KL 1500 HAL KL 1500 H
Transcription
KL 1500 HAL KL 1500 H
KL 1500 HAL KL 1500 H Gebrauchsanweisung User Manual Conseils d’utilisation KL 1500 HAL / KL 1500 H - Gebrauchsanweisung Gebrauchsanweisung KL 1500 HAL / KL 1500 H* Stand: März 2016 *abweichende Bezeichnung KL1500H möglich. In dieser Anweisung wird der Einfachheit halber nur von der KL 1500 HAL gesprochen. 1/15 KL 1500 HAL / KL 1500 H - Gebrauchsanweisung Inhalt 1. Wichtige Hinweise ............................................................................... 4 2. Betrieb ................................................................................................. 6 2.1 Lichtleiteranschluss ............................................................................. 6 2.2 Netzanschluss …………………………………………………………... 2.3 Inbetriebnahme .................................................................................. 7 2.4 Lichtstärkeeinstellung ......................................................................... 7 2.5 Anzeige und Einstellungen LCD-Display ………………………….…. 8 2.6 Zusatzoptik ………………………………………………………….…… 9 2.7 Filterschieber ...................................................................................... 10 3. Lampenwechsel .................................................................................. 11 4. Wartung .............................................................................................. 12 5. Beheben von Störungen ..................................................................... 12 6. Zubehör ............................................................................................... 13 7. Technische Daten ............................................................................... 14 6 2/15 KL 1500 HAL / KL 1500 H - Gebrauchsanweisung Geräteübersicht 2 5 8 7 12 4 6 1 3 9 11 13 10 (1) Hauptschalter 2.3 (2) Lichtleiteraufnahme mit Abschaltautomatik 2.1 (3) Feststellschraube 2.1 (4) Elektronische Lichtstärkeeinstellung 2.4 (5) LCD-Anzeige 2.5 (6) Schwenkhebel für Zusatzoptik 2.6 (7) Filterschieber 2.7 (8) Tragegriff 1. (9) Lampenfach mit Halogen-Kaltlicht-Reflektorlampe 3. (10) Netzkabel Anschlussbuchse 2.2 (11) Belüftungsöffnungen (Geräteboden) 1. (12) Abluftgitter (Geräterückseite) 1. (13) Typenschild (Geräteboden) 1. 3/15 KL 1500 H HAL / KL 1500 1 H - Gebrauchs G sanweisun ng 1. Wich htige Hinw weise Verwende ete Symbo ole: Sym mbol Bed deutung Warrnung vor ein ner Gefahren nstelle (Achtu ung, Dokume entation beaachten) Warrnung vor he eißer Oberflä äche Bestimmungsgemä äßer Gebrrauch: Die Kaltlich htquelle KL 1500 HAL ist für den E Einsatz in In ndustrie und d Labor vorrgesehen. Kaltlichtquellen diene en der inten nsiven Bele euchtung vo on Objekten aller Art. Die Infraro otanteile de er Lampenstrrahlung werden ausge efiltert. Sich htbares Lic cht hoher Intensität w wird durch flexible f ode er selbsttrage ende beweg gliche Lichtleiter zum O Objekt gefüh hrt. Gemäß de er Norm EN 62471:200 08 handelt e es sich bei der KL 150 00 HAL um ein Produk kt der Risiko oKlasse 1. quelle KL 15 500 HAL errfüllt die Bes stimmung foolgender Riichtlinien de er Die faseroptische Halogen-Lichtq hen Gemein nschaft: Europäisch 2014/35/EU (Niedersp pannungsric chtlinie) 2014/30/EU (EMV-Ricchtlinie) 2011/65/EU (RoHS) einstimmung g mit den grundlegen nden Anforrderungen obiger o Richhtlinien wird durch die Die Übere technische e Dokumenttation, sowie e die vollstä ändige Einh haltung folge ender Norm men nachge ewiesen: EN 61326--1:2013 EN 