Evolve™ by GE Outdoor LED Fixtures
Transcription
Evolve™ by GE Outdoor LED Fixtures
Evolve™ by GE Outdoor LED Fixtures The GE Advantage™ Each EvolveTM by GE LED fixture comes complete with GE service and support, every step of the way. 1 Discovery & Design You receive a comprehensive, custom lighting solution from a team who truly listens to understand your specific goals. 2 Innovative Systems You can choose from a broad portfolio, including the latest lighting technologies. 3 Seamless Distribution You have easy and immediate access through our national network of distributors. 4 Integration Services You garner coordination services with a network of installers for your existing infrastructure or new construction projects. 5 ROI Optimization You see attractive financial benefits with a plan built to deliver – we even assist with utility rebate capture and propose financing options from GE Capital. MAKING MORE HISTORY The EvolveTM by GE family of products is one of the most awarded in GE history. Honors include the highly coveted Best-in-Class award, in two consecutive years, from the Next Generation Luminaires™ (NGL) Solid-State Lighting Design Competition, the LIGHTFAIR® International innovation award, and the Architectural SSL Product Innovation Award (PIA). Our heritage and expertise burns bright in Evolve™ by GE. Over 100 years ago, GE lit the first streetlight. Fifty years later, a GE scientist created the first visible LED. Today, we offer the best of both worlds in our multi-award winning Evolve™ by GE LED fixtures – a family of roadway, street and outdoor LED lighting fixtures that’s taking “next generation” to a whole new level. Reimagining the landscape of outdoor lighting. Outdoor lighting is absolutely crucial to the security of our streets and public places. And today, it has a lot to live up to: new legislation, environmental challenges, requirements in energy reduction – just to name a few. Nobody has more experience in outdoor lighting than GE. For more than a century, we’ve been imagining better for our roadways, parking lots, garages, residences and commercial areas. Better energy efficiency. Better aesthetics. Less maintenance. You get it all with EvolveTM by GE. 4 | Evolve™ by GE Outdoor LED Fixtures |5 Building better solutions in Hendersonville. Get what you want faster with responsive services. We’ve all heard it before: You can have it fast, or you can have it right. At GE Lighting, we want our customers to have both. That’s why we’ve integrated the highest standards of quality testing into our engineering process. And it’s why we’ve transformed our Hendersonville, North Carolina, plant into a short-cycle manufacturing center. Now, we can move from order placement to product shipping in as little as 10 days. Combine this with our comprehensive distribution and installation network, and you’ll have your custom outdoor solutions up, running and generating savings faster than ever before. The complete package. One provider. When you choose GE, you’ll enjoy the benefits of working with a single supplier for your full outdoor LED lighting system. In addition to convenience, you can be sure all parts and pieces were designed to work together for the highest performance. 6 | Evolve™ by GE Outdoor LED Fixtures |7 Evolve by GE LED fixtures. Imagination runs in the family. TM From roadways to parking lots, residential to retail, commercial properties to public places, you’ll find your ideal lighting solution in the EvolveTM by GE portfolio. Efficiency and reliability come standard in each fixture, and that’s just the beginning. 8 | Evolve™ by GE Outdoor LED Fixtures Long life span Reduced glare EvolveTM by GE LED fixtures offer a 50,000-hour life rating, equaling more than 11 years of service life based on 12 hours of operation per day. Revolutionary designs produce safer, non-pixelated light with low glare. Minimal maintenance Outstanding performance – no matter the weather Longer life span means less time switching out lamps. Couple that with easier installation and more reliable engineering, and your maintenance time is virtually eliminated. Evolve by GE LED fixtures are built to endure extreme weather hazards and conditions. And, unlike other outdoor options, these fixtures perform even better in the cold. Environmental responsibility In addition to the built-in efficiency benefits of LEDs, all Evolve by GE LED fixtures are mercury- and lead-free. |9 Evolve™ by GE LED Roadway Lights Combining the science of light and a historical knowledge of roadway fixtures, GE engineers have developed groundbreaking roadway lighting solutions that are changing the way we light our lanes. Advanced optical designs offer hundreds of photometric options to meet your precise lighting requirements, while delivering the built-in benefits of all EvolveTM by GE LED fixtures and more. Maximized efficient utilization of light (CU) means less wasted light and more saved energy. Low Wattage Streetlight (ERL) The ideal LED solution for basic local and collector roadway needs. Scalable Project Grade Cobrahead (ERS1 & ERS2) For local to major roadways, combine the aesthetic of traditional roadway fixtures, the technical capabilities of a sophisticated LED system, and the functional demands of extreme weather hazards. Increased control with stand-alone or wireless control system options. Simplified installation and maintenance with easy-access doors for replacements or repairs, and tool-less or single-tool entry for quicker connects. More consistent light distribution through a revolutionary optic design that focuses light on the road, not in the eyes of drivers. Optimized thermal management due to a robust heat sink design, resulting in longer life, reduced lumen depreciation and exceptional performance. Scalable Specification Grade Cobrahead (ERS1, ERS2, ERS3 & ERS4) With hundreds of photometric options and lumen ranges from 2,400 to 25,400, expect exceptionally controlled light for any roadway. Evolve LED Security Light (E2SA) An energy-efficient, robust fixture designed for outdoor work yards, roadside commercial establishments, suburban developments and rural areas. C A S E I N P O I N T. The city of Oakland, California, achieved 40% savings (over $1.4 million annually) in energy and maintenance costs with Evolve by GE Scalable Cobrahead fixtures. 10 | Evolve™ by GE Outdoor LED Fixtures Evolve™ by GE LED Decorative Post Tops For downtown spaces, commercial developments and residential communities, you’ll find EvolveTM by GE LED Decorative Post Tops that offer more than their striking good looks. In addition to improved horizontal and vertical uniformity, you can say goodbye to the shadow circles commonly seen beneath other LED post top fixtures. And compared to HID, Evolve by GE LED Decorative Post Tops can significantly reduce system energy. Avery™ StreetDreams™ (EPAS) Classic nostalgia Salem (EPST) Traditional utility carriage Contemporary Twin Support (EPTC) Distinct, trim styling | 11 Evolve™ by GE LED Area Lights EvolveTM by GE LED Area Lights provide reduced offsite visibility, as well as effective security light levels with symmetric and asymmetric distributions. They can yield a significant reduction in system energy compared with standard HID systems and virtually eliminate ongoing maintenance expenses. Scalable Area Light (EAS) Offers greater flexibility, style and scalability for applications like commercial and medical properties, strip malls and large malls, and small, large and big box retailers. N Series Area Light (EAN) Delivers superior site uniformity and vertical light distribution with mounting options for both square and round poles. Matching Wall Pack and Flood Light make it a cinch to match the look of parking lots, building façades, walkways and other areas. Scalable Wall Pack (EWS) A scalable solution for wall-mounted site, area and general lighting applications. Can reduce energy consumption considerably compared to standard HID systems. N Series Wall Pack (EWN) Designed to efficiently illuminate walkways and general areas; balances need for scalability with workhorse performance. 