thermostat tp520

Transcription

thermostat tp520
THERMOSTAT TP520
IMPORTANT INFORMATION FOR SAFE USAGE
1
CONTROLS AND SETTINGS
2
DISPLAY STRUCTURE
2
SET
DAY AND TIME
CONTENT
3
EVENT TIME PROGRAMMING
4
TEMPERATURE RANGE PROGRAMMING
6
SCREENSAVER
6
SELECT OPERATION MODE
7
ALARM INDICATION
7
TECHNICAL DATA
8
LINE DIAGRAM
8
MENU STRUCTURE
8
WARRANTY
8
IMPORTANT INFORMATION FOR SAFE USAGE
Manufacturer's guarantee does not cover malfunctions caused by mechanical damage, improper installation, or exploitation for purposes, or
under conditions, not provided by the User- and Installation Manual. Please keep in mind that the Installation Manual and the Connection
Diagram are no replacement for the professional skill of the device installer. We recommend that you apply for professional service for the
thermostat and heating system installation. Only qualified electricians should perform the connections and power networking of the device.
Switch off power before connecting wiring to the thermostat or disconnecting the device for testing.
Introduction
Thank you for choosing the TP 520 electronic regulation device, the new intelligent heating control system. With this product you will see how
easy it is to maintain your comfort at a lower cost; it will take care of keeping your home warm and cozy all the time. Designed with innovation
and inspiration, the new thermostat is highly reliable, and easy to set and use.
Separate settings can be programmed for different times of the day, whether or in or out.
Application
The thermostat TP520 is designed to control underfloor heating systems (heating mats, sections, film heaters). The thermostat maintains
comfortable heating temperature and saves energy.
CONTROLS AND SETTINGS
Hands are used, if it is necessary to push
several butons together or push buttons for
longer time
PROG/ESC MODE/OK
1
4
1
-
2
PROG / ESC
3
MODE /OK
4
+
To start the described action, the marked
button must be pushed
3
2
decrease the values
enter the programm mode and EXIT
switch the indication & set limits and modes
increase the values
Temperature settings
DISPLAY STRUCTURE
Comfort modus, temp. adjustable
Economy modus, temp. adjustable
SET PROG DATE TIME TEMP
Programm modes
Operation modes
28,0 C
freeze protection mode
1
„WAKE UP“
constant temperature maintenance
2
„LEAVING HOME“
programm mode
3
„COMING HOME“
MO TU
heating on
4
„GOING TO SLEEP“
1
WE TH
2
FR
SA
3
SU
4
Other
Thermostat is locked
Confort temperature
Minimum temperature
Comming home
Wake up
Leaving home
Going to sleep
During the „COMFORT“ period the desired comfort temperature will be maintained.
MO
Monday
TU
Tuesday
WE
Wednesday
TH
Thursday
FR
Friday
SA
Saturday
SU
Sunday
During the „ECONOMY“ period the temperature will be reduced to the desired
minimum temperature to safe energy.
INSTALLATION
RESERVATION
Technical data are subject to change without notice. Changes, errors and printer's errors do not justify claims for damages. For safety
components and systems the relevant standards and regulations are to be observed, as well as the corresponding operating and installation
instructions.
2
ME SET DAY AND TIME
-
PROG/ESC MODE/OK
+
8 sec.
ENTER THE PROGRAMMING
1
2
Unlock the thermostat
TEMP
Press and hold the PROG/ESC button for 8 seconds
DATE & TIME
SET
19,0 C
WE
WE
PROG/ESC MODE/OK
PROG/ESC MODE/OK
8s
SET DAY
3
Press the MODE/OK button. The „Day
of the week symbol“ will start to blink
DATE
SET
4
DATE
SET
MO
Set the actual day of the week with the “+” or “–” button. Confirm
the selection with MODE/OK button.
TU
PROG/ESC MODE/OK
DATE
SET
TU
PROG/ESC MODE/OK
PROG/ESC MODE/OK
SET TIME
5
Set the required hour with the “+” or “–” button.
Confirm the selection with MODE/OK button.
Now the minutes procedure start.
TIME
SET
12 00
WE
PROG/ESC MODE/OK
6
Set the required minutes with the “+” or “–” button.
Confirm the selection with the MODE/OK button.
The „Day and time setting“ procedure is completed.
TEMP
TIME
SET
12 40
19,0 C
TU
WE
PROG/ESC MODE/OK
3
EVENT TIME PROGRAMMING
OGRAMMING
-
PROG/ESC MODE/OK
+
4 sec.