61010--1:2010 EN 50581::2012 UL 61010--1 Third Edition und CA AN/CSA-C2 22.2 No.611010-1-12 Sich herheitshiinweise: Bitte lese en und be eachten Sie e diese G Gebrauchsa anweisung sorgfältig g. Die Sich herheit de es Gerätes is st bei Nichttbeachtung g nicht gew währleistet.. Während des Betrie ebs niemals direkt in n die Lichttaustrittsöfffnung der Lichtquelle oder de es Lichtleiterrs blicken (Gefahr ( von Augenve erletzungen n)! Von der KL L 1500 HAL L geht sichttbares Lichtt hoher Inte ensität aus. Da lichtabssorbierende e Materialie en die physikkalische Eig genschaft haben, h aufftreffendes Licht in Wärme W umzzuwandeln, können an a wärmeemp pfindlichen oder entzü ündbaren licchtabsorbie erenden Ma aterialien Scchädigunge en auftreten n. Zur Verme eidung solccher thermiischer Schä äden und möglicher Brand- bzw w. Verbrennungsgefah hr beachten S Sie bitte folg gende Hinw weise: 4/15 KL 1500 H HAL / KL 1500 1 H - Gebrauchs G sanweisun ng Decken Sie den Licchtleiteraus sgang nie ab b (Brandgeffahr)! Bedeckken Sie den d Lichtle eiterausgan ng nie miit der Ha and oder anderen Körperteile en (Verbrennungsgefa ahr)! Bei der Beleuchtun ng wärmeem mpfindliche r oder entzü ündbarer lic chtabsorbieerender Obje ekte (z. B. in der Mikkroskopie) isst besonderrs darauf zu u achten, Lichtleiterab L bstand und Lampenhellligkeit so zu z wählen,, dass am Objekt O keine e thermische en Schädig gungen auftrreten. Alle niccht im Arbeitsvorgang verwendete en Lichtleite erausgänge e müssen ssich bei eingeschaltete er Lichtque elle stets in n einem sic cheren Absttand -minde estens 10 cmc von wäärmeempfindlichen ode er entzünd dbaren lichttabsorbiere enden Mate erialien befiinden (Verm meidung m möglicher Brandgefahr B r). Achten Sie daher bei jenen Lichtleite erausgänge en auf obigen sicherren Abstan nd von z.B B. dunklen n/farbigen Textilien T und d dunklen/fa arbigen Holz z- oder Kun nststoffoberf rflächen Um eine e unnötige Belastung biologische en Gewebes durch Beleuchtung m mit sichtbarrem Licht zu z vermeid den, reduzie eren Sie die e Helligkeit und Dauerr der Beleuchtung biollogischen Gewebes G au uf das unb bedingt erfo orderliche Maß. M Achten Sie beim Anschluss A de es Gerätes auf eine sic chere Schutzleiterverb indung. Bitte achten Sie un nbedingt darauf, d da ss Ihre Kaltlichtque elle KL 150 00 HAL mit der auf dem Typensc child (13) anngegebenen Spannung betrie eben wird; unbe edingt alle Lüftungsöffn L nungen (11 , 12) freige ehalten werrden. Bei u nzureichender Kühlung scha altet ein inte egrierter Thermoschaltter das Gerrät vorüberg gehend auss (s. Punkt 5 „Behebe en von S Störungen“)); die L Lampe vorr dem Austtauschen a abgekühlt ist. Zu Ihre er Erinneru ng ist in der d Tür de es Lamp penfachs eiin Warnzeic chen angeb bracht: (W Warnung vo or heißer Ob berfläche); Filterrschieber un nd Einlegeffilter vor derr Entnahme e des Einleg gefilters abggekühlt sind. Der Schie eber ist mit dem Warnz zeichen versehen; sich der Filterscchieber beim m Betrieb de er Lichtquellle grundsättzlich in eineer Raststellung ndet (s. Pun nkt 2.6 „Filte erschieber“))! befin der L Lichtleiter vo or dem Aus stausch abg gekühlt ist. nen Räume en entwickeelt worden (s. Punkt 7 Die Lichtquelle istt nur für den Betrieb in trocken „Technische Daten n“). explosionsg gefährdeten Bereichen geeignet. Dieses Gerät ist niccht für den Betrieb in e nung vom Stromversorg gungsnetz erfolgt nur durch d Zieheen des Netz zsteckers. Eine sicchere Trenn Das Ge erät darf nich ht geöffnet oder demon en. Technische Änderuungen am Gerät G sind zu z ntiert werde unterlasssen. Reparaturen dürfen d nurr durch den Herste eller oder von ihm autorisiertte Kunden ndienststelle en durchgefführt werden n. Bitte g gewährleiste en Sie jed dem Bedie ener des Gerätes den d rasch en Zugriff auf diesse Gebrauchsanweisu ung. Für Schäden, die e durch Nic chtbeachtun ng dieser Gebrauchsanweisung entstehen, haftet de er Hersteller nicht. 