Photovoltaic, Ordering Information

Transcription

Photovoltaic, Ordering Information
Photovoltaic
Content Photovoltaic
Inverter
Page xx
DC-Disconnection
Page xx
DC-String Protection
Page xx
Surge Protection
Page xx
Energy Management
Page xx
1
Photovoltaic - Inverter
Inverter
- AC Nominal Output Power up to 4600 W
- Models IP65 for Outdoor use
- Transformerless Design
- RCMU and ENS integrated
- Maintenance-free
sg00210
2
±
Photovoltaic - Inverter
~
PV-Inverter Grid connected ISG
•
•
•
•
•
•
•
•
Transformerless Design
Equipped with MC3 plugs
High efficiency
Fanless
LCD display
GFCI integrated (RCMU)
Works with monitoring software
ENS meets VDE 0126-1-1
AC Output
MC3
Type Designation
Article No.
Units per package
ISG1I-1500/1
ISG1I-2000/1
ISG1I-2800/1
ISG1I-3300/1
ISG1I-4000/1
134753
134754
134755
135522
134756
1 / 14
1 / 14
1 / 12
1 / 12
1 / 12
ISG1O-4000/1
ISG3O-4600/1
134757
134758
1 / 12
1/6
Indoor series IP43
sg00210
1500 W
2000 W
2800 W
3300 W
4000 W
1 pair
1 pair
1 pair
2 pairs
2 pairs
Outdoor series IP65
sg00210
4000 W
4600 W
3 pairs
3 pairs
Explanactions:
MPP . . . . . . Maximum Power Point.
ENS . . . . . . Two independent main monitoring units with allocated all-pole switching devices.
GFCI . . . . . Ground Fault Current Interrupter.
RCMU . . . . Residual Current Monitoring Unit.
MC3 . . . . . . Multi Contact 3
3
±
Photovoltaic - Inverter ITALY
~
PV-Inverter Grid connected ISG...-I
•
•
•
•
•
•
•
•
•
Transformerless Design
Equipped with MC3 plugs
High efficiency
Fanless
LCD display
GFCI integrated (RCMU)
Works with monitoring software
ENS meets VDE 0126-1-1
Meets requirements of DK5940
AC Output
MC3
Type Designation
Article No.
Units per package
ISG1I-1500/1-I
ISG1I-2000/1-I
ISG1I-2800/1-I
ISG1I-3300/1-I
ISG1I-4000/1-I
134759
134830
134831
135523
134832
1 / 14
1 / 14
1 / 12
1 / 12
1 / 12
ISG1O-4000/1-I
ISG3O-4600/1-I
ISG1O-6000/1-I
134833
134834
134835
1 / 12
1/6
1/6
Indoor series IP43
sg00210
1500 W
2000 W
2800 W
3300 W
4000 W
1 pair
1 pair
1 pair
2 pairs
2 pairs
Outdoor series IP65
sg00210
4000 W
4600 W
6000 W
3 pairs
3 pairs
3 pairs
Explanations:
MPP . . . . . . Maximum Power Point
ENS . . . . . . Two independent main monitoring units with allocated all-pole switching devices.
Zwei voneinander unabhängige Einrichtungen zur Netzüberwachung mit zugeordneten allpoligen Schaltern in Reihe.
GFCI . . . . . Ground Fault Current Interrupter
RCMU . . . . Residual Current Monitoring Unit
MC3 . . . . . . Multi Contact 3
4
±
Photovoltaic - Inverter
~
Three-phase PV-Inverter grid connected I3G2O
•
•
•
•
•
•
•
•
•
•
•
•
•
Transformerless Design
With MC4 compatible plugs
Maximum efficiency ≥97.5%
Euro efficiency ≥97%
MPPT efficiency >99%
Lead-free, RoHS complied
Graphical LCD display
RCMU (GFCI) embedded
Works with monitoring software
ENS meets VDE 0126-1-1
2 MPPT-tracker
IP65, Outdoor
Grid interface regulation according VDE-AR-N 4105, VDE 0126-1-1/A1 (Germany), ENEL
Guide 2012 (Italy), CEI 0-21, RD1663 (Spain), G83/1-1, G59 Issue 2 (UK) and BDEW(MVD)
AC Output
Type Designation
Article No.