12 | Evolve™ by GE Outdoor LED Fixtures Evolve™ by GE LED Canopy Lights Built to meet technical, functional and weather demands, EvolveTM Canopy Lights are an ideal solution for canopy installations (such as gas stations), or drive-thrus. The sleek new ECB fixture offers quick and easy installation – just four screws. ECB ECR Evolve by GE LED Parking Garage Lights Enjoy significant energy and maintenance reduction, effective security light levels, increased control and the instant-on capabilities needed to make the most of parking areas. Our unique light-up version eliminates the “cave effect” for a safer, more driver-friendly installation. EGMS EG2R Evolve by GE LED Flood Lights Flood Light (EFN) Four mounting options fit virtually any flood application, including architectural wall washing and façade lighting, sports court area lighting, flagpoles and bulletin/billboard lighting. A unique photoelectric sensor receptacle can minimize control requirements in dusk-to-dawn applications. | 13 Reimagine your outdoor lighting in three easy steps. Lightin g Audit 1. Request your FREE Lighting Audit from GE. 2. Receive your customized lighting solution. 3. Let GE coordinate the rest. Backed by the GE Advantage , we will work with you to: TM Learn how to save energy and cut spending Support environmental initiatives To learn more about municipal lighting solutions from GE or schedule your complimentary Lighting Audit, visit gelighting.com/evolve. Realize a positive return on investment Stars belong outside. And that’s just where you’ll find EvolveTM by GE LED fixtures. From roadways to residential neighborhoods, parking lots to public spaces, Evolve by GE outdoor LED lighting fixtures are redefining the limits of high-quality, low-maintenance, energy-efficient illumination. Welcome to the next evolution of outdoor lighting. Get ready to shine. For more information or to get started, contact your GE Lighting sales representative or visit gelighting.com/evolve. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end-use conditions. Evolve™ is a registered trademark of GE. ©2015 GE. © 2015 GE OLP3077 08/2015 Printed in USA GE Lighting Evolve LED Area Light ™ Scalable Area Light (EASC) imagination at work Product Features The next evolution of the GE Evolve™ LED Area Light continues to deliver outstanding features, while adding greater flexibility, style and scalability. This latest design offers higher lumen outputs and provides photometric combinations with high efficacy, providing the ability to meet even a wider range of area lighting needs. Additionally, the new EASC Evolve Luminaire comes with a specially designed auto dealership optic for exceptional illuminance on the dealership’s front row. Optional programmable motion sensing for Title 24 compliance is available. Applications Mounting • Site, area, and general lighting applications utilizing advanced LED optical system providing high uniformity, excellent vertical light distribution, reduced offsite visibility, reduced on-site glare and effective security light levels. • Ideal for small to large retailers, commercial to medical properties, and big box retailers. Option A • 10-inch (254mm) mounting arm for square pole prewired with 24-inch (610mm) leads. Option B • 10-inch (254mm) mounting arm for round pole prewired with 24-inch (610mm) leads. Option C • Slipfitter mounting for 2 3/8-inch (60mm) O.D. pipe prewired with 24-inch (610mm) leads. Option D • 10-inch (254mm) mounting arm for round or square pole prewired with 24-inch (610mm) leads. Option S • Knuckle Slipfitter mounting for 2.3-3” O.D. pipe, pre-wired with 24-inch (610mm) leads. Housing • Die-cast aluminum housing. • Slim architectural design incorporates an integral heat sink and light engine, ensuring maximum heat transfer, long LED life, and a reduced Effective Projected Area (EPA). • Meets 3G vibration standards per ANSI C136.31-2010. LED & Optical Assembly Finish • Structured LED arrays for optimized area light photometric distribution. • Evolve light engine with directional reflectors designed to optimize application efficiency and minimize glare. • Utilizes high brightness LEDs, 70 CRI at 4000K and 5000K typical. • • • Lumen Maintenance • 120-277 volt and 347-480 volt available. • System power factor is >90% and THD <20%.* • Class “A” sound rating. • Photo electric sensors (PE) available for all voltages. • ANSI C136.41 dimmable PE receptacle is available making the unit “adaptive controls ready.” • Surge Protection Options: For 120-277VAC and 347-480VAC per IEEE/ANSI C136.2-2015. – 6kV/3kA “Basic” surge protection, standard. – 10kV/5kA “Enhanced” surge protection available with R option. Lumen Maintenance (25°C Ambient) Optical Code L5, V5, L4, L3, L2 LA All others Calculated 50,000 hr 100,000 hr 0.98 0.90 0.99 Calculated Hours L90 L70 0.95>100,000 >100,000 0.81>100,000 49,000 0.97>100,000 >100,000 Lumen Maintenance per IES TM-21. Ratings • listed, suitable for wet locations. • listed with option code “J” SKUs. • IP65 rated optical enclosure per ANSI C136.25-2009. • Temperature rated at –40° to 50°C (–40° to 35°C for fixtures over 390 watts). • Upward Light Output Ratio (ULOR) = 0. • Title 24 compliant with “H” motion sensor option. • Compliant with the material restriction requirements of RoHS. Corrosion resistant polyester powder painted, minimum 2.0 mil. thickness. Standard colors: Black & Dark Bronze. RAL & custom colors available. Electrical * System power factor and THD is tested and specified at 120V input and maximum load conditions. Ordering Number Logic Evolve™ LED Scalable Area Light (EASC) E _ _A _S C _ _ PROD. ID PHOTOMETRIC VOLTAGE _ OPTICAL DISTRIBUTION ORIENTATION CODE E= Evolve C= Photometric 0 = 120 - 277 Series 1 = 120* A= Area 2 = 208* 3 = 240* S= Scalable 4 = 277* 5 = 480* D = 347* H = 347-480 F = Front L = Left R = Right N = Not Applicable _ __ DRIVE CURRENT LED COLOR TEMP 5 = 525mA 40 = 4000K 7 = 700mA* 50 = 5000K * Only select for product 395W or greater. Light pattern thrown in direction specified in relation to Pole and Fixture. *Specify single voltage if fuse option is selected. Pole Front (F) Pole Left (L) TYPE V TYPE IV TYPE III TYPE II OPTICAL CODE TYPE D5 E5 F5 G5 H5 J5 K5 L5 N5 P5 Q5 R5 S5 T5 U5 V5 A4 B4 C4 D4 E4 F4 G4 H4 J4 K4 L4 A3 B3 C3 D3 E3 F3 G3 H3 J3 K3 L3 A2 B2 C2 D2 E2 F2 G2 H2 J2 K2 L2 KA LA Symmetric Medium Symmetric Medium Symmetric Medium Symmetric Medium Symmetric Medium Symmetric Medium Symmetric Medium Symmetric Medium Symmetric Short Symmetric Short Symmetric Short Symmetric Short Symmetric Short Symmetric Short Symmetric Short Symmetric Short Asymmetric Forward Asymmetric Forward Asymmetric Forward Asymmetric Forward Asymmetric Forward Asymmetric Forward Asymmetric Forward Asymmetric Forward Asymmetric Forward Asymmetric Forward Asymmetric Forward Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Narrow Asymmetric Narrow Asymmetric Narrow Asymmetric Narrow Asymmetric Narrow Asymmetric Narrow Asymmetric Narrow Asymmetric Narrow Asymmetric Narrow Asymmetric Narrow Asymmetric Narrow Asymmetric 100° Wide Auto Asymmetric 100° Wide Auto Not Applicable (N) TYPICAL INITIAL LUMENS TYPICAL SYSTEM WATTAGE 4000K & 5000K 120-277V & 347-480V 8300 12700 15000 17100 21200 25200 30000 38000 9200 13800 16400 18700 23100 27400 33000 41500 4200 6500 7600 8700 12900 15400 17100 21200 25200 30000 38300 4700 7100 8300 9500 13900 16800 18700 23100 27400 33000 41500 4600 6800 8000 9100 13400 16200 18000 22300 26500 31900 40000 35400 46900 PE FUNCTION _ ____ ___ MOUNTING ARM COLOR OPTIONS BLCK = Black A=10” Arm for DKBZ = Dark Bronze Square Pole supplied with leads GRAY = Gray WHTE= White B = 10” Arm for Round Pole supplied with leads Contact manufacturer for other colors. C = EXT Slip-fitter 2” Pipe (2.378 in. OD) supplied with leads D = 10” Arm for round or square poles, supplied with leads and additional hardware S = Knuckle Slipfitter ** PE control not for 2.3 in. - 3.0 in. OD available for 347-480V. Tenon, supplied with Must be a discrete voltage (347V or 480V). leads. 0-45° vertical † When ordering PE aiming angles function socket A-D, achievable. 