5/15 KL 1500 H HAL / KL 1500 1 H - Gebrauchs G sanweisun ng 2. Betrieb 2.1 Lichttleiteransc chluss Zunächst d die Festste ellschraube (3) der Licchtleiteraufn nahme (2) öffnen, durrch Drehen n gegen de en Uhrzeigerssinn. Den Lichtleiter L biis zum Ansschlag einsc chieben und d Feststellsschraube du urch Drehe en im Uhrzeig gersinn schließen. Beim Einssetzen von Lichtleitern n mit Führu ungsstift ist zusätzlich darauf zu achten, da ass dieser in einer der b beiden Führrungsschlitz ze eingepassst wird. Sich herheitshiinweis: ACHTUNG G! Lichtleiter können bei längerem Betrieb B heiß ß werden Bitte achten Sie darauf, dass der Lichtleiter L vo or dem Austa auschen ab bgekühlt ist.. Es wird e mpfohlen die d Lichtque elle vor dem m Lichtleiterwechsel fü ür ca. 5 Min a auszuschaltten. Zu Ihre er Erinnerun ng ist das Warnzeichen W n angebbracht. eiteraufnahm me (2) ist zusätzlich mit einer Sensorik (A Abschaltauttomatik) ve ersehen, die Die Lichtle einen Bettrieb der Lampe L nur gestattet, wenn sich h ein emp pfohlener LLichtleiter in n der dafü ür enen Öffnu ung befinde et. Eine B Blendung beim Betriieb ohne Lichtleiter, z.B. beim m vorgesehe versehentlichen We echseln de es Lichtleitters ohne die Lich htquelle aam Haupts schalter (1 1) auszuscha alten, wird dadurch d vermieden. Solange siich im einge eschalteten n Zustand d der Lichtque elle kein Lic chtleiter in dder Lichtleitteraufnahme (2) befinde et, erscheintt in der LCD D-Anzeige ( 5) die Fehle ermeldung „No Light G Guide“. 2.2 Netza anschluss s: VV-F3G0,75 (als Das dreipolige Netzkabel vom Typ H05V erhältlich) in die d dafürr vorgesehene Zubehör buchse (10) an derr Geräterü ckseite ste Anschlussb ecken. Dieses wirrd an das Stromnetz (100-240 V AC, 50-6 60 Hz) angeschlosssen. Bitte achte en Sie unbe edingt dara auf, dass Ih hre Kaltlichttquelle KL 1500 HAL nur im angeg gebenen S pannungsb bereich betrieben w wird. Bei Austau usch des Netzkabels N etzkabel gle eichen ist ein Ne Typs zu ve erwenden. 6/15 KL 1500 HAL / KL 1500 H - Gebrauchsanweisung 2.3 Inbetriebnahme Ein-/Ausschalten der KL 1500 HAL durch Betätigung des Hauptschalters (1). Bei eingeschaltetem Gerät leuchtet die Anzeige im LCD-Display (5). Stellung O: Das Gerät ist ausgeschaltet. Zur Trennung der Stromversorgung, bitte Netzstecker ziehen! Die KL 1500 HAL ist zur Schonung der Halogenlampe mit einem Softanlauf ausgerüstet, der den sonst üblichen hohen Einschaltstrom reduziert. 2.4 Lichtstärkeeinstellung Durch Drehen des Lichtstärkereglers (4) kann die Helligkeit kontinuierlich eingestellt werden. Die eingestellte Helligkeit wird im LCD-Display (5) in 1%-Schritten von 0-100% angezeigt. Durch einmaliges Drücken des Lichtstärkereglers (4) kann diese auch in einer äquivalent hinterlegten Farbtemperatur [Kelvin] am Lichtleiterausgang angezeigt werden. Bitte beachten Sie, dass es sich hierbei nicht um eine exakte physikalische Größe handelt und einer gewissen Ungenauigkeit unterliegt! Sie dient lediglich als Richtgröße! Schwankungen durch Fertigungstoleranzen der Lampe und Alterungsprozesse werden