Evolve™ by GE Outdoor LED Fixtures

Transcription

Evolve™ by GE Outdoor LED Fixtures
Evolve™ by GE
Outdoor LED Fixtures
The GE Advantage™
Each EvolveTM by GE LED fixture comes complete
with GE service and support, every step of the way.
1
Discovery & Design
You receive a comprehensive, custom
lighting solution from a team who truly
listens to understand your specific goals.
2
Innovative Systems
You can choose from a broad
portfolio, including the latest
lighting technologies.
3
Seamless Distribution
You have easy and immediate
access through our national
network of distributors.
4
Integration Services
You garner coordination services with
a network of installers for your existing
infrastructure or new construction projects.
5
ROI Optimization
You see attractive financial benefits with
a plan built to deliver – we even assist
with utility rebate capture and propose
financing options from GE Capital.
MAKING MORE HISTORY
The EvolveTM by GE family of products is one of the most awarded in GE history. Honors include the
highly coveted Best-in-Class award, in two consecutive years, from the Next Generation Luminaires™ (NGL)
Solid-State Lighting Design Competition, the LIGHTFAIR® International innovation award,
and the Architectural SSL Product Innovation Award (PIA).
Our heritage and
expertise burns bright
in Evolve™ by GE.
Over 100 years ago, GE lit the first
streetlight. Fifty years later, a GE scientist
created the first visible LED. Today, we
offer the best of both worlds in our
multi-award winning Evolve™ by GE LED
fixtures – a family of roadway, street
and outdoor LED lighting fixtures
that’s taking “next generation”
to a whole new level.
Reimagining
the landscape
of outdoor
lighting.
Outdoor lighting is absolutely crucial to the security of our streets and public
places. And today, it has a lot to live up to: new legislation, environmental
challenges, requirements in energy reduction – just to name a few.
Nobody has more experience in outdoor lighting than GE. For more than a
century, we’ve been imagining better for our roadways, parking lots, garages,
residences and commercial areas. Better energy efficiency. Better aesthetics.
Less maintenance. You get it all with EvolveTM by GE.
4 | Evolve™ by GE Outdoor LED Fixtures
|5
Building better
solutions in
Hendersonville.
Get what you want faster
with responsive services.
We’ve all heard it before: You can have it fast,
or you can have it right. At GE Lighting, we
want our customers to have both. That’s
why we’ve integrated the highest standards
of quality testing into our engineering
process. And it’s why we’ve transformed our
Hendersonville, North Carolina, plant into a
short-cycle manufacturing center. Now, we
can move from order placement to product
shipping in as little as 10 days. Combine this
with our comprehensive distribution and
installation network, and you’ll have your
custom outdoor solutions up, running and
generating savings faster than ever before.
The complete package.
One provider.
When you choose GE, you’ll enjoy the benefits
of working with a single supplier for your
full outdoor LED lighting system. In addition
to convenience, you can be sure all parts and
pieces were designed to work together for
the highest performance.
6 | Evolve™ by GE Outdoor LED Fixtures
|7
Evolve by GE LED fixtures.
Imagination runs in the family.
TM
From roadways to parking lots, residential to retail, commercial properties to public places,
you’ll find your ideal lighting solution in the EvolveTM by GE portfolio. Efficiency and reliability
come standard in each fixture, and that’s just the beginning.
8 | Evolve™ by GE Outdoor LED Fixtures
Long life span
Reduced glare
EvolveTM by GE LED fixtures offer a
50,000-hour life rating, equaling more
than 11 years of service life based
on 12 hours of operation per day.
Revolutionary designs produce
safer, non-pixelated light with
low glare.
Minimal maintenance
Outstanding performance
– no matter the weather
Longer life span means less time
switching out lamps. Couple that
with easier installation and more reliable
engineering, and your maintenance
time is virtually eliminated.
Evolve by GE LED fixtures are built to
endure extreme weather hazards
and conditions. And, unlike other
outdoor options, these fixtures
perform even better in the cold.
Environmental responsibility
In addition to the built-in efficiency
benefits of LEDs, all Evolve by GE LED
fixtures are mercury- and lead-free.
|9
Evolve™ by GE
LED Roadway Lights
Combining the science of light and a historical
knowledge of roadway fixtures, GE engineers
have developed groundbreaking roadway lighting
solutions that are changing the way we light our
lanes. Advanced optical designs offer hundreds of
photometric options to meet your precise lighting
requirements, while delivering the built-in benefits
of all EvolveTM by GE LED fixtures and more.
Maximized efficient utilization of light (CU)
means less wasted light and more saved energy.
Low Wattage Streetlight (ERL)
The ideal LED solution for basic local and collector
roadway needs.
Scalable Project Grade Cobrahead (ERS1 & ERS2)
For local to major roadways, combine the aesthetic of
traditional roadway fixtures, the technical capabilities of
a sophisticated LED system, and the functional demands
of extreme weather hazards.
Increased control with stand-alone or wireless
control system options.
Simplified installation and maintenance with
easy-access doors for replacements or repairs, and
tool-less or single-tool entry for quicker connects.
More consistent light distribution through a
revolutionary optic design that focuses light on
the road, not in the eyes of drivers.
Optimized thermal management due to a robust
heat sink design, resulting in longer life, reduced
lumen depreciation and exceptional performance.
Scalable Specification Grade Cobrahead
(ERS1, ERS2, ERS3 & ERS4)
With hundreds of photometric options and lumen ranges
from 2,400 to 25,400, expect exceptionally controlled light
for any roadway.
Evolve LED Security Light (E2SA)
An energy-efficient, robust fixture designed
for outdoor work yards, roadside commercial
establishments, suburban developments
and rural areas.
C A S E I N P O I N T.
The city of Oakland, California, achieved
40% savings (over $1.4 million annually)
in energy and maintenance costs
with Evolve by GE Scalable Cobrahead
fixtures.
10 | Evolve™ by GE Outdoor LED Fixtures
Evolve™ by GE LED
Decorative Post Tops
For downtown spaces, commercial developments and residential communities, you’ll
find EvolveTM by GE LED Decorative Post Tops that offer more than their striking good looks.
In addition to improved horizontal and vertical uniformity, you can say goodbye to the
shadow circles commonly seen beneath other LED post top fixtures. And compared to HID,
Evolve by GE LED Decorative Post Tops can significantly reduce system energy.
Avery™ StreetDreams™
(EPAS)
Classic nostalgia
Salem (EPST)
Traditional
utility carriage
Contemporary Twin
Support (EPTC)
Distinct, trim styling
| 11
Evolve™ by GE LED Area Lights
EvolveTM by GE LED Area Lights provide reduced offsite visibility, as well as effective security light levels with
symmetric and asymmetric distributions. They can yield a significant reduction in system energy compared with
standard HID systems and virtually eliminate ongoing maintenance expenses.
Scalable Area Light (EAS)
Offers greater flexibility, style and scalability
for applications like commercial and medical
properties, strip malls and large malls, and
small, large and big box retailers.
N Series Area Light (EAN)
Delivers superior site uniformity and vertical
light distribution with mounting options
for both square and round poles. Matching
Wall Pack and Flood Light make it a cinch
to match the look of parking lots, building
façades, walkways and other areas.
Scalable Wall Pack (EWS)
A scalable solution for wall-mounted site,
area and general lighting applications. Can
reduce energy consumption considerably
compared to standard HID systems.
N Series Wall Pack (EWN)
Designed to efficiently illuminate walkways
and general areas; balances need for
scalability with workhorse performance.
12 | Evolve™ by GE Outdoor LED Fixtures
Evolve™ by GE LED Canopy Lights
Built to meet technical, functional and weather demands,
EvolveTM Canopy Lights are an ideal solution for canopy installations
(such as gas stations), or drive-thrus. The sleek new ECB fixture
offers quick and easy installation – just four screws.
ECB
ECR
Evolve by GE LED Parking Garage Lights
Enjoy significant energy and maintenance reduction, effective security light
levels, increased control and the instant-on capabilities needed to make
the most of parking areas. Our unique light-up version eliminates the
“cave effect” for a safer, more driver-friendly installation.
EGMS
EG2R
Evolve by GE LED Flood Lights
Flood Light (EFN)
Four mounting options fit virtually any flood application, including architectural wall
washing and façade lighting, sports court area lighting, flagpoles and bulletin/billboard
lighting. A unique photoelectric sensor receptacle can minimize control requirements
in dusk-to-dawn applications.
| 13
Reimagine your outdoor
lighting in three easy steps.
Lightin
g Audit
1. Request your FREE Lighting Audit from GE.
2. Receive your customized lighting solution.
3. Let GE coordinate the rest.
Backed by the GE Advantage ,
we will work with you to:
TM
Learn how to
save energy
and cut
spending
Support
environmental
initiatives
To learn more about municipal lighting solutions from GE or schedule your
complimentary Lighting Audit, visit gelighting.com/evolve.
Realize
a positive
return on
investment
Stars belong outside. And that’s just where
you’ll find EvolveTM by GE LED fixtures. From
roadways to residential neighborhoods,
parking lots to public spaces, Evolve by GE
outdoor LED lighting fixtures are redefining
the limits of high-quality, low-maintenance,
energy-efficient illumination. Welcome to
the next evolution of outdoor lighting.
Get ready to shine.
For more information or to get started,
contact your GE Lighting sales representative
or visit gelighting.com/evolve.
Information provided is subject to change without notice. All values are design
or typical values when measured under laboratory conditions, and GE makes no
warranty or guarantee, express or implied, that such performance will be obtained
under end-use conditions. Evolve™ is a registered trademark of GE. ©2015 GE.
© 2015 GE
OLP3077
08/2015
Printed in USA
GE
Lighting
Evolve LED Area Light
™
Scalable Area Light (EASC)
imagination at work
Product Features
The next evolution of the GE Evolve™ LED Area Light continues to deliver outstanding features, while adding greater
flexibility, style and scalability. This latest design offers higher lumen outputs and provides photometric combinations with
high efficacy, providing the ability to meet even a wider range of area lighting needs. Additionally, the new EASC Evolve
Luminaire comes with a specially designed auto dealership optic for exceptional illuminance on the dealership’s front row.
Optional programmable motion sensing for Title 24 compliance is available.
Applications
Mounting
• Site, area, and general lighting applications utilizing advanced LED optical system providing
high uniformity, excellent vertical light distribution, reduced offsite visibility, reduced on-site glare and effective security light levels.