Units per package
I3G2O-10kW/2
I3G2O-15kW/2
I3G2O-20kW/2
167372
167373
167374
1
1
1
Outdoor series IP65
sg00210
10 kW
15 kW
20 kW
Explanactions:
MPP . . . . . . Maximum Power Point.
ENS . . . . . . Two independent main monitoring units with allocated all-pole switching devices.
GFCI . . . . . Ground Fault Current Interrupter.
RCMU . . . . Residual Current Monitoring Unit.
MC4 . . . . . . Multi Contact 4
5
Photovoltaic - DC-Disconnection
DC-Disconnectors
- Rated Voltage 1000 VDC
- Rated Operational Current up to 63 ADC
- P-SOL as component
wa_sg05409
wa_sg04709
- SOL as pre-wired Unit ready for connection
wa_sg00110
wa_sg06009
6
Photovoltaic - DC-Disconnection
DC
DC Switch-disconnector
DC Switch-disconnector P-SOL 2poles
• Rated operational voltage 1000 VDC
• Utilization category DC-21A
wa_sg05409, wa_sg04709
Rated op. current Ie
Type designation
Article No.
Units per package
20A
30A
63A
P-SOL20
P-SOL30
P-SOL60
120934
120935
120936
1
1
1
Connection diagrams:
PV Array
Unearthed system
Earthed system
PV Inverter
DC Switch-disconnector
DC Switch-disconnector SOL 2poles as pre-wired unit with protection
class II, degree of protection IP65
•
•
•
•
•
Rated operational voltage 1000 VDC
Utilization category DC-21A
Rated operational current Ie of 20or 30 A
Several versions – plugs MC3, MC4 or cable glands available
Versions for 2 and 4 Stings (INPUT) available
Ie
INPUT
OUTPUT
Type designation
Article No.
Units per package
1xMC4
1xMC4
1xMC4
1xMC4
SOL20/2MC4
SOL20/4MC4
SOL30/2MC4
SOL30/4MC4
120915
120916
120922
120923
1
1
1
1
120919
120926
1
1
wa_sg00110
MC4 version
20A
20A
30A
30A
2xMC4
4xMC4
2xMC4
4xMC4
Version with metrical cable glands
20A
30A
2xM12
2xM12
1xM16
1xM16
SOL20/2MW
SOL30/2MW
SOL20/2MC4
SOL30/2MC4
SOL20/2MV
SOL30/2MV
7
SOL20/4MC4
SOL30/4MC4
Photovoltaic - PV Off Switch, PV fireman's switch
PV Off Switch
•
•
•
•
Degree of protection IP 65
Tamper-proof to ISO 13850/EN 418
Reset by pulling or turning
Red enclosure upper section
Description
M22-SOL-PVT45PMPI11_HPL
Type designation
Article No.