nicht berücksichtigt! Die höchste Lichtintensität wird in Position 100% (3400K) erreicht. Die mittlere Lebensdauer der Lampe beträgt dabei etwa 50 h (Angabe des Lampenherstellers). Der Regelbereich der KL 1500 HAL ist in 3 unterschiedliche Segmente eingeteilt und wird im LCDDisplay (5) entsprechend angezeigt. Die Bereiche können als Indikator für die anwendungsabhängige Helligkeit und somit für die Lampenlebensdauer genutzt werden: ECO 0 - 49% > 1500 h STANDARD 50 - 79% ca. 150 – ca. 1500 h BOOST 80 - 100% ca. 50 – ca. 150 h 7/15 KL 1500 HAL / KL 1500 H - Gebrauchsanweisung Bei der Reglerstellung 0% ist keine Intensität mehr vorhanden, d.h. die Lampe ist aus. Achtung: Es ist zu beachten, dass in Reglerstellung 0% das Gerät nicht ausgeschaltet ist. Zum Ausschalten der KL 1500 HAL ist der Hauptschalter (1) zu betätigen (s. Punkt 2.3 „Inbetriebnahme). Zur sicheren Trennung der Stromversorgung, bitte Netzstecker ziehen! Die gesamte Betriebsdauer der Lampe (unabhängig von der eingestellten Intensität) kann bei Bedarf auf dem LCD-Display angezeigt werden (s. Punkt 2.5 „Anzeige und Einstellungen LCDDisplay). 2.5 Anzeige und Einstellungen LCD-Display Anzeige Helligkeit Die am Lichtstärkeregler (4) eingestellte Helligkeit kann entweder in Prozent oder Kelvin angezeigt werden (siehe Pkt. 2.4). Die Umstellung erfolgt jeweils durch einmaliges kurzes Drücken des Lichtstärkereglers (4). Anzeige Betriebsdauer der Lampe Bei Bedarf kann die kumulierte Gesamtbetriebsdauer der eingesetzten Halogenlampe im LCDDisplay (5) angezeigt werden. Diese wird im Laufe der Lebenszeit in volle Stunden [h] aufaddiert, unabhängig mit welcher Spannung die Lampe betrieben wird. Durch die Menüsteuerung kann die Anzeige ein- bzw. ausgeschaltet werden. Um in die Menüsteuerung zu gelangen, halten Sie den Lichtstärkeregler (4) > 5 Sekunden gedrückt. Sobald sich die Lichtquelle in der Menüsteuerung befindet, schaltet die Lampe ab. Durch Drehen des Lichtstärkereglers (4) nach rechts und links bewegt sich der Anzeigepfeil in die entsprechenden Menüfelder. Das jeweilige aktive Menüfeld wird invers angezeigt. Durch einmaliges kurzes Drücken des Lichtstärkereglers (4) gelangt man in das ausgewählte Untermenü. 8/15 KL 1500 HAL / KL 1500 H - Gebrauchsanweisung Zum Einschalten der Betriebsstundenanzeige wählen Sie bitte das Untermenü „On/Off“ aus. Durch Drehen des Lichtstärkereglers (4) wählen Sie „On“ und bestätigen es durch kurzes Drücken (Haken erscheint im Menüfeld). Wählen Sie „Menü“ und danach „Exit“. Die Lampe schaltet sich wieder ein. Die Betriebsstunden werden im LCD-Display (5) links oben angezeigt. Zum Ausschalten der Betriebsstundenanzeige wählen Sie bitte das Untermenü „On/Off“ aus. Durch Drehen des Lichtstärkereglers (4) wählen Sie „Off“ und bestätigen es durch kurzes Drücken (Haken erscheint im Menüfeld). Wählen Sie „Menü“ und danach „Exit“. Wird die Betriebsstundenanzeige der Lampe verwendet, sollte nach einem Lampenwechsel die Betriebsstundendauer wieder auf 0h gesetzt werden. Dies geschieht nicht automatisch! Drücken Sie dazu den Lichtstärkeregler (4) > 5 Sekunden, um in die Menüsteuerung zu gelangen. Wählen Sie bitte das Untermenü „Reset“ aus. Durch Drehen des Lichtstärkereglers (4) wählen Sie „Reset“ und bestätigen es durch kurzes Drücken (Haken erscheint im Menüfeld). Wählen Sie „Menü“ und danach „Exit“. Die Betriebsstunden der Lampe werden nun im Speicher wieder neu (bei 0h beginnend) aufaddiert, unabhängig davon, ob die Betriebsstundenanzeige ein- oder ausgeschaltet