Manu-Cop.vp:CorelVentura 7.0
Transcription
Manu-Cop.vp:CorelVentura 7.0
Document: M-181.1-LCD6000-ENG Issue: 06/1999 Rev. : B.1 LCD-6000 Installation manual NOTIFIER ITALIA a Pittway Company INDEX FRONT PANEL 1 LEDs 1 KEYPAD 2 CABINET DIMENSIONS 4 BOARD LAYOUT 5 LCD-6000 PROGRAMMING 6 SW1 DIP SWITCH 6 SW2 DIP SWITCH 6 "CN0" CONNECTOR ON LCD-6000 7 POWER SUPPLY SPECIFICATIONS 8 » NOTE: this LCD-6000 is enabled to operate on AM-6000 control panels with EPROM version dated 20/05/97 or next. Eng-ndx.VP Doc. M-181.1-LCD6000-ENG Installation manual Rev. B.1 NOTIFIER ITALIA FRONT PANEL GENERAL ALARM LED LIST ACKNOWLEDGE SIGNAL SILENCE GENERAL SIGNAL SILENCE TROUBLE LED RESET LAMP TEST LED LEDs The general alarm led (Red) is: • • • BLINKING when the control panel detects one or more alarms STEADY ON when the alarm condition has been acknowledged by pressing the ACK key TURNED OFF when no alarm events exist The general trouble led is: • • • BLINKING when on the control panel the following failures are detected: OFF LINE (LCD6000 OFF line). This message appears on the display. ZONE TROUBLES SYSTEM TROUBLES STEADY ON when the trouble condition has been acknowledged by pressing the ACK key TURNED OFF when no trouble events exist The signal silence led turns on if in alarm condition the signal silence key is pressed. LCD6000-MANU-ist.VP Doc. M-181.1-LCD6000-ENG Installation manual Rev. B.1 Page 1 NOTIFIER ITALIA KEYPAD The RESET key allows to clear the alarm events if previously they have been acknowledged by pressing the ACK key. Note 1 * The ACK key allows to perform the Trouble and Alarm acknowledge and the buzzer silence. Note 1 * The SIGNAL SILENCE key allows to deactivate the controls activated after an alarm event. » NOTE. : The controls must be programmed as silenceable. Note 1*: No password is required to perform this function. The LAMP TEST key allows to perform a test of LEDs. The test will illuminate the LCD-6000 LEDs for a timed period and the display backlite. The LIST key, in case of alarm or trouble events, allows to display the list of the single points in alarm or trouble condition. Procedure to display the Event list during a SYTSTEM TROUBLE condition only SYSTEM TROUBLE NOTE: you can leave this menu only for time out, after 60 seconds. Press once the LIST key Select an event list: TO SELECT 1 = ZONE ALARMS 2 = ZONE TROUBLES > 3 = SYSTEM TROUBLES TO CONFIRM 4 = ZONES EXCLUDED 5 = POINTS EXCLUDED 3= SYSTEM TROUBLES The 1 st and the last trouble are displayed Page 2 NOTIFIER ITALIA Press the down cursor key to Press scroll the trouble list the LIST key Installation manual Rev. B.1 LCD6000-MANU-ist.VP Doc. M-181.1-LCD6000-ENG Procedure to display the Event list during an ALARM/TROUBLE condition ZONE 1 ALARM ZONE 20 ALARM Press once the LIST key Display the ZONE 1 points NOTE: you can leave this menu only Press the down cursor key to scroll the list of Press the the points in alarm condition. for time out, after 60 seconds. LIST key Select an event list: > TO SELECT 1 = ZONE ALARMS 2 = ZONE TROUBLES TO CONFIRM 3 = SYSTEM TROUBLES 4 = ZONES EXCLUDED 5 = POINTS EXCLUDED 1 = ZONE ALARMS st 1 ZONE ALARM LAST ZONE ALARM Use the cursor key to select the zone Press the LIST key to display the points in alarm condition of the zone selected. Press the down cursor key Press the LIST key to scroll the list of the