1= None 2= PE Rec. 4 = PE Rec. with Shorting Cap 5 = PE Rec. with Control ** A = ANSI C136.41 7-pin dimming PE Receptacle †# D = ANSI C136.41 7-pin dimming PE Receptacle with Shorting Cap †# a dimming driver must also be ordered under the “OPTIONS” column. # Order Dimming/Control PE as a separate item. Pole Pole Right (R) _ DISTRIBUTION ORIENTATION AVAILABLE 82 119 137 156 199 235 283 395 82 119 137 156 199 235 283 395 44 62 72 82 119 144 156 199 235 283 395 44 62 72 82 119 144 156 199 235 283 395 44 62 72 82 119 144 156 199 235 283 395 283 398 *Rating values for B and G are based on rated lumens and may vary due to flux tolerances. N N N N N N N N N N N N N N N N F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R F, L, R C = IEC D =Dimming (0-10 Volt Input) † F =Fusing H = Motion Sensor **# J = cUL/Canada R = 10kV Extra Surge Protection XXX = Special Options † Dimming leads will be provided through the back of the arm, unless specified with A or D PE Function. ** When ordering Motion Sensing Option H - “A” or “B” Mounting Arm must be selected. Fixture power increase of 1W expected with sensor use. # Dimming is standard with H option code. Do not also select D option. Not compatible with PE receptacle options A, or D. BUG RATING* 4000K & 5000K IES FILE NUMBER B U G 4000K 3 4 4 4 4 5 5 5 3 3 4 4 4 4 5 5 1 1 1 1 2 2 2 3 3 3 3 1 1 1 2 2 2 2 3 3 3 3 1 1 2 2 2 3 3 3 3 3 4 4 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 2 2 2 2 3 3 4 1 2 2 2 2 2 2 3 1 2 2 2 3 3 3 4 4 5 5 1 1 2 2 2 2 2 3 3 4 4 1 1 2 2 2 3 3 3 3 4 4 3 4 EASC_D5N540______.IES EASC_E5N540______.IES EASC_F5N540______.IES EASC_G5N540______.IES EASC_H5N540______.IES EASC_J5N540______.IES EASC_K5N540______.IES EASC_L5N740______.IES EASC_N5N540______.IES EASC_P5N540______.IES EASC_Q5N540______.IES EASC_R5N540______.IES EASC_S5N540______.IES EASC_T5N540______.IES EASC_U5N540______.IES EASC_V5N740______.IES EASC_A4F540______.IES EASC_B4F540______.IES EASC_C4F540______.IES EASC_D4F540______.IES EASC_E4F540______.IES EASC_F4F540______.IES EASC_G4F540______.IES EASC_H4F540______.IES EASC_J4F540______.IES EASC_K4F540______.IES EASC_L4F740______.IES EASC_A3F540______.IES EASC_B3F540______.IES EASC_C3F540______.IES EASC_D3F540______.IES EASC_E3F540______.IES EASC_F3F540______.IES EASC_G3F540______.IES EASC_H3F540______.IES EASC_J3F540______.IES EASC_K3F540______.IES EASC_L3F740______.IES EASC_A2F540______.IES EASC_B2F540______.IES EASC_C2F540______.IES EASC_D2F540______.IES EASC_E2F540______.IES EASC_F2F540______.IES EASC_G2F540______.IES EASC_H2F540______.IES EASC_J2F540______.IES EASC_K2F540______.IES EASC_L2F740______.IES EASC_KAF540______.IES EASC_LAF740______.IES 5000K EASC_D5N550______.IES EASC_E5N550______.IES EASC_F5N550______.IES EASC_G5N550______.IES EASC_H5N550______.IES EASC_J5N550______.IES EASC_K5N550______.IES EASC_L5N750______.IES EASC_N5N550______.IES EASC_P5N550______.IES EASC_Q5N550______.IES EASC_R5N550______.IES EASC_S5N550______.IES EASC_T5N550______.IES EASC_U5N550______.IES EASC_V5N750______.IES EASC_A4F550______.IES EASC_B4F550______.IES EASC_C4F550______.IES EASC_D4F550______.IES EASC_E4F550______.IES EASC_F4F550______.IES EASC_G4F550______.IES EASC_H4F550______.IES EASC_J4F550______.IES EASC_K4F550______.IES EASC_L4F750______.IES EASC_A3F550______.IES EASC_B3F550______.IES EASC_C3F550______.IES EASC_D3F550______.IES EASC_E3F550______.IES EASC_F3F550______.IES EASC_G3F550______.IES EASC_H3F550______.IES EASC_J3F550______.IES EASC_K3F550______.IES EASC_L3F750______.IES EASC_A2F550______.IES EASC_B2F550______.IES EASC_C2F550______.IES EASC_D2F550______.IES EASC_E2F550______.IES EASC_F2F550______.IES EASC_G2F550______.IES EASC_H2F550______.IES EASC_J2F550______.IES EASC_K2F550______.IES EASC_L2F750______.IES EASC_KAF550______.IES EASC_LAF750______.IES Photometrics EASC Type V - Symmetric Short (U5) 33,000 Lumens, 5000K (EASC_U5N550__.ies) EASC Type V - Symmetric Medium (K5) 30,000 Lumens, 5000K (EASC_K5N550__.ies) 10716 11631 8037 8723 5358 5815 2 2679 .2 .5 1 .1 .2 .1 Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 45° Vertical plane through horizontal angle of 72° EASC Type IV - Asymmetric Forward (K4) 30,000 Lumens, 5000K (EASC_K4F550__.ies) .5 1 Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 20° Vertical plane through horizontal angle of 52° EASC Type IV - Asymmetric Forward (E4) 12,900 Lumens, 5000K (EASC_E4F550__.ies) 21110 9077 15832 6808 10555 .2 2 2908 4539 .1 2 .2 5277 .1 .5 .5 2269 1 Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 45° Vertical plane through horizontal angle of 72° 22807 9607 17105 7205 11404 .2 .1 4803 2 5702 .5 .2 .1 1 Vertical plane through horizontal angle of maximum candlepower at 20° Vertical plane through horizontal angle of 52° EASC Type II - Asymmetric Narrow (K2) 31,900 Lumens, 5000K (EASC_K2F550__.ies) .1 .2 .5 Grid Distance in Units of Mounting Height at 30’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 20° Vertical plane through horizontal angle of 52° EASC Type II - Asymmetric Narrow (E2) 13,400 Lumens, 5000K (EASC_E2F550__.ies) 19313 8113 14485 6085 .1 .2 9657 4828 .5 2 Vertical plane through horizontal angle of maximum candlepower at 65° Vertical plane through horizontal angle of 60° 4056 2028 1 Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade 2 2402 1 Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 45° Vertical plane through horizontal angle of 72° EASC Type III - Asymmetric Wide (E3) 13,900 Lumens, 5000K (EASC_E3F550__.ies) EASC Type III - Asymmetric Wide (K3) 33,000 Lumens, 5000K (EASC_K3F550__.ies) .5 Grid Distance in Units of Mounting Height at 30’ Initial Footcandle Values at Grade 2 1 Grid Distance in Units of Mounting Height at 30’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 65° Vertical plane through horizontal angle of 60° Photometrics EASC Type II - Assymetric Auto (KA) 35,400 Lumens, 5000K (EASC_KAF550__.ies) 12923 17121 9692 12841 2 6462 .5 .2 EASC Type II - Assymetric Auto (LA) 46,900 Lumens, 5000K (EASC_LAF750__.ies) 3231 .1 .5 .2 .1 1 Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 0° Vertical plane through horizontal angle of 37° 2 8561 4280 1 Grid Distance in Units of Mounting Height at 40’ Initial Footcandle Values at Grade Vertical plane through horizontal angle of maximum candlepower at 0° Vertical plane through horizontal angle of 37° H-Motion Sensing Option: • Intended for high mounting applications, between 15-30ft (4.57-9.14m). For mounting heights exceeding 30ft, pole mounted sensors are recommended. • Provides a coverage area radius for walking motion of 15-20ft (4.57-6.10m). • Provides 270° of coverage (~90° is blocked by the pole). • Comes standard with 50% dimmed light output with no occupancy, and full power at occupancy. • Comes standard with photocell function. Note: It is not necessary to also purchase PE receptacle or control. • Comes standard with a 5 minute occupancy time delay and a 5 minute ramp-down to the 50% dimmed level. • Must order with decorative mounting arm options “A” or “B”. • Fixture power increase of 1W expected with sensor use. Note: Standard options may be reprogrammed in the field. Reprogramming instructions included in product shipment. Sensor Pattern: 20’ 10’ 20’ 10’ 10’ 10’ 20’ Sensing Pattern Area Fixture Up to 30 ft. 20’ Product Dimensions (Option A) 10” Arm for Square Pole Mount (Option B) 10” Arm for Round Pole Mount (Option D) 10” Arm for Square Pole Mount or Round Pole Mount Option D includes all mounting hardware in Option A and Option B 34.5 in. [878 mm] 10.9 in. [277 mm] Square Pole 16.9 in. [430 mm] 16.0 in. [406 mm] 10.5 in. [266 mm] 34.1 in. [867 mm] Round Pole TOP VIEW Square Pole Adaptor (A and D) Round Pole Arm (B and D) 3.5 inch - 4.5 inch OD Pole (89 mm OD - 115 mm OD) 4.7 in. 2.5 in. [119 mm] [63 mm] 4.4 in. 8.4 in. [213 mm] [111 mm] R8.680 in. [R220 mm] FRONT VIEW SIDE VIEW 0.438 in. [11 mm] 4.392 in. [112 mm] 1.711 in. [43 mm] 2.125 in. [54 mm] 0.625 in. [16 mm] 2.008 in. [51 mm] 3.188 in. 4.250 in. [81 mm] [108 mm] 5.438 in. [138 mm] 6.375 in. 4.812 in. [162 mm] [162 mm] 1.312 in. [33 mm] 0.438 in. [11 mm] BACK VIEW Option B and D Round Pole 3.5 inch - 4.5 inch OD Pole (89 mm OD - 115 mm OD) D ATA BACK VIEW Option A and D Square Pole 3.5 inch - 4.5 inch Pole (89 mm - 115 mm) • Approximate net weight: 43-47 lbs (19.50 - 21.32 kgs) Contact manufacturer for specific configuration weight. • Effective Projected Area (EPA) with 10” Mounting Arm: 0.97 sq ft max (0.09 sq m) Product Dimensions (Option C) Slipfitter Arm Mount 28.6 in. [726 mm] 5.0 in. [126 mm] 16.9 in. [430 mm] 16.0 in. [406 mm] TOP VIEW 2 in. Nominal PIPE ONLY (2.375 in. OD) [60 mm OD] 2 in. Nominal PIPE ONLY (2.375 in. OD) [60 mm OD] 4.7 in. 2.5 in. [119 mm] [63 mm] 4.9 in. [125 mm] R8.680 in. [R220 mm] D ATA BACK VIEW SIDE VIEW FRONT VIEW • Approximate net weight: 41-45 lbs (18.60 - 20.41 kgs) Contact manufacturer for specific configuration weight. • Effective Projected Area (EPA) with Slipfitter: 0.47 sq ft max (0.04 sq m) (Option S) Knuckle Arm Mount 3.2 in. [81 mm] 26.8 in. [681 mm] 16.9 in. [430 mm] 16.0 in. [406 mm] KNUCKLE SLIPFITTER ARM MOUNT 0° TO 45° AIMING RANGE TOP VIEW 3 inch OD (max) [76 mm OD] 2.3 in. [57 mm] 7.3 in. [186 mm] D ATA BACK VIEW 45° max upward aim 5.0 in. 2.5 in. [127 mm] [63 mm] R26.9 in. [R683 mm] SIDE VIEW FRONT VIEW • Approximate net weight: 41-45 lbs (18.60 - 20.41 kgs) Contact manufacturer for specific configuration weight. • Effective Projected Area (EPA) with fixture mounted at 45° upward: 1.97 sq ft max Mounting Information Mounting Arms for Slipfitter Order separately with Mounting Option C (External Slipfitter) SQUARE POLE MOUNTING ARM 3.5 TO 4.5-inch (89 to 114mm) SQUARE (WILL ALLOW 4 FIXTURES PER POLE @ 90 DEGREES.) 