Photovoltaic, Ordering Information
Transcription
Photovoltaic, Ordering Information
Photovoltaic Content Photovoltaic Inverter Page xx DC-Disconnection Page xx DC-String Protection Page xx Surge Protection Page xx Energy Management Page xx 1 Photovoltaic - Inverter Inverter - AC Nominal Output Power up to 4600 W - Models IP65 for Outdoor use - Transformerless Design - RCMU and ENS integrated - Maintenance-free sg00210 2 ± Photovoltaic - Inverter ~ PV-Inverter Grid connected ISG • • • • • • • • Transformerless Design Equipped with MC3 plugs High efficiency Fanless LCD display GFCI integrated (RCMU) Works with monitoring software ENS meets VDE 0126-1-1 AC Output MC3 Type Designation Article No. Units per package ISG1I-1500/1 ISG1I-2000/1 ISG1I-2800/1 ISG1I-3300/1 ISG1I-4000/1 134753 134754 134755 135522 134756 1 / 14 1 / 14 1 / 12 1 / 12 1 / 12 ISG1O-4000/1 ISG3O-4600/1 134757 134758 1 / 12 1/6 Indoor series IP43 sg00210 1500 W 2000 W 2800 W 3300 W 4000 W 1 pair 1 pair 1 pair 2 pairs 2 pairs Outdoor series IP65 sg00210 4000 W 4600 W 3 pairs 3 pairs Explanactions: MPP . . . . . . Maximum Power Point. ENS . . . . . . Two independent main monitoring units with allocated all-pole switching devices. GFCI . . . . . Ground Fault Current Interrupter. RCMU . . . . Residual Current Monitoring Unit. MC3 . . . . . . Multi Contact 3 3 ± Photovoltaic - Inverter ITALY ~ PV-Inverter Grid connected ISG...-I • • • • • • • • • Transformerless Design Equipped with MC3 plugs High efficiency Fanless LCD display GFCI integrated (RCMU) Works with monitoring software ENS meets VDE 0126-1-1 Meets requirements of DK5940 AC Output MC3 Type Designation Article No. Units per package ISG1I-1500/1-I ISG1I-2000/1-I ISG1I-2800/1-I ISG1I-3300/1-I ISG1I-4000/1-I 134759 134830 134831 135523 134832 1 / 14 1 / 14 1 / 12 1 / 12 1 / 12 ISG1O-4000/1-I ISG3O-4600/1-I ISG1O-6000/1-I 134833 134834 134835 1 / 12 1/6 1/6 Indoor series IP43 sg00210 1500 W 2000 W 2800 W 3300 W 4000 W 1 pair 1 pair 1 pair 2 pairs 2 pairs Outdoor series IP65 sg00210 4000 W 4600 W 6000 W 3 pairs 3 pairs 3 pairs Explanations: MPP . . . . . . Maximum Power Point ENS . . . . . . Two independent main monitoring units with allocated all-pole switching devices. Zwei voneinander unabhängige Einrichtungen zur Netzüberwachung mit zugeordneten allpoligen Schaltern in Reihe. GFCI . . . . . Ground Fault Current Interrupter RCMU . . . . Residual Current Monitoring Unit MC3 . . . . . . Multi Contact 3 4 ± Photovoltaic - Inverter ~ Three-phase PV-Inverter grid connected I3G2O • • • • • • • • • • • • • Transformerless Design With MC4 compatible plugs Maximum efficiency ≥97.5% Euro efficiency ≥97% MPPT efficiency >99% Lead-free, RoHS complied Graphical LCD display RCMU (GFCI) embedded Works with monitoring software ENS meets VDE 0126-1-1 2 MPPT-tracker IP65, Outdoor Grid interface regulation according VDE-AR-N 4105, VDE 0126-1-1/A1 (Germany), ENEL Guide 2012 (Italy), CEI 0-21, RD1663 (Spain), G83/1-1, G59 Issue 2 (UK) and BDEW(MVD) AC Output Type Designation Article No. Units per package I3G2O-10kW/2 I3G2O-15kW/2 I3G2O-20kW/2 167372 167373 167374 1 1 1 Outdoor series IP65 sg00210 10 kW 15 kW 20 kW Explanactions: MPP . . . . . . Maximum Power Point. ENS . . . . . . Two independent main monitoring units with allocated all-pole