Sartorius PY-C12 4-cell conductivity electrode with integrated
Transcription
Sartorius PY-C12 4-cell conductivity electrode with integrated
98648-014-79 Sartorius PY-C12 4-cell conductivity electrode with integrated temperature compensation Applications Water, waste water, environmental, laboratory, fish farming, industrial water, boiler water, cooling water, acids, bases, swimming pools and most other applications where conductivity measurements are needed. Technical data 4-electrode measurements Cell constant 0.475 cm–1 (nominal) Temperature sensor integrated NTC 30 (30 kO/ 25°C) Weight 135 g (nominal) Materials Shaft Connection head Conductivity electrodes Thermistor enclosure Connection cable length Diameter Epoxy POM Graphite Graphite 1.0 m 6 mm Smallest allowed bend radius Permanent bend 80 mm One time or short time bend 50 mm Plug type socket 8 pins Measurement conditions Conductivity measuring range Temperature range Max. allowed overpressure Minimum depth of immersion Maximum depth of immersion Sensor shaft only 1 µS/cm … 0.3 S/cm –5 … 80°C (100°C) 2 + 105 Pa (2 bar) Operating position 36 mm Entire sensor + cable (up to 80°C) (= 120 mm / up to 100°C) any Storage conditions Recommended storing method Storage temperature in air 0 … 50°C Characteristic data on delivery Temperature responding t99 (99% of the final behavior value after) < 20 s Precision of the temperature sensor ± 0.2 K Frequent cleaning is recommended for lowrange conductivity measurements. After cleaning, thoroughly rinse with deionized water and recalibrate, if necessary. Under normal use the conductivity cell does not age. Certain applications and solutions like strong acids, highly alkaline media, organic solvents, very high temperature and other extreme environments may shorten the effective sensor life or damage the measurement cell. The warranty does not cover cases where extreme conditions cause failure or mechanical damage. Cleaning procedure Lime sediments may be removed by stirring the electrode in a 10% by volume acetic and water acid solution for 5 minutes. Oil or fat contamination may be removed with warm soapy water containing mild surfactants or detergents. Errors No temperature or conductivity display: – No connection between measuring instrument and sensor – Cable defective – Check connection between measuring instrument and sensor Questionable conductivity values: Incorrect calibration – recalibrate within expected range Measuring range exceeded – Contamination in the area of the electrodes; clean the electrode Electrodes damaged – Check / correct the calibration – Observe the application range – Clean the sensor (see section 2) Incorrect temperature display – The temperature sensor was not immersed deep enough in the measuring solution – Temperature sensor defective Note: Dispose of the conductivity cell as electronic waste. Sartorius PY-C12 4-polige Leitfähigkeitsmesszellen mit integrierter Temperaturkompensation Anwendungen Wasser, Abwasser, Umweltschutz, Labor, Fischzucht, Brauchwasser, Kesselwasser, Kühlwasser, Säuren, Basen, Schwimmbäder und auch die meisten anderen Anwendungen, in denen Leitfähigkeitsmessungen vorgenommen werden müssen. Technische Daten 4-Elektroden-Messungen Zellkonstante Integrierter Temperaturfühler Gewicht NTC 30 (30 kO/ 25°C) 135 g (nominal) Materialien Schaft Anschlusskopf Leitfähigkeitselektroden Thermistorschutzring Länge des Anschlusskabels Durchmesser Epoxy POM Graphit Graphit 1,0 m 6 mm 0,475 cm-1 (nominal) Kleinster zulässiger Biegeradius Dauerbiegung 80 mm Einmal- oder Kurzzeitbiegung 50 mm Steckverbinder 8-polig Messbedingungen Leitfähigkeitsmessbereich Temperaturbereich Max. zulässiger Überdruck Minimale Eintauchtiefe Maximale Eintauchtiefe Nur Sensorschaft Betriebslage 1 µS/cm … 0,3 S/cm –5 … 80°C (100°C) 2 + 105 Pa (2 bar) 36 mm Gesamter Sensor + Kabel (bis zu 80°C) (= 120 mm / bis zu 100°C) beliebig Aufbewahrungsbedingungen Empfohlene Aufbewahrung an Luft Lagerungstemperatur 0 … 50°C Kenndaten bei Auslieferung Temperaturansprechzeit: t99 (99% der Endwertanzeige nach) < 20 s Genauigkeit des Temperaturfühlers ± 0,2 K Reinigung Hinweis: Den Sensor vor der Reinigung vom Messgerät trennen! Cleaning Note: Disconnect the sensor from the instrument before cleaning Bei normalem Gebrauch altert die Leitfähigkeitsmesszelle nicht. Bestimmte Applikationen und Lösungen wie beispielsweise starke Säuren, stark