• Ideal for small to large retailers, commercial to
medical properties, and big box retailers.
Option A
• 10-inch (254mm) mounting arm for square pole prewired with 24-inch (610mm) leads.
Option B
• 10-inch (254mm) mounting arm for round pole
prewired with 24-inch (610mm) leads.
Option C
• Slipfitter mounting for 2 3/8-inch (60mm) O.D. pipe prewired with 24-inch (610mm) leads.
Option D
• 10-inch (254mm) mounting arm for round or
square pole prewired with 24-inch (610mm) leads.
Option S
• Knuckle Slipfitter mounting for 2.3-3” O.D. pipe,
pre-wired with 24-inch (610mm) leads.
Housing
• Die-cast aluminum housing.
• Slim architectural design incorporates an integral
heat sink and light engine, ensuring maximum heat transfer, long LED life, and a reduced Effective Projected Area (EPA).
• Meets 3G vibration standards per ANSI C136.31-2010.
LED & Optical Assembly
Finish
• Structured LED arrays for optimized area light
photometric distribution.
• Evolve light engine with directional reflectors designed to optimize application efficiency and minimize glare.
• Utilizes high brightness LEDs, 70 CRI at 4000K
and 5000K typical.
•
•
•
Lumen Maintenance
• 120-277 volt and 347-480 volt available.
• System power factor is >90% and THD <20%.*
• Class “A” sound rating.
• Photo electric sensors (PE) available for all voltages.
• ANSI C136.41 dimmable PE receptacle is available making the unit “adaptive controls ready.”
• Surge Protection Options:
For 120-277VAC and 347-480VAC per IEEE/ANSI C136.2-2015.
– 6kV/3kA “Basic” surge protection, standard.
– 10kV/5kA “Enhanced” surge protection available
with R option.
Lumen Maintenance (25°C Ambient)
Optical
Code
L5, V5, L4, L3, L2
LA
All others
Calculated
50,000 hr 100,000 hr
0.98
0.90
0.99
Calculated Hours
L90
L70
0.95>100,000 >100,000
0.81>100,000 49,000
0.97>100,000 >100,000
Lumen Maintenance per IES TM-21.
Ratings
•
listed, suitable for wet locations.
•
listed with option code “J” SKUs.
• IP65 rated optical enclosure per ANSI C136.25-2009.
• Temperature rated at –40° to 50°C (–40° to 35°C
for fixtures over 390 watts).
• Upward Light Output Ratio (ULOR) = 0.
• Title 24 compliant with “H” motion sensor option.
• Compliant with the material restriction
requirements of RoHS.
Corrosion resistant polyester powder painted,
minimum 2.0 mil. thickness.
Standard colors: Black & Dark Bronze.
RAL & custom colors available.
Electrical
* System power factor and THD is tested and specified
at 120V input and maximum load conditions.
Ordering Number Logic
Evolve™ LED Scalable Area Light (EASC)
E
_ _A _S
C
_
_
PROD. ID PHOTOMETRIC
VOLTAGE
_
OPTICAL DISTRIBUTION
ORIENTATION
CODE
E= Evolve C= Photometric 0 = 120 - 277
Series
1 = 120*
A= Area
2 = 208*
3 = 240*
S= Scalable
4 = 277*
5 = 480*
D = 347*
H = 347-480
F = Front
L = Left
R = Right
N = Not
Applicable
_
__
DRIVE
CURRENT
LED COLOR
TEMP
5 = 525mA 40 = 4000K
7 = 700mA* 50 = 5000K
* Only select
for product
395W or greater.
Light pattern
thrown in direction
specified in relation
to Pole and Fixture.
*Specify single
voltage if fuse
option is selected.
Pole
Front (F)
Pole
Left (L)
TYPE V
TYPE IV
TYPE III
TYPE II
OPTICAL
CODE
TYPE
D5
E5
F5
G5
H5
J5
K5
L5
N5
P5
Q5
R5
S5
T5
U5
V5
A4
B4
C4
D4
E4
F4
G4
H4
J4
K4
L4
A3
B3
C3
D3
E3
F3
G3
H3
J3
K3
L3
A2
B2
C2
D2
E2
F2
G2
H2
J2
K2
L2
KA
LA
Symmetric Medium
Symmetric Medium
Symmetric Medium
Symmetric Medium
Symmetric Medium
Symmetric Medium
Symmetric Medium
Symmetric Medium
Symmetric Short
Symmetric Short
Symmetric Short
Symmetric Short
Symmetric Short
Symmetric Short
Symmetric Short
Symmetric Short
Asymmetric Forward
Asymmetric Forward
Asymmetric Forward
Asymmetric Forward
Asymmetric Forward
Asymmetric Forward
Asymmetric Forward
Asymmetric Forward
Asymmetric Forward
Asymmetric Forward
Asymmetric Forward
Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Wide Asymmetric Narrow
Asymmetric Narrow
Asymmetric Narrow
Asymmetric Narrow
Asymmetric Narrow
Asymmetric Narrow
Asymmetric Narrow
Asymmetric Narrow
Asymmetric Narrow
Asymmetric Narrow
Asymmetric Narrow
Asymmetric 100° Wide Auto
Asymmetric 100° Wide Auto
Not Applicable
(N)
TYPICAL INITIAL
LUMENS
TYPICAL SYSTEM
WATTAGE
4000K & 5000K
120-277V & 347-480V
8300
12700
15000
17100
21200
25200
30000
38000
9200
13800
16400
18700
23100
27400
33000
41500
4200
6500
7600
8700
12900
15400
17100
21200
25200
30000
38300
4700
7100
8300
9500
13900
16800
18700
23100
27400
33000
41500
4600
6800
8000
9100
13400
16200
18000
22300
26500
31900
40000
35400
46900
PE FUNCTION
_
____
___
MOUNTING
ARM
COLOR
OPTIONS
BLCK = Black
A=10” Arm for
DKBZ = Dark Bronze
Square Pole
supplied with leads GRAY = Gray
WHTE= White
B = 10” Arm for
Round Pole
supplied with leads Contact manufacturer
for other colors.
C = EXT Slip-fitter
2” Pipe (2.378 in. OD)
supplied with leads
D = 10” Arm for round or square poles, supplied with leads and
additional hardware
S = Knuckle Slipfitter ** PE control not
for 2.3 in. - 3.0 in. OD available for 347-480V. Tenon, supplied with Must be a discrete
voltage (347V or 480V). leads. 0-45° vertical † When ordering PE
aiming angles
function socket A-D,
achievable.
1= None
2= PE Rec.
4 = PE Rec. with Shorting Cap
5 = PE Rec. with Control **
A = ANSI C136.41 7-pin dimming PE
Receptacle †#
D = ANSI C136.41 7-pin dimming PE
Receptacle with
Shorting Cap †#
a dimming driver must also be ordered under the “OPTIONS” column.
# Order Dimming/Control PE as a separate item.
Pole
Pole
Right (R)
_
DISTRIBUTION
ORIENTATION
AVAILABLE
82
119
137
156
199
235
283
395
82
119
137
156
199
235
283
395
44
62
72
82
119
144
156
199
235
283
395
44
62
72
82
119
144
156
199
235
283
395
44
62
72
82
119
144
156
199
235
283
395
283
398
*Rating values for B and G are based on rated lumens and may vary due to flux tolerances.
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
F, L, R
C = IEC
D =Dimming
(0-10 Volt Input) †
F =Fusing
H = Motion Sensor **#
J = cUL/Canada
R = 10kV Extra Surge
Protection
XXX = Special Options
† Dimming leads will be
provided through the back
of the arm, unless specified
with A or D PE Function.
** When ordering Motion
Sensing Option H - “A” or “B”
Mounting Arm must be selected.
Fixture power increase of 1W
expected with sensor use.
# Dimming is standard
with H option code. Do
not also select D option.
Not compatible with PE
receptacle options A, or D.