10 . [26 500 i 7 m n. m] Drilling Templates for Slipfitter Arms & Arm Mount SQUARE POLE MOUNTING .312 in. DIA. [8 mm DIA.] 5.250 in. [133 mm MIN.] 1.812 in. [46 mm] .438 in. DIA. [11 mm DIA.] (2 Places) 2.196 in. [56 mm] 4.392 in. [112 mm] 1.250 in. DIA. [32 mm DIA.] Hole .656 in. [17 mm] 1.312 in. [33 mm] ORDER SEPARATELY FROM FIXTURE AS CATALOG NUMBER SPA-EAMT10BLCK “Black” SPA-EAMT10DKBZ “Dark Bronze” ROUND POLE MOUNTING ARM ROUND POLE MOUNTING 3.5 TO 4.5-inch (89 to 114mm) OD (WILL ALLOW 4 FIXTURES PER POLE @ 90 DEGREES.) 3.5 TO 4.5-inch (89 to 114mm) OD round pole mounting arm 10 . [26 500 i 7 m n. m] .312 in. DIA. [8 mm DIA.] 5.250 in. [133 mm MIN.] 1.812 in. [46 mm] .750 in. DIA. [19 mm DIA.] Hole .438 in. DIA. [11 mm DIA.] (2 Places) 2.719 in. [69 mm] 5.438 in. [138 mm] ORDER SEPARATELY FROM FIXTURE AS CATALOG NUMBER RPA-EAMT10BLCK “Black” RPA-EAMT10DKBZ “Dark Bronze” Wall Mounting Bracket Adapter Plate ORDER SEPERATELY FROM FIXTURE AS CATALOG NUMBER WMB-EAMT06 *NOTE: For Wall Mounting, order luminaire with mounting arm: C = EXT Slip-fitter 2” Pipe (2.378 in. OD) supplied with leads. Other mounting patterns are available for retrofit installations. Contact manufacturing for other available mounting patterns. www.gelighting.com GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. GE Lighting is a business of the General Electric Company. © 2016 GE. OLP3090 (Rev 02/22/16) GE Lighting Evolve LED Area Light ™ Shielding for EAS Area Light Fixtures The next evolution of the GE Evolve™ LED Area Light delivers even better trespass control. GE’s exclusive reflective optical ring design produces superior vertical illuminace and efficiently directs the light without wasteful and unwelcomed light spill into neighboring properties. Due to the extensive variation of parking lot configurations coupled with tightening ordinances, GE now offers a full array of shielding to accommodate challenging sites. The shielding options available for the GE Evolve Area Light focus on the following applications: • Left and Right cutoff • Front cutoff • Backlight control and B-U-G improvement Within each of the shielding families, there are multiple shielding cutoff levels that are categorized in mounting height (MH) increments. GE accommodates cutoff distance from the pole from 1MH to 2.5 MH in 0.5 MH increments. The shields that are listed are for the most common applications. Please contact the manufacturer if your need is not listed. MH 1 MH 2.5 MH All shields can be installed easily in the field. The next evolution of the GE Evolve LED Area Light and shielding options will help you meet any parking lot challenge. imagination at work EAS Shielded Fixture Examples Single Module Left/Right Shield Double Module Left/Right Shield Single Module Front Shield Double Module Front Shield Single Module Back Shield Double Module Back Shield Type V Shielding Shield Orientation Any Side Any Side Cutoff Distance Fixture Type 0.5 1 1.5 2 Module 2 2.5 0.5 1 1.5 2 Module 2 2.5 Shield Order Logic ELS-EASX-MS1-BLCK ELS-EASX-MS2-BLCK ELS-EASX-MS3-BLCK ELS-EASX-MS4-BLCK ELS-EASX-MS5-BLCK ELS-EASX-SS1-BLCK ELS-EASX-SS2-BLCK ELS-EASX-SS3-BLCK ELS-EASX-SS4-BLCK ELS-EASX-SS5-BLCK Type IV Shielding Shield Orientation Cutoff Distance Fixture Type Shield Order Logic 1 ELS-EASX-FF2-BLCK 1.5 ELS-EASX-FF3-BLCK Front 2 Module 2 ELS-EASX-FF4-BLCK 2.5 ELS-EASX-FF5-BLCK 1 ELS-EASX-RF2-BLCK 1.5 ELS-EASX-RF3-BLCK Front 1 Module 2 ELS-EASX-RF4-BLCK 2.5 ELS-EASX-RF5-BLCK 0.5 ELS-EASX-FS1-BLCK 1 ELS-EASX-FS2-BLCK Side 1.5 2 Module ELS-EASX-FS3-BLCK 2 ELS-EASX-FS4-BLCK 2.5 ELS-EASX-FS5-BLCK 0.5 ELS-EASX-RS1-BLCK 1 ELS-EASX-RS2-BLCK Side 1.5 1 Module ELS-EASX-RS3-BLCK 2 ELS-EASX-RS4-BLCK 2.5 ELS-EASX-RS5-BLCK Backshort2 ModuleELS-EASX-FBN-BLCK long ELS-EASX-FBL-BLCK Back long 1 Module ELS-EASX-RBL-BLCK Type III Shielding Shield Orientation Cutoff Distance Fixture Type Shield Order Logic 1 ELS-EASX-WF2-BLCK 1.5 ELS-EASX-WF3-BLCK Front 2 Module 2 ELS-EASX-WF4-BLCK 2.5 ELS-EASX-WF5-BLCK 1 ELS-EASX-DF2-BLCK 1.5 ELS-EASX-DF3-BLCK Front 1 Module 2 ELS-EASX-DF4-BLCK 2.5 ELS-EASX-DF5-BLCK 0.5 ELS-EASX-WS1-BLCK 1 ELS-EASX-WS2-BLCK Side 1.5 2 Module ELS-EASX-WS3-BLCK 2 ELS-EASX-WS4-BLCK 2.5 ELS-EASX-WS5-BLCK 0.5 ELS-EASX-DS1-BLCK 1 ELS-EASX-DS2-BLCK Side 1.5 1 Module ELS-EASX-DS3-BLCK 2 ELS-EASX-DS4-BLCK 2.5 ELS-EASX-DS5-BLCK Backshort2 ModuleELS-EASX-WBN-BLCK long ELS-EASX-WBL-BLCK Back long 1 Module ELS-EASX-DBL-BLCK Type II Shielding Shield Orientation Cutoff Distance Fixture Type Shield Order Logic 0.5 ELS-EASX-NS1-BLCK 1 ELS-EASX-NS2-BLCK Side 1.5 2 Module ELS-EASX-NS3-BLCK 2 ELS-EASX-NS4-BLCK 2.5 ELS-EASX-NS5-BLCK 0.5 ELS-EASX-AS1-BLCK 1 ELS-EASX-AS2-BLCK Side 1.5 1 Module ELS-EASX-AS3-BLCK 2 ELS-EASX-AS4-BLCK 2.5 ELS-EASX-AS5-BLCK short ELS-EASX-NBN-BLCK Back 2 Module long ELS-EASX-NBL-BLCK Back long 1 Module ELS-EASX-ABL-BLCK www.gelighting.com GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. GE Lighting and GE Lighting Solutions, LLC are businesses of the General Electric Company. © 2015 GE. OLP3083 (Rev 06/08/15) GE Installation Guide GEH-6016B Lighting Evolve LED Area Light ™ Scalable Fixture (EAS) BEFORE YOU BEGIN Read these instructions completely and carefully. Save these instructions for future use. WARNING Risk of electrical shock. Disconnect power before servicing or installing product. WARNING Risk of injury or damage. Unit will fall if not installed properly. Follow installation instructions. CAUTION Risk of injury. Wear safety glasses and gloves during installation and servicing. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [ A ] est conforme à la NMB-003 du Canada. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in a ccordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. imagination at work • This luminaire is designed for outdoor lighting service, and should not be used in areas of limited ventilation, or in high ambient temperatures. • Best results will be obtained if installed and m aintained according to the following recommendations. • Luminaire is designed to operate in ambient temperatures ranging from -40°C to 50°C (-40°C to 35°C for >400W) and to be mounted horizontally to a vertical pole with LEDs facing down, or aimed up to 45° upward with a Knuckle slip fitter. SPECIFICATIONS • • • Weight: Maximum weight <50 lbs (22.68 kg) EPA: Horizontal mounting: 0.97 sq ft max (0.09 sq M) 45° mounting: 1.97 sq ft max (0.18 sq M) IP Rating: Optical 65, Standard Electrical Enclosure: UL 1598 Wet Location Rated 1 UNPACKING 3b Round Pole Architectural Arm Mounting • This luminaire has been properly packed so that no parts should have been damaged during transit. • Inspect to confirm. 2 HANDLING • Damage may occur if luminaire is improperly handled outside of pack. • Do not impact or stack luminaire after removal from packaging. 3 This luminaire has been configured specifically to mount to round pole 3.5-4.5 inches (89-114mm) in diameter. Hole pattern on round pole shall be in accordance with Figure 2. • Place fixture against pole. • Install 3/8 bolt, lock washer and washer in top as shown and tighten into nut plate. • Open arm door and install 3/8 bolt, lock washer and washer inside arm as shown and tighten into nut plate. (See Figure 3 and 4) • Torque top and bottom bolts to 25 - 32 ft-lbs (34-43 N-m). • Inspect installation to ensure fixture is secure. WARNING MOUNTING Under no conditions should architectural a rm mounting bolts be torqued to greater than 32 ft-lbs. (43 N-m) WARNING DRILLING TEMPLATE ROUND POLE MOUNTING 3.5 to 4.5 inch (89 to 114mm) OD round pole mounting arm. Risk of injury or damage. Unit will fall if not installed properly. Follow installation instructions. Follow the appropriate installation instructions based on your selected mounting method: a. Slipfitter Mounting b. Round Pole Architectural Arm Mounting c. Square Pole Architectural Arm Mounting d. Knuckle Slipfitter for 2 3/8 in. (60mm) OD Tenon (0 to 45° vertical aiming angle) 3a Slipfitter Mounting This luminaire has been configured specifically to mount to a 2-inch pipe brackets (2-3/8” OD). • • • Hold luminaire approximately level with pipe. Pull wires through arm and place slip fitter over 2-inch (51mm) pipe (2 3/8-inch (60mm) OD). Tighten