NEEDLE ovum pick-up
Transcription
NEEDLE ovum pick-up
gynecology products ovum pick-up NEEDLE Ovum Pick-up Needle - Double Lumen and Single Lumen Double Lumen GTA Stainless steel ovum pick up needle is especially designed to harvest ovocyte from follicles. Echomarker Stainless steel Double lumen Needle Issuing Body: COM - May '04 Last Revision: '00 GTA’ SLD is available in two different configurations: single lumen or double lumen (to flush or aspirate without any other adjustment). Single Lumen Flushing line Echomarker Vacuum cannula Silicone Flacon Tube Stopper Stainless steel Single lumen Needle Aspiration line Aspiration line Vacuum cannula Silicone Stopper High resolution echogenic tip. Handle for easy control and orientation of the needle point. The triple sharpned point assures easy and smooth penetration of ovarian stroma. Tubing set with luer lock to connect the tube to the vacum regulator. Flushing line (Double Lumen). Order code SLD 1628 SLD 1632 SLD 1828 SLD 1832 Single Lumen Order code SLD 1628D SLD 1632D SLD 1828D SLD 1832D Decreption Ga x cm Single Lumen 16ga x 28cm Single Lumen 16ga x 32cm Single Lumen 18ga x 28cm Single Lumen 18ga x 32cm Decreption Ga x cm Double Lumen 16ga x 28cm Double Lumen 16ga x 32cm Double Lumen 18ga x 28cm Double Lumen 18ga x 32cm Pcs Per box 10 10 10 10 Pcs Per box 10 10 10 10 Double Lumen On request it is possible to order needles with different lengths and diameters GTA MEDICAL PRODUCTS GTA S.r.l. via della Vittoria, 5 46026 Quistello (MN) Italy Tel. +39 0376 625300 Fax +39 0376 625279 E-mail: [email protected] gynecology products FOLLICLE ASPIRATION set AND NEEDLE 2 The GTA Follicle Aspiration Set has been developed for ovocyte retrieval through the aspiration of the follicular fluid. Connecting the stainless steel needle to the connecting tube, the follicular fluid will be aspirated into a syringe. Follicle Aspiration Needle 4 Echogenic Tip Follicle Aspiration6 8 Set 10 20 18 16 14 12 Stainless steel Single lumen Needle Stylet Echogenic Tip 2 6 4 8 12 10 14 18 16 20 2 4 6 8 10 12 14 16 18 20 Stainless steel Single lumen Needle Follicle Aspiration Set he GTA Follicle Aspiration Needle is especially designed for transvaginal puncture of follicles in order to retrieve ovocytes. A luer attachment provides for easy connection between needle and syringe. Order code Description ga x cm Tubing Length cm Pcs Per box FGTC 1725 FGTC 1730 FGTC 1625 FGTC 1630 FGTC 1635 17ga x 25cm 17ga x 30cm 16ga x 25cm 16ga x 30cm 16ga x 35cm 40 40 40 40 40 10 10 10 10 10 On request it is possible to order needles with different lengths and diameters Issuing Body: COM - May '04 Last Revision: '00 Follicle Aspiration Needle Order code Description ga x cm Pcs Per box FGT 1830 FGT 1725 FGT 1730 FGT 1625 FGT 1630 18ga x 30cm 17ga x 25cm 17ga x 30cm 16ga x 25cm 16ga x 30cm 10 10 10 10 10 On request it is possible to order needles with different lengths and diameters GTA MEDICAL PRODUCTS GTA S.r.l. via della Vittoria, 5 46026 Quistello (MN) Italy Tel. +39 0376 625300 Fax +39 0376 625279 E-mail: [email protected] gynecology products NEEDLE FOR AMNIOCENTESIS Echogenic Tip Issuing Body: COM - May '04 Last Revision: '00 Stainless steel Single lumen Needle Stylet Especially designed for ultra-sound guided amniocentesis The needle is made of high quality stainless steel, has an echogenic tip and luer lock connection and the perfect length (180 or 140) for use with a needle guide Needle for Amniocentesis Order code Description ga x cm Pcs Per box UATT 2314 UATT 2114 UATT 2118 23ga x 14cm 21ga x 14cm 21ga x 18cm 10 10 10 On request it is possible to order needles with different lengths and diameters GTA MEDICAL PRODUCTS GTA S.r.l. via della Vittoria, 5 46026 Quistello (MN) Italy Tel. +39 0376 625300 Fax +39 0376 625279 E-mail: [email protected] gynecology products CHORION BIOPSY NEEDLE Echogenic Tip Stainless steel Single lumen Issuing Body: COM - May '04 Last Revision: '00 Needle Stylet This stainless steel needle has been developed to execute ultra-sound guided chorion biopsy The GTA Chorion Biopsy Needle is provided with stylet, echogenic tip and luer lock connection for attaching a syringe Chorion Biopsy Needle Order code Description ga x cm Pcs Per box UASS 2015 UASS 2018 UASS 2030 20ga x 15cm 20ga x 18cm 20ga x 30cm 10 10 10 On request it is possible to order needles with different lengths and diameters GTA MEDICAL PRODUCTS GTA S.r.l. via della Vittoria, 5 46026 Quistello (MN) Italy Tel. +39 0376 625300 Fax +39 0376 625279 E-mail: [email protected] gynecology products NEEDLE FOR CYST PUNCTURE Echogenic Tip The GTA Needle for Cyst Puncture is designed to perform ultrasound-guided puncture of intra-abdominal cysts This needle is supplied with a stylet, echogenic tip and a luer lock which allows an easy connection to the syringe Stainless steel Stylet Single lumen Needle Issuing Body: COM - May '04 Last Revision: '00 Needle for Cyst Puncture Order code Description ga x cm Pcs Per box SOL 1814 SOL 1825 SOL 1830 SOL 1835 SOL 1730 SOL 1625 SOL 1630 18ga x 14cm 18ga x 25cm 18ga x 30cm 18ga x 35cm 17ga x 30cm 16ga x 25cm 16ga x 30cm 10 10 10 10 10 10 10 On request it is possible to order needles with different lengths and diameters GTA MEDICAL PRODUCTS GTA S.r.l. via della Vittoria, 5 46026 Quistello (MN) Italy Tel. +39 0376 625300 Fax +39 0376 625279 E-mail: [email protected]