alkalische Medien, organische Lösungsmittel, sehr hohe Temperaturen und andere extreme Umgebungsbedingungen können die Lebensdauer des Sensors jedoch verkürzen oder die Messzelle beschädigen. Die Gewährleistungsansprüche erstrecken sich nicht auf Fälle, in denen Funktionsstörungen oder mechanische Schäden durch extreme Anwendungsbedingungen verursacht wurden. Reinigungsverfahren Kalkablagerungen lassen sich durch 5-minütiges Rühren der Elektrode in einer 10%-igen wässrigen Essigsäurelösung (v/v) entfernen. Verunreinigungen durch Öle oder Fette können mit warmem Seifenwasser entfernt werden, das milde oberflächenaktive Substanzen oder ein mildes Reinigungsmittel enthält. Fehler und Fehlerbehebung Temperatur oder Leitfähigkeit wird nicht angezeigt: – Es besteht keine Verbindung zwischen Messinstrument und Sensor. – Das Kabel ist defekt. – Verbindung zwischen Messinstrument und Sensor prüfen. Die Leitfähigkeitsmesswerte sind nicht plausibel: Die Messzelle wurde falsch kalibriert. – Neukalibrierung im erwarteten Bereich Der Messbereich ist überschritten: – Bei Verschmutzung der Elektroden müssen die Elektroden gereinigt werden. Die Elektroden sind beschädigt: – Kalibrierung prüfen / korrigieren. – Anwendungsbereich beachten. – Sensor reinigen (siehe Abschnitt 2). Die Temperatur wird nicht korrekt anzeigt: – Der Temperaturfühler war nicht tief genug in die zu messende Lösung eingetaucht. – Der Temperaturfühler ist defekt. Hinweis: Entsorgen Sie die Leitfähigkeitsmesszelle wie Elektronikschrott. Sartorius AG Weender Landstrasse 94–108 37075 Goettingen, Germany In cases involving questions of interpretation, the German-language version shall prevail. Häufiges Reinigen wird bei Messungen im niedrigen Leitfähigkeitsbereich empfohlen. Nach der Reinigung gründlich mit deionisiertem Wasser spülen und bei Bedarf neu kalibrieren. Phone +49.551.308.0 Fax +49.551.308.3289 www.sartorius.com Specifications subject to change without notice. Printed and copyrighted by Sartorius · W500.05 · KT Publication No.: WPY6015-n06091 Im Auslegungsfall ist die deutsche Sprache maßgeblich. 98648-014-79 Sartorius PY-C12 Cellule de conductivité à 4 pôles avec compensation intégrée de la température Sartorius PY-C12 Electrodo de conductividad de 4 células con compensación de temperatura integrada Applications Eau, eaux usées, protection de l’environnement, laboratoire, pisciculture, eaux industrielles, eau de chaudière, eau de refroidissement, acides, bases, piscines et la plupart des autres applications au cours desquelles il faut effectuer des mesures de conductivité. Aplicaciones Agua, aguas residuales, en análisis del medio ambiente, en el laboratorio, en la piscicultura, aguas industriales, agua de caldera, agua de refrigeración, ácidos, bases, piscinas y muchas otras aplicaciones donde sea necesario medir la conductividad. Caractéristiques techniques Mesures à 4 électrodes Constante de cellule 0,475 cm–1 (nominal) Sonde de température intégrée NTC 30 (30 kO/ 25 °C) Poids 135 g (nominal) Matières Tige Extrémité de connexion Electrodes de conductivité Anneau de protection de la thermistance Longueur du câble de raccordement Diamètre Epoxy POM Graphite Graphite 1,0 m 6 mm Plus petit rayon de courbure autorisé Courbure permanente 80 mm Courbure unique ou de courte durée 50 mm Connecteur enfichable 8 broches Conditions de mesure Etendue de mesure de la conductivité Gamme de température Surpression max. autorisée Profondeur d’immersion minimum Profondeur d’immersion maximum Tige de l’électrode uniquement Position de fonctionnement Conditions de stockage Méthode de stockage recommandée Température de stockage 1 µS/cm … 0,3 S/cm –5 … 80 °C (100 °C) 2 + 105 Pa (2 bar) 36 mm Electrode entière + câble (jusqu’à 80 °C) (= 120 mm / jusqu’à 100 °C) au choix à l’air 0 ... 