Units per
package
150644
150645
150646
150647
150648
150673
152627
1
1
1
1
1
1
1
M22-SOL-PVPL11-230Q_HPL
Complete with guard ring, 1 NO, 1 NC
Complete with guard ring 2 NC
Surface mount enclosure, black/red cover
Guard ring, red, laser etched with SOLAR
Guard ring, red 1
Pushbutton laser etched with SOLAR
Complete 1 NO, 1 NC, can be sealed
M22-SOL-PVT45PMPI11Q
M22-SOL-PVT45PMPI02Q
M22-SOL-IR1Q
M22-SOL-XGPVQ
M22-XGPVQ
M22-SOL-PVT45P-MPIQ
M22-SOL-PVLPL11-230Q
PV fireman's switch SOL30-SAFETY
DC switch-disconnector
•
•
•
•
•
•
SOL30-SAFETY_HPL
Rated operational voltage 1000V
Utilization category DC-21A
Rated operational current Ie 30A
Remote release by undervoltage release 230V, 50Hz
Feedback of the switching status by auxiliary contacts 1NO and 1NC
Several versions - plugs MC3, MC4 or metric glands available
Ie
INPUT
OUTPUT
Type designation
Article No. Units per
package
30A
30A
30A
2xMC3
2xMC4
2xM12
1xMC3
1xMC4
1M16
SOL30-SAFETY/2MC3-U(230V50HZ)
SOL30-SAFETY/2MC4-U(230V50HZ)
SOL30-SAFETY/2MV-U(230V50HZ)
144121
144122
144123
Connection diagrams:
8
1
1
1
Photovoltaic - DC String Protection
DC-String Protection
- Rated Voltage up to 900 VDC
- Rated Current up to 63 ADC
- PKZ-SOL elektromechanical Circuit Breaker
wa_sg05409
wa_sg04709
- FCFDC10DI-SOL Fuse-Disconnector and Fuse-links
wa_sg00210
9
Photovoltaic - DC String Protection
DC
DC String circuit breaker
DC String circuit breaker PKZ-SOL 2poles
• Rated operational voltage 900 VDC
• Rated current In 12, 20, 30, 40, 50 and 63 A
• For permissible string short-circuit currents Isc of 5 up to 47 A
wa_sg05409, wa_sg04709
Ie
Isc
Type designation
Article No.
Units per package
4A
7A
12A
20A
30A
1.6-3A
2.6-5A
5-9A
9-15A
15-22A
PKZ-SOL4
PKZ-SOL7
PKZ-SOL12
PKZ-SOL20
PKZ-SOL30
144069
144120
120937
120938
120939
1
1
1
1
1
Connection diagrams:
PV String
Unearthed system
Earthed system
DC-Disconnection / PV Inverter
10
Photovoltaic - DC String Protection
C
DC
Fuse-Disconnector (empty) FCFDC10DI-..-SOL
• String protection of PV generator
• The visual tripping indicator indicates the tripped fuse-link
50-400 V flashing
400-1000 V permanent light
• Rated operational voltage 1000 VDC
• For cylindrical fuse-links photovoltaic application
• Lead-sealable
Number of Poles / Size
wa_sg00210
Type Designation
Article No.
Units per package
Size 10x38 FCFDC10DI, Rated operational current 25 A DC
without Visual Tripping Indicator
1
2
10x38
10x38
FCFDC10DI-1-SOL
FCFDC10DI-2-SOL
137256
137257
12 / 108
6 / 54
137258
137259
12 / 108
6 / 54
with Visual Tripping Indicator
1
2
10x38
10x38
FCFDC10DI-1L-SOL
FCFDC10DI-2L-SOL
Application Photovoltaic
Earthed System
FCFDC10DI-1-SOL
FCFDC10DI-1L-SOL
Unearthed System
FCFDC10DI-1-SOL
FCFDC10DI-2L-SOL
11
Photovoltaic - DC String Protection
C
Cylindrical Fuse-links
Size / Rated current / Rated voltage
Type Designation
Article No.
Units per package
Fuse-Links ASFLC10-..A-gPV-SOL Photolvoltaic application
SG11008
10x38
10x38
10x38
10x38
10x38
10x38
10x38
10x38
10x38
2A
4A
6A
8A
10 A
12 A
16 A
20 A
25 A
1000 V DC
1000 V DC
1000 V DC
1000 V DC
1000 V DC
1000 V DC
1000 V DC
1000 V DC
900 V DC
ASFLC10-2A-gPV-SOL
ASFLC10-4A-gPV-SOL
ASFLC10-6A-gPV-SOL
ASFLC10-8A-gPV-SOL
ASFLC10-10A-gPV-SOL
ASFLC10-12A-gPV-SOL
ASFLC10-16A-gPV-SOL
ASFLC10-20A-gPV-SOL
ASFLC10-25A-gPV-SOL
137279
137280
137281
137282
137283
137284
137285
137286
137287
PV-fuse-link selection:
À Maximum DC Operating voltage of the fuse-link must be:
1,2 x Voc of string
Á Rated current In of the fuse-link must be higher or equal than:
1,5 x Isc
Isc . . . . short circuit current of PV-module
Voc . . . open circuit voltage of string
12
10 / 500
10 / 500
10 / 500
10 / 500
10 / 500
10 / 500
10 / 500
10 / 500
10 / 500
Photovoltaic - Surge Protection
Surge Protection
DC - Photovoltaic systems up to 1000 VDC
AC
- For single and three phase Grid feeding
SG11009
SG11309
sg13309
SG13609
DC
AC
13
Photovoltaic - Surge Protection
DC
SPD-type T2 (Class C)
Max. Cont. Op. Volt. UC In (
Type Designation
Article No.