switching devices. GFCI . . . . . Ground Fault Current Interrupter. RCMU . . . . Residual Current Monitoring Unit. MC4 . . . . . . Multi Contact 4 5 Photovoltaic - DC-Disconnection DC-Disconnectors - Rated Voltage 1000 VDC - Rated Operational Current up to 63 ADC - P-SOL as component wa_sg05409 wa_sg04709 - SOL as pre-wired Unit ready for connection wa_sg00110 wa_sg06009 6 Photovoltaic - DC-Disconnection DC DC Switch-disconnector DC Switch-disconnector P-SOL 2poles • Rated operational voltage 1000 VDC • Utilization category DC-21A wa_sg05409, wa_sg04709 Rated op. current Ie Type designation Article No. Units per package 20A 30A 63A P-SOL20 P-SOL30 P-SOL60 120934 120935 120936 1 1 1 Connection diagrams: PV Array Unearthed system Earthed system PV Inverter DC Switch-disconnector DC Switch-disconnector SOL 2poles as pre-wired unit with protection class II, degree of protection IP65 • • • • • Rated operational voltage 1000 VDC Utilization category DC-21A Rated operational current Ie of 20or 30 A Several versions – plugs MC3, MC4 or cable glands available Versions for 2 and 4 Stings (INPUT) available Ie INPUT OUTPUT Type designation Article No. Units per package 1xMC4 1xMC4 1xMC4 1xMC4 SOL20/2MC4 SOL20/4MC4 SOL30/2MC4 SOL30/4MC4 120915 120916 120922 120923 1 1 1 1 120919 120926 1 1 wa_sg00110 MC4 version 20A 20A 30A 30A 2xMC4 4xMC4 2xMC4 4xMC4 Version with metrical cable glands 20A 30A 2xM12 2xM12 1xM16 1xM16 SOL20/2MW SOL30/2MW SOL20/2MC4 SOL30/2MC4 SOL20/2MV SOL30/2MV 7 SOL20/4MC4 SOL30/4MC4 Photovoltaic - PV Off Switch, PV fireman's switch PV Off Switch • • • • Degree of protection IP 65 Tamper-proof to ISO 13850/EN 418 Reset by pulling or turning Red enclosure upper section Description M22-SOL-PVT45PMPI11_HPL Type designation Article No. Units per package 150644 150645 150646 150647 150648 150673 152627 1 1 1 1 1 1 1 M22-SOL-PVPL11-230Q_HPL Complete with guard ring, 1 NO, 1 NC Complete with guard ring 2 NC Surface mount enclosure, black/red cover Guard ring, red, laser etched with SOLAR Guard ring, red 1 Pushbutton laser etched with SOLAR Complete 1 NO, 1 NC, can be sealed M22-SOL-PVT45PMPI11Q M22-SOL-PVT45PMPI02Q M22-SOL-IR1Q M22-SOL-XGPVQ M22-XGPVQ M22-SOL-PVT45P-MPIQ M22-SOL-PVLPL11-230Q PV fireman's switch SOL30-SAFETY DC switch-disconnector • • • • • • SOL30-SAFETY_HPL Rated operational voltage 1000V Utilization category DC-21A Rated operational current Ie 30A Remote release by undervoltage release 230V, 50Hz Feedback of the switching status by auxiliary contacts 1NO and 1NC Several versions - plugs MC3, MC4 or metric glands available Ie INPUT OUTPUT Type designation Article No. Units per package 30A 30A 30A 2xMC3 2xMC4 2xM12 1xMC3 1xMC4 1M16 SOL30-SAFETY/2MC3-U(230V50HZ) SOL30-SAFETY/2MC4-U(230V50HZ) SOL30-SAFETY/2MV-U(230V50HZ) 144121 144122 144123 Connection diagrams: 8 1 1 1 Photovoltaic - DC String Protection DC-String Protection - Rated Voltage up to 900 VDC - Rated Current up to 63 ADC - PKZ-SOL elektromechanical Circuit Breaker wa_sg05409 wa_sg04709 - FCFDC10DI-SOL Fuse-Disconnector and Fuse-links wa_sg00210 9 Photovoltaic - DC String Protection DC DC String circuit breaker DC String circuit breaker PKZ-SOL 2poles • Rated operational voltage 900 VDC • Rated current In 12, 20, 30, 40, 50 and 63 A • For permissible string short-circuit currents Isc of 5 up to 47 A wa_sg05409, wa_sg04709 Ie Isc Type designation Article No. Units per package 4A 7A 12A 20A 30A 1.6-3A 2.6-5A 5-9A 9-15A 15-22A PKZ-SOL4 PKZ-SOL7 PKZ-SOL12 PKZ-SOL20 PKZ-SOL30 144069 144120 120937 120938 120939 1 1 1 1 1 Connection diagrams: PV String Unearthed system Earthed system DC-Disconnection / PV Inverter 10 Photovoltaic - DC String Protection C DC Fuse-Disconnector (empty) FCFDC10DI-..