Time Switch Bro_4KT01
Transcription
Time Switch Bro_4KT01
AlphaRex pre-program some leisure time P R E - P R O G R A M M A B L E / T I M E S W I TC H www.legrand.com.au AlphaRex time switch easy to use Create Name your program Select the times by dragging your mouse across the graph Click here to create your program settings below Confirm Tick the verify box to confirm your settings Copy Click here to copy your program to the data key Easy programming Use the intuitive AlphaRex software to create your program on PC and save it for later reference. Then transfer the program to the data key. lets you work faster Flexible and Convenient The data key is the perfect solution for applying different programs to various time switches. It makes transferring and copying data easier for you. AlphaRex to PC Use the software with the data key to increase accuracy and efficiency in your work. Transfer data from: PC to AlphaRex AlphaRex to AlphaRex Data key: • transfer data • portable storage device • can also be safely stored in the AlphaRex • secure back up gives you more time to play Quick and Easy AlphaRex includes a host of additional functions making it easier to programme. • Holiday program - enter the start and end dates then the programming will automatically return to normal mode. • Pulse function - available on one channel version, used for timed pulse operation (eg. school bells) • Random mode - simulates your presence by turning lights ON and OFF on different days and times. • Hour counter - will count the sum of all times the controlled load (eg. lamps, motors) has been ON per channel, plus the date of the last reset. For a demonstration, contact your local Legrand representative Programs at a glance On-screen instructions Real time display Back-lit screen and buttons 4 button operation AlphaRex time switch AlphaRex time switch DIN rail mounting DIN rail mounting n Technical data Type 047 61 Pack Cat. Nos AlphaRex D21 Accuracy: ± 0.2 second per day Clearly visible LCD matrix day shows the data at a glance Programmable for 1 minute minimum at 1 minute steps either as 24 hour or 7 day using pre-set groups of days: Mon-Sun, Mon-Fri, Sat-Sun or individual days Programmable either directly on the time switch or via a PC with the Legrand software and data key Data keys can also be used to transfer programs from one unit to another or used to store data and provide security back up 1 program consists of 1 ON and OFF time and the allocation of single days or a combination of days, plus the selected channel on the two channel version Additional features: Built in hour counter up to 65535 hours with reset Back lit display and buttons to make working easy Lithium high temperature battery: 6 year working reserve EEPROM keeps your program stored indefinitely Optional automatic daylight savings function Manual override (permanent ON/OFF until manual reset) Automatic override, changes contact position until next automatic ON time (ON becomes OFF, OFF becomes ON, until next programmed ON) Sealable transparent cover with or without data key inside Holiday and random security programs D21 version includes a PULSE function with up to 84 starts from 1 second to 59 minutes 59 seconds duration 1 047 61 AlphaRex D21 24 hour or 7 Day, 1 channel 230 V, 50/60 Hz 1 changeover (SPDT) 250 V/50 Hz, 16 A~ cos=1 56 programs min. switching time: 1 min switching stem: 1 min AlphaRex D22 24 hour or 7 day, 2 channels 230 V, 50/60 Hz 2 changeover (SPDT)250 V/50 Hz, 16 A~ cos=1 56 programs (28 per channel) min. switching time: 1 min switching stem: 1 min 1 047 71 1 047 72 Data key Transfer data into time switch PC programmable Can also be used as a back up 1 047 73 USB-adaptor To read and write data keys on a PC Software included Connection via USB-port System requirements: Windows®2000, Windows®ME, Windows®XP and Windows®98 second Edition, 10 MB free disc space Serial adaptor on demand GST applies to ALL products operating temperature protection 2 1 2 6 years 1 min 1 min 0.2 sec/day 16 A~ 8 A~ 10 A~ 1 SPDT 56 84 min.1 sec max. 59 min, 59 sec – 20 °C 2 SPDT 28p. chan. - +55 °C IP20 1) A program consists of an ON and an OFF time and the assigned days. n Wiring Diagram AlphaRex D21 AlphaRex D22 n Dimensions (mm) 36 50 45 047 72 no. of modules (17.5 mm) no. of channels running reserve switching step min. switching time accuracy switching capacity • resistive 230 V~cos =1 • incandescent lamps 230 V • inductive 230 V~cos =0,6 contact programs pulse start times pulse duration AlphaRex D22 83 047 73 AlphaRex D21 66 Sales offices: New South Wales Tel: (02) 8748 0300 Fax: (02) 9737 9299 Email: [email protected] Northern New South Wales Tel: (02) 4946 5064 Fax: (02) 4946 5623 Email: [email protected] Southern New South Wales & ACT Mobile: 0409 427 875 Fax: (02) 6288 5573 Email: [email protected] Victoria Tel: (03) 9416 9288 Fax: (03) 9484 1409 Email: [email protected] Tasmania - Agent Tel: (03) 6273 0577 Fax: (03) 6273 0575 Email: [email protected] Queensland Tel: (07) 3348 9440 Fax: (07) 3348 9474 Email: [email protected] Northern Queensland - Agent Tel: (07) 4762 7588 Fax: (07) 4775 6057 Email: [email protected] South Australia & Northern Territory Tel: (08) 8323 9886 Fax: (08) 8323 9887 Email: [email protected] www.legrand.com.au 3/107 Carnarvon Street Silverwater NSW 2128 Tel: (02) 8748 0333 Fax: (02) 9737 8211 Designed and printed in Australia - 2041 45 Western Australia Tel: (08) 9477 2100 Fax: (08) 9477 2177 Email: [email protected]