50 °C Données caractéristiques à la livraison Temps de réponse t99 (99 % de la valeur de la température finale après) < 20 s Précision de la sonde de température ± 0,2 K Nettoyage Remarque : Débrancher l’électrode de l’appareil avant de la nettoyer En cas de questions concernant l’interprétation, la version en langue allemande fera autorité. Un nettoyage fréquent est recommandé pour les mesures dans une gamme de conductivité faible. Après le nettoyage, rincer soigneusement l’électrode avec de l’eau déionisée et si nécessaire, effectuer un nouvel étalonnage. La cellule de conductivité a une longue durée de vie lorsqu’on l’utilise dans des conditions normales. Certaines applications et solutions telles que des acides forts, des substances extrêmement alcalines, des solvants organiques, des températures très élevées et d’autres conditions ambiantes extrêmes peuvent raccourcir la durée de vie effective de l’électrode ou endommager la cellule de mesure. La garantie ne couvre pas les cas où des conditions d’utilisation extrêmes provoquent des erreurs ou des dommages mécaniques. Procédure de nettoyage Pour enlever les dépôts calcaires, remuer l’électrode pendant 5 minutes dans une solution d’acide acétique et d’eau à 10%. Enlever l’huile ou la graisse avec de l’eau chaude savonneuse contenant des agents tensioactifs ou des détergents doux. Erreurs Pas d’affichage de la température ou de la conductivité : – Pas de connexion entre l’appareil de mesure et l’électrode – Câble défectueux – Vérifier la connexion entre l’appareil de mesure et l’électrode Valeurs de conductivité peu vraisemblables : Etalonnage incorrect – Etalonner à nouveau dans l’étendue escomptée Etendue de mesure dépassée – L’électrode est sale, nettoyer l’électrode Electrodes endommagées – Vérifier / corriger l’étalonnage – Respecter le domaine d’application – Nettoyer l’électrode (voir paragraphe 2) Affichage incorrect de la température – La sonde de température n’a pas été plongée assez profondément dans la solution de mesure – La sonde de température est défectueuse Remarque : Eliminer la cellule de conductivité en tant que déchet électronique. Datos técnicos Mediciones de 4 electrodos Constante de célula 0,475 cm–1 (nominal) Sensor de temperatura integrado NTC 30 (30 kO/ 25°C) Peso 135 g (nominal) Materiales Vástago Cabeza de conexión Electrodos de conductividad Recinto termistor Longitud cable de conexión Diámetro Epoxi POM grafito grafito 1,0 m 6 mm Radio del ángulo más pequeño permitido Ángulo permanente 80 mm Ángulo un vez o corto tiempo 50 mm Enchufe tipo Socket 8 clavijas Condiciones de medición Rango de medición conductividad 1 µS/cm … 0,3 S/cm Rango de temperatura –5 … 80°C (100°C) Sobrepresión máx. permitida 2 + 105 Pa (2 bar) Profundidad mínima de inmersión 36 mm Profundidad máxima Sensor completo + de inmersión cable (hasta 80°C) Vástago sensor sólo (= 120 mm / hasta 100°C) Posición de operación cualquiera Condiciones de almacenamiento Método de almacenamiento recomendado en aire Temperatura de almacenamiento 0 … 50°C Datos característicos a la entrega Tiempo de respuesta t99 (99% del valor a temperatura final después) < 20 s Precisión del sensor de temperatura ± 0,2 K Limpieza Nota: Desconectar el sensor del instrumento antes de la limpieza En caso de interpretación, la versión en lengua alemana será determinante. Se recomienda una limpieza frecuente para las mediciones de conductividad de bajo rango. Después de la limpieza, lavar meticulosamente con agua desionizada y recalibrar si es necesario. Bajo condiciones de uso normal, la celda de conductividad tiene una larga vida. Ciertas aplicaciones o soluciones tales como ácidos fuertes, medios altamente alcalinos, solventes orgánicos, temperaturas muy altas y otras condiciones ambientales difíciles pueden acortar la vida efectiva del sensor o dañar la célula de medición. La garantía no cubre los casos donde las condiciones extremas causen fallos o daños mecánicos. Procedimiento de limpieza Los sedimentos de cal pueden eliminarse agitando el electrodo en una solución en volumen de ácido acético y agua al 10% durante 5 minutos. La contaminación por aceite o grasa puede eliminarse con agua jabonosa caliente que contenga tensoactivos o detergentes suaves. Errores No hay indicaciones de temperatura o conductividad: – No hay conexión entre el instrumento de medición y el sensor – Cable defectuoso – Controlar la conexión entre el instrumento de medición y el sensor Valores de conductividad cuestionables: Calibración incorrecta – Recalibrar dentro del rango esperado Rango de medición sobrepasado – Contaminación en el área del electrodo, limpiar el electrodo Electrodos dañados – Controlar / corregir la calibración – Observar el rango de aplicación – Limpiar el sensor (ver sección 2). Indicación de temperatura errónea – El sensor de temperatura no está sumergido suficientemente en la solución a medir – Sensor de temperatura defectuoso Nota: Eliminar la célula de conductividad como desecho electrónico.