BUG RATING*
4000K & 5000K
IES FILE NUMBER
B
U
G
4000K
3
4
4
4
4
5
5
5
3
3
4
4
4
4
5
5
1
1
1
1
2
2
2
3
3
3
3
1
1
1
2
2
2
2
3
3
3
3
1
1
2
2
2
3
3
3
3
3
4
4
5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
2
2
2
2
3
3
4
1
2
2
2
2
2
2
3
1
2
2
2
3
3
3
4
4
5
5
1
1
2
2
2
2
2
3
3
4
4
1
1
2
2
2
3
3
3
3
4
4
3
4
EASC_D5N540______.IES
EASC_E5N540______.IES
EASC_F5N540______.IES
EASC_G5N540______.IES
EASC_H5N540______.IES
EASC_J5N540______.IES
EASC_K5N540______.IES
EASC_L5N740______.IES
EASC_N5N540______.IES
EASC_P5N540______.IES
EASC_Q5N540______.IES
EASC_R5N540______.IES
EASC_S5N540______.IES
EASC_T5N540______.IES
EASC_U5N540______.IES
EASC_V5N740______.IES
EASC_A4F540______.IES
EASC_B4F540______.IES
EASC_C4F540______.IES
EASC_D4F540______.IES
EASC_E4F540______.IES
EASC_F4F540______.IES
EASC_G4F540______.IES
EASC_H4F540______.IES
EASC_J4F540______.IES
EASC_K4F540______.IES
EASC_L4F740______.IES
EASC_A3F540______.IES
EASC_B3F540______.IES
EASC_C3F540______.IES
EASC_D3F540______.IES
EASC_E3F540______.IES
EASC_F3F540______.IES
EASC_G3F540______.IES
EASC_H3F540______.IES
EASC_J3F540______.IES
EASC_K3F540______.IES
EASC_L3F740______.IES
EASC_A2F540______.IES
EASC_B2F540______.IES
EASC_C2F540______.IES
EASC_D2F540______.IES
EASC_E2F540______.IES
EASC_F2F540______.IES
EASC_G2F540______.IES
EASC_H2F540______.IES
EASC_J2F540______.IES
EASC_K2F540______.IES
EASC_L2F740______.IES
EASC_KAF540______.IES
EASC_LAF740______.IES
5000K
EASC_D5N550______.IES
EASC_E5N550______.IES
EASC_F5N550______.IES
EASC_G5N550______.IES
EASC_H5N550______.IES
EASC_J5N550______.IES
EASC_K5N550______.IES
EASC_L5N750______.IES
EASC_N5N550______.IES
EASC_P5N550______.IES
EASC_Q5N550______.IES
EASC_R5N550______.IES
EASC_S5N550______.IES
EASC_T5N550______.IES
EASC_U5N550______.IES
EASC_V5N750______.IES
EASC_A4F550______.IES
EASC_B4F550______.IES
EASC_C4F550______.IES
EASC_D4F550______.IES
EASC_E4F550______.IES
EASC_F4F550______.IES
EASC_G4F550______.IES
EASC_H4F550______.IES
EASC_J4F550______.IES
EASC_K4F550______.IES
EASC_L4F750______.IES
EASC_A3F550______.IES
EASC_B3F550______.IES
EASC_C3F550______.IES
EASC_D3F550______.IES
EASC_E3F550______.IES
EASC_F3F550______.IES
EASC_G3F550______.IES
EASC_H3F550______.IES
EASC_J3F550______.IES
EASC_K3F550______.IES
EASC_L3F750______.IES
EASC_A2F550______.IES
EASC_B2F550______.IES
EASC_C2F550______.IES
EASC_D2F550______.IES
EASC_E2F550______.IES
EASC_F2F550______.IES
EASC_G2F550______.IES
EASC_H2F550______.IES
EASC_J2F550______.IES
EASC_K2F550______.IES
EASC_L2F750______.IES
EASC_KAF550______.IES
EASC_LAF750______.IES
Photometrics
EASC Type V - Symmetric Short (U5)
33,000 Lumens, 5000K (EASC_U5N550__.ies)
EASC Type V - Symmetric Medium (K5)
30,000 Lumens, 5000K (EASC_K5N550__.ies)
10716
11631
8037
8723
5358
5815
2
2679
.2
.5
1
.1 .2
.1
Grid Distance in Units
of Mounting Height at 40’ Initial
Footcandle Values at Grade
Vertical plane through horizontal angle
of maximum candlepower at 45°
Vertical plane through horizontal angle of 72°
EASC Type IV - Asymmetric Forward (K4)
30,000 Lumens, 5000K (EASC_K4F550__.ies)
.5
1
Grid Distance in Units of
Mounting Height at 40’ Initial
Footcandle Values at Grade
Vertical plane through horizontal angle
of maximum candlepower at 20°
Vertical plane through horizontal angle of 52°
EASC Type IV - Asymmetric Forward (E4)
12,900 Lumens, 5000K (EASC_E4F550__.ies)
21110
9077
15832
6808
10555
.2
2
2908
4539
.1
2
.2
5277
.1
.5
.5
2269
1
Grid Distance in Units of
Mounting Height at 40’ Initial
Footcandle Values at Grade
Vertical plane through horizontal angle
of maximum candlepower at 45°
Vertical plane through horizontal angle of 72°
22807
9607
17105
7205
11404
.2 .1
4803
2
5702
.5
.2 .1
1
Vertical plane through horizontal angle
of maximum candlepower at 20°
Vertical plane through horizontal angle of 52°
EASC Type II - Asymmetric Narrow (K2)
31,900 Lumens, 5000K (EASC_K2F550__.ies)
.1
.2
.5
Grid Distance in Units of
Mounting Height at 30’ Initial
Footcandle Values at Grade
Vertical plane through horizontal angle
of maximum candlepower at 20°
Vertical plane through horizontal angle of 52°
EASC Type II - Asymmetric Narrow (E2)
13,400 Lumens, 5000K (EASC_E2F550__.ies)
19313
8113
14485
6085
.1
.2
9657
4828
.5
2
Vertical plane through horizontal angle
of maximum candlepower at 65°
Vertical plane through horizontal angle of 60°
4056
2028
1
Grid Distance in Units of
Mounting Height at 40’ Initial
Footcandle Values at Grade
2
2402
1
Grid Distance in Units of
Mounting Height at 40’ Initial
Footcandle Values at Grade
Vertical plane through horizontal angle
of maximum candlepower at 45°
Vertical plane through horizontal angle of 72°
EASC Type III - Asymmetric Wide (E3)
13,900 Lumens, 5000K (EASC_E3F550__.ies)
EASC Type III - Asymmetric Wide (K3)
33,000 Lumens, 5000K (EASC_K3F550__.ies)
.5
Grid Distance in Units of
Mounting Height at 30’ Initial
Footcandle Values at Grade
2
1
Grid Distance in Units of
Mounting Height at 30’ Initial
Footcandle Values at Grade
Vertical plane through horizontal angle
of maximum candlepower at 65°
Vertical plane through horizontal angle of 60°
Photometrics
EASC Type II - Assymetric Auto (KA)
35,400 Lumens, 5000K (EASC_KAF550__.ies)
12923
17121
9692
12841
2
6462
.5
.2
EASC Type II - Assymetric Auto (LA)
46,900 Lumens, 5000K (EASC_LAF750__.ies)
3231
.1
.5 .2 .1
1
Grid Distance in Units
of Mounting Height at 40’ Initial
Footcandle Values at Grade
Vertical plane through horizontal angle
of maximum candlepower at 0°
Vertical plane through horizontal angle of 37°
2
8561
4280
1
Grid Distance in Units
of Mounting Height at 40’ Initial
Footcandle Values at Grade
Vertical plane through horizontal angle
of maximum candlepower at 0°
Vertical plane through horizontal angle of 37°
H-Motion Sensing Option:
• Intended for high mounting applications, between 15-30ft
(4.57-9.14m). For mounting heights exceeding 30ft, pole mounted sensors are recommended.
• Provides a coverage area radius for walking motion of 15-20ft
(4.57-6.10m).
• Provides 270° of coverage (~90° is blocked by the pole).
• Comes standard with 50% dimmed light output with no occupancy, and full power at occupancy.
• Comes standard with photocell function. Note: It is not necessary to also purchase PE receptacle or control.
• Comes standard with a 5 minute occupancy time delay and a 5 minute ramp-down to the 50% dimmed level.
• Must order with decorative mounting arm options “A” or “B”.
• Fixture power increase of 1W expected with sensor use.
Note: Standard options may be reprogrammed in the field. Reprogramming instructions included in product shipment.
Sensor Pattern:
20’
10’
20’
10’
10’
10’
20’
Sensing Pattern Area Fixture
Up to 30 ft.
20’
Product Dimensions
(Option A) 10” Arm for Square Pole Mount
(Option B) 10” Arm for Round Pole Mount
(Option D) 10” Arm for Square Pole Mount or Round Pole Mount
Option D includes all mounting hardware in Option A and Option B
34.5 in.
[878 mm]
10.9 in.
[277 mm]
Square Pole
16.9 in.
[430 mm]
16.0 in.
[406 mm]
10.5 in.
[266 mm]
34.1 in.
[867 mm]
Round Pole
TOP VIEW
Square Pole Adaptor (A and D)
Round Pole Arm (B and D)
3.5 inch - 4.5 inch OD Pole
(89 mm OD - 115 mm OD)
4.7 in.
2.5 in. [119 mm]
[63 mm]
4.4 in.
8.4 in.
[213 mm] [111 mm]
R8.680 in.
[R220 mm]
FRONT VIEW
SIDE VIEW
0.438 in.
[11 mm]
4.392 in.
[112 mm]
1.711 in.
[43 mm]
2.125 in.
[54 mm]
0.625 in.
[16 mm]
2.008 in.
[51 mm]
3.188 in. 4.250 in.
[81 mm] [108 mm] 5.438 in.
[138 mm]
6.375 in. 4.812 in.
[162 mm] [162 mm]
1.312 in.
[33 mm]
0.438 in.
[11 mm]
BACK VIEW
Option B and D Round Pole
3.5 inch - 4.5 inch OD Pole
(89 mm OD - 115 mm OD)
D ATA
BACK VIEW
Option A and D Square Pole
3.5 inch - 4.5 inch Pole
(89 mm - 115 mm)
• Approximate net weight: 43-47 lbs (19.50 - 21.32 kgs)
Contact manufacturer for specific configuration weight.
• Effective Projected Area (EPA) with 10” Mounting Arm: 0.97 sq ft max (0.09 sq m)
Product Dimensions
(Option C) Slipfitter Arm Mount
28.6 in.
[726 mm]
5.0 in.
[126 mm]
16.9 in.
[430 mm]
16.0 in.
[406 mm]
TOP VIEW
2 in. Nominal PIPE ONLY
(2.375 in. OD)
[60 mm OD]
2 in. Nominal PIPE ONLY
(2.375 in. OD)
[60 mm OD]
4.7 in.
2.5 in. [119 mm]
[63 mm]
4.9 in.
[125 mm]
R8.680 in.
[R220 mm]
D ATA
BACK VIEW
SIDE VIEW
FRONT VIEW
• Approximate net weight: 41-45 lbs (18.60 - 20.41 kgs)
Contact manufacturer for specific configuration weight.
• Effective Projected Area (EPA) with Slipfitter: 0.47 sq ft max (0.04 sq m)
(Option S) Knuckle Arm Mount
3.2 in.
[81 mm]
26.8 in.
[681 mm]
16.9 in.
[430 mm]
16.0 in.
[406 mm]
KNUCKLE SLIPFITTER ARM MOUNT
0° TO 45° AIMING RANGE
TOP VIEW
3 inch OD (max)
[76 mm OD]
2.3 in.
[57 mm]
7.3 in.
[186 mm]
D ATA
BACK VIEW
45° max upward aim
5.0 in.
2.5 in. [127 mm]
[63 mm]
R26.9 in.
[R683 mm]
SIDE VIEW
FRONT VIEW
• Approximate net weight: 41-45 lbs (18.60 - 20.41 kgs)
Contact manufacturer for specific configuration weight.
• Effective Projected Area (EPA) with fixture mounted at 45° upward: 1.97 sq ft max
Mounting Information
Mounting Arms for Slipfitter
Order separately with Mounting Option C (External Slipfitter)
SQUARE POLE MOUNTING ARM
3.5 TO 4.5-inch (89 to 114mm) SQUARE
(WILL ALLOW 4 FIXTURES PER POLE @ 90 DEGREES.)
10
.
[26 500 i
7 m n.
m]
Drilling Templates for
Slipfitter Arms & Arm Mount
SQUARE POLE MOUNTING
.312 in. DIA.
[8 mm DIA.]
5.250 in.
