Energy is free. Just take it ! SOLAR AIR CONDITIONER WITH DC MOTOR Series : OFF-GRID SOLUTIONS The Solar Air Conditioner proposed by Sud Concept has been specifically conceived for OffGrid applications. The air conditioner is directly fed by a group of batteries charged by a solar field. The main characteristic of this Solar Air Conditioner is to be powered by one DC motor which is one unique feature developed by Sud Concept for this kind of applications. Thanks to this solution no inverter is required with the advantage of higher performance and reliability of integrated solution. This Solar Air Conditioner is suitable in all applications where electrical connection to network is too expensive or in stand-alone uses where air conditioning is required for functional purposes (electrical cabinets, TLC shelters, small offices, database centers, etc.) L’énergie gratuite, Profitez-en ! CLIMATISEUR SOLAIRE AVEC MOTEUR DC Série : SOLUTIONS POUR SITES ISOLES Le climatiseur solaire proposé par la société Sud Concept a été spécialement conçu pour les applications en sites isolés. Ce climatiseur solaire est alimenté directement à partir de batteries électriques chargées par un champ photovoltaïque. La principale innovation du climatiseur solaire développé par Sud Concept réside dans son alimentation en Courant Continu. Grace à cette caractéristique, le système ne nécessite pas d’onduleur, ce qui a pour avantages d’améliorer son efficacité et sa fiabilité. Le Climatiseur Solaire est particulièrement conseillé lorsque la connexion au réseau électrique est impossible à réaliser ou trop coûteuse et que l’ajout d’un air conditionné est recommandé. (cabines électriques, shelters pour Telecom, petits bureaux, centres de données, etc.). Sud Concept - ZI de Chalançon N. 2 – Allée Alfred Nobel – 84270 Vedène – France Tel. +33 04 90 83 63 29 – e-mail [email protected] The solar Air Conditioner is currently available in one version providing 15,000 BTU/hr during cooling and 20,500 BTU/hr during heating. This Solar Air Conditioner is proposed as standalone unit or fully integrated with solar modules, charge regulator and batteries. The specific application will be studied by Sud Concept taking into account the environmental conditions as well as Customer’s requirements. This Solar Air Conditioner provides the best performances when working with pure DC power supply 48V +/- 1%. As alternative it can be fed by industrial or Telecom DC power source. In this second case the Voltage shall be kept in a range 42V – 60V. Voltages below and beyond such limits may affect the performance and life of system. In case of pure DC supply, in order to protect the battery during the discharge, the Solar Air Conditioner is provided of smart control which cutoff automatically when the Voltage is below the threshold of 42VDC. Then the conditioner restores automatically conditioner when the Voltage is back higher than 46 VDC. Le Climatiseur Solaire est disponible dans une version donnant 15.000 BTU/h en refroidissement et 20.500 BTU/h en chauffage. Le Climatiseur Solaire est proposé seul ou en kit avec les modules solaires, les régulateurs de charge et les batteries. Sud Concept réalisera une étude spécifique prenant en compte les conditions extérieures et les exigences du Client. Le Climatiseur Solaire donne ses meilleures performances lorsqu’il est alimenté par une source de tension DC propre de 48V +/- 1%. Il est toutefois possible d’utiliser des sources DC industrielles ou Telecoms. Dans ce cas, la tension doit être comprise entre 42VDC et 60VDC. Des tensions plus élevées ou plus basses peuvent limiter les performances et la durée vie du climatiseur. Lorsque le climatiseur est alimenté par une source de tension DC propre (par exemple à partir de batteries), un système intelligent coupe l’alimentation quand la tension est plus basse que 42VDC. L’alimentation est ensuite automatiquement réactivée lorsque la tension est supérieure à 46VDC. Supply from industrial or Telecom DC source Alimentation par source DC industrielle ou Telecom Supply from pure DC source. Cut-off (42VDC) and Cut-in (46VDC. - Alimentation par source DC pure. Cut-off (42VDC) et Cut-in (46VDC). Operating Range / Plage de température de fonctionnement Cooling – Refroidissement Heating - Chauffage Max 32°C D.B. / 23°C W.B. 43°C D.B. / 26°C W.B. Min 21°C D.B. / 15°C W.B 21°C D.B. / 15°C W.B Max 27°C D.B. / 18°C W.B 24°C D.B. / 18°C W.B Min 20°C D.B. / 15°C W.B -7°C D.B. / -8°C W.B D.B. : Dry Bulb / Air sec – W.B. : Wet Bulb / Air humide Sud Concept - ZI de Chalançon N. 2 – Allée Alfred Nobel – 84270 Vedène – France