the (4) slipfitter 3/8 bolts to 10-14 ft-lbs (14-19 N-m). Tighten jam nuts after bolts have been tightened. (See Figure 1) Inspect installation to ensure fixture is secure. WARNING Under no conditions should slipfitter bolts be torqued to a level greater than 14 foot pounds (19 N-m). .312 in. DIA. (8 mm DIA.) 5.2500 in. (133 mm) (MIN.) .438 in. DIA. (11 mm DIA.) (2 PLACES) 1.8120 in. (46 mm) 2.7190 in. (69 mm) .750 in. DIA. (19 mm DIA.) (HOLE) FIGURE 2 Torque Top Bolt to 25-32 ft-lbs. (34-43N-m) Door Torque Bottom Bolt to 25-32 ft-lbs. (34-43N-m) Arm Door Screw FIGURE 3 Section view: Round Pole Mounting Architectural Arm with Door Slipfitter 3/8 Bolts and Jam Nuts Pole Nut Plate FIGURE 1 Bolt, Lock Washer, Flat Washer Arm Door Screw FIGURE 4 5.4380 in. (138 mm) 3c Square Pole Architectural Arm Mounting FIXTURE ARM TO ARM ADAPTER Torque Top Bolt to 25 - 32 ft-lbs. (34-43 N-m) This luminaire has been configured the same as 3b and an adapter plate has been included to mount to a square pole. Hole pattern on square pole shall be in accordance with Figure 5. • Orient adapter block so that oval shaped through hole is closer to top than bottom of adapter. • With adapter block end oriented properly, mount adapter block to pole with the nut plate and 3/8-16 bolts and washer supplied as shown. Torque 3/8-16 bolts to 25 - 32ft-lbs (34-43 N-m). (See Figure 6) • Place fixture against adapter block. • Install 3/8 bolt, lock washer and washer in top as shown and tighten into adapter block. (See Figure 7) • Open arm door and Install 3/8 bolt into tapped hole of adapter block. (See Figure 7) • Torque top and bottom bolts to 25 - 32 ft-lbs (34-43 N-m). • Inspect installation to ensure fixture is secure. DRILLING TEMPLATE SQUARE POLE MOUNTING .312 in. DIA. (8 mm DIA.) 5.2500 in. (133 mm) (MIN.) 1.8120 in. (46 mm) .438 in. DIA. (11 mm DIA.) (2 PLACES) 2.1960 in. (56 mm) 4.3920 in. (112 mm) 1.250 in. DIA. (32 mm DIA.) (HOLE) Torque Bottom Bolt to 25 - 32 ft-lbs. (34-43 N-m) FIGURE 7 3d Knuckle Slipfitter for 2-3/8 in. (60mm) to 3.0 in. (76mm) OD Tenon This luminaire has been configured specifically to provide 0 to 45° vertical aiming in 5° increments and mount on 2-3/8-inch O.D. (73mm) through 3-inch O.D. (76mm) pipe. • • • • Place slipfitter on the tenon. Three set screws are used to clamp the floodlight securely to the pipe. Tighten set screws to 18-22 foot pounds (24-30 N-m). To aim the luminaire, loosen the knuckle bolt, adjust the aim 0 to 45° , and tighten to 45-50 ft-lbs (61-68 N-m). Inspect installation to ensure fixture is secure. 26.776 in. [680 mm] 2.3 in. [57 mm] 45° max upward aim .656 in. (17 mm) 1.312 in. (33 mm) FIGURE 5 5.0 in. [127 mm] 7.3 in. [186 mm] R26.9 in. [R683 mm] Tighten Knuckle Bolt to 45-50 Foot Pounds 3.805 in. [97 mm] ADAPTER PLATE FOR SQUARE POLE 2-3/8 in. (60mm) to 3.0 in. (76mm) OD only Tighten 3 Set Screws to 18-22 Foot Pounds Nut Plate Adapter Block 4 WIRING CAUTION Risk of Damage or Injury: Door should be closed with screw until fixture in final location. 3/8-16 Washer and Bolts Torque Bolts to 25 - 32ft-lbs. (34-43 N-m) FIGURE 6 • NOTE: Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements. • Strain relief for incoming power must be p rovided in the pole top by the customer. • Supply Wire Type and Size, for Customer Connection to Terminal Board: 16 AWG (1.5mm2) to 6 AWG (10mm2) Solid or Stranded. Terminal Board Connections: Terminal Board Position Supply Type L1 High Line G Ground N/L2 Low Line/Neutral • NOTE: Verify that supply voltage is correct by comparing it to nameplate inside door or on carton. Photoelectric Control: • (If option present)—Photoelectric control receptacle should be oriented before control is installed. • Loosen the two holding screws and rotate receptacle until “North” is directed as near as possible to true North. • Verify that the grommet under the PE receptacle is seated and that there are no gaps that will allow water to enter the fixture from under the PE receptacle. • Tighten holding screws and install control. Electrical Connection: • • • • • Connect Luminaire wire leads to supply wire. Connections are to be made in interior of pole. Replace pole cap. A wiring diagram is provided on a label inside luminaire for reference. For units without leads, connections may be made to terminal board inside fixture. Note that care should be exercised not to pinch leads between door and housing when closing the door. External Dimming Control (If Applicable): • Gray Lead = 0VDC (-) • Violet Lead = Up To 10VDC (+) Dimming Input/Output Control Voltage1 Low (0-1.25V) High(7.5-10V) Nominal Input Wattage2 10% of Max 100% Nominal Lumen Output2 • 1 Linear Transition between Low and High • 2 Component and system tolerance may affect the end point levels and linearity of transition PE Dimming Control (If Applicable): • No external connections for Dimming are required when the GE Dimming PE Control and GE Dimming PE Receptacle is used. • All dimming control connections will be made between the Dimming PE and Luminaire through the included PE Receptacle. • Refer to instructions included with GE Dimming PE Control regarding appropriate settings for dimming control. Occupancy Sensor (optional): • • The programmable occupancy sensor is shipped with a default program which may be modified using the button on the sensor. The sensor has a separate set of instructions on programming which is included. 5 MAINTENANCE / CLEANING WARNING Risk of electric shock. Make certain power is off before attempting any maintenance. • To maintain high efficiency of the lens, occasional cleaning of the outer lens surface may be needed, with frequency dependent on local conditions. • Use a mild soap or d etergent, which is essentially neutral pH (pH approximately 6 to 8), nonabrasive, and which c ontains no chlorinated or aromatic hydrocarbons. • Wash thoroughly, using a soft cloth. • Rinse with clean, cold water and wipe dry. 6 STORAGE • Prior to installation, units should NOT be stored outside in c orrugated boxes (cardboard b oxes) alone. • Until installation, all units should be placed in a covered dry storage area. The storage area should not exceed -40°C (-40°F) to 50°C (122°F). - This can be preferably in a roofed area or with a tarp that is secured in such a way to keep water off of the corrugated boxes (cardboard boxes). These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to GE Lighting. GE Lighting • 1-888-MY-GE-LED (1 - 888 - 69 - 43 - 533) • www.gelighting.com GE Lighting is a subsidiary of the General Electric Company. Evolve and the GE brand and logo are trademarks of the General Electric Company. © 2014 GE Lighting. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. 35-201578-208 (Rev 09/09/14) English GE Guide d’installation GEH-6016B Lighting Luminaire de zone à DEL Evolve ™ Appareil d’éclairage évolutif (EAS) ARRÊT AVANT DE COMMENCER Lisez attentivement toutes ces instructions. Conservez ces instructions pour référence future. AVERTISSEMENT Risque de choc électrique. Déconnectez l’alimentation électrique avant d’installer ou réparer ce produit. AVERTISSEMENT Danger de blessure et de dommage matériel. L’appareil tombera au sol s’il est mal installé. Suivez les instructions d’installation. ATTENTION Danger de blessure. Lors de l’installation et de la réparation de cet appareil, porter des lunettes et des gants de sécurité. Cet appareil est conforme aux exigences de la partie 15 des règles de la FCC. Son utilisation est sujette aux conditions suivantes : (1) cet appareil ne doit pas causer d’interférences nuisibles; (2) cet appareil doit accepter toutes les interférences reçues, y compris celles p ouvant causer un fonctionnement indésirable. Ce DEFR de la classe [ A ] est conforme à la NMB-003 du Canada. Remarque : Cet appareil a été testé et reconnu conforme aux limites établies pour les appareils numériques de classe A, selon la partie 15 des règles de la FCC. Ces limites sont conçues pour assurer une protection raisonnable contre les interférences nuisibles dans un environnement commercial. Cet appareil génère, utilise et émet de l’énergie sous forme de radiofréquences, de sorte que si son installation et son utilisation ne sont pas conformes à la notice d’utilisation, il peut être la cause de parasites nuisibles aux communications radio. L’utilisation de cet équipement dans une zone résidentielle risque fort de causer des interférences nuisibles, auquel cas l’utilisateur devra corriger le problème à ses propres frais. imagination at work • Ce luminaire a été conçu pour une utilisation à l’extérieur et ne doit pas être employé sur un site mal ventilé ni dans un endroit clos dont la température ambiante peut être élevée. • Pour obtenir des performances optimales, il doit être installé et entretenu conformément aux recommandations suivantes. • Ce luminaire a été conçu pour fonctionner à des températures ambiantes allant de -40°C à 50°C (-40°C à 35°C pour >400W) et doit être installé horizontalement à un poteau vertical de manière à ce que les diodes soient orientées vers le bas, ou incliné vers le haut à 45° avec un adaptateur d’emboîtement. SPÉCIFICATIONS • Poids : Poids maximum < 50 lb (22,68 kg) • EPA : Montage horizontal : 0,97 pi² max (0,09 m²) Montage à 45° : 1,97 pi² max (0,18 m²) • Classification IP : Module optique 65, boîtier électrique standard : Homologation UL 1598 pour environnement mouillé 1 DÉBALLAGE 3b Montage avec bras architectural sur poteau rond • Ce luminaire a été soigneusement emballé pour qu’aucune pièce ne subisse de dommages durant le transport. • Procédez à une inspection pour vous en assurer. 