ist. 2.6 Zusatzoptik Das Einschwenken der Zusatzoptik gewährleistet, dass auch bei Verwendung von Lichtleitern geringeren Bündeldurchmessers als 9 mm eine gleichmäßige, lichtstarke Ausleuchtung erreicht wird. Wird die Beleuchtung mit abbildenden oder fokussierenden optischen Systemen am Lichtleiterausgang durchgeführt, so erhält man eine optimal gleichmäßige Ausleuchtung durch Ausschwenken der Zusatzoptik. Zum Ein- und Ausschwenken der Zusatzoptik drehen Sie den Schwenkhebel (6) nach links bzw. rechts auf die entsprechenden Symbole. Die Zusatzoptik muss immer bis zum Endanschlag einbzw. ausgeschwenkt werden! 9/15 KL 1500 H HAL / KL 1500 1 H - Gebrauchs G sanweisun ng schieber 2.7 Filters 500 HAL ve erfügt über einen Filte erschieber (7), ( der mitt einem Einnlegefilter (als ( Zubehö ör Die KL 15 erhältlich) bestückt we erden kann. m sich beim Betrie eb der Lic chtquelle grundsätzlichh in einer der beide en Der Filtersschieber muss Endpositio onen oder de er Raststellung befinde en. Sich herheitshiinweis: ACHTUNG G! Das Betreiiben der Licchtquelle in einer Zwiscchenstellun ng des Filterrschiebers kkann zur Be eschädigung desselben führen. ng des Filterschieberrs Bestückun herheitshiinweis: Sich ACHTUNG G! Bitte achte en Sie darrauf, dass der Filters chieber (7)) vor der Bestückung B g mit dem Einlegefilte er abgekühlt ist. Zu Ihrerr Erinnerung g ist das Wa arnzeichen angebrracht. h en und so drehen, dass s die Beschhriftung lesb bar ist (links). Den Filtersschieber (7)) komplett herausziehe Den Einleg gefilter mit 28 2 mm Durrchmesser m mit Hilfe vo on fusselfreien Handscchuhen von oben rechtts hinter die b beiden Halttenasen einführen und durch leich hten Druck oben rechtss fest einklicken (mitte). Der Filter liegt nun pla an in der in der Halteru ung (rechts). H (links) leich nks biegen und den F Filter mit Handschuhe en Zur Entnahme den Haltebügel ht nach lin n. entnehmen Möchten S Sie die Lichttquelle kurz zzeitig ohne Filter betre eiben, so zie ehen sie deen Schieberr nur bis zum m 1. Rastpun nkt heraus. Der Filter befindet b sic h in dieser Position no och in der LLichtquelle, jedoch nich ht mehr im Sttrahlengang g. 10/15 1 KL 1500 H HAL / KL 1500 1 H - Gebrauchs G sanweisun ng enwechsell 3. Lampe Sich herheitshiinweis: ACHTUNG G! Bitte achte en Sie darau uf, dass Lampe und La ampenfassu ung vor dem m Austauscchen abgekühlt sind. Zu Z Ihrer Erinnerung ist da as entsprec chende Warrnzeichen angebrac cht. en Sie darau uf die Lichtq quelle auszu uschalten und u den Nettzstecker zuu ziehen. Bitte achte Bitte achte en Sie dara auf, nicht in n das Gerä ät zu fasse en. Es bestteht Verletzzungsgefahr durch de en nachlaufen nden Lüfter.. Lampenfacch (9) durch h Herunterd drücken und d Ziehen an n der vorges sehenen Veertiefung öfffnen und biis zum Anschlag hera ausziehen. Lampe, inklusive Sockel, nach n obenn aus derr Halterung herausneh hmen. Die defekte La ampe vorssichtig vom m Sockel abziehen a uund eine neue n Lamp pe aufstecken n (bitte Lam mpe verwend den, wie un nter Pkt. 6.4 4 spezifiziert). Danachh die Lampe e wieder vo on oben bis zzum Anschla ag in die Ha alterung drü ücken. Das s Lampenfac ch bis zur A Arretierung einschiebe en (hörbares Einrasten). Den Netzsttecker einsttecken und die Lichtqu uelle einschaalten. Austausch des Lampe ensockels: nsdauer des s hochwertig gen Lampensockels Die garantierte Leben bsstunden oder o alterna ativ 20 beträgt 20..000 Betrieb Lampenwe echsel. Zum Austa ausch des Lampensock L kels zunäch