FR - COMPENSATOR KIT code 8101528
Transcription
FR - COMPENSATOR KIT code 8101528
GB - COMPENSATOR KIT code 8101528 FR - COMPENSATOR KIT code 8101528 SUPPLY The kit, designed for “PLANET DEWY 60 BFR” boilers, comprises the following: - 2 brass reducers 1 1/2” x 1” code 6120522 - System supply pipe code 6291967 - Expansion vessel 8 liter code 6245108 - Connection pipe for expansion vessel code 6227680 - System return pipe code 6227424 - Hydraulic compensator code 6216312 - Probe for 2000 litre boiler code 6231331 - Blind cap in brass 1” code 6229502 - 2 reducers 2” NPT code 6104712 - Gaskets. FOURNITURE Le kit destiné à être utilisé dans les chaudières "PLANET DEWY 60 BFR" est fourni équipé de : - N. 2 raccords cuivre 1 1/2" x 1" cod. 6120522 - Tuyau refoulement installation cod. 6291967 - Vase expansion 8 litres cod. 6245108 - Tuyau connexion vase expansion cod. 6227680 - Tuyau retour installation cod. 6227424 - Compensateur hydraulique cod. 6216312 - Sonde bouilleur L. 2000 cod. 6231331 - Bouchon aveugle cuivre 1” cod. 6229502 - N. 2 raccords 2" NPT cod. 6104712 - Garnitures. INSTALLATION OF BOILER The kit can be fitted on accumulation boilers optional series “BT”. The intended boiler pump should be dimensioned in function of the hot water circuit losses (boiler + piping) and the minimum guaranteed capacity (2,200 l/h). Electrically connect the boiler pump (PB) as shown in the wiring diagram applied to the boiler (to access the cable supplied with the kit, move the control panel forward and remove the insulated terminal). Then, connect the boiler probe (SB), supplied with the kit, as shown in the boiler diagram. INSTALLATION BOUILLEUR Le kit est prédisposé pour le placement d'un bouilleur à accumulation série “BT” en option. La pompe bouilleur à utiliser doit être dimensionnée en fonction des pertes du circuit sanitaire (bouilleur + tuyauteries) et du débit minimum devant être garanti (2.200 l/h). Relier électriquement la pompe du bouilleur (PB) comme indiqué dans le schéma électrique apposé sur la chaudière (pour accéder au câble fourni de série, tourner le panneau des commandes vers l'avant et éliminer la borne isolée). La sonde du bouilleur également (SB), fournie dans le kit, doit être reliée comme indiqué dans le schéma de la chaudière. ASSEMBLY MONTAGE 45 265 DIMENSIONS DIMENSIONS R3 7 6 146 1 3 2 500 455 6 4 5 10 11 865 8 3 9 12 M2 M2 265 M R M2 R3 R C.H flow / Refoulement installation C.H. return / Retour installation Tank flow / Refoulement bouilleur Tank return / Retour bouilleur M 330 88 2” NPT 2” NPT G 1” G 1” 582 305 R M KEY/LEGENDE 1 Gasket / Garniture ø 23/33 x 3 (n. 2) 2 Brass reducer / Raccord cuivre 1 1/2” x 1” (n. 2) 3 Gasket / Garniture ø 33,5/45 x 2 (n. 4) 4 System supply pipe / Tuyau refoulement installation 5 System return pipe / Tuyau retour installation 6 Gasket / Garniture ø 17/24 x 2 (n. 2) 7 Expansion vessel pipe / Tuyau vase d'expansion 8 Expansion vessel 8 liter / Vase expansion 8 litres 9 Hydraulic compensator / Compensateur hydraulique 10 Brass blind cap 1” / Bouchon aveugle cuivre 1” 11 Gasket / Garniture ø 22/30 x 2 12 Reducer 2” NPT / Raccord 2” NPT HYDRAULIC DIAGRAM SCHÉMA HYDRAULIQUE 8 7 CURVE LOAD LOSSES/CAPACITY BETWEEN THE ATTACKS R3 and M2 5 COURBE PERTES DE CHARGE/DEBITS ENTRE LES POINTS R3 et M2 Planet Dewy 60-100 BFR LOAD LOSSES (mbar) PERDITE DI CARICO TRA PERTES CHARGE GLI ATTACCHI R3DE e M2 (mbar) (mbar) 800 6 700 600 10 11 9 12 16 14 100 BFR 60 BFR 500 4 17 15 400 13 1 2 S3 C R3 G 300 18 29 200 21 3 22 M2 100 19 20 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 PORTATA FOLW RATE(l/h) /DEBIT (l/h) R KEY/LEGENDE 1 Gas valve / Soupape gaz 2 Condensation drain siphon / Syphon déchargement condensation 3 Boiler pump (not supplied) / Pompe bouilleur (non fournie) 4 Fan / Ventilateur 5 Heating probe (SM) / Sonde chauffage (SM) 6 Safety thermostat 95°C / Thermostat sécurité 95°C 7 Exhaust thermostat / Thermostat fumées 8 Primary exchanger / Échangeur primaire 9 Diaphragm / Diaphragme 10 Differential pressure switch / Pressostat différentiel 11 Water pressure transducer / Transducteur pression eau 12 Air relief valve / Purge automatique 13 Circulation pump / Pompe installation 14 Drain plug / Déchargement chaudière 15 Gas cock (not supplied) / Robinet gaz (non fourni) 16 Non return valve / Robinet d'arrêt 17 4 BAR safety valve / Soupape de sécurité 4 BARS SUPPLY/RETURN PIPE LOAD LOSSES PERTES DE CHARGE TUYAU DE REFOULEMENT/RETOUR INSTALLATIO 18 19 20 21 22 23 29 23 M Non return valve (not supplied) / Robinet d'arrêt (non fourni) Hydraulic compensator / Compensateur hydraulique Drain tap (not supplied) / Robinet de déchargement (non fourni) 8-liter expansion vessel / Vase expansion 8 litres Air relief valve (not supplied) / Purge automatique (non fourni) Oblique filter (not supplied) / Filtre oblique (non fourni) Series BT tank (optional) Bouilleur à accumulation série BT (en option) CONNECTIONS / RACCORDS M C.H. flow / Refoulement installation R C.H. return / Retour installation G Gas / Gaz S3 Condensation drain / Siphon déchargement condensation C System filling / Remplissage installation M2 Tank flow / Refoulement bouilleur R3 Tank return / Retour bouilleur HYDRAULIC COMPENSATOR LOAD LOSSES PERTES DE CHARGE DU COMPENSATEUR 300 45 60 BFR 250 40 60 BFR 100 BFR ∆p (mbar) 35 100 BFR 60 BFR 150 100 BFR 25 100 20 50 15 10 0 5 0 2 4 6 8 10 CAPACITY/ (m3/h) PORTATADEBIT (m3/h) 1 2 3 4 5 3/h) PORTATA (mDEBIT CAPACITY/ (m3/h) 6 BOILERCALDAIA SIDE / CÔTÉ CHAUDIÈRE LATO SYSTEM SIDE / CÔTÉ INSTALLATION LATO IMPIANTO 12 14 15 cod. 6151934 - 02/09 ∆p (mbar) 30 200