable to many types & sizes of buildings or
equipments
•  Live Reports: data in real-time
Market
The industry and services absorb more than 50% of all electricity consumed in
Switzerland. 3% only by the pharma industry*. The figures are basically the
same in all Europe.
1st Target Segment: Swiss Hotel Market 2ed Target Segment: Swiss Industry Market 1 000 2 100 8 600 4 400 Monthly Electricity bill ++ : –> CHF 40K –> 1K Hotels –> CHF 44 M * http://www.scienceindustries.ch/industrie/industrieportraet/_detail-657/106/energieverbrauch
–> CHF 100K –> ++ 2K Industrial Sites –> ++ CHF 220 M Questions & Responses