hst die Lampe vorsichtig a abziehen, wie w oben be eschrieben. Mit einem Schrauben ndreher die beiden obe eren Befestiigungsschra auben der Klemme lö ösen und da as komplette e Bauteil en ntfernen. Die beiden Kabelende en des neue en Sockels (Ersatzteil ssiehe Pkt. 6.4) 6 in die entspreche enden Öffnu ungen der Klemme K ste ecken und Schrauben n wieder anzziehen (auff festen Sitzz achten). La ampe wieder auffstecken und d in die Halterung drüccken, wie ob ben beschriebe en. 11/15 1 KL 1500 HAL / KL 1500 H - Gebrauchsanweisung 4. Wartung Ihre KL 1500 HAL ist wartungsfrei. Eine Desinfektion der Lichtquelle bei Anwendung im medizinischen Bereich ist nicht vorgesehen. Zur äußerlichen Reinigung des Gerätes verwenden Sie ein weiches trockenes Tuch oder handelsübliche Kunststoff-Reinigungstücher. 5. Beheben von Störungen Sollten Sie die Störung durch die nachfolgend genannten Maßnahmen nicht beheben können, wenden Sie sich bitte an Ihren Fachhändler oder die nächste SCHOTT-Vertretung. Weitergehende Reparaturen müssen vom autorisierten Kundendienst durchgeführt werden. Fehler und Störungen werden in der Regel im LCD-Display (5) angezeigt (siehe Pkt. 2.5): Overheating: Kühlung nicht ausreichend; Temperaturwächter hat angesprochen Open Circuit: Lampenstromkreis unterbrochen; Lampe defekt bzw. keine Lampe No Fan: Lüfter defekt No Light Guide: kein Lichtleiter in der Lichtleiteraufnahme (2) Art der Störung Mögliche Ursache Behebung Lampe aus, Lüfter aus, keine Display-Anzeige Gerät nicht eingeschaltet Gerät einschalten Stecker nicht in Steckdose Stecker einstecken Keine Netzspannung Netzspannung prüfen Lampenfach nicht geschlossen Lampe defekt Lampenfach schließen Lampe austauschen (s. Punkt 3 dieser Gebrauchsanweisung) Keine Lampe Bei ausgeschalteter Lichtquelle Lampe einsetzen Lampe kein Kontakt Lampe in Fassung drücken Lampe aus, Lüfter in Betrieb, Fehlerstatusanzeige „Open Circuit“ 12/15 KL 1500 HAL / KL 1500 H - Gebrauchsanweisung Lampe aus, Lüfter in Betrieb, Fehlerstatusanzeige „Overheating“ Elektronik überhitzt Ausreichende Kühlung sicherstellen, auf richtigen Lampentyp prüfen, Gerät nach längerer Abkühlung wieder in Betrieb nehmen Lampe aus, Lüfter aus, Lüfter defekt, Rotor blockiert Fehlerstatusanzeige „No Fan“ Von autorisiertem Kundendienst reparieren lassen Lampe aus, Lüfter in Betrieb, Kein passender Lichtleiter in Fehlerstatusanzeige „No Light der Lichtleiteraufnahme. Guide“ Passenden Lichtleiter in die Lichtleiteraufnahme stecken, auf korrekten Sitz prüfen Lichtleiter nicht bis zum Anschlag eingesteckt Lichtleiter bis zum Anschlag in Lichtleiteraufnahme stecken 6. Zubehör zur KL 1500 HAL Für Ihre KL 1500 HAL ist ein breites Zubehörprogramm lieferbar. Ein separater Prospekt informiert Sie ausführlich (Adresse zur Anforderungsmöglichkeit siehe S. 15) Nur SCHOTT-Lichtleiter und -zubehör gewährleisten einwandfreie Funktion, Sicherheit und optimale Lichtausbeute. 6.1 Lichtleiter Es stehen selbsttragende und flexible Lichtleiter verschiedener Längen und Durchmesser sowie Punkt- und Spaltbeleuchtungen zur Verfügung. 6.2 Halogenlampe Bei Bestellung von Halogenlampen als Ersatzteil (siehe Punkt 6.4 dieser Gebrauchsanweisung) wird der Lampentyp geliefert, der optimale Lichtausbeute und Ausleuchtung ermöglicht. 6.3 Filter Optische Filter können entweder in den Filterschieber (7) eingelegt oder als Einschraub- bzw. Aufsteckfilter in Verbindung mit einem Fokussiervorsatz (Zubehör) vor den Lichtleiterausgang gesetzt werden. Details zum Fokussiervorsatz und zu den standardmäßig erhältlichen Filtertypen entnehmen Sie bitte dem Zubehörprospekt. 