2 MANUTENTION • Si le luminaire est incorrectement manipulé hors de son emballage, il risque d’être endommagé. • Lorsque le luminaire est sorti de son emballage, il ne doit pas recevoir le moindre coup ni être empilé. 3 ASSEMBLAGE Ce luminaire a été spécialement configuré pour être monté sur un poteau ayant un diamètre de 3,5 po à 4,5 po (89-114 mm). La configuration des trous sur le poteau rond doit être conforme à la Figure 2. • Placez le luminaire contre le poteau. • Installez le boulon de 3/8 po, la rondelle de frein et la rondelle plate dans le haut (conformément à l’illustration) et serrez dans la plaque d’écrou. • Ouvrez le volet du bras et installez le boulon de 3/8 po, la rondelle de frein et la rondelle plate dans le bras (conformément à l’illustration) et serrez dans la plaque d’écrou (voir les figures 3 et 4). • Serrez les boulons du haut et du bas au couple de 25-32 lb-pi (34-43 Nm). • Vérifiez la solidité de l’installation. AVERTISSEMENT Danger de blessure et de dommage matériel. L’appareil tombera au sol s’il est mal installé. Suivez les instructions d’installation. Sélectionnez les instructions d’installation correspondant à la méthode de montage applicable : a. Montage sur joint coulissant b. Montage avec bras architectural sur poteau rond c. Montage avec bras architectural sur poteau carré d. Adaptateur d’emboîtement pour tenon OD 2-3/8 po. (60 mm) (angle d’inclinaison verticale de 0 à 45°) 3a Montage sur joint coulissant Ce luminaire a été spécialement configuré pour être monté sur des supports de tuyaux de 2 pouces (D. E. 2 3/8 po). • Tenez le luminaire approximativement au niveau par rapport au tuyau. Faites passer les fils dans le bras et placez le joint coulissant sur le tuyau de 2 pouces (51 mm) (D. E. 2 3/8 po / 60 mm). • Serrez les quatre boulons de 3/8 po sur le joint coulissant au couple de 10-14 lb-pi (14-19 Nm). Après le serrage des boulons, serrez les contre-écrous (voir la figure 1). • Vérifiez la solidité de l’installation. AVERTISSEMENT Les boulons du joint coulissant ne doivent jamais être serrés avec un couple dépassant 14 lb pi (19 Nm). AVERTISSEMENT Les boulons de montage du bras architectural ne doivent jamais être serrés avec un couple dépassant 32 lb pi (43 Nm). GABARIT DE PERFORATION MONTAGE SUR POTEAU ROND Bras de montage sur poteau rond avec D.E. de 3,5 à 4,5 po (89 à 114 mm) .312 po DIA. (8 mm DIA.) 5.2500 po (133 mm) (MIN.) .438 po DIA. (11 mm DIA.) (2 ENDROITS) 1.8120 po (46 mm) 2.7190 po (69 mm) .750 po DIA. (19 mm DIA.) (TROU) 5.4380 po (138 mm) FIGURE 2 Serrer le boulon supérieur au couple de 25-32 lb-pi (34-43N-m) Volet Serrer le boulon supérieur au couple de 25-32 lb-pi (34-43N-m) Vis de volet de bras FIGURE 3 Vue en coupe : Montage sur poteau rond Bras architectural avec volet Boulons 3/8 de joint coulissant avec contre-écrous Poteau Plaque d’écrou FIGURE 1 Boulon, rondelle de frein, rondelle plate Vis de volet de bras FIGURE 4 3c Montage avec bras architectural sur poteau carré Ce luminaire a été configuré comme celui du paragraphe 3b et une plaque adaptatrice a été ajoutée pour permettre une installation sur un poteau carré. La configuration des trous sur le poteau carré doit être conforme à la Figure 5. • Orientez la plaque adaptatrice afin que le trou ovale soit plus près du haut que du bas de la plaque. • Après avoir vérifié l’orientation de l’extrémité de la plaque adaptatrice, installez la plaque sur le poteau avec l’aide de la plaque d’écrou, des boulons 3/8-16 et des rondelles incluses, conformément à l’illustration. Serrez les boulons 3/8-16 au couple de 25-32 lb-pi (34-43 Nm) (voir la figure 6). • Placez le luminaire contre la plaque adaptatrice. • Installez le boulon de 3/8 po, la rondelle de frein et la rondelle plate dans le haut (conformément à la figure 7) et serrez dans la plaque d’écrou. • Ouvrez le volet du bras et installez un boulon de 3/8 po dans le trou fileté du bloc adaptateur (voir la figure 7). • Serrez les boulons du haut et du bas au couple de 25-32 lb-pi (34-43 Nm). • Vérifiez la solidité de l’installation. GABARIT DE PERFORATION MONTAGE SUR POTEAU CARRÉ .312 po DIA. (8 mm DIA.) 5.2500 po (133 mm) (MIN.) .438 po DIA. (11 mm DIA.) (2 ENDROITS) 2.1960 po (56 mm) 1.8120 po (46 mm) 4.3920 po (112 mm) 1.250 po DIA. (32 mm DIA.) (TROU) BRAS DU LUMINAIRE SUR ADAPTATEUR Serrer le boulon supérieur au couple de 25-32 lb-pi (34-43 Nm) Serrer le boulon inférieur au couple de 25-32 lb-pi (34-43 Nm) FIGURE 7 3d Adaptateur d’emboîtement pour OD tenon de 2-3/8 po. (60 mm) à 3 po. (76 mm) Ce luminaire a été spécifiquement configuré pour fournir une inclinaison verticale de 0 à 45° par incréments de 5° et se monter sur un tuyau OD de 2-3/8-po. (73 mm) à 3 po. (76 mm). • • • • Placez l’adaptateur d’emboîtement sur le tenon. On utilise trois vis de fixation pour solidement fixer le projecteur au tuyau. Serrez les vis de fixation jusqu’à 18-22 pied-livre (24-30 N-m). Pour orienter le luminaire, desserrez l’écrou articulé, ajustez l’orientation entre 0 et 45° et vissez jusqu’à 45-50 pied-livre (61-68 N-m). Vérifiez la solidité de l’installation. 26.776 in. 26.776 in. [680 mm) mm] (680 2.3 in. 2.3 in. (57 [57 mm) mm] 45° max upward aim Orientation vers le haut 45° max. 5.0 5.0 in. in. [127 mm) mm] (127 .656 po (17 mm) 1.312 po (33 mm) FIGURE 5 7.3 7.3 in. in. (186 [186 mm) mm] R26.9 in. R26.9 in. [R683 mm] (R683 mm) Serrez écrou articulé Tighten Knuckle Bolt to 45-50 Foot Pounds jusqu’à 45-50 pied-livre 3.805 in. 3.805 in. [97 mm) mm] (97 PLAQUE ADAPTATRICE POUR POTEAU CARRÉ 2-3/8de in.2-3/8 (60mm)(60 to 3.0 in. (76mm) OD mm) à 3 po.OD (76only mm) uniquement Tighten 33Set to 18-22 Serrez visScrews de fixation jusqu’à 18-22 pied-livre Foot Pounds Plaque d’écrou Plaque adaptatrice 4 CÂBLAGE ATTENTION Danger de blessure et de dommage matériel. Le volet doit être fermé avec sa vis jusqu’à ce que le luminaire soit à son emplacement final. Boulons 3/8-16 et rondelles Serrer les boulons au couple de 25-32 lb-pi (34-43 Nm) FIGURE 6 • REMARQUE: Toutes les connexions doivent être conformes aux normes électriques nationales et à la réglementation locale en vigueur (code électrique du Canada et réglementation locale applicable). • Un dispositif anti-tension doit être installé par le client sur le câble d’alimentation en haut du poteau. • Type et taille du câble d’alimentation (pour connexion par le client sur plaque de connexions) : 16 AWG (1,5mm2) à 6 AWG (10mm2) plein ou tressé. Connexions de la plaque de connexions : Position sur la plaque de connexions Type d’alimentation L1 Ligne de phase G Terre N/L2 Ligne basse/neutre • REMARQUE: Assurez vous que la tension électrique est adéquate en vérifiant la plaque signalétique à l’intérieur du volet ou sur la boîte. Commande photoélectrique : • (Si l’option est choisie) Le réceptacle de la commande peut être orienté avant d’installer la commande. • Desserrez les deux vis de retenue et faites tourner le réceptacle jusqu’à ce que l’inscription « North » soit orientée le plus près possible du nord véritable. • Assurez-vous que la douille sous le réceptacle de commande photoélectrique est bien appuyée et qu’il n’existe aucun espace d’infiltration d’eau sous le réceptacle. • Serrez les vis de retenue et installez la commande. Branchements électriques : • Connectez les fils conducteurs du luminaire au câble d’alimentation. • Les connexions doivent être faites à l’intérieur du poteau. • Réinstallez le capuchon du poteau. Un schéma de câblage figure sur une étiquette à l’intérieur du luminaire