[133 mm
MIN.] 1.812 in.
[46 mm]
.438 in. DIA.
[11 mm DIA.]
(2 Places)
2.196 in.
[56 mm]
4.392 in.
[112 mm]
1.250 in. DIA.
[32 mm DIA.]
Hole
.656 in. [17 mm]
1.312 in. [33 mm]
ORDER SEPARATELY FROM FIXTURE AS CATALOG NUMBER
SPA-EAMT10BLCK “Black”
SPA-EAMT10DKBZ “Dark Bronze”
ROUND POLE MOUNTING ARM
ROUND POLE MOUNTING
3.5 TO 4.5-inch (89 to 114mm) OD
(WILL ALLOW 4 FIXTURES PER POLE @ 90 DEGREES.)
3.5 TO 4.5-inch (89 to 114mm) OD
round pole mounting arm
10
.
[26 500 i
7 m n.
m]
.312 in. DIA.
[8 mm DIA.]
5.250 in.
[133 mm
MIN.] 1.812 in.
[46 mm]
.750 in. DIA.
[19 mm DIA.]
Hole
.438 in. DIA.
[11 mm DIA.]
(2 Places)
2.719 in.
[69 mm]
5.438 in.
[138 mm]
ORDER SEPARATELY FROM FIXTURE AS CATALOG NUMBER
RPA-EAMT10BLCK “Black”
RPA-EAMT10DKBZ “Dark Bronze”
Wall Mounting Bracket Adapter Plate
ORDER SEPERATELY FROM FIXTURE AS CATALOG NUMBER
WMB-EAMT06
*NOTE: For Wall Mounting, order luminaire with mounting arm: C = EXT Slip-fitter 2” Pipe (2.378 in. OD) supplied with leads.
Other mounting patterns are available for retrofit installations.
Contact manufacturing for other available mounting patterns.
www.gelighting.com
GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property
of their respective owners. Information provided is subject to change without notice. All values are design or typical
values when measured under laboratory conditions. GE Lighting is a business of the General Electric Company.
© 2016 GE.
OLP3090 (Rev 02/22/16)
GE
Lighting
Evolve LED Area Light
™
Shielding for EAS Area Light Fixtures
The next evolution of the GE Evolve™ LED Area Light delivers even better trespass control. GE’s exclusive reflective optical
ring design produces superior vertical illuminace and efficiently directs the light without wasteful and unwelcomed light
spill into neighboring properties. Due to the extensive variation of parking lot configurations coupled with tightening
ordinances, GE now offers a full array of shielding to accommodate challenging sites.
The shielding options available for the GE Evolve Area Light focus on the following applications:
• Left and Right cutoff
• Front cutoff
• Backlight control and B-U-G improvement
Within each of the shielding families, there are multiple shielding cutoff levels that are categorized in mounting height (MH)
increments. GE accommodates cutoff distance from the pole from 1MH to 2.5 MH in 0.5 MH increments. The shields that
are listed are for the most common applications. Please contact the manufacturer if your need is not listed.
MH
1 MH
2.5 MH
All shields can be installed easily in the field. The next evolution of the GE Evolve LED Area Light and shielding options will
help you meet any parking lot challenge.
imagination at work
EAS Shielded Fixture Examples
Single Module Left/Right Shield
Double Module Left/Right Shield
Single Module Front Shield
Double Module Front Shield
Single Module Back Shield
Double Module Back Shield
Type V Shielding
Shield
Orientation
Any Side
Any Side
Cutoff
Distance
Fixture
Type
0.5
1
1.5
2 Module
2
2.5
0.5
1
1.5
2 Module
2
2.5
Shield Order
Logic
ELS-EASX-MS1-BLCK
ELS-EASX-MS2-BLCK
ELS-EASX-MS3-BLCK
ELS-EASX-MS4-BLCK
ELS-EASX-MS5-BLCK
ELS-EASX-SS1-BLCK
ELS-EASX-SS2-BLCK
ELS-EASX-SS3-BLCK
ELS-EASX-SS4-BLCK
ELS-EASX-SS5-BLCK
Type IV Shielding
Shield
Orientation
Cutoff
Distance
Fixture
Type
Shield Order
Logic
1
ELS-EASX-FF2-BLCK
1.5
ELS-EASX-FF3-BLCK
Front
2 Module
2
ELS-EASX-FF4-BLCK
2.5
ELS-EASX-FF5-BLCK
1
ELS-EASX-RF2-BLCK
1.5
ELS-EASX-RF3-BLCK
Front
1 Module
2
ELS-EASX-RF4-BLCK
2.5
ELS-EASX-RF5-BLCK
0.5
ELS-EASX-FS1-BLCK
1
ELS-EASX-FS2-BLCK
Side
1.5
2 Module
ELS-EASX-FS3-BLCK
2
ELS-EASX-FS4-BLCK
2.5
ELS-EASX-FS5-BLCK
0.5
ELS-EASX-RS1-BLCK
1
ELS-EASX-RS2-BLCK
Side
1.5
1 Module
ELS-EASX-RS3-BLCK
2
ELS-EASX-RS4-BLCK
2.5
ELS-EASX-RS5-BLCK
Backshort2 ModuleELS-EASX-FBN-BLCK
long
ELS-EASX-FBL-BLCK
Back
long
1 Module
ELS-EASX-RBL-BLCK
Type III Shielding
Shield
Orientation
Cutoff
Distance
Fixture
Type
Shield Order
Logic
1
ELS-EASX-WF2-BLCK
1.5
ELS-EASX-WF3-BLCK
Front
2 Module
2
ELS-EASX-WF4-BLCK
2.5
ELS-EASX-WF5-BLCK
1
ELS-EASX-DF2-BLCK
1.5
ELS-EASX-DF3-BLCK
Front
1 Module
2
ELS-EASX-DF4-BLCK
2.5
ELS-EASX-DF5-BLCK
0.5
ELS-EASX-WS1-BLCK
1
ELS-EASX-WS2-BLCK
Side
1.5
2 Module
ELS-EASX-WS3-BLCK
2
ELS-EASX-WS4-BLCK
2.5
ELS-EASX-WS5-BLCK
0.5
ELS-EASX-DS1-BLCK
1
ELS-EASX-DS2-BLCK
Side
1.5
1 Module
ELS-EASX-DS3-BLCK
2
ELS-EASX-DS4-BLCK
2.5
ELS-EASX-DS5-BLCK
Backshort2 ModuleELS-EASX-WBN-BLCK
long
ELS-EASX-WBL-BLCK
Back
long
1 Module
ELS-EASX-DBL-BLCK
Type II Shielding
Shield
Orientation
Cutoff
Distance
Fixture
Type
Shield Order
Logic
0.5
ELS-EASX-NS1-BLCK
1
ELS-EASX-NS2-BLCK
Side
1.5
2 Module
ELS-EASX-NS3-BLCK
2
ELS-EASX-NS4-BLCK
2.5
ELS-EASX-NS5-BLCK
0.5
ELS-EASX-AS1-BLCK
1
ELS-EASX-AS2-BLCK
Side
1.5
1 Module
ELS-EASX-AS3-BLCK
2
ELS-EASX-AS4-BLCK
2.5
ELS-EASX-AS5-BLCK
short
ELS-EASX-NBN-BLCK
Back
2 Module
long
ELS-EASX-NBL-BLCK
Back
long
1 Module
ELS-EASX-ABL-BLCK
www.gelighting.com
GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property
of their respective owners. Information provided is subject to change without notice. All values are design or typical
values when measured under laboratory conditions. GE Lighting and GE Lighting Solutions, LLC are businesses of
the General Electric Company. © 2015 GE.
OLP3083 (Rev 06/08/15)
GE
Installation Guide
GEH-6016B
Lighting
Evolve LED Area Light
™
Scalable Fixture (EAS)
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
Save these instructions for future use.
WARNING
Risk of electrical shock. Disconnect power before servicing
or installing product.
WARNING
Risk of injury or damage. Unit will fall if not installed
­properly. Follow installation instructions.
CAUTION
Risk of injury. Wear safety glasses and gloves during
­installation and servicing.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the ­following two conditions: (1) This device may not cause
harmful ­interference, and (2) this device must accept any interference
received, ­including interference that may cause undesired operation.
This Class [A] RFLD complies with the ­Canadian standard ICES-003.
Ce DEFR de la classe [ A ] est conforme à la NMB-003 du ­Canada.
Note: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are ­designed to provide reasonable protection against
harmful ­interference when the equipment is operated in a ­commercial
­environment. This equipment ­generates, uses, and can radiate ­radio
frequency energy and, if not installed and used in a­ ccordance with
the instruction manual, may cause harmful interference to radio
­communications. Operation of this equipment in a residential area
is likely to cause harmful ­interference in which case the user will be
required to correct the i­nterference at his own expense.
imagination at work
• This luminaire is designed for outdoor lighting service, and should not be used in areas of limited ventilation, or in high ambient temperatures.
• Best results will be ­obtained if installed and m
­ aintained according to the ­following ­recommendations. ­
•
Luminaire is designed to operate in ambient ­
temperatures ranging from -40°C to 50°C
(-40°C to 35°C for >400W) and to be mounted ­
horizontally to a vertical pole with LEDs facing down, ­
or aimed up to 45° upward with a Knuckle slip fitter.
SPECIFICATIONS
•
•
•
Weight: Maximum weight <50 lbs (22.68 kg)
EPA: Horizontal mounting: 0.97 sq ft max (0.09 sq M)
45° mounting: 1.97 sq ft max (0.18 sq M)
IP Rating: Optical 65, Standard Electrical Enclosure:
UL 1598 Wet Location Rated
1
UNPACKING
3b Round Pole Architectural Arm Mounting
• This luminaire has been properly packed so that no parts should have been damaged during transit.
• Inspect to confirm.
2
HANDLING
• Damage may occur if luminaire is improperly handled outside of pack.
• Do not impact or stack luminaire after removal from packaging.
3
This luminaire has been configured specifically to mount
to round pole 3.5-4.5 inches (89-114mm) in diameter. Hole
pattern on round pole shall be in ­accordance with Figure 2.
• Place fixture against pole.
• Install 3/8 bolt, lock washer and washer in top as shown and tighten into nut plate.
• Open arm door and install 3/8 bolt, lock washer and washer inside arm as shown and tighten into nut plate. (See Figure 3 and 4)
• Torque top and bottom bolts to 25 - 32 ft-lbs (34-43 N-m).