-SOL • String protection of PV generator • The visual tripping indicator indicates the tripped fuse-link 50-400 V flashing 400-1000 V permanent light • Rated operational voltage 1000 VDC • For cylindrical fuse-links photovoltaic application • Lead-sealable Number of Poles / Size wa_sg00210 Type Designation Article No. Units per package Size 10x38 FCFDC10DI, Rated operational current 25 A DC without Visual Tripping Indicator 1 2 10x38 10x38 FCFDC10DI-1-SOL FCFDC10DI-2-SOL 137256 137257 12 / 108 6 / 54 137258 137259 12 / 108 6 / 54 with Visual Tripping Indicator 1 2 10x38 10x38 FCFDC10DI-1L-SOL FCFDC10DI-2L-SOL Application Photovoltaic Earthed System FCFDC10DI-1-SOL FCFDC10DI-1L-SOL Unearthed System FCFDC10DI-1-SOL FCFDC10DI-2L-SOL 11 Photovoltaic - DC String Protection C Cylindrical Fuse-links Size / Rated current / Rated voltage Type Designation Article No. Units per package Fuse-Links ASFLC10-..A-gPV-SOL Photolvoltaic application SG11008 10x38 10x38 10x38 10x38 10x38 10x38 10x38 10x38 10x38 2A 4A 6A 8A 10 A 12 A 16 A 20 A 25 A 1000 V DC 1000 V DC 1000 V DC 1000 V DC 1000 V DC 1000 V DC 1000 V DC 1000 V DC 900 V DC ASFLC10-2A-gPV-SOL ASFLC10-4A-gPV-SOL ASFLC10-6A-gPV-SOL ASFLC10-8A-gPV-SOL ASFLC10-10A-gPV-SOL ASFLC10-12A-gPV-SOL ASFLC10-16A-gPV-SOL ASFLC10-20A-gPV-SOL ASFLC10-25A-gPV-SOL 137279 137280 137281 137282 137283 137284 137285 137286 137287 PV-fuse-link selection: À Maximum DC Operating voltage of the fuse-link must be: 1,2 x Voc of string Á Rated current In of the fuse-link must be higher or equal than: 1,5 x Isc Isc . . . . short circuit current of PV-module Voc . . . open circuit voltage of string 12 10 / 500 10 / 500 10 / 500 10 / 500 10 / 500 10 / 500 10 / 500 10 / 500 10 / 500 Photovoltaic - Surge Protection Surge Protection DC - Photovoltaic systems up to 1000 VDC AC - For single and three phase Grid feeding SG11009 SG11309 sg13309 SG13609 DC AC 13 Photovoltaic - Surge Protection DC SPD-type T2 (Class C) Max. Cont. Op. Volt. UC In ( Type Designation Article No. Units per package Plug-in Surge Arrester SPPT2PA for Photovoltaic application SG11009 For earthed systems 600 V DC 1000 V DC SPPT2PA-600-2PE SPPT2PA-1000-2PE 132663 132664 1 / 60 1 / 60 with auxiliary switch 1000 V DC SPPT2PA-1000-2PE-AX 132666 1 / 60 600 V DC 1000 V DC SPPT2PA-600-2+1PE SPPT2PA-1000-2+1PE 132661 132662 1 / 40 1 / 40 with auxiliary switch 1000 V DC SPPT2PA-1000-2+1PE-AX 132665 1 / 40 SPPT2PA-600 SPPT2PA-1000 SPPT2PA-1100 1 1 1 For unearthed systems SG11309 Inserts for replacement À À Á 600 V DC 1000 V DC 1100 V DC VOC ≤ Uc: 132667 132668 132669 Open circuit voltage of PV-Generator shall be equal or less than maximum continuous operating voltage of Surge Protective Device (SPD) to prevent its damage. VOC . . . . . .Open circuit voltage of PV-Generator. UC . . . . . . .Maximum continuous operating voltage of SPD. Attention: