L`essai de compression uniaxiale est effectué sur une

Transcription

L`essai de compression uniaxiale est effectué sur une
In the standard Huder-Amberg swelling test, the
sample is first subjected to a cycle of load, unload
and reload "dry" (water content of reception). The
sample is then flooded with water, at the maximum
stress. It is subsequently unloaded step by step, for
each of which the stress is maintained constant until
stabilization of swelling.
LABORATOIRES DE MECANIQUE DES SOLS ET DES ROCHES
Exécuté selon la norme ISRM-89 et LMS+R ER.410
Titre de l'étude
R0335FMC30_229
Moutier-Court
Type échantillon
FMC30
carotte
Profondeur
Mode
conservation
22.9
The swelling curve corresponds to the instantaneous
strain of the material’s matrix consecutive to the
reduction in the axial loading added to the swelling
caused by the adsorption of water by argillaceous
minerals. The difference between the swelling curve
and the instantaneous strain curve underwater
defines the swelling potential.
GONFLEMENT
Exécuté selon la norme ISRM-89 et LMS+R ER.410
No échantillon
No sondage
m
Commettant
nom
Nature échantillon
sciage
Poids vol. app.
60
Titre de l'étude
R0335FMC30_229
Moutier-Court
Date réception
Date essai
No sondage
28.10.94
1.11.94
marne
Mode
préparation
Diamètre
mm
No échantillon
Diesse
mm
Ingénieur responsable
nom
signature
Opérat.
J.-F. Mathier
19.8 kN/m3
JM
w initiale
w finale
21.8 %
28.0 %
FMC30
carotte
Mode
conservation
22.9
o
15.02
12.0
The swelling pressure test is intended to
measure the pressure necessary to maintain
the sample at constant volume when it is
immerged in water. Swelling stress and
axial strain are recorded as a function of
time. Small amounts of swelling strain are
compensated in a step-wise manner by
increase of stress. The value of stress at
which no further swelling strain is observed
is called “swelling pressure”.
mm
Nature échantillon
chambre humide
sciage
Diamètre
Poids vol. app.
60
Date essai
28.10.94
1.11.94
marne
Mode
préparation
mm
Diesse
Date réception
Ingénieur responsable
nom
signature
Opérat.
J.-F. Mathier
w initiale
19.8 kN/m3
21.8 %
JM
w finale
28.0 %
12.0
Paliers de décharge sous eau [kPa]
cycles de charge
gonflement
def. instantanée sous eau
10.0
8.0
10.0
8.0
6.0
999
500
250
125
60
15
1.1
eau
6.0
4.0
Déformation [%]
Déformation [%]
Two other tests can be carried out: the free
swell test which consists in measuring the
axial and radial swelling strain of the
sample during its immersion in water.
m
Hauteur
adresse
P. Dauwalder
Type échantillon
Profondeur
4.0
o
Commettant
nom
adresse
P. Dauwalder
chambre humide
Hauteur
15.02
LABORATOIRES DE MECANIQUE DES SOLS ET DES ROCHES
GONFLEMENT
gonflement
2.0
0.0
2.0
0.0
-2.0
-2.0
-4.0
-4.0
-6.0
-6.0
-8.0
-8.0
-10.0
-10.0
1
10
100
1000
Contrainte [kPa] 10000
0.1
1.0
10.0
100.0
1000.0
10000.0
temps [min]
Observations:
Essai accrédité
oui
non
Ce protocole ne peut être reproduit partiellement sans l'accord écrit du LMR-EPFL
Example of Huder-Amberg swelling test
Page 1/2
Observations:
Essai accrédité
oui
non
Ce protocole ne peut être reproduit partiellement sans l'accord écrit du LMR-EPFL
Strain vs time
Page 2/2

Documents pareils