points to escape in alarm condition. LCD6000-MANU-ist.VP Doc. M-181.1-LCD6000-ENG Installation manual Rev. B.1 Page 3 NOTIFIER ITALIA CABINET DIMENSIONS Page 4 NOTIFIER ITALIA Installation manual Rev. B.1 LCD6000-MANU-ist.VP Doc. M-181.1-LCD6000-ENG BOARD LAYOUT LCD6000-MANU-ist.VP Doc. M-181.1-LCD6000-ENG Installation manual Rev. B.1 Page 5 NOTIFIER ITALIA LCD-6000 PROGRAMMING “SW1” DIP SWITCH TERMINAL Nr. DENOMINATION USE 1 NOT USED 2 NOT USED 3 NOT USED 4 NOT USED 5 NOT USED 6 IT MUST BE in ON position on the last LCD-6000* 7 IT MUST BE in OFF position 8 NOT USED » NOTE: * ON= last device / OFF= intermediate device. The “LAST DEVICE” is the one connected on the return lines towards the control panel, this means, those lines directly wired to the terminals 11 and 12 of control panel CN0 connector. “SW2” DIP SWITCH TERMINAL Nr. DENOMINATION USE 1 NOT USED 2 In ON position, the buzzer activate each time an event occurs 3 In ON position it enables the RESET key 4 In ON position it enables the ACKNOWLEDGE key 5 In ON position it enables the SIGNAL SILENCE key 6 OFF= AM6000 serial protocol 7 NOT USED 8 NOT USED Page 6 NOTIFIER ITALIA Installation manual Rev. B.1 LCD6000-MANU-ist-1.VP Doc. M-181.1-LCD6000-ENG CN0 CONNECTOR on LCD-6000 TERMINAL DENOMINATION NOTE USE CABLE COLOUR/NR. Nr. 1 GROUND 2 NOT USED 3 NOT USED 4 NOT USED 5 NOT USED 6 NOT USED 7 GND 8 LIN + A (OUT) RS 422 towards the control panel or the next terminal 9 LIN - A (OUT) RS 422 towards the control panel or the next terminal 10 GND 11 LIN + R (IN) RS 422 from the control panel or the previous terminal 12 LIN - R (IN) RS 422 from the control panel or the previous terminal 13 + 24 V Positive Power Supply 14 + 24 V Positive Power Supply 15 GND Negative Power Supply 16 GND Negative Power Supply Example of LCD-6000 panel connected to the AM-6000 control panel SHIELDED CABLE 2 AWG 16 (1,31 mm ) MAX LENGHT 1800 m. NR. OF LCD-6000 CONNECTABLE: 32 MAX CN0 LCD-6000 AM6000 CONTROL PANEL BE600A BOARD NOTE: Setting of LCD-6000 SW 1 - DIP 6 = OFF » NOTE: the power supply wiring is not indicated. If local power supplies are used, the negative line must be common between the control panel and the LCD-6000. LCD6000-MANU-ist-1.VP Doc. M-181.1-LCD6000-ENG Installation manual Rev. B.1 Page 7 NOTIFIER ITALIA Example of LCD-6000 panel connected to the AM-2000 control panel SHIELDED CABLE 2 AWG 16 (1,31 mm ) MAX LENGHT 1800 m. LCD-6000 CN1 AM2000 CONTROL PANEL N.B.: Setting of LCD-6000 SW 1 - DIP 6 = OFF the terminal emulation software must be programmed with communication speed equals » NOTE: to 2400 BAUD Example of LCD-6000 panels connected in series 1 TO THE LCD-6000 st SW1 - DIP 6 = OFF CONTROL PANEL 2 LCD-6000 nd SW1 - DIP 6 = OFF LAST LCD-6000 SW1 - DIP 6 = ON SHIELDED CABLE 2 AWG 16 (1,31 mm ) MAX LENGHT 1800 m POWER SUPPLY SPECIFICATIONS • • • Power Supply: 15 to 30 VDC Max current absorption: 180 mA @ 27,6 V Stand-by current absorption: 80 mA @ 27,6 V Page 8 NOTIFIER ITALIA Installation manual Rev. B.1 LCD6000-MANU-ist-1.VP Doc. M-181.1-LCD6000-ENG Document: M-181.1-LCD6000-ENG Issue: 06/1999 Rev. : B.1 All rights reserved. All specifications are subject to change without notice. Delivery times depend on product availability. NOTIFIER ITALIA S.r.l. Via Grandi, 22 - 20097 San Donato Milanese (MI) Tel. : 02/51897.1 (ISDN) Fax : 02/5189730 http://www.notifier.it