13/15 KL 1500 HAL / KL 1500 H - Gebrauchsanweisung 6.4 Ersatzteile Halogenlampe 15 V / 150 W Philips, Typ 6423 Philips, Typ 6423 XHP Osram, Typ HLX 64634 (Best. Nr. 153000) Lampensockel (Best. Nr. 150710) Nur bei Verwendung der angegebenen Ersatzteiltypen wird für einwandfreie Funktion, Sicherheit und optimale Lichtausbeute Gewährleistung übernommen. 7. Technische Daten KL 1500 HAL Eigenschaften Werte Allgemeine Angaben Typenbezeichnung - KL 1500 HAL Maße (B x T x H) mm ca. 202 x 146 x 286 Masse kg ca. 4,2 Kühlung - Axiallüfter Umgebungstemperatur °C + 5 ... + 40 Relative Luftfeuchte % bis 31°C Umgebungstemperatur: 85% 31°C bis 40°C Umgebungstemperatur: linear abnehmend auf 75% Luftdruck hPa 800 ... 1060 Transport und Lagerung Temperatur Rel. Luftfeuchte Luftdruck °C % hPa -20 ... +70 10 ... 95 (nicht kondensierend) 500 ... 1200 Elektrische Angaben Betriebsspannung, Frequenz 100 - 240 V ~ 50 - 60 Hz Leistungsaufnahme max. VA max. 180 Schutzklasse - I II Überspannungskategorie Lampenart - Halogenreflektorlampe Philips, Typ 6423 Philips, Typ 6423 XHP Osram, Typ HLX 64634 Lampennennspannung V 15 Lampennennleistung W 150 Mittlere Lampenlebensdauer Stufe 50% Stufe 80% Stufe 100% h h h 1500 150 50 14/15 KL 1500 H HAL / KL 1500 1 H - Gebrauchs G sanweisun ng Lichttechn nische Anga aben Maximal licchttechnisch nutzbarer Bündeldurcchmesser de es Lichtleiters s mm m 9 Gesamtlich htstrom am Lichtleiteraus L sgang (SCHOTT--Lichtleiter Ø 9 mm, typ. Werte) W Stufe 50% Stufe 80% Stufe 100% % lm m lm m lm m 0 ca. 250 ca. 450 0 ca. 600 0 Lichtaustritttswinkel (2 eff ) ca. 85° Wärmeschutzfilter - Kennzeiche en - Prüfzeichen - EMV-Emissionsklasse - SCHOT TT KG 2, 45 x 45 d = 2,0 mm, gehärte et B Änderunge en in Ausfüh hrung und Lieferumfan L ng im Rahm men der tech hnischen Weeiterentwick klung vorbehalte en. WEEE Erklärung Ihr SCH HOTT Produkt wurde w mit hochw wertigen Materialien und Kompo onenten entwick kelt und hergesttellt. Das Symbo ol bedeutet, dass elektrische und elektronische e Ge eräte am Ende ihrer ngsdauer vom Hausmüll H getren nnt entsorgt werrden Nutzun müssen. TT AG Lighting and Imaging ha at für die Entsorrgung ein SCHOT Rückna ahmesystem ein ngerichtet. Bitte e verwenden Sie e für die Entsorg gung dieses System. Helfen Siie mit die Umwe elt, in der wir leben zu z erhalten. Weitere e Informationen n zum Rücknahm mesystem finde en Sie unter www.schott.com/lightin ngimaging/recyccle. Herstelleradresse: SCHOTT AG Geschäftssbereich Liighting and d Imaging Otto-Scho ott-Strasse e2 55127 Ma ainz Tel. 06131 / 66 - 0 15/15 1 KL 1500 HAL / KL 1500 H - Operating instructions Operating instructions KL 1500 HAL / KL 1500 H* Status: March 2016 *different name KL1500H possible. In this operating instructions for the sake of simplicity, only the KL 1500 HAL is mentioned in the text. 1/15 KL 1500 HAL / KL 1500 H - Operating instructions Contents 1. Important information ............................................................................... 4 2. Operation ................................................................................................. 6 2.1 Light guide connection ............................................................................. 6 2.2 Power connection …………………………………………………………... 6 2.3 Start up procedure .................................................................................. 