Philips Lighting Company - Achat
Transcription
Philips Lighting Company - Achat
Philips Lighting Company Lamp Material Data Sheet (LMDS) LMDS #: CFN – 10001A Date: 03/15/2011 Product: Philips Compact Fluorescent Lamps CFL-ni – All Types ALTO and non-ALTO: PL-C, PL-H, PL-L, PL-Q, PL-S, PL-T Page 1 of 2 Section 1. Manufacturer and Contact Information Philips Lighting Company Division of Philips Electronics North America Corporation 200 Franklin Square Drive Somerset, NJ 08873-4186 24 HR Emergency Phone Number: Other Information Calls: (800) 424-9300 CHEMTREC (800) 555-0050 Philips Lighting Technical Information Section 2. Hazardous Ingredients/Identity Information These lamps may contain the following materials: Material Inert Materials (glass/metals) Phosphor Powder (as Nuisance Dust) Yttrium Oxide (as Yttrium) Barium Magnesium Aluminate Cerium Magnesium Aluminate Indium Bismuth Mercury Isotope (Kr85 or H3) (CAS #) Exposure Limits in Air OSHA PEL (1314-36-9) (63774-55-0) (67542-72-7) (7740-74-6) (7440-69-9) (7439-97-6) (713983-27-2/10028-17-8) mg/m3 15 1 n/a n/a 0.1 0.1 0.1 - ACGIH TLV mg/m3 10 1 n/a 10 0.1 n/a 0.025 - PERCENTAGE by weight ~98.0% <2.0% <0.5% <0.1% <0.1% <0.15% <0.15% <0.025% <100ηCi The Phosphor Powder materials are ceramic phosphors. The ceramics are Cerium/Barium Aluminate and Yttrium Oxide. The PEL and TLV are given where available for the base materials. There is no data for the ceramics as mixtures. Section 3. Physical Properties Not applicable to an intact lamp. These items are light bulbs in various shapes, configurations, and designs. All contain small glass fluorescent tubes, a plastic housing, and various pin-style bases for use in specific fixtures/sockets. Some lamps may contain isotopes (nanoCurie quantities) to aid in lamp starting - Product packaging is appropriately labeled. Section 4. Fire and Explosion Hazards Not applicable to an intact lamp. If subjected to extreme heat, the plastic and glass components of the lamp may crack or melt and the lamp may emit toxic fumes. Philips Lighting Company 200 Franklin Square Drive Somerset, NJ 08873-4186 Tel: 732.563.3000 A Division of Philips Electronics North American Corporation Section 5. Reactivity Not applicable to an intact lamp. Section 6. Health Hazards Not applicable to an intact lamp. Breakage of the lamp may result in some exposure to the phosphor powder and to elemental mercury. No adverse effects are expected from occasional exposure to broken lamps, but as a matter of good practice, prolonged exposure should be avoided through the use of adequate ventilation during the disposal of large quantities of lamps. Emergency and First Aid Procedures: Apply normal first aid for glass cuts if such should occur through lamp breakage. Section 7. Lamp Disposal Procedures Normal precautions should be taken for the collection of glass particles in the event a lamp is broken. Waste Disposal Method: All compact fluorescent lamps contain some amount of mercury. When a compact fluorescent lamp is to be disposed, it is subject to the current EPA Toxicity Characteristic Leaching Procedure (TCLP) disposal criteria. This test is used to determine if an item can be managed of as hazardous or non-hazardous waste. Philips low-mercury ALTO compact fluorescent lamps are identifiable by their characteristic green logo. Philips ALTO lamps are TCLP compliant and can be managed as non-hazardous waste. Philips will provide TCLP test data upon request. Philips non-ALTO lamps (with black logo) are not TCLP compliant and should be managed as a hazardous waste under the EPA Universal Waste Rules for fluorescent lamps. All disposal options should be evaluated with respect to federal, state, and local requirements. Before disposing of waste lamps, check with federal, state, and/or local officials for current guidelines and regulations. Philips encourages recycling of its products through qualified recycling facilities. Section 8. Control Measures Respiratory Protection: None. NIOSH-approved respirator should be used if large quantities of lamps are being broken for disposal. Ventilation: Avoid inhalation of any airborne dust. Provide