Tel. +33 04 90 83 63 29 – e-mail [email protected] TECHNICAL CHARACTERISTICS / CARACTERISTIQUES TECHNIQUES Function / Fonction Cooling / Refroidissement Power Supply / Alimentation Power / Puissance Capacity / Capacité 48 VDC 4000 W 4500 W - - 800 m3/h 850 m3/h Rated current / Courant 28,5 A 29.0 A Max Current / Courant max 37,5 A 37,5 A Rated input power / Puissance 1368 W 1392 W Max Power / Puissance max 1900 W 1900 W Dehumidification / Déshumidification Air Flow / Débit d’air Electrica data / Données éléctriques Heating / Chauffage Indoor Unit /Unité intérieure 106 x 37 x 27 cm (L x W x H) Outdoor unit / Unité extérieure 31 x 37 x 102 cm (L x W x H) Size / Dimensions Indoor Unit /Unité intérieure 12 kg Outdoor unit / Unité extérieure 52 kg Refrigerant / Réfrigérant R410A Refrigerant filling capacity / capacité du réfrigérant 1,28 kg Indoor unit sound level / Niveau sonore de l’unité intérieure 45 dBA outdoor unit sound level / Niveau sonore de l’unité extérieure 47 dBA Wight / Poids Special remarks / autres informations Sud Concept - ZI de Chalançon N. 2 – Allée Alfred Nobel – 84270 Vedène – France Tel. +33 04 90 83 63 29 – e-mail [email protected] EXAMPLES OF CONFIGURATION EXEMPLE DE CONFIGURATIONS The solar air conditioner shall be installed in combination with a PV system which has the task to produce electricity and then to store it in batteries. This energy will be used by the conditioner to cool or heat the rooms. Below there are three examples given to the user as reference only. In any case it is suggestible to carry out a detailed study of energy consumption versus energy production in order to give to the photovoltaic system the suitable capacity for the good operation of the Air conditioner. Pour son fonctionnement le climatiseur solaire sera installé avec un système photovoltaïque en amont qui produit l’électricité. Cette électricité est ensuite emmagasinée dans un parc de batteries. L’énergie stockée dans les batteries sera ensuite utilisé par le climatiseur pour refroidir ou chauffer. De suite sont donnés trois exemples pour l’utilisateur uniquement en tant que référence. Il est en tout cas nécessaire faire un étude détaillé de la consommation électrique par rapport à la production d’énergie du système photovoltaïque pour lui donner la bonne taille et assurer le fonctionnement convenu au climatiseur. EUROPE, AFRIQUE, AMERIQUE CENTRALE, AMERIQUE LATINE EUROPE, AFRICA, NORTH AMERCIA, SOUTH AMERICA Inclinaison : 2° à 45° Orientation : plein sud Irradiation moyenne annuel : 1 à 6kWh/m² Minimum 3 panneaux en séries Puissance nominale : 1776 W Solar Air Fonctionnement la journée : 33% par Conditioner/ heure donc (20min/heure) Climatisateur Fonctionnement la nuit : 25% par heure Solaire donc (15min/heure) PV system / Système PV Exemple N.1 Exemple N. 2 Exemple N. 3 Inclination: 2° - 45° Orientation : South Average Annual Irradiation: 1 à 6kWh/m² Minimu 3 modules in series Nominal power : 1776 W Daily working time: 33% per hour or 20min/hour Night working time : 25% per hour or 15min/hour 5 heures d’utilisation quotidienne + aucune utilisation de nuit 5 hours of daily working time and no night operation - 690 W de panneaux photovoltaïques - 1 Régulateur 60A - 8 batteries 200Ah – 12V AGM ou GEL - 1 Tableau de protection DC - 690 W of solar modules - 1 60A charger - 8 batteries 200Ah - 12V (AGM or GEL) - 1 DC protecting box 6heures d’utilisation quotidienne+ 4 heures utilisation de nuit 6 hours of daily working time and 4 Hours per night - 1380 W de panneaux photovoltaïques - 1 Régulateur 60A - 16 batteries 200Ah 12V AGM ou GEL - 1 Tableau de protection DC - 1380 W of solar modules - 1 60A charger - 16 batteries 200Ah - 12V (AGM or GEL) - 1 DC protecting box 8 heures d’utilisation quotidienne+ aucune utilisation de nuit 8 hours of daily working time and no night operation - 2300 W de panneaux photovoltaïques - 1 Régulateur 80A - 16 batteries 200Ah – 12V AGM ou GEL - 1 Tableau de protection DC - 2300 W of solar modules - 1 80A charger - 16 batteries 200Ah - 12V (AGM or GEL) - 1 DC protecting box Other configurations available – Autres configurations sont disponibles Sud Concept - ZI de Chalançon N. 2 – Allée Alfred Nobel – 84270 Vedène – France Tel. +33 04 90 83 63 29 – e-mail [email protected] Notice: Dimensions, data and photos are not binding and can be modified without prior notice. Notice : Dimensions, données et photos ne sont pas contractuels et peuvent être modifié sans préavis. Distributor / Distributeur Sud Concept - ZI de Chalançon N. 2 – Allée Alfred Nobel – 84270 Vedène – France Tel. +33 04 90 83 63 29 – e-mail [email protected]