• Inspect installation to ensure fixture is secure.
WARNING
MOUNTING
Under no conditions should architectural a
­ rm mounting bolts
be torqued to greater than 32 ft-lbs. (43 N-m)
WARNING
DRILLING TEMPLATE
ROUND POLE MOUNTING
3.5 to 4.5 inch (89 to 114mm) OD
round pole mounting arm.
Risk of injury or damage. Unit will fall if not installed
­properly. Follow installation instructions.
Follow the appropriate installation instructions based on
your selected mounting method:
a. Slipfitter Mounting
b. Round Pole Architectural Arm Mounting
c. Square Pole Architectural Arm Mounting
d. Knuckle Slipfitter for 2 3/8 in. (60mm) OD Tenon (0 to 45°
vertical aiming angle)
3a Slipfitter Mounting
This luminaire has been configured specifically to mount to a
2-inch pipe brackets (2-3/8” OD).
•
•
•
Hold luminaire approximately level with pipe. Pull wires through arm and place slip fitter over 2-inch (51mm) pipe (2 3/8-inch (60mm) OD).
Tighten the (4) slipfitter 3/8 bolts to 10-14 ft-lbs
(14-19 N-m). Tighten jam nuts after bolts have been tightened. (See Figure 1)
Inspect installation to ensure fixture is secure.
WARNING
Under no conditions should slipfitter bolts be torqued to a
level greater than 14 foot pounds (19 N-m).
.312 in. DIA.
(8 mm DIA.)
5.2500 in.
(133 mm)
(MIN.)
.438 in. DIA.
(11 mm DIA.)
(2 PLACES)
1.8120 in.
(46 mm)
2.7190 in.
(69 mm)
.750 in. DIA.
(19 mm DIA.)
(HOLE)
FIGURE 2
Torque Top Bolt
to 25-32 ft-lbs.
(34-43N-m)
Door
Torque Bottom Bolt
to 25-32 ft-lbs.
(34-43N-m)
Arm Door Screw
FIGURE 3
Section view: Round Pole Mounting
Architectural Arm with Door
Slipfitter 3/8 Bolts and Jam Nuts
Pole
Nut Plate
FIGURE 1
Bolt, Lock Washer,
Flat Washer
Arm Door Screw
FIGURE 4
5.4380 in.
(138 mm)
3c Square Pole Architectural Arm Mounting
FIXTURE ARM TO ARM ADAPTER
Torque Top Bolt
to 25 - 32 ft-lbs.
(34-43 N-m)
This luminaire has been configured the same as 3b
and an adapter plate has been included to mount to
a square pole. Hole pattern on square pole shall be in
­accordance with Figure 5.
• Orient adapter block so that oval shaped through hole is closer to top than bottom of adapter.
• With adapter block end oriented properly, mount adapter block to pole with the nut plate and 3/8-16 bolts and washer supplied as shown. Torque 3/8-16 bolts to 25 - 32ft-lbs (34-43 N-m). (See Figure 6)
• Place fixture against adapter block.
• Install 3/8 bolt, lock washer and washer in top as shown and tighten into adapter block.
(See Figure 7)
• Open arm door and Install 3/8 bolt into tapped hole of adapter block. (See Figure 7)
• Torque top and bottom bolts to 25 - 32 ft-lbs (34-43 N-m).
• Inspect installation to ensure fixture is secure.
DRILLING TEMPLATE
SQUARE POLE MOUNTING
.312 in. DIA.
(8 mm DIA.)
5.2500 in.
(133 mm)
(MIN.)
1.8120 in.
(46 mm)
.438 in. DIA.
(11 mm DIA.)
(2 PLACES)
2.1960 in.
(56 mm)
4.3920 in.
(112 mm)
1.250 in. DIA.
(32 mm DIA.)
(HOLE)
Torque Bottom Bolt
to 25 - 32 ft-lbs.
(34-43 N-m)
FIGURE 7
3d Knuckle Slipfitter for 2-3/8 in. (60mm) to 3.0 in.
(76mm) OD Tenon
This luminaire has been configured specifically to provide
0 to 45° vertical aiming in 5° increments and mount on
2-3/8-inch O.D. (73mm) through 3-inch O.D. (76mm) pipe.
•
•
•
•
Place slipfitter on the tenon.
Three set screws are used to clamp the floodlight securely to the pipe. Tighten set screws to 18-22 foot pounds (24-30 N-m).
To aim the luminaire, loosen the knuckle bolt, adjust the aim 0 to 45° , and tighten to 45-50 ft-lbs (61-68 N-m).
Inspect installation to ensure fixture is secure.
26.776 in.
[680 mm]
2.3 in.
[57 mm]
45° max upward aim
.656 in. (17 mm)
1.312 in. (33 mm)
FIGURE 5
5.0 in.
[127 mm]
7.3 in.
[186 mm]
R26.9 in.
[R683 mm]
Tighten Knuckle Bolt
to 45-50 Foot Pounds
3.805 in.
[97 mm]
ADAPTER PLATE FOR
SQUARE POLE
2-3/8 in. (60mm) to 3.0 in. (76mm) OD only
Tighten 3 Set Screws to 18-22
Foot Pounds
Nut Plate
Adapter Block
4
WIRING
CAUTION
Risk of Damage or Injury: Door should be closed with
screw until fixture in final location.
3/8-16 Washer and Bolts
Torque Bolts to 25 - 32ft-lbs.
(34-43 N-m)
FIGURE 6
• NOTE: Make all electrical connections in accordance with the National ­Electrical Code and any applicable ­
local code requirements.
• Strain relief for incoming power must be p
­ rovided in the pole top by the customer.
• Supply Wire Type and Size, for Customer Connection to Terminal Board: 16 AWG (1.5mm2) to 6 AWG (10mm2) Solid or Stranded.
Terminal Board Connections:
Terminal Board Position
Supply Type
L1
High Line
G
Ground
N/L2
Low Line/Neutral
• NOTE: Verify that supply voltage is correct by ­
comparing it to nameplate inside door or on carton.
Photoelectric Control:
• (If option present)—Photoelectric control receptacle should be oriented before control is installed.
• Loosen the two holding screws and rotate receptacle until “North” is directed as near as possible to true North.
• Verify that the grommet under the PE receptacle is seated and that there are no gaps that will allow water to enter the fixture from under the PE ­
receptacle.
• Tighten ­holding screws and install control.
Electrical Connection:
•
•
•
•
•
Connect Luminaire wire leads to supply wire. ­
Connections are to be made in interior of pole.
Replace pole cap. A wiring diagram is provided on a label inside luminaire for reference.
For units without leads, connections may be made to terminal board inside fixture.
Note that care should be exercised not to pinch leads between door and housing when closing the door.
External Dimming Control (If Applicable):
• Gray Lead = 0VDC (-) • Violet Lead = Up To 10VDC (+)
Dimming Input/Output
Control Voltage1
Low (0-1.25V) High(7.5-10V)
Nominal Input Wattage2
10% of Max
100%
Nominal Lumen Output2
• 1 Linear Transition between Low and High
• 2 Component and system tolerance may affect the end point levels and linearity of transition
PE Dimming Control (If Applicable):
• No external connections for Dimming are required when the GE Dimming PE Control and GE Dimming PE ­
Receptacle is used.
• All dimming control connections will be made ­
between the Dimming PE and Luminaire through the included PE Receptacle.
• Refer to instructions included with GE Dimming PE Control regarding appropriate settings for dimming control.
Occupancy Sensor (optional):
•
•
The programmable occupancy sensor is shipped with
a default program which may be modified using the
button on the sensor.
The sensor has a separate set of instructions on
programming which is included.
5
MAINTENANCE / CLEANING
WARNING
Risk of electric shock. Make certain power is off before
­attempting any maintenance.
• To maintain high efficiency of the lens, occasional cleaning of the outer lens surface may be needed, with frequency dependent on local conditions.
• Use a mild soap or d
­ etergent, which is essentially neutral pH (pH ­approximately 6 to 8), ­nonabrasive, and which c­ ontains no chlorinated or aromatic
hydrocarbons.
• Wash ­thoroughly, using a soft cloth.
• Rinse with clean, cold water and wipe dry.
6
STORAGE
• Prior to installation, units should NOT be stored ­
outside in c­ orrugated boxes (cardboard b
­ oxes) alone.
• Until installation, all units should be placed in a covered dry storage area. The storage area should not exceed -40°C (-40°F) to 50°C (122°F).
- This can be preferably in a roofed area or with a tarp that is secured in such a way to keep water off of the corrugated boxes (cardboard boxes).
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in
connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not
covered sufficiently for the purchaser’s purposes, the matter should be referred to GE Lighting.
GE Lighting • 1-888-MY-GE-LED (1 - 888 - 69 - 43 - 533) • www.gelighting.com
GE Lighting is a subsidiary of the General Electric Company. Evolve and the GE brand and logo are trademarks of the General Electric Company.
© 2014 GE Lighting. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
35-201578-208 (Rev 09/09/14)
English
GE
Guide d’installation
GEH-6016B
Lighting
Luminaire de zone à DEL Evolve
™
Appareil d’éclairage évolutif (EAS)
ARRÊT
AVANT DE COMMENCER
Lisez attentivement toutes ces instructions.
Conservez ces instructions pour référence future.
AVERTISSEMENT
Risque de choc électrique. Déconnectez l’alimentation
électrique avant d’installer ou réparer ce produit.
AVERTISSEMENT
Danger de blessure et de dommage matériel. L’appareil
tombera au sol s’il est mal installé. Suivez les instructions
d’installation.
ATTENTION
Danger de blessure. Lors de l’installation et de la réparation
de cet appareil, porter des lunettes et des gants de sécurité.
Cet appareil est conforme aux exigences de la partie 15 des règles
de la FCC. Son utilisation est sujette aux conditions suivantes : (1) cet
­appareil ne doit pas causer d’interférences nuisibles; (2) cet appareil
doit accepter toutes les interférences reçues, y compris celles p­ ouvant
causer un fonctionnement i­ndésirable. Ce DEFR de la classe [ A ] est
conforme à la NMB-003 du Canada.