pour référence. • Si vous utilisez un joint sans fils conducteurs, les connexions peuvent être faites sur la plaque de connexions à l’intérieur du luminaire. • Faites attention de ne pas pincer les fils entre le volet et le boîtier lorsque vous fermez le volet. Gradateur externe (si applicable) : • Fil gris = 0 V c.c. (-) • Fil violet = Jusqu’à 10 V c.c. (+) Gradation, entrée/sortie Tension de commande1 Basse (0-1.25V) Élevée (7.5-10V) Puissance nominale d’entrée2 10% du Maxi 100% Sortie nominale en lumens2 • • 1 Transition linéaire entre basse et élevée Les tolérances des composants et du système peuvent affecter les niveaux de point final et la linéarité de la transition Gradateur photoélectrique (si applicable) • Aucune connexion externe de gradation n’est nécessaire lorsque la commande de gradateur PE et le réceptacle de gradateur PE de GE sont utilisés. • Toutes les connexions de commande de gradation seront réalisées entre le gradateur PE et le luminaire via le réceptacle PE inclus. • Lire les instructions incluses avec la commande de gradateur PE de GE concernant les réglages appropriés de la commande de gradateur. Détecteur de présence (en option) : • Le détecteur de présence programmable est expédié avec une programmation par défaut que l’on peut modifier à l’aide du bouton situé sur le détecteur. • Le détecteur est fourni avec des instructions de programmation séparées. 5 ENTRETIEN ET NETTOYAGE AVERTISSEMENT Risque de choc électrique. Avant de commencer toute opération d’entretien, assurez-vous que l’alimentation électrique est coupée. • Pour conserver l’efficacité de la lentille, nettoyez périodiquement la surface extérieure de la lentille (la fréquence des nettoyages dépendra des conditions locales). • Utilisez un savon doux ou un détergent essentiellement neutre (ayant un pH d’environ 6 à 8), sans abrasif et sans hydrocarbure chloré ou aromatique. • Lavez à fond avec la solution de nettoyage en utilisant un chiffon doux. • Rincez avec de l’eau froide et propre, puis essuyez. 6 ENTREPOSAGE • Avant leur installation, les luminaires ne doivent PAS être entreposés à l’extérieur dans de simples boîtes en carton. • Jusqu’à leur installation, tous les luminaires doivent être conservés dans un lieu de stockage couvert et sec. La température du site de stockage doit se situer entre -40 ºC et 50 ºC (-40 ºF et 122 ºF). - Conservez-les préférablement sous un toit ou sous une bâche installée solidement de façon à ce que l’eau ne puisse atteindre les boîtes en carton. 2 Ces instructions n’ont pas pour but de couvrir tous les détails et toutes les variantes de l’équipement, ni de répondre à tous les impondérables possibles en relation avec l’installation, le fonctionnement et l’entretien. Si vous désirez plus d’informations ou si des problèmes particuliers surviennent qui ne sont pas couverts suffisamment pour les besoins de l’acheteur, le sujet doit être soumis à GE Lighting. GE Lighting • 1-888-MY-GE-LED (1 - 888 - 69 - 43 - 533) • www.gelighting.com GE Lighting est une filiale de la General Electric Company. Evolve ainsi que la marque et le logo GE sont des marques commerciales déposées de la General Electric Company. © 2014 GE Lighting. Les informations fournies ici sont susceptibles de changer sans préavis. Toutes les données sont des valeurs de conception ou caractéristiques lors de leur mesure en conditions de laboratoire. 35-201578-208 (Rev 09/09/14) French GE Guía de Instalación GEH-6016B Lighting Lámpara de Área Evolve LED ™ Lámpara Escalable (EAS, por sus siglas en inglés) ANTES DE EMPEZAR Lea estas instrucciones por completo y detenidamente. Guarde estas instrucciones para uso futuro. ADVERTENCIA Riesgo de descarga eléctrica. Desconecte la fuente de energía antes de dar mantenimiento o al instalar el producto. ADVERTENCIA Riesgo de lesiones o daño. La unidad caerá si no es instalada apropiadamente. Siga las instrucciones de instalación. ADVERTENCIA Riesgo de lesiones. Use gafas de protección y guantes durante instalación y servicio. Este aparato cumple con Parte 15 de las Reglas FCC. Su operación está sujeta a las siguientes dos condiciones: (1) Este aparato no puede causar interferencia perjudicial, y (2) este aparato debe aceptar cualquier interferencia recibida, incluyendo interferencia que pueda causar una operación no deseada. Esta Clase [A] RFLD cumple con el estándar Canadiense ICES-003. Ce DEFR de la classe [ A ] est conforme à la NMB-003 du Canada. Nota: Este equipo ha sido probado y cumple con los límites para la Clase A de aparatos digitales, conforme a la parte 15 de las Reglas FCC. Estos límites están diseñados para proveer protección necesaria para contrarrestar interferencia perjudicial cuando el equipo está en operación en un ambiente comercial. Este equipo genera, usa y puede irradiar energía de radio frecuencia y, si no es instalado y usado conforme a las instrucciones del manual, puede causar interferencia perjudicial a radiocomunicaciones. La operación de este equipo en una zona residencial probablemente causará interferencia perjudicial, en cual caso el usuario deberá corregir por su propia cuenta. imagination at work • La luminaria está diseñada para iluminación exterior, y no deberá ser usada en áreas con ventilación limitada, o a altas temperaturas ambientales. • P ara mejores resultados instale y mantenga de acuerdo con las siguientes recomendaciones. • Las luminarias están diseñadas para operar en tem- peraturas ambiente de -40°C a 50°C (-40°C a 35°C para >400W) y para ser montada en posición horizontal a un poste vertical con los LEDs apuntando hacia abajo, o inclinados al alza hasta a 45° con la ayuda de un vástago desmontable articulado. ESPECIFICACIONES • Peso: Peso máximo <50 libras (22.68 kg) • Área Proyectada Efectiva (EPA, por sus siglas en inglés): Montaje horizontal: 0.97 pies2 max (0.09 m2) Montaje a 45°: 1.97 pies2 max (0.18 m2) • Grado IP: IP65 óptico, caja de protección eléctrica estándar: UL 1598 Especificado para entorno húmedo 1 3b Montaje con Brazo para Poste Redondo DESEMPAQUE • Esta luminaria ha sido empacada adecuadamente para que ninguna parte se dañe durante su envío. • Inspeccione para confirmar su estado. 2 MANEJO •Daños pueden ocurrir si la luminaria se maneja inadecuadamente fuera de su empaque. •No golpee o almacene la luminaria después de haberla removido de su empaque. 3 MONTAJE Esta luminaria ha sido configurada específicamente para ser montada a un poste redondo de 3.5 a 4.5 pulgadas (89-114 mm) de diámetro. La plantilla de perforación deberá ser igual a la Figura 2. • Coloque la luminaria contra el poste. •Instale las tuercas de 3/8, la arandela de seguridad y arandela en la parte superior como se muestra y apriete a la placa para tuerca. •Abra la puerta del brazo e instale el tornillo de 3/8, la arandela de seguridad y arandela dentro del brazo como se muestra y apriete a la placa para tuerca. (Figura 3 y 4). •Aplique torque de 25 a 32 libras por pie (42-43 N-m) a los tornillos superiores e inferiores. •Inspeccione la instalación para asegurarse que el equipo esté firmemente sujeto. ADVERTENCIA Riesgo de lesión o daño. La unidad caerá si no es instalada apropiadamente. Siga las instrucciones de instalación. Siga las instrucciones de instalación apropiadas de acuerdo al método de montaje elegido: a. Montaje de Vástago Desmontable b. Montaje con Brazo Arquitectónico para Poste Redondo c. Montaje con Brazo Arquitectónico para Poste Cuadrado d. Vástago desmontable articulado para acoplamiento de 2- 3/8 pulg. (60mm) de diámetro exterior (0 a 45° inclinación vertical) 3a Montaje de Vástago Desmontable Esta luminaria ha sido configurada específicamente para ser montada a un tubo de soporte de 2 pulgadas (2-3/8 pulgadas de diámetro total). •Mantenga la luminaria aproximadamente a nivel del tubo de soporte. Jale los cables a través del brazo y coloque el vástago desmontable sobre el tubo (2-3/8 pulgadas 60 mm de diámetro total) de 2 pulgadas (51mm) • Apriete los (4) tornillos 3/8 del vástago desmontable a 10-14 libras por pie (14-19 N-m). Apriete las tuercas después que los tornillos hayan sido apretados. (Vea Figura 1). •Inspeccione la instalación para asegurarse que el equipo esté firmemente sujeto. ADVERTENCIA Bajo ninguna circunstancia se deberá apretar los tornillos con un nivel de torque mayor a 14 libras por pie (19 N-m). ADVERTENCIA Bajo ninguna circunstancia se deberá apretar los tornillos del brazo con un torque mayor a 32 libras por pie (43 N-m). PLANTILLA DE PERFORACIÓN MONTAJE EN POSTE REDONDO Brazo de montaje para poste redondo de