Units per package
Plug-in Surge Arrester SPPT2PA for Photovoltaic application
SG11009
For earthed systems
600 V DC
1000 V DC
SPPT2PA-600-2PE
SPPT2PA-1000-2PE
132663
132664
1 / 60
1 / 60
with auxiliary switch
1000 V DC
SPPT2PA-1000-2PE-AX
132666
1 / 60
600 V DC
1000 V DC
SPPT2PA-600-2+1PE
SPPT2PA-1000-2+1PE
132661
132662
1 / 40
1 / 40
with auxiliary switch
1000 V DC
SPPT2PA-1000-2+1PE-AX 132665
1 / 40
SPPT2PA-600
SPPT2PA-1000
SPPT2PA-1100
1
1
1
For unearthed systems
SG11309
Inserts for replacement
À
À
Á
600 V DC
1000 V DC
1100 V DC
VOC ≤ Uc:
132667
132668
132669
Open circuit voltage of PV-Generator shall be equal or less than maximum
continuous operating voltage of Surge Protective Device (SPD) to prevent its
damage.
VOC . . . . . .Open circuit voltage of PV-Generator.
UC . . . . . . .Maximum continuous operating voltage of SPD.
Attention: Even at switched off DC-Disconnector system stays under high voltage!
Before mounting ensure de-energizing and check zero-potential.
Earthed system
Unearthed system
SPPT2PA-600-2PE
SPPT2PA-1000-2PE(-AX)
SPPT2PA-600-2+1PE
SPPT2PA-1000-2+1PE(-AX)
L-
L-
14
L+
Photovoltaic - Surge Protection
DC
SPD-type T2 (Class C)
PV Surge Protective Device SOL-SP as pre-wired unit with protection
class II, degree of protection IP65
•
•
•
•
•
For unearthed Photovoltaic systems up to 600 VDC and 1000 VDC
Rated operational current Ie=30 ADC at versions MC3, MC4
Rated operational current Ie=32 ADC at version with metrical cable glands
PE-conductor has to be connected direct to the surge protective device
PE terminal – metrical cable gland M16 in the enclosure for PE-conductor
Voc
wa_sg06509
INPUT
OUTPUT
Type designation
Article No.
Units per package
1xMC3
1xMC3
SOL-SP600U/2MC3
SOL-SP1000U/2MC3
144124
144127
1
1
1xMC4
1xMC4
SOL-SP600U/2MC4
SOL-SP1000U/2MC5
144125
144128
1
1
144126
144129
1
1
MC3 version
600VDC 2xMC3
1000VDC 2xMC3
MC4 version
600VDC 2xMC4
1000VDC 2xMC4
Version with metrical cable glands
600VDC 2xM16
1000VDC 2xM16
VOC ≤ Uc:
1xM16
1xM16
SOL-SP600U/2MV
SOL-SP1000U/2MV
Open circuit voltage of PV-Generator shall be equal or less than maximum
continuous operating voltage of Surge Protective Device (SPD) to prevent its
damage.
VOC . . . . . .Open circuit voltage of PV-Generator.
UC . . . . . . .Maximum continuous operating voltage of SPD.
Attention: Even at switched off DC-Disconnector system stays under high voltage!
Before mounting ensure de-energizing and check zero-potential.
Connection Example:
Protected Area
DC-Disconnection
PE-conductor has to be
layed seperately to conductors of protected area
PV Inverter
15
Photovoltaic - Surge Protection
AC
SPD-type T2 (Class C)
sg13309
Max. Cont. Op. Volt. UC In (8/20)µs
Type Designation
Article No.