Remarque : Cet appareil a été testé et reconnu conforme aux
limites établies pour les appareils numériques de classe A, selon
la ­partie 15 des règles de la FCC. Ces limites sont conçues pour
­assurer une protection raisonnable contre les interférences nuisibles
dans un environnement commercial. Cet appareil génère, utilise
et émet de l’énergie sous forme de radiofréquences, de sorte que
si son ­installation et son utilisation ne sont pas conformes à la
notice d’utilisation, il peut être la cause de parasites nuisibles aux
­communications radio. L’utilisation de cet équipement dans une zone
résidentielle risque fort de causer des interférences nuisibles, auquel
cas l’utilisateur devra corriger le problème à ses propres frais.
imagination at work
•
Ce luminaire a été conçu pour une utilisation à l’extérieur et ne doit pas être employé sur un site mal ventilé ni dans un endroit clos dont la température ambiante peut être élevée.
• Pour obtenir des performances optimales, il doit
être installé et entretenu conformément aux
recommandations suivantes.
•
Ce luminaire a été conçu pour fonctionner à des
températures ambiantes allant de -40°C à 50°C (-40°C
à 35°C pour >400W) et doit être installé horizontalement
à un poteau vertical de manière à ce que les diodes
soient orientées vers le bas, ou incliné vers le haut à
45° avec un adaptateur d’emboîtement.
SPÉCIFICATIONS
• Poids : Poids maximum < 50 lb (22,68 kg)
• EPA : Montage horizontal : 0,97 pi² max (0,09 m²)
Montage à 45° : 1,97 pi² max (0,18 m²)
• Classification IP : Module optique 65, boîtier électrique standard : Homologation UL 1598 pour
environnement mouillé
1
DÉBALLAGE
3b Montage avec bras architectural sur poteau rond
• Ce luminaire a été soigneusement emballé pour qu’aucune pièce ne subisse de dommages durant
le transport.
• Procédez à une inspection pour vous en assurer.
2
MANUTENTION
• Si le luminaire est incorrectement manipulé hors de
son emballage, il risque d’être endommagé.
• Lorsque le luminaire est sorti de son emballage, il ne
doit pas recevoir le moindre coup ni être empilé.
3
ASSEMBLAGE
Ce luminaire a été spécialement configuré pour être monté sur
un poteau ayant un diamètre de 3,5 po à 4,5 po (89-114 mm). La
configuration des trous sur le poteau rond doit être conforme à la
Figure 2.
• Placez le luminaire contre le poteau.
• Installez le boulon de 3/8 po, la rondelle de frein et la
rondelle plate dans le haut (conformément à l’illustration) et serrez dans la plaque d’écrou.
• Ouvrez le volet du bras et installez le boulon de 3/8 po, la rondelle de frein et la rondelle plate dans le bras
(conformément à l’illustration) et serrez dans la plaque d’écrou (voir les figures 3 et 4).
• Serrez les boulons du haut et du bas au couple de
25-32 lb-pi (34-43 Nm).
• Vérifiez la solidité de l’installation.
AVERTISSEMENT
Danger de blessure et de dommage matériel. L’appareil
tombera au sol s’il est mal installé. Suivez les instructions
d’installation.
Sélectionnez les instructions d’installation correspondant à
la méthode de montage applicable :
a. Montage sur joint coulissant
b. Montage avec bras architectural sur poteau rond
c. Montage avec bras architectural sur poteau carré
d. Adaptateur d’emboîtement pour tenon OD 2-3/8 po.
(60 mm) (angle d’inclinaison verticale de 0 à 45°)
3a Montage sur joint coulissant
Ce luminaire a été spécialement configuré pour être monté
sur des supports de tuyaux de 2 pouces (D. E. 2 3/8 po).
• Tenez le luminaire approximativement au niveau par rapport au tuyau. Faites passer les fils dans le bras et placez le joint coulissant sur le tuyau de 2 pouces (51 mm) (D. E. 2 3/8 po / 60 mm).
• Serrez les quatre boulons de 3/8 po sur le joint
coulissant au couple de 10-14 lb-pi (14-19 Nm). Après le serrage des boulons, serrez les contre-écrous (voir la figure 1).
• Vérifiez la solidité de l’installation.
AVERTISSEMENT
Les boulons du joint coulissant ne doivent jamais être serrés
avec un couple dépassant 14 lb pi (19 Nm).
AVERTISSEMENT
Les boulons de montage du bras architectural ne doivent
jamais être serrés avec un couple dépassant 32 lb pi (43 Nm).
GABARIT DE PERFORATION
MONTAGE SUR POTEAU ROND
Bras de montage sur poteau rond avec
D.E. de 3,5 à 4,5 po (89 à 114 mm)
.312 po DIA.
(8 mm DIA.)
5.2500 po
(133 mm)
(MIN.)
.438 po DIA.
(11 mm DIA.)
(2 ENDROITS)
1.8120 po
(46 mm)
2.7190 po
(69 mm)
.750 po DIA.
(19 mm DIA.)
(TROU)
5.4380 po
(138 mm)
FIGURE 2
Serrer le boulon
supérieur au couple
de 25-32 lb-pi
(34-43N-m)
Volet
Serrer le boulon
supérieur au couple
de 25-32 lb-pi
(34-43N-m)
Vis de volet de bras
FIGURE 3
Vue en coupe : Montage sur poteau rond
Bras architectural avec volet
Boulons 3/8 de joint coulissant avec
contre-écrous
Poteau
Plaque d’écrou
FIGURE 1
Boulon, rondelle de
frein, rondelle plate
Vis de volet de bras
FIGURE 4
3c Montage avec bras architectural sur
poteau carré
Ce luminaire a été configuré comme celui du paragraphe 3b
et une plaque adaptatrice a été ajoutée pour permettre une
installation sur un poteau carré. La configuration des trous sur
le poteau carré doit être conforme à la Figure 5.
• Orientez la plaque adaptatrice afin que le trou ovale soit plus près du haut que du bas de la plaque.
• Après avoir vérifié l’orientation de l’extrémité de la plaque
adaptatrice, installez la plaque sur le poteau avec l’aide de la plaque d’écrou, des boulons 3/8-16 et des rondelles
incluses, conformément à l’illustration. Serrez les boulons
3/8-16 au couple de 25-32 lb-pi (34-43 Nm)
(voir la figure 6).
• Placez le luminaire contre la plaque adaptatrice.
• Installez le boulon de 3/8 po, la rondelle de frein et la
rondelle plate dans le haut (conformément à la figure 7) et serrez dans la plaque d’écrou.
• Ouvrez le volet du bras et installez un boulon de 3/8 po
dans le trou fileté du bloc adaptateur (voir la figure 7).
• Serrez les boulons du haut et du bas au couple de
25-32 lb-pi (34-43 Nm).
• Vérifiez la solidité de l’installation.
GABARIT DE PERFORATION
MONTAGE SUR POTEAU CARRÉ
.312 po DIA.
(8 mm DIA.)
5.2500 po
(133 mm)
(MIN.)
.438 po DIA.
(11 mm DIA.)
(2 ENDROITS)
2.1960 po
(56 mm)
1.8120 po
(46 mm)
4.3920 po
(112 mm)
1.250 po DIA.
(32 mm DIA.)
(TROU)
BRAS DU LUMINAIRE SUR ADAPTATEUR
Serrer le boulon
supérieur au couple de
25-32 lb-pi (34-43 Nm)
Serrer le boulon
inférieur au couple de
25-32 lb-pi (34-43 Nm)
FIGURE 7
3d Adaptateur d’emboîtement pour OD tenon de
2-3/8 po. (60 mm) à 3 po. (76 mm)
Ce luminaire a été spécifiquement configuré pour fournir une
inclinaison verticale de 0 à 45° par incréments de 5° et se monter
sur un tuyau OD de 2-3/8-po. (73 mm) à 3 po. (76 mm).
•
•
•
•
Placez l’adaptateur d’emboîtement sur le tenon.
On utilise trois vis de fixation pour solidement fixer le projecteur
au tuyau. Serrez les vis de fixation jusqu’à 18-22 pied-livre
(24-30 N-m).
Pour orienter le luminaire, desserrez l’écrou articulé, ajustez
l’orientation entre 0 et 45° et vissez jusqu’à 45-50 pied-livre
(61-68 N-m).
Vérifiez la solidité de l’installation.
26.776
in.
26.776 in.
[680 mm)
mm]
(680
2.3
in.
2.3 in.
(57
[57 mm)
mm]
45° max upward
aim
Orientation
vers
le haut 45° max.
5.0
5.0 in.
in.
[127 mm)
mm]
(127
.656 po (17 mm)
1.312 po (33 mm)
FIGURE 5
7.3
7.3 in.
in.
(186
[186 mm)
mm]
R26.9 in.
R26.9
in.
[R683 mm]
(R683
mm)
Serrez
écrou articulé
Tighten Knuckle
Bolt
to 45-50 Foot
Pounds
jusqu’à
45-50
pied-livre
3.805 in.
3.805
in.
[97 mm)
mm]
(97
PLAQUE ADAPTATRICE POUR
POTEAU CARRÉ
2-3/8de
in.2-3/8
(60mm)(60
to 3.0
in. (76mm)
OD
mm)
à 3 po.OD
(76only
mm) uniquement
Tighten 33Set
to 18-22
Serrez
visScrews
de fixation
jusqu’à 18-22 pied-livre
Foot Pounds
Plaque d’écrou
Plaque adaptatrice
4
CÂBLAGE
ATTENTION
Danger de blessure et de dommage matériel. Le volet
doit être fermé avec sa vis jusqu’à ce que le luminaire soit
à son emplacement final.
Boulons 3/8-16 et rondelles
Serrer les boulons au couple
de 25-32 lb-pi (34-43 Nm)
FIGURE 6
• REMARQUE: Toutes les connexions doivent être
conformes aux normes électriques nationales et à la réglementation locale en vigueur (code électrique du Canada et réglementation locale applicable).
• Un dispositif anti-tension doit être installé par le client sur le câble d’alimentation en haut du poteau.
• Type et taille du câble d’alimentation (pour
connexion par le client sur plaque de connexions) :
16 AWG (1,5mm2) à 6 AWG (10mm2) plein ou tressé.
Connexions de la plaque de connexions :
Position sur la plaque de connexions
Type d’alimentation
L1
Ligne de phase
G
Terre
N/L2
Ligne basse/neutre
• REMARQUE: Assurez vous que la tension électrique est adéquate en vérifiant la plaque signalétique à l’intérieur du volet ou sur la boîte.