diámetro exterior de 3.5 a 4.5 pulgadas (89 a 114mm) .312 pulg. DIA. (8 mm DIA.) 5.2500 pulg. (133 mm) (MIN.) .438 pulg. DIA. (11 mm DIA.) (2 LUGARES) 1.8120 pulg. (46 mm) 2.7190 pulg. (69 mm) .750 in. DIA. (19 mm DIA.) (ORIFICIO) 5.4380 pulg. (138 mm) FIGURA 2 Aplique 25-32 libras por pie de torque a tornillo superior (34-43N-m) Puerta Aplique 25-32 libras por pie de torque a tornillo inferior (34-43N-m) Tornillo para Puerta del Brazo FIGURE A3 Vista Seccional: Brazo para Montaje en Poste Redondo Brazo Arquitectónico con Puerta Tornillos 3/8 y Tuercas del Vástago Desmontable Poste Placa para Tuerca Tuerca de Poste, Arandela de Seguridad, Arandela Tornillo para Puerta del Brazo FIGURA 1 FIGURA 4 3c Montaje con Brazo para Poste Cuadrado Esta luminaria está configurada igual que 3b y una placa adaptadora ha sido incluida para ser montada a un poste cuadrado. La plantilla de perforación deberá ser igual a la Figura 5. •Oriente el bloque adaptador de manera que el hoyo ovalado esté más cercano a la parte superior que la inferior del adaptador. •Con el borde del bloque adaptador correctamente orientado, monte el bloque adaptador al poste con la placa para tuerca y los tornillos de 3/8-16 y la arandela incluidos como se muestra. Aplique 25-32 libras por pie (34-43 N-m) de torque a los tornillos de 3/8-16. (Vea Figura 6) • Coloque la lámpara contra el bloque adaptador •Instale el tornillo de 3/8, la arandela de seguridad, y la arandela en la parte superior como se muestra y ajuste al bloque adaptador. (Vea Figura 7) •Abra la puerta del brazo e instale el tornillo de 3/8 al orificio roscado del bloque adaptador. (Vea Figura 7) •Aplique 25-32 libras por pie (34-43 N-m) de torque a los tornillos superiores e inferiores •Inspeccione la instalación para asegurarse que el equipo este firmemente sujeto. PLANTILLA DE PERFORACIÓN MONTAJE EN POSTE CUADRADO .312 pulg. DIA. (8 mm DIA.) .438 pulg. DIA. (11 mm DIA.) (2 LUGARES) 5.2500 pulg. (133 mm) (MIN.) 1.8120 pulg. (46 mm) 2.1960 pulg. (56 mm) 4.3920 pulg. (112 mm) 1.250 pulg. DIA. (32 mm DIA.) (HOLE) Aplique 25-32 libras por pie de torque a tornillo superior (34-43N-m) BRAZO DE LÁMPARA PARA ADAPTADOR DE BRAZO Aplique 25-32 libras por pie de torque a tornillo inferior (34-43N-m) FIGURA 7 3d Vástago Desmontable Articulado para un acoplamiento de diámetro exterior de 2-3/8 pulg. (60mm) a 3.0 pulg. (76mm). Esta luminaria ha sido configurada específicamente para ser posicionada de una manera vertical de 0° a 45° en incrementos de 5° y montada en un tubo de 2-3/8-pulg. de diámetro exterior. (73mm) a 3-pulg. de diámetro exterior. (76mm). •Coloque el vástago desmontable en el acoplamiento. •Los tres tornillos se usan para ajustar la lámpara seguramente al tubo. Apriete los tornillos con un torque de 18-22 libras pies (24-30 N-m). • Para inclinar la luminaria, desatornille el perno de la articulación, ajuste la inclinación de 0 a 45° , y apriete a 45-50 libras pie (61-68 N-m). • Inspeccione la instalación para corroborar que la instalación es segura. 26.776 26.776 pulg. in. [680 (680mm] mm) 2.3 2.3pulg. in. (57 [57 mm) mm] 45°de max upward aimal alza máxima 45° inclinación 5.05.0pulg. in. [127 mm) mm] (127 .656 pulg. (17 mm) 1.312 pulg. (33 mm) FIGURA 5 7.37.3pulg. in. (186 [186 mm) mm] R26.9pulg. in. R26.9 [R683 mm) mm] (R683 Apriete el tornillo Tighten Knuckle Bolt a to 45-50libras Foot Pounds 45-50 pie PLACA ADAPTADORA PARA POSTE CUADRADO 3.805pulg. in. 3.805 [97 mm) mm] (97 Placa de Tuerca 2-3/8 in.pulg. (60mm) to 3.0 in. OD (76mm) only 2-3/8 (60mm) a (76mm) 3.0 pulg. Diámetro Exterior Tighten 3 Set Screws to 18-22 solamente. Apriete los 3 tornillos a 18-22 libras pie. Foot Pounds Bloque Adaptador 4 CABLEADO PRECAUCIÓN Riesgo de lesiones o daño: Puerta debe de estar cerrada con tornillo hasta que el aparato esté en su posición final. 3/8-16 Arandela y Tornillo Aplique 25-32 libras por pie (34-43 N-m) de torque a tornillos FIGURE 6 • N OTA: Todas las conexiones eléctricas deberán realizarse de acuerdo con el Código Eléctrico Nacional y conforme a códigos locales correspondientes. •Liberación de tensión debe de ser proporcionado por el usuario para la fuente de poder en el poste. •Proporcione el tipo y tamaño de cable para la conexión del usuario a la placa terminal: 16 AWG (1.5mm2) a 6 AWG (10mm2) Sólido o Trenzado. Conexiones de Placa Terminal: Posición de Placa Terminal Tipo de Suministro L1 Línea Alta G Puesta a Tierra N/L2 Línea Baja/Neutro • N OTA: Verifique que el voltaje de alimentación sea correcto comparándolo con la placa del fabricante localizada dentro de la puerta o en la caja. Control Fotoeléctrico: •(Si la opción está presente)—Receptáculo de control fotoeléctrico debe de ser orientado antes de instalar el control. •Afloje los dos tornillos sujetadores y gire el receptáculo hasta que el “norte” se dirija lo más posible al norte real. •Verifique que el anillo debajo del receptáculo PE esté fijo y que no hay ningún espacio que deje entrar agua al aparato por debajo del receptáculo PE. • Apriete los tornillos sujetadores e instale el control. Conexión Eléctrica: •Conecte los conectores de cable de la luminaria al cable de suministro. • Conexiones deberán de ser hechas en el interior del poste. • Reemplace la tapa del poste. Diagrama de cableado está como referencia en la etiqueta dentro de la luminaria • Para las unidades sin conectores, las conexiones puedes ser hechas en la placa terminal dentro del aparato. •Tenga cuidado de no pellizcar los conectores de cable entre la puerta y la caja al cerrar la puerta. Control Regulador de Intensidad Externo (Si aplica): • Conector Gris = OVDC (-) • Conector Violeta = Hasta 10VDC (+) Entrada/Salida de Regulador de Intensidad Control de Voltaje1 Entrada Nominal de Potencia2 Salida Nominal de Lumen2 Bajo (0-1.25V) Alto (7.5-10V) 10% de Máximo100% • 1 Transición linear entre alto y bajo 2 • Tolerancia de componente y sistema puede afectar los niveles finales y la linealidad de transición Control Regulador de Intensidad PE (Si aplica): • Ninguna conexión externa para regular la intensidad son requeridas cuando el Control Regulador de Intensidad PE de GE y el Receptáculo del Regulador de Intensidad PE de GE son usados. •Todas las conexiones de regulación de intensidad serán hechas entre el regulador de intensidad PE y la luminaria a través del receptáculo PE incluido. •Consulte las instrucciones incluidas en el Control Regulador de Intensidad PE de GE en cuanto a la configuración adecuada para el control regulador de intensidad. Sensor de Presencia (opcional): • El sensor de presencia programable se envía con un programa estándar el cual puede ser modificado usando el botón en el sensor. •El sensor tiene incluido un set de instrucciones de programación por separado. 5 MANTENIMIENTO/LIMPIEZA ADVERTENCIA Riesgo de descarga eléctrica: Desconecte la fuente de energía antes de dar mantenimiento. •Para mantener la alta eficiencia del lente, limpieza ocasional de la superficie exterior del lente puede ser necesaria y su frecuencia dependerá de las condiciones locales. •Use un detergente o jabón suave, con un pH neutro, no abrasivo y que no contenga hidrocarbonos aromatizantes o con cloro. • Lave a fondo, usando un paño suave. • Enjuague con agua fría y limpia y seque. 6 ALMACENAMIENTO • Antes de su instalación, las unidades no deben de • ser almacenadas a la intemperie solo en cajas (cajas de cartón) corrugadas. Todas las unidades deben de ser almacenadas en un área seca y cubierta hasta que sean instaladas. El área de almacenamiento no deberá de exceder -40°C (-40°F) a 50°C (122°F). -- Éste puede ser preferiblemente en un área techada o con una lona que proteja a las cajas corrugadas (cajas de cartón) contra el agua. Estas instrucciones no pretenden cubrir todos los detalles o variaciones de equipo, ni cada posible contingencia encontrada en conexión a la instalación, operación o mantenimiento. Si más información es requerida ó ciertos problemas particulares surgen, los cuales no son abarcados suficientemente para los requerimientos del comprador, el asunto debe de ser referido a GE Iluminación. GE Lighting • 1-888-MY-GE-LED (1 - 888 - 69 - 43 - 533) • www.gelighting.com GE Lighting es una subsidiaria de la Compañía General Electric. Evolve y la marca y logotipo de GE son marcas registradas de la Compañía General Electric. ©2014 GE Lighting. La información se encuentra sujeta a cambio sin previo aviso. Todos los valores son de diseño, o valores típicos al momento de ser medidos bajo condiciones de laboratorio. 35-201578-208 (Rev 09/09/14) Spanish