Units per package
131755
131756
131757
131758
131759
131760
131761
131762
131773
131774
12 / 120
1 / 60
1 / 40
1 / 30
12 / 120
1 / 60
1 / 40
1 / 30
1 / 60
1 / 30
SPMT2PA-280
SPMT2PA-335
SPMT2PA-NPE
131778
131779
131783
4 / 120
4 / 120
4 / 120
Type designation
Article No.
Units per package
ASAUXSC-SPM
131785
4 / 120
131784
12 / 120
Plug-in surge arrester SPMT2PA, 1- to 4-pole
1pole
2pole
3pole
4pole
1pole
2pole
3pole
4pole
1+1p
3+1p
SG13109
280VAC
280VAC
280VAC
280VAC
335VAC
335VAC
335VAC
335VAC
–
–
1x20kA
2x20kA
3x20kA
4x20kA
1x20kA
2x20kA
3x20kA
4x20kA
–
–
SPMT2PA-280/1
SPMT2PA-280/2
SPMT2PA-280/3
SPMT2PA-280/4
SPMT2PA-335/1
SPMT2PA-335/2
SPMT2PA-335/3
SPMT2PA-335/4
SPMT2PA-1+NPE
SPMT2PA-3+NPE
Inserts SPMT2PA for replacement
Insert 1-pole
Insert 280VAC
Insert 335VAC
Insert N-PE 260VAC
20kA
20kA
30kA
Description
SG12809
Auxiliary Switch
for SPMT2PA
SG12909
Lead-through terminal for SPMT2PA
ASLTT-63
16
Photovoltaic - Energy Management
Energy Management
- Energy sensors AC up to 100A
- Room-Manager with Energy visualisation
- Adapter RS232 to USB Interface
Wireless Data transmission
rf09410
rf05410
Data transmission via Data cable with Adapter RS232 to USB
rf01506
17
Photovoltaic - RF System - Flush-mounted devices
Design
RF05410
Type designation
Article No.
Units per package
Energy sensor
• The "energy sensor" is used to record the solar energy converted in the PV inverter and
to forward this information to the Room-Manager equipped with "Energy management
function". This type of device is used for capacities of 3-3680W. It is used to determine
current (A), voltage (V), power (kW) and energy (kWh). The "energy sensor" is preferably
connected at the feeding point in the electrical system. The device is mounted in the
switch box, the branch-off box, or the installation box.
• Warning: The device is not calibrated and is thus not suitable for billing purposes!
RF06510
0,42VA/230VAC,
Measuring range 3-3680 W
(max. 16A)
CEMU-01/04
Design
Type designation
136477
Article No.
1
Units per package
Energy sensor with external sensor
• The "energy sensor with external sensor" is used to record the solar energy converted in
the PV inverter and to forward this information to the Room-Manager equipped with
"Energy management function". This type of device is used for larger capacities of 15W 23kW. It is used to determine current (A), voltage (V), power (kW) and energy (kWh). The
energy sensor's external sensor is connected through the supply line, preferably at the
feeding point in the electrical system. The device is mounted in the switch box, the
branch-off box, or the installation box.
• Warning: The device is not calibrated and is thus not suitable for billing purposes!
0,42VA/230VAC,
CEMU-01/05
Measuring range ext. sensor
15 W - 23 kW (max. 100A)
18
136476
1
Photovoltaic - RF System - Surface mounted devices
Design
rf09410
Type designation
Article No.
Units per package
Room-Manager: white, 1 VA, 230 VAC, without Bluetooth
• The "Room-Manager" is a central display and operating device. In connection with the
energy sensors (with or without external sensors), the solar energy emitted by the
PV inverter is displayed. In addition, the device offers thoroughly tested applications such
as heating and cooling for individual rooms, ventilation, time functions, shading, safety,
etc., to achieve a modern electrical installation. The "Room-Manager" communicates with
all devices that are part of the Eaton RF system. The most modern touch- button sensor
technology makes it possible for the user to easily operate the system on site and to
program all parameters (e.g. time settings, temperature, etc.) The back-lighted graphic
display guarantees a simple and concise display of the most important information for
the end client. The device is to be surface-mounted on a wall. Alternatively, the device
can be affixed to a 55 mm or 68 mm switch box, branch-off box, or installation box.