Even at switched off DC-Disconnector system stays under high voltage! Before mounting ensure de-energizing and check zero-potential. Earthed system Unearthed system SPPT2PA-600-2PE SPPT2PA-1000-2PE(-AX) SPPT2PA-600-2+1PE SPPT2PA-1000-2+1PE(-AX) L- L- 14 L+ Photovoltaic - Surge Protection DC SPD-type T2 (Class C) PV Surge Protective Device SOL-SP as pre-wired unit with protection class II, degree of protection IP65 • • • • • For unearthed Photovoltaic systems up to 600 VDC and 1000 VDC Rated operational current Ie=30 ADC at versions MC3, MC4 Rated operational current Ie=32 ADC at version with metrical cable glands PE-conductor has to be connected direct to the surge protective device PE terminal – metrical cable gland M16 in the enclosure for PE-conductor Voc wa_sg06509 INPUT OUTPUT Type designation Article No. Units per package 1xMC3 1xMC3 SOL-SP600U/2MC3 SOL-SP1000U/2MC3 144124 144127 1 1 1xMC4 1xMC4 SOL-SP600U/2MC4 SOL-SP1000U/2MC5 144125 144128 1 1 144126 144129 1 1 MC3 version 600VDC 2xMC3 1000VDC 2xMC3 MC4 version 600VDC 2xMC4 1000VDC 2xMC4 Version with metrical cable glands 600VDC 2xM16 1000VDC 2xM16 VOC ≤ Uc: 1xM16 1xM16 SOL-SP600U/2MV SOL-SP1000U/2MV Open circuit voltage of PV-Generator shall be equal or less than maximum continuous operating voltage of Surge Protective Device (SPD) to prevent its damage. VOC . . . . . .Open circuit voltage of PV-Generator. UC . . . . . . .Maximum continuous operating voltage of SPD. Attention: Even at switched off DC-Disconnector system stays under high voltage! Before mounting ensure de-energizing and check zero-potential. Connection Example: Protected Area DC-Disconnection PE-conductor has to be layed seperately to conductors of protected area PV Inverter 15 Photovoltaic - Surge Protection AC SPD-type T2 (Class C) sg13309 Max. Cont. Op. Volt. UC In (8/20)µs Type Designation Article No. Units per package 131755 131756 131757 131758 131759 131760 131761 131762 131773 131774 12 / 120 1 / 60 1 / 40 1 / 30 12 / 120 1 / 60 1 / 40 1 / 30 1 / 60 1 / 30 SPMT2PA-280 SPMT2PA-335 SPMT2PA-NPE 131778 131779 131783 4 / 120 4 / 120 4 / 120 Type designation Article No. Units per package ASAUXSC-SPM 131785 4 / 120 131784 12 / 120 Plug-in surge arrester SPMT2PA, 1- to 4-pole 1pole 2pole 3pole 4pole 1pole 2pole 3pole 4pole 1+1p 3+1p SG13109 280VAC 280VAC 280VAC 280VAC 335VAC 335VAC 335VAC 335VAC – – 1x20kA 2x20kA 3x20kA 4x20kA 1x20kA 2x20kA 3x20kA 4x20kA – – SPMT2PA-280/1 SPMT2PA-280/2 SPMT2PA-280/3 SPMT2PA-280/4 SPMT2PA-335/1 SPMT2PA-335/2 SPMT2PA-335/3 SPMT2PA-335/4 SPMT2PA-1+NPE SPMT2PA-3+NPE Inserts SPMT2PA for replacement Insert 1-pole Insert 280VAC Insert 335VAC Insert N-PE 260VAC 20kA 20kA 30kA Description SG12809 Auxiliary Switch for SPMT2PA SG12909 Lead-through terminal for SPMT2PA ASLTT-63 16 Photovoltaic - Energy Management Energy Management - Energy sensors AC up to 100A - Room-Manager with Energy visualisation - Adapter RS232 to USB Interface Wireless Data transmission rf09410 rf05410 Data transmission via Data cable with Adapter RS232 to USB rf01506 17 Photovoltaic - RF System - Flush-mounted devices Design RF05410 Type designation Article No. Units per package Energy sensor • The "energy sensor" is used to record the solar energy converted in the PV inverter and to forward this information to