Commande photoélectrique :
• (Si l’option est choisie) Le réceptacle de la commande peut être orienté avant d’installer la commande.
• Desserrez les deux vis de retenue et faites tourner le réceptacle jusqu’à ce que l’inscription « North » soit orientée le plus près possible du nord véritable.
• Assurez-vous que la douille sous le réceptacle de commande photoélectrique est bien appuyée et qu’il n’existe aucun espace d’infiltration d’eau sous le réceptacle.
• Serrez les vis de retenue et installez la commande.
Branchements électriques :
• Connectez les fils conducteurs du luminaire au câble
d’alimentation.
• Les connexions doivent être faites à l’intérieur du poteau.
• Réinstallez le capuchon du poteau. Un schéma de câblage figure sur une étiquette à l’intérieur du
luminaire pour référence.
• Si vous utilisez un joint sans fils conducteurs, les
connexions peuvent être faites sur la plaque de
connexions à l’intérieur du luminaire.
• Faites attention de ne pas pincer les fils entre le volet et le boîtier lorsque vous fermez le volet.
Gradateur externe (si applicable) :
• Fil gris = 0 V c.c. (-)
• Fil violet = Jusqu’à 10 V c.c. (+)
Gradation, entrée/sortie
Tension de commande1
Basse (0-1.25V) Élevée (7.5-10V)
Puissance nominale d’entrée2
10% du Maxi
100%
Sortie nominale en lumens2
•
•
1
Transition linéaire entre basse et élevée
Les tolérances des composants et du système peuvent affecter les niveaux de point final et la linéarité de la transition
Gradateur photoélectrique (si applicable) • Aucune connexion externe de gradation n’est
nécessaire lorsque la commande de gradateur PE et
le réceptacle de gradateur PE de GE sont utilisés.
• Toutes les connexions de commande de gradation seront réalisées entre le gradateur PE et le luminaire via le réceptacle PE inclus.
• Lire les instructions incluses avec la commande de gradateur PE de GE concernant les réglages
appropriés de la commande de gradateur.
Détecteur de présence (en option) :
• Le détecteur de présence programmable est expédié
avec une programmation par défaut que l’on peut
modifier à l’aide du bouton situé sur le détecteur.
• Le détecteur est fourni avec des instructions de
programmation séparées.
5
ENTRETIEN ET NETTOYAGE
AVERTISSEMENT
Risque de choc électrique. Avant de commencer toute
opération d’entretien, assurez-vous que l’alimentation
électrique est coupée.
• Pour conserver l’efficacité de la lentille, nettoyez périodiquement la surface extérieure de la lentille (la
fréquence des nettoyages dépendra des conditions locales).
• Utilisez un savon doux ou un détergent essentiellement
neutre (ayant un pH d’environ 6 à 8), sans abrasif et sans
hydrocarbure chloré ou aromatique.
• Lavez à fond avec la solution de nettoyage en
utilisant un chiffon doux.
• Rincez avec de l’eau froide et propre, puis essuyez.
6
ENTREPOSAGE
• Avant leur installation, les luminaires ne doivent PAS être
entreposés à l’extérieur dans de simples boîtes en carton.
• Jusqu’à leur installation, tous les luminaires doivent être conservés dans un lieu de stockage couvert et sec. La température du site de stockage doit se situer entre -40 ºC et 50 ºC (-40 ºF et 122 ºF).
- Conservez-les préférablement sous un toit ou sous une bâche installée solidement de façon à ce que l’eau ne puisse atteindre les boîtes en carton.
2
Ces instructions n’ont pas pour but de couvrir tous les détails et toutes les variantes de l’équipement, ni de répondre à tous les impondérables
­possibles en relation avec l’installation, le fonctionnement et l’entretien. Si vous désirez plus d’informations ou si des problèmes particuliers
­surviennent qui ne sont pas couverts suffisamment pour les besoins de l’acheteur, le sujet doit être soumis à GE Lighting.
GE Lighting • 1-888-MY-GE-LED (1 - 888 - 69 - 43 - 533) • www.gelighting.com
GE Lighting est une filiale de la General Electric Company. Evolve ainsi que la marque et le logo GE sont des marques commerciales déposées de la General Electric Company.
© 2014 GE Lighting. Les informations fournies ici sont susceptibles de changer sans préavis. Toutes les données sont des valeurs de conception ou caractéristiques lors de leur
mesure en conditions de laboratoire.
35-201578-208 (Rev 09/09/14)
French
GE
Guía de Instalación
GEH-6016B
Lighting
Lámpara de Área Evolve LED
™
Lámpara Escalable (EAS, por sus siglas en inglés)
ANTES DE EMPEZAR
Lea estas instrucciones por completo y
detenidamente. Guarde estas instrucciones para
uso futuro.
ADVERTENCIA
Riesgo de descarga eléctrica. Desconecte la fuente
de energía antes de dar mantenimiento o al instalar el
producto.
ADVERTENCIA
Riesgo de lesiones o daño. La unidad caerá si no es instalada
apropiadamente. Siga las instrucciones de instalación.
ADVERTENCIA
Riesgo de lesiones. Use gafas de protección y guantes
durante instalación y servicio.
Este aparato cumple con Parte 15 de las Reglas FCC. Su operación
está sujeta a las siguientes dos condiciones: (1) Este aparato no puede
causar interferencia perjudicial, y (2) este aparato debe aceptar
cualquier interferencia recibida, incluyendo interferencia que pueda
causar una operación no deseada. Esta Clase [A] RFLD cumple con
el estándar Canadiense ICES-003. Ce DEFR de la classe [ A ] est
conforme à la NMB-003 du Canada.
Nota: Este equipo ha sido probado y cumple con los límites para la
Clase A de aparatos digitales, conforme a la parte 15 de las Reglas
FCC. Estos límites están diseñados para proveer protección necesaria
para contrarrestar interferencia perjudicial cuando el equipo está en
operación en un ambiente comercial. Este equipo genera, usa y puede
irradiar energía de radio frecuencia y, si no es instalado y usado
conforme a las instrucciones del manual, puede causar interferencia
perjudicial a radiocomunicaciones. La operación de este equipo en
una zona residencial probablemente causará interferencia perjudicial,
en cual caso el usuario deberá corregir por su propia cuenta.
imagination at work
• La luminaria está diseñada para iluminación exterior,
y no deberá ser usada en áreas con ventilación
limitada, o a altas temperaturas ambientales.
• P
ara mejores resultados instale y mantenga de
acuerdo con las siguientes recomendaciones. ­
• Las luminarias están diseñadas para operar en tem-
peraturas ambiente de -40°C a 50°C (-40°C a 35°C para
>400W) y para ser montada en posición horizontal a
un poste vertical con los LEDs apuntando hacia abajo,
o inclinados al alza hasta a 45° con la ayuda de un
vástago desmontable articulado.
ESPECIFICACIONES
• Peso: Peso máximo <50 libras (22.68 kg)
• Área Proyectada Efectiva (EPA, por sus siglas en inglés):
Montaje horizontal: 0.97 pies2 max (0.09 m2)
Montaje a 45°: 1.97 pies2 max (0.18 m2)
• Grado IP: IP65 óptico, caja de protección eléctrica
estándar:
UL 1598 Especificado para entorno húmedo
1
3b Montaje con Brazo para Poste Redondo
DESEMPAQUE
•
Esta luminaria ha sido empacada adecuadamente
para que ninguna parte se dañe durante su envío.
• Inspeccione para confirmar su estado.
2
MANEJO
•Daños pueden ocurrir si la luminaria se maneja
inadecuadamente fuera de su empaque.
•No golpee o almacene la luminaria después de haberla
removido de su empaque.
3
MONTAJE
Esta luminaria ha sido configurada específicamente para ser
montada a un poste redondo de 3.5 a 4.5 pulgadas (89-114
mm) de diámetro. La plantilla de perforación deberá ser igual
a la Figura 2.
• Coloque la luminaria contra el poste.
•Instale las tuercas de 3/8, la arandela de seguridad
y arandela en la parte superior como se muestra y
apriete a la placa para tuerca.
•Abra la puerta del brazo e instale el tornillo de 3/8, la
arandela de seguridad y arandela dentro del brazo
como se muestra y apriete a la placa para tuerca.
(Figura 3 y 4).
•Aplique torque de 25 a 32 libras por pie (42-43 N-m) a
los tornillos superiores e inferiores.
•Inspeccione la instalación para asegurarse que el
equipo esté firmemente sujeto.
ADVERTENCIA
Riesgo de lesión o daño. La unidad caerá si no es instalada
apropiadamente. Siga las instrucciones de instalación.
Siga las instrucciones de instalación apropiadas de acuerdo
al método de montaje elegido:
a. Montaje de Vástago Desmontable
b. Montaje con Brazo Arquitectónico para Poste Redondo
c. Montaje con Brazo Arquitectónico para Poste Cuadrado
d. Vástago desmontable articulado para acoplamiento
de 2- 3/8 pulg. (60mm) de diámetro exterior (0 a 45°
inclinación vertical)
3a Montaje de Vástago Desmontable
Esta luminaria ha sido configurada específicamente para
ser montada a un tubo de soporte de 2 pulgadas (2-3/8
pulgadas de diámetro total).
•Mantenga la luminaria aproximadamente a nivel del
tubo de soporte. Jale los cables a través del brazo y
coloque el vástago desmontable sobre el tubo (2-3/8
pulgadas 60 mm de diámetro total) de 2 pulgadas (51mm)
•
Apriete los (4) tornillos 3/8 del vástago desmontable a
10-14 libras por pie (14-19 N-m). Apriete las tuercas después
que los tornillos hayan sido apretados. (Vea Figura 1).
•Inspeccione la instalación para asegurarse que el
equipo esté firmemente sujeto.
ADVERTENCIA
Bajo ninguna circunstancia se deberá apretar los tornillos
con un nivel de torque mayor a 14 libras por pie (19 N-m).
ADVERTENCIA
Bajo ninguna circunstancia se deberá apretar los tornillos del
brazo con un torque mayor a 32 libras por pie (43 N-m).
PLANTILLA DE PERFORACIÓN
MONTAJE EN POSTE REDONDO
Brazo de montaje para poste redondo de diámetro
exterior de 3.5 a 4.5 pulgadas (89 a 114mm)
.312 pulg. DIA.
(8 mm DIA.)