The integrated IR interface is used for system updates or to expand functions. The device
feed is carried out through the power supply line.
• Note: In order to obtain the exact measurement and display of the temperature, use the
reference measuring device to determine the difference and then adjust the "Offset" in
the MRF system.
Room-Manager: Energy management
4 counter inputs (impulse counters or energy sensor), e.g. solar energy, electrical energy,
water, gas, etc.
Per input: Unit of measurement, count constant, base value, costs, CO2 emissions
Per input: Graphic display of progression during diverse time periods
(1 day, 7 days, 30 days, 12 months)
The display is adjustable
Each input allows 1 threshold value followed by an "action in case thisvalue is exceeded";
the limit value can be adjusted
Overview display of up to 3 different counter inputs
Room-Manager: Comfort management
2 local buttons, freely assignable
3 rooms for 1-level heating/cooling, adjustable time-temperature programme, target/actual
temperature display, operating modes can be selected, integration of 3 window contacts
per room
1 1-level ventilation, adjustable time programme, operating modes can be selected,
manual control
1 time and date display, automatic switch for daylight saving times in summer/winter
10 inputs, displays for temperature, humidity, light intensity, etc.
10 outputs, display and operation of electrical consumers
1 outdoor temperature, max./min/trend display, re-setting of the trend display
3 timers, adjustable time programme, operating modes can be selected, manual control
3 shading units with time programme and manual control, time programme is adjustable
1 holiday function, time and date are adjustable
1 presence simulator, settings adjustable for a max. of 10 consumers, time and activation
function
3 logic operations with 2 inputs each, AND/OR connection
2 scenes with 6 functions each, function is adjustable
1 request for total heating
1 request for total cooling
Battery status display and advance warning for all battery-operated devices that are
assigned to the Room-Manager
Software update conducted via IRDA
Adjustable password protection
Multi-language menu (depending upon article number)
General settings
Room-Manager: Safety management (additional function)
This fee-based function can be activated at www.moeller.at
2 separate areas can be monitored (e.g. indoors, outdoors, upper floor, etc.)
2 areas can be activated/deactivated individually or together
3 inputs to activate/deactivate, alternatively 4-digit codes can be used
10 additional inputs for safety (motion detectors, window contacts, sensors, etc.)
2 outputs for "Safety" alert purposes (sirens, flashing lights)
5 additional inputs for smoke detectors, regardless of whether Safety function is
activated/deactivated
1 output for "Smoke detector" alert (sirens, flashing lights)
Adjustable time delay for activation/deactivation upon entering/leaving a room
Attention: This is a warning function, not a smoke/fire alarm or other alarm system!!!
GB,NO,SE,FI
GB,NL,FR,DE,IT
GB,RO,HU,PL,TR
GB,DE,CZ,GR
CRMA-00/03
CRMA-00/04
CRMA-00/05
CRMA-00/06
19
118783
118784
118785
118786
1
1
1
1
Photovoltaic - Energy Management
Design
RF01506
Type designation
Article No.
Units per package
USB-RS232 Adapter cable
• The "USB-RS232 Adapter cable" is used to connect the PV inverter (with RS232 interface)
to the laptop/notebook/PC (with USB interface). In this manner, all data from the PV
inverter can be evaluated by the "Watch-SOL Software".
CRSZ-00/03
Design
RF03107
Type designation
104932
Article No.
1
Units per package
DIN-rail-clip
• The energy sensor (with or without external sensor) can be attached to the "DIN-rail-clip"
in order to snap this combination onto any possible DIN-rail. Note: Do not use metal distribution boards under any circumstances since metal can block the radio signal!!!
Info: The price and the order number refer to one "DIN-rail-clip" unit. We cannot
deliver single units! Therefore, please order at least one package (10 units) or a multiple
thereof.
CMMZ-00/30
20
135529
10