the Room-Manager equipped with "Energy management function". This type of device is used for capacities of 3-3680W. It is used to determine current (A), voltage (V), power (kW) and energy (kWh). The "energy sensor" is preferably connected at the feeding point in the electrical system. The device is mounted in the switch box, the branch-off box, or the installation box. • Warning: The device is not calibrated and is thus not suitable for billing purposes! RF06510 0,42VA/230VAC, Measuring range 3-3680 W (max. 16A) CEMU-01/04 Design Type designation 136477 Article No. 1 Units per package Energy sensor with external sensor • The "energy sensor with external sensor" is used to record the solar energy converted in the PV inverter and to forward this information to the Room-Manager equipped with "Energy management function". This type of device is used for larger capacities of 15W 23kW. It is used to determine current (A), voltage (V), power (kW) and energy (kWh). The energy sensor's external sensor is connected through the supply line, preferably at the feeding point in the electrical system. The device is mounted in the switch box, the branch-off box, or the installation box. • Warning: The device is not calibrated and is thus not suitable for billing purposes! 0,42VA/230VAC, CEMU-01/05 Measuring range ext. sensor 15 W - 23 kW (max. 100A) 18 136476 1 Photovoltaic - RF System - Surface mounted devices Design rf09410 Type designation Article No. Units per package Room-Manager: white, 1 VA, 230 VAC, without Bluetooth • The "Room-Manager" is a central display and operating device. In connection with the energy sensors (with or without external sensors), the solar energy emitted by the PV inverter is displayed. In addition, the device offers thoroughly tested applications such as heating and cooling for individual rooms, ventilation, time functions, shading, safety, etc., to achieve a modern electrical installation. The "Room-Manager" communicates with all devices that are part of the Eaton RF system. The most modern touch- button sensor technology makes it possible for the user to easily operate the system on site and to program all parameters (e.g. time settings, temperature, etc.) The back-lighted graphic display guarantees a simple and concise display of the most important information for the end client. The device is to be surface-mounted on a wall. Alternatively, the device can be affixed to a 55 mm or 68 mm switch box, branch-off box, or installation box. The integrated IR interface is used for system updates or to expand functions. The device feed is carried out through the power supply line. • Note: In order to obtain the exact measurement and display of the temperature, use the reference measuring device to determine the difference and then adjust the "Offset" in the MRF system. Room-Manager: Energy management 4 counter inputs (impulse counters or energy sensor), e.g. solar energy, electrical energy, water, gas, etc. Per input: Unit of measurement, count constant, base value, costs, CO2 emissions Per input: Graphic display of progression during diverse time periods (1 day, 7 days, 30 days, 12 months) The display is adjustable Each input allows 1 threshold value followed by an "action in case thisvalue is exceeded"; the limit value can be