local exhaust when disposing of large quantities of lamps. Hand and Eye Protection: Appropriate hand and eye protection should be worn when disposing of lamps and/or handling broken glass. Section 9. Regulatory Information As a product, these mercury-containing lamps, when shipped in the manufacturer’s original packaging, are not regulated by air, truck, or ocean shipment. As a waste, these lamps may be regulated in various states and local communities. This safety data sheet does not constitute “knowledge of the waste” in certain jurisdictions. This document supercedes previous document: LMDS CFN-10001, last revised 07/30/2010 Occupational Health and Safety Administration (OSHA) Material Safety Data Sheet (MSDS) requirements for materials are not applicable to manufactured articles in which individuals would not be subjected to materials contained in the article during its normally intended use. The information in this document is provided as a courtesy and is intended to provide relevant information in the event the articles it covers are encountered during unintended, or abnormal, circumstances. MASTER PL-T 4 Broches MASTER PL-T 42W/840/4P 1CT Lampe fluocompacte à alimentation séparée Nouvelle base miniaturisée Lampe à 6 tubes parrallèles Données du produit • Caractéristiques Générales Culot Information culot Durée de vie moy B. cat chaude Durée de vie moy B. cat froide EL sans prech. (10% de mort) Durée de vie EL CC (10% mort) LSF HF Preheat 12000h Rated,3h LSF HF Preheat 8000h Rated,3h LSF HF Preheat 6000h Rated,3h LSF HF Preheat 4000h Rated,3h LSF HF Preheat 2000h Rated,3h GX24q-4 4P 13000 hr 7000 hr 4500 hr 8000 hr 60 % 90 % 97 % 98 % 99 % • Caractéritiques techn. de lumière Code couleur Indice de rendu des couleurs Désignation teinte Température de couleur Coordonnée chromatique X Coordonnée chromatique Y Eff Lum sur ball HF à 25°C 840 [CCT of 4000K] 82 Ra8 Blanc brillant 4000 K 380 379 74 (min) Lm/W LLMF HF 12000h Rated LLMF HF 8000h Rated LLMF HF 6000h Rated LLMF HF 4000h Rated LLMF HF 2000h Rated Luminous Flux EL 25°C, Rated Luminous Flux EL 25°C, Nominal Design Temperature 81 % 84 % 86 % 88 % 92 % 3050 Lm 3200 Lm 28 C • Caractéristiques électriques Puissance lampe Tension lampe ballast EL 25 °C Courant lampe, ballast EL 25° Gradable Lamp Wattage EL 25°C, Rated Puiss. nom. lampe EL à 25°C 42 W 125 V 0.320 A Oui 41.0 W 42 W • Caractéristiques environnementales Label d'efficacité energétique Contient du mercure B 1.4 mg MASTER PL-T 4 Broches • Conditions de mesure Calibration Current HF Generator Rated Voltage Resistor 0.320 A 270 V 420 ohm • Dimensions en mm. Longeur culot - culot A Longueur insertion B Longeur totale C Diamètre ampoule D 120.7 (max) mm 145.0 (max) mm 160.7 (max) mm 41.0 (max) mm Code produit EOC Nom produit Désignation Pièces par pack Config. Emballage Packs par carton Code barre produit EAN 2 Code barre carton regroup. Code usine Code ILCOS Poids net unitaire 871150061137670 MASTER PL-T 42W/840/4P 1CT MASTER PL-T 42W/840/4P 1CT/ 5X10CC 1 5X10CC 50 8711500611376 8711500611383 8711500611390 927914884071 FSMH-42/40/1B-L/P-GX24q=4 83.000 gr • Données produit Code commercial 611376 70 Mises en garde et sécurité • Shorter lamp life when often switching and not well pre-heated electrodes • Lamp light technical and electrical characteristics are influenced by operating conditions, i.e. lamp ambient temperature and operating position as well as applied HF control gear Schéma dimensionnel GX24q-4, 4P D Product A (Max) B (Max) C (Max) D (Max) 145.0 160.7 41.0 C B A PL-T 42W/840/4P M 120.7 24 GX24q-4 2011, décembre 21 Les données sont sujettes à changement MASTER PL-T 4 Broches W per 5 nm per lm µW per 5 nm per Données photométriques 500 400 300 500 400 300 200 200 100 100 300 400 500 600 700 l nm 300 400 Lightcolor /840 500 600 700 λ nm Lightcolor /840 © 2011 Koninklijke Philips Electronics N.V. Tous droits réservés. Les données sont sujettes à changement sans préavis. Les noms et marques sont la propriété de Koninklijke Philips Electronics N.V. ou de leurs ayants droits respectifs. www.philips.com/lighting 2011, décembre 21 Les données sont sujettes à changement