ENTER THE PROGRAMMING
1
2
Unlock the thermostat
TEMP
Press and hold the PROG/ESC button for 4 seconds
DATE & TIME
SET
19,0 C
WE
WE
PROG/ESC MODE/OK
PROG/ESC MODE/OK
4s
WAKE UP EVENT
1
3
Press the MODE/OK button.
The „Time symbol“ starts blinking.
SET PROG
TIME
Set your WAKE UP time with “+” and “–” buttons.
Confirm the selection with the MODE/OK button.
4
SET PROG
TIME
SET PROG
07 , 40
07 , 00
PROG/ESC MODE/OK
Press the MODE/OK button.
The time will start to blink
SET PROG
TIME
08 , 00
MO
7
PROG/ESC MODE/OK
1
Set your GO OUT time with “+” and “–” buttons.
Confirm the selection with the MODE/OK button.
SET PROG
PROG/ESC MODE/OK
LEAVING HOME EVENT
TIME
SET PROG
08 , 30
TEMP
08 , 30
MO
MO
2
07 , 40
PROG/ESC MODE/OK
2
6
TEMP
MO
1
PROG/ESC MODE/OK
Set the modus COMFORT
with the “+” or “–” button.
SET PROG
MO
1
1
TEMP
07 , 40
MO
MO
5
PROG/ESC MODE/OK
PROG/ESC MODE/OK
4
Set the modus ECONOMY
with “+” or “–” button.
SET PROG
TEMP
08 , 30
MO
2
2
8
2
PROG/ESC MODE/OK
EVENT TIME PROGRAMMING
OGRAMMING
-
+
PROG/ESC MODE/OK
4 sec.
COMING HOME EVENT
3
Press the MODE/OK button.
The time will start to blink
9
SET PROG
TIME
10
Set your COMING HOME time with “+” and “–” buttons.
Confirm the selection with the MODE/OK button.
SET PROG
19 , 00
TIME
SET PROG
19 , 30
MO
3
PROG/ESC MODE/OK
PROG/ESC MODE/OK
GOING TO SLEEP EVENT
4
Press the MODE/OK button.
The time will start to blink
12
SET PROG
TIME
13
Set your GOING TO SLEEP time with “+” and “–” buttons.
Confirm the selection with the MODE/OK button.
SET PROG
22 , 00
MO
SET PROG
TIME
TEMP
Set the modus ECONOMY
with “+” or “–” button.
TEMP
22 , 30
MO
4
14
SET PROG
22 , 30
22 , 30
MO
PROG/ESC MODE/OK
19 , 30
3
3
PROG/ESC MODE/OK
TEMP
MO
MO
3
Set the COMFORT modus
with “+” or “–” button.
SET PROG
TEMP
19 , 30
MO
PROG/ESC MODE/OK
11
MO
4
4
PROG/ESC MODE/OK
4
PROG/ESC MODE/OK
PROG/ESC MODE/OK
After setting the desired modus in the Step 14 press the MODE/OK button. The thermostat will proceed to set up the time for Wake-up event for
the next day of the week (TUESDAY) - please repeat the setting from step3 - 14 for all other days.
OPERATION SCHEME DESCRIPTION
ANTI - FREEZING
This mode is suitable to keep minimum positive temperature in the premise while nobody inside for a long time. The temperature is
adjustable from +5°C up to +12°C.
CONSTANT TEMPERATURE MODE
The thermostat constantly maintains the desired floor temperature. The temperature is adjustable from +12°C up to +35°C.
PROGRAM MODE
Depending on time and day of the week the thermostat automatically switches the „Comfort“ or „Economy“ floor temperature modus
depending your selections. The temperature is adjustable from +12°C up to +35°C.
DEFAULT SETTINGS
Day
Event
Time
Temperature level
Time
Saturday and Sunday
Temeparture level
Monday to Friday
1
2
3
4
7:00
8:00
19:00
22:00
7:00
8:00
19:00
22:00
5
TEMPERATURE
RANGE PROGRAMMING
ANGE
PROGRAMMING
-
PROG/ESC MODE/OK
+
8 sec.
ENTER THE PROGRAMMING
1
Unlock the thermostat
2
Press and hold the MODE/OK button for 8 seconds.
The symbol for the „ECONOMY MODUS“ apears and the
temperature starts with blinking.