adjusted Overview display of up to 3 different counter inputs Room-Manager: Comfort management 2 local buttons, freely assignable 3 rooms for 1-level heating/cooling, adjustable time-temperature programme, target/actual temperature display, operating modes can be selected, integration of 3 window contacts per room 1 1-level ventilation, adjustable time programme, operating modes can be selected, manual control 1 time and date display, automatic switch for daylight saving times in summer/winter 10 inputs, displays for temperature, humidity, light intensity, etc. 10 outputs, display and operation of electrical consumers 1 outdoor temperature, max./min/trend display, re-setting of the trend display 3 timers, adjustable time programme, operating modes can be selected, manual control 3 shading units with time programme and manual control, time programme is adjustable 1 holiday function, time and date are adjustable 1 presence simulator, settings adjustable for a max. of 10 consumers, time and activation function 3 logic operations with 2 inputs each, AND/OR connection 2 scenes with 6 functions each, function is adjustable 1 request for total heating 1 request for total cooling Battery status display and advance warning for all battery-operated devices that are assigned to the Room-Manager Software update conducted via IRDA Adjustable password protection Multi-language menu (depending upon article number) General settings Room-Manager: Safety management (additional function) This fee-based function can be activated at www.moeller.at 2 separate areas can be monitored (e.g. indoors, outdoors, upper floor, etc.) 2 areas can be activated/deactivated individually or together 3 inputs to activate/deactivate, alternatively 4-digit codes can be used 10 additional inputs for safety (motion detectors, window contacts, sensors, etc.) 2 outputs for "Safety" alert purposes (sirens, flashing lights) 5 additional inputs for smoke detectors, regardless of whether Safety function is activated/deactivated 1 output for "Smoke detector" alert (sirens, flashing lights) Adjustable time delay for activation/deactivation upon entering/leaving a room Attention: This is a warning function, not a smoke/fire alarm or other alarm system!!! GB,NO,SE,FI GB,NL,FR,DE,IT GB,RO,HU,PL,TR GB,DE,CZ,GR CRMA-00/03 CRMA-00/04 CRMA-00/05 CRMA-00/06 19 118783 118784 118785 118786 1 1 1 1 Photovoltaic - Energy Management Design RF01506 Type designation Article No. Units per package USB-RS232 Adapter cable • The "USB-RS232 Adapter cable" is used to connect the PV inverter (with RS232 interface) to the laptop/notebook/PC (with USB interface). In this manner, all data from the PV inverter can be evaluated by the "Watch-SOL Software". CRSZ-00/03 Design RF03107 Type designation 104932 Article No. 1 Units per package DIN-rail-clip • The energy sensor (with or without external sensor) can be attached to the "DIN-rail-clip" in order to snap this combination onto any possible DIN-rail. Note: Do not use metal distribution boards under any circumstances since metal can block the radio signal!!! Info: The price and the order number refer to one "DIN-rail-clip" unit. We cannot deliver single units! Therefore, please order at least one package (10 units) or a multiple thereof. CMMZ-00/30 20 135529 10