Manual

Transcription

Manual
PRO ACID System
USER GUIDE
Service / Site
Référence
Version
Date version
Page
: QUAL / France
: 0016
: V.04.0
: 07/07/2014
: 1/9
Pro ACID System - Installation
GB
140
75
Filter gasket
A
3 wall plugs S7
3 S/st screws 5,5x38
E
244
Water pressure
2 to 6 bars
B
WATER
1700
Fiber gasket
Quick coupler
D
C
F
IMPORTANT
! Ajuster
IMPORTANT
! la
longueur du tuyau
Adjust thepour
lenght
d’aspiration
queof
la
hosecrépine
to the yellow
repose filter
verticalement
sur le
that
rest upright
onfond
the
du
bidon
bottom
2 wall plugs S7
2 S/st screws 5,5x38
2 rondelles L6 inox.
Les
cotes installation
d’installation (endimensions
mm) sont données
titre indicatif
These
are àindicative
FILTER
MONTAGE
GASKET
DU
JOINT
ASSEMBLY
FILTRE
A
FIBER
MONTAGE
GASKET
DU
JOINT
ASSEMBLY
FIBRE
Outillage
Needednécessaire
tools : 1 drill
: 1 forêt
Ø 7mm
Ø 7mm
and 1etscrew
1 tournevis
driver cruciforme
cruciform
DILUTION
DESTIP
BUSES
MONTAGE
BLUE RING
DU COUPLEUR
QUICK COUPLER
RAPIDE A MONTAGE
DE
ASSEMBLY
DILUTION
BAGUE
ASSEMBLY
BLEUE
C
B
150
OPTION
S/st can
holder. (5L)
500
© All rights reserved
160
Fiber
gasket
Adaptator
Coupler
Coupler
Blue ring
Hose insertion
Clamping ring
IMPORTANT !
Respect the
gasket
orientation
D
WAND ASSEMBLY
E
Check
valve
Tip
PERÇAGE
HOLE OF THE
DES
BOUCHONS
TAPE
F
Handle
Nut + gasket
Wand
1 trou Ø10mm
Hose
PACKING LIST OF THE PULV ACIDE SYSTEM
1_PULV ACIDE Sy stem (PVC)
1_Bag w ith connection kit =
1_Suction line (cry stal hose) L:2,5m
1_Inlet hose of w ater (L: 2m) Ø12/19mm
1_Yellow filter w ith w eight.
1_Ø12/19mm Discharge hose, 10, 15 or 25m according to model
1_Bag of 15 tips
1_Stainless steel lance no-scratch L: 60 or 120cm according to model
1_Nipple for quick coupler M-F3/4"
1_Instruction sheet
1_Quick coupler ring blue
1_Quick coupler ring red
1_Bag w ith screw s and gaskets1 Rubber gasket blue 3/4"
1_Green fiber gasket 3/4"
3 S/st screw s. Ø5,5x 37
3 w all plugs S7
NTPUASLB V.04.0 p.6/9
Pro ACID System - Use
GB
A
Water pressure 2 to 6
bars
Maximum temperature
working= 20°C
CLOSE
B
OPEN
Safety rules S36/37/39
Wear protection coat
Wear protection gloves
© All rights reserved
Wear protection glasses
and mask
CAUTION
ALWAYS orientate spray in direction of surfaces to treat.
NEVER orientate spray in direction of people, animals or plants
USE
1° Open the valve inlet water « A »
2° Press the lever « B » handle spraying.
3° Wait a few seconds the rise of production in
the suction line.
4° Close the inlet vale « A » after use.
ALWAYS w ait few seconds for a good product and w ater mix ing.
ALWAYS close w ater inlet v alv e after each use.
WATER PRESSURE must be included on 2 bar to 6 bar.
MAXIMUM w orking temperature is 50°C
ALWAYS keep the unit on frost protection
METHOD OF DILUTION CALCUL
TABLEAU DE DILUTION PULV ACIDE
Couleur
Produit
Couleur
Produit
Pink
0,5%
Blue
9,4%
Purple
1,3%
White
10,4%
Turquoise
1,5%
Red
12,6%
Dark brow n
2,2%
Beige
15,3%
Yellow
2,6%
Black
16,4%
Orange
3,8%
Grey
16,6%
Green
5,8%
Without tip
17,0%
Light brow n
7%
Incolore
Bouchon
This table is done to
help you to choose a
tip according to
expected
concentration
EXEMPLE: 15 (A) x 100%= 1.5%
1000 (B)
(This drawing is an exemple)
Volume B
(1000 cl ou 10 000 ml)
Volume A
(15 cl ou 150 ml)
CONDITIONS DES TESTS
Dynamic water pressure = 2,5 bars
25m hose
60cm et 120 cm wand
Volume A : breathed product
Volume B : solution (water + breathed product)
NTPUASLB V.04.0 p.7/9
Pro ACID - Troubles
GB
Water pressure 2 bars to
6 bars
© All rights reserved
Maximum temperature
working: 20°C
Check valve cleaning
Spring
MAINTENANCE
? PULV ACIDE system does not aspire product.
1° Check the pressure of the water system (minimum : 2 bar, max : 6 bar)
2° Check that the filter gasket is not dirty or scaled. (clean or replace)
3° Check that the yellow filter of the suction line is submerged in the
product, and the hose is not pinched, folded, or closed.
4° Verify that the tip is not clogged. (clean or replace)
5° Check that the yellow filter of the suction line is not dirty. (clean or
replace)
6° Check that the spray handle is not dirty or calcified. (clean or
replace)
7° Check that the flat spray nozzle is not dirty or calcified. (clean or
replace)
? The product can filled with water..
8° Verify that the check valve is not dirty or calcified. (clean or replace)
Ceramical O ring
ball
Spray nozzle cleaning
Nut of lance
Gasket
Flat spray nozzle
Nozzle holder
NTPUASLB V.04.0 p.8/9
Pro ACID- Description
GB
1
3
2
19
Water pressure
2 bars to 6 bars
16
WATER
4
5
9
7
10
6
8
11
18
12
13
14
17
Safety rules S36/37/39
15
Wear protection coat
© All rights reserved
20
Wear protection gloves
Wear protection glasses
and mask
PULV ACIDE system is intended for the determination and application of shampoo for automobile
bodies.
ACCESSORIES AND SPARE PARTS PULV ACIDE
Designation
Repère
Back plate PULV ACIDE - White PVC
Personnal logo
Hose connection Ø12/19 - Lg 2m - Green
Fiber gasket 3/4" black (bag of 10)
Nipple for quick coupler 3/4"
Brass quick coupler blue
Stop vlave
Venturi assembly PVDF
Dilution tips (bag of 15)
Check valve White/Yellow (gasket FPM)
S/st screw M5x45 (x2)
Hose blocker (PVDF)
Hose connection nut
Suction line Lg: 2m (Cristal hose Ø 6/9)
Yellow filter with weight
Spray handle with quick coupler
PVC wand no-scratch. Lg: 60 or 120 cm (depend of version)
Blue discharge hose Ø12/19 PVC. 10,15, or 25m (depend of version)
Filter gasket 3/4" black (bag of 5)
Spray nozzle (60° - 9,8L/mn)
spray nozzle holder
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
20
NTPUASLB V.04.0 p.9/9