TEMP
TEMP
SET
19,0 C
19,0 C
WE
WE
PROG/ESC MODE/OK
PROG/ESC MODE/OK
TEMPERATURE SETTINGS
3
During the „ECONOMY MODUS“ the temperature will be reduced to your desired minimum temperature. Set the desired
„ECONOMY MODUS TEMPERATURE“ with the “+” or “–” button. Confirm the selection with MODE/OK. Now the „COMFORT
MODUS TEMPERATURE“ could be adjusted on the same way. Confirm the selection with MODE/OK. Setup is completed and
the Display shows the actual temperature.
TEMP
SET
20,0 C
MO
SET
TEMP
SET
22,0 C
25,0 C
MO
PROG/ESC MODE/OK
TEMP
MO
PROG/ESC MODE/OK
PROG/ESC MODE/OK
SCREENSAVER
-
PROG/ESC MODE/OK
+
2 sec.
SELECT SCREENSAVER
1
Unlock the
thermostat
2
The default screensaver is “Floor temperature”.
Press and hold MODE/OK key for 2 seconds.
The screensaver will change to “Current time”
3
If you press and hold MODE/OK
key for 2 seconds again, the
screensaver will change back to
“Floor temperature”
TEMP
TEMP
TEMP
19,0 C
WE
PROG/ESC MODE/OK
7 40
WE
19,0 C
WE
PROG/ESC MODE/OK
6
PROG/ESC MODE/OK
ON SELECT
MODEOPERATION MODE
-
PROG/ESC MODE/OK
+
4 sec.
ENTER THE PROGRAMMING
1
Press and hold MODE/OK button for 4 seconds.
2 The operation scheme indicator will start to blink
Unlock the thermostat
TEMP
SET
19,0 C
19,0 C
WE
WE
PROG/ESC MODE/OK
PROG/ESC MODE/OK
4s
OPERATION MODE SELECTION
3
Set the operation scheme with the
“+” or “–” button.
4
Confirm the selection with MODE/OK.
The scheme is set.
SET
SET
19,0 C
19,0 C
WE
WE
PROG/ESC MODE/OK
PROG/ESC MODE/OK
ALARM INDICATION
ALARM INDICATION
1
Display apears in case if the heating system fails to heat the surface to more than
+5°C or in case of surface overheating by more than +45°C occurs.
TEMP
HI C
WE
PROG/ESC MODE/OK
2
Display apears in case of SENSOR FAILURE
TEMP
LO C
WE
-- -WE
PROG/ESC MODE/OK
7
PROG/ESC MODE/OK
TECHNICAL DATA
LINE DIAGRAM
Power supply
230VAC, 60Hz
Maximum load current
16A
Thermostat power consumption
450 mW
Weight
150 g
Dimensions
86x86x35 mm
IP rate
IP21/IP31
Protection class
II
Floor temperature sensor (TST02)
NTC 6,8 kOhm
Sensor cold lead length
2m
Ambient air temperature range
from +5°Ñ to +40°Ñ
Maximum humidity
80%
Temperature setting range
from +5°Ñ to +35°Ñ
Color
White
3
L
1 2
4
N
5
N
6
L
t
Sensor
230 VAC
Load (Heating)
MENU STRUCTURE
-
1x
PROG/ESC MODE/OK
-
+
Exit without saving
1x
PROG/ESC MODE/OK
+
Confirm settings
4 sec Event time programming
2 sec Screensaver selection
8 sec Set date
4 sec Operation mode selection
8 sec Set temperature
PRECAUTIONS
Switch off power from all wiring before installing, testing or replacing the thermostat. Only qualified electricians are allowed to work on electrical
connections and the electric supply of the device. Otherwise the warranty invalidates. Only use plastic wall mounting boxes for the thermostat
installation.
WARRANTY
The producer guarantees that the thermostat TP520 is free from defects caused by manufacturing techniques or by using of poor materials.
Warranty period – 2 years from date of purchase.
In case of a failure during the warranty period because of faulty manufacturing despite correct executed installation (according to manual) the
customer has the right to get the product repaired or replaced. The warranty does not cover any damages due to inadequate handling, damages
through third party fault, wrong installation (not following the manual) or its consequential damages. Please keep your receipt.
For any warranty claims you have to show your sales receipt.
CLAIMS
In case of failure during the warranty period please contact the manufacturer service center or the regional authorized representative.
ACCEPTANCE TEST CERTIFICATE
The thermostat TP520 passed the test.
Name:
Street:
ZIP code, city:
Country:
Phone:
E-Mail:
Date of purchase:
Installer:
Installation date:
installer:
Signature
Ducasa
Venezuela, 33
08019 Barcelona
8
Tel.: +34 932478630
Fax: +34 932455781
[email protected]
www.ducasa.com

Documents pareils