5.2500 pulg.
(133 mm)
(MIN.)
.438 pulg. DIA.
(11 mm DIA.)
(2 LUGARES)
1.8120 pulg.
(46 mm)
2.7190 pulg.
(69 mm)
.750 in. DIA.
(19 mm DIA.)
(ORIFICIO)
5.4380 pulg.
(138 mm)
FIGURA 2
Aplique 25-32 libras por
pie de torque a tornillo
superior
(34-43N-m)
Puerta
Aplique 25-32 libras por
pie de torque a tornillo
inferior
(34-43N-m)
Tornillo para Puerta del Brazo
FIGURE
A3
Vista Seccional: Brazo para Montaje en Poste Redondo
Brazo Arquitectónico con Puerta
Tornillos 3/8 y Tuercas del Vástago Desmontable
Poste
Placa para Tuerca
Tuerca de Poste, Arandela
de Seguridad, Arandela
Tornillo para Puerta del Brazo
FIGURA 1
FIGURA 4
3c Montaje con Brazo para Poste Cuadrado
Esta luminaria está configurada igual que 3b y una
placa adaptadora ha sido incluida para ser montada a
un poste cuadrado. La plantilla de perforación deberá
ser igual a la Figura 5.
•Oriente el bloque adaptador de manera que el hoyo
ovalado esté más cercano a la parte superior que la
inferior del adaptador.
•Con el borde del bloque adaptador correctamente
orientado, monte el bloque adaptador al poste con
la placa para tuerca y los tornillos de 3/8-16 y la
arandela incluidos como se muestra. Aplique 25-32
libras por pie (34-43 N-m) de torque a los tornillos de
3/8-16. (Vea Figura 6)
• Coloque la lámpara contra el bloque adaptador
•Instale el tornillo de 3/8, la arandela de seguridad, y
la arandela en la parte superior como se muestra y
ajuste al bloque adaptador. (Vea Figura 7)
•Abra la puerta del brazo e instale el tornillo de 3/8 al
orificio roscado del bloque adaptador. (Vea Figura 7)
•Aplique 25-32 libras por pie (34-43 N-m) de torque a
los tornillos superiores e inferiores
•Inspeccione la instalación para asegurarse que el
equipo este firmemente sujeto.
PLANTILLA DE PERFORACIÓN
MONTAJE EN POSTE CUADRADO
.312 pulg. DIA.
(8 mm DIA.)
.438 pulg. DIA.
(11 mm DIA.)
(2 LUGARES)
5.2500 pulg.
(133 mm)
(MIN.)
1.8120 pulg.
(46 mm)
2.1960 pulg.
(56 mm)
4.3920 pulg.
(112 mm)
1.250 pulg. DIA.
(32 mm DIA.)
(HOLE)
Aplique 25-32 libras por pie
de torque a tornillo superior
(34-43N-m)
BRAZO DE LÁMPARA PARA
ADAPTADOR DE BRAZO
Aplique 25-32 libras por pie
de torque a tornillo inferior
(34-43N-m)
FIGURA 7
3d Vástago Desmontable Articulado para un
acoplamiento de diámetro exterior de 2-3/8
pulg. (60mm) a 3.0 pulg. (76mm).
Esta luminaria ha sido configurada específicamente para
ser posicionada de una manera vertical de 0° a 45° en
incrementos de 5° y montada en un tubo de 2-3/8-pulg. de
diámetro exterior. (73mm) a 3-pulg. de diámetro exterior. (76mm).
•Coloque el vástago desmontable en el acoplamiento.
•Los tres tornillos se usan para ajustar la lámpara
seguramente al tubo. Apriete los tornillos con un
torque de 18-22 libras pies (24-30 N-m).
• Para inclinar la luminaria, desatornille el perno de la
articulación, ajuste la inclinación de 0 a 45° , y apriete
a 45-50 libras pie (61-68 N-m).
• Inspeccione la instalación para corroborar que la
instalación es segura.
26.776
26.776 pulg.
in.
[680
(680mm]
mm)
2.3
2.3pulg.
in.
(57
[57 mm)
mm]
45°de
max
upward aimal alza máxima
45°
inclinación
5.05.0pulg.
in.
[127 mm)
mm]
(127
.656 pulg. (17 mm)
1.312 pulg. (33 mm)
FIGURA 5
7.37.3pulg.
in.
(186
[186 mm)
mm]
R26.9pulg.
in.
R26.9
[R683 mm)
mm]
(R683
Apriete
el tornillo
Tighten Knuckle
Bolt a
to 45-50libras
Foot Pounds
45-50
pie
PLACA ADAPTADORA PARA
POSTE CUADRADO
3.805pulg.
in.
3.805
[97 mm)
mm]
(97
Placa de Tuerca
2-3/8 in.pulg.
(60mm)
to 3.0 in.
OD (76mm)
only
2-3/8
(60mm)
a (76mm)
3.0 pulg.
Diámetro Exterior
Tighten 3 Set Screws
to 18-22
solamente.
Apriete
los 3 tornillos a 18-22 libras pie.
Foot Pounds
Bloque Adaptador
4
CABLEADO
PRECAUCIÓN
Riesgo de lesiones o daño: Puerta debe de estar cerrada
con tornillo hasta que el aparato esté en su posición final.
3/8-16 Arandela y Tornillo
Aplique 25-32 libras por pie
(34-43 N-m) de torque a
tornillos
FIGURE 6
• N
OTA: Todas las conexiones eléctricas deberán
realizarse de acuerdo con el Código Eléctrico Nacional y
conforme a códigos locales correspondientes.
•Liberación de tensión debe de ser proporcionado por el
usuario para la fuente de poder en el poste.
•Proporcione el tipo y tamaño de cable para la conexión
del usuario a la placa terminal: 16 AWG (1.5mm2) a 6
AWG (10mm2) Sólido o Trenzado.
Conexiones de Placa Terminal:
Posición de Placa Terminal Tipo de Suministro
L1
Línea Alta
G
Puesta a Tierra
N/L2
Línea Baja/Neutro
• N
OTA: Verifique que el voltaje de alimentación sea
correcto comparándolo con la placa del fabricante
localizada dentro de la puerta o en la caja.
Control Fotoeléctrico:
•(Si la opción está presente)—Receptáculo de control
fotoeléctrico debe de ser orientado antes de instalar el
control.
•Afloje los dos tornillos sujetadores y gire el receptáculo
hasta que el “norte” se dirija lo más posible al norte real.
•Verifique que el anillo debajo del receptáculo PE esté
fijo y que no hay ningún espacio que deje entrar agua
al aparato por debajo del receptáculo PE.
• Apriete los tornillos sujetadores e instale el control.
Conexión Eléctrica:
•Conecte los conectores de cable de la luminaria al
cable de suministro.
•
Conexiones deberán de ser hechas en el interior del poste.
•
Reemplace la tapa del poste. Diagrama de cableado está
como referencia en la etiqueta dentro de la luminaria
•
Para las unidades sin conectores, las conexiones puedes
ser hechas en la placa terminal dentro del aparato.
•Tenga cuidado de no pellizcar los conectores de cable
entre la puerta y la caja al cerrar la puerta.
Control Regulador de Intensidad Externo (Si aplica):
• Conector Gris = OVDC (-)
• Conector Violeta = Hasta 10VDC (+)
Entrada/Salida de Regulador de Intensidad
Control de Voltaje1
Entrada Nominal de Potencia2
Salida Nominal de Lumen2
Bajo (0-1.25V) Alto (7.5-10V)
10% de Máximo100%
• 1 Transición linear entre alto y bajo
2
•
Tolerancia de componente y sistema puede afectar
los niveles finales y la linealidad de transición
Control Regulador de Intensidad PE (Si aplica):
•
Ninguna conexión externa para regular la intensidad
son requeridas cuando el Control Regulador de
Intensidad PE de GE y el Receptáculo del Regulador
de Intensidad PE de GE son usados.
•Todas las conexiones de regulación de intensidad
serán hechas entre el regulador de intensidad PE y la
luminaria a través del receptáculo PE incluido.
•Consulte las instrucciones incluidas en el Control
Regulador de Intensidad PE de GE en cuanto a la
configuración adecuada para el control regulador de
intensidad.
Sensor de Presencia (opcional):
•
El sensor de presencia programable se envía con un
programa estándar el cual puede ser modificado usando el botón en el sensor.
•El sensor tiene incluido un set de instrucciones de
programación por separado.
5
MANTENIMIENTO/LIMPIEZA
ADVERTENCIA
Riesgo de descarga eléctrica: Desconecte la fuente de
energía antes de dar mantenimiento.
•Para mantener la alta eficiencia del lente, limpieza
ocasional de la superficie exterior del lente puede
ser necesaria y su frecuencia dependerá de las
condiciones locales.
•Use un detergente o jabón suave, con un pH neutro,
no abrasivo y que no contenga hidrocarbonos
aromatizantes o con cloro.
• Lave a fondo, usando un paño suave.
• Enjuague con agua fría y limpia y seque.
6
ALMACENAMIENTO
• Antes de su instalación, las unidades no deben de
•
ser almacenadas a la intemperie solo en cajas (cajas
de cartón) corrugadas.
Todas las unidades deben de ser almacenadas en
un área seca y cubierta hasta que sean instaladas.
El área de almacenamiento no deberá de exceder
-40°C (-40°F) a 50°C (122°F).
-- Éste puede ser preferiblemente en un área
techada o con una lona que proteja a las cajas
corrugadas (cajas de cartón) contra el agua.
Estas instrucciones no pretenden cubrir todos los detalles o variaciones de equipo, ni cada posible contingencia encontrada en conexión a la
instalación, operación o mantenimiento. Si más información es requerida ó ciertos problemas particulares surgen, los cuales no son abarcados
suficientemente para los requerimientos del comprador, el asunto debe de ser referido a GE Iluminación.
GE Lighting • 1-888-MY-GE-LED (1 - 888 - 69 - 43 - 533) • www.gelighting.com
GE Lighting es una subsidiaria de la Compañía General Electric. Evolve y la marca y logotipo de GE son marcas registradas de la Compañía General Electric.
©2014 GE Lighting. La información se encuentra sujeta a cambio sin previo aviso. Todos los valores son de diseño, o valores típicos al momento de ser medidos
bajo condiciones de laboratorio.
35-201578-208 (Rev 09/09/14)
Spanish