7 2.4 Light intensity setting ................................................................................. 7 2.5 LCD display indication and settings …………………..……………….…. 8 2.6 Supplementary optics ……………………………………………………….…… 9 2.7 Filter slide .............................................................................................. 10 3. Lamp change ......................................................................................... 11 4. Maintenance .............................................................................................. 12 5. Troubleshooting ..................................................................................... 12 6. Accessories ............................................................................................... 13 7. Technical data ............................................................................................. 14 2/15 KL 1500 HAL / KL 1500 H - Operating instructions The instrument at a glance 2 5 8 7 12 4 6 1 3 9 11 13 10 (1) On/off switch 2.3 (2) Light guide socket with automatic shut off 2.1 (3) Locking screw 2.1 (4) Electronic light intensity setting 2.4 (5) LCD display 2.5 (6) Pivot lever for supplementary optics 2.6 (7) Filter slide 2.7 (8) Carrying handle 1. (9) Lamp compartment with halogen cold light reflector lamp 3. (10) Mains connection socket 2.2 (11) Air vents (base of instrument) 1. (12) Ventilation grid (back of instrument) 1. (13) Model plate (base of instrument) 1. 3/15 KL 1500 H HAL / KL 1500 1 H - Operating O instructio ons 1. Impo ortant infformation n Symbols used: Sym mbol Mea aning Warrning of dang ger (caution, obey docum mentation) Warrning of hot surface s Intended use: The KL 1500 HAL cold light sourrce is intend ded for industrial and la aboratory appplications. e used for th he intensive e illuminatio on of all type es of objectts. The infra ared portion ns Cold light ssources are of the lamp p's radiation n are filtered d out. High intensity vis sible light is s guided to tthe object using u flexible or self supporting, mo ovable light guides. 6 he KL 1500 0 HAL is a product p of R Risk Class 1. standard th According to the EN 62471:2008 500 HAL fibre optic light source conforms to the prov visions of tthe followin ng Europea an The KL 15 directives: 2014/35/EU (Low Volttage Directiive) 2014/30/EU (EMC Dirrective) 2011/65/EU (RoHS) nical docum mentation and a full co mpliance with w the sta andards lissted below proves the The techn conformity with the esssential requ uirements o of the follow wing EC Dire ectives: EN 61326--1:2013 EN 61010--1:2010 EN 50581::2012 UL 61010--1 Third Edition und CA AN/CSA-C2 22.2 No.611010-1-12 Safe ety inform mation: Please read and ob bserve the ese instruc ctions care efully. The instrumen b nts safety cannot be guarantee ed unless you y observ ve the opera ating instru uctions. Never look directly into the op pen light g guide socket or the liight guide exit during operation mic injury!) (danger off ophthalm 500 HAL em mits high intensity visib ble light. As s light abso orbing mateerials have the physica al The KL 15 property of converting g incident light l into he eat, damag ge may occ cur to heat sensitive or o flammable light absorrbing materials. To av void such th hermal damage and the e potential danger of fire f or burnss, please adh here to the following f ins structions: 4/15 KL 1500 H HAL / KL 1500 1 H - Operating O instructio ons Never ccover up the e light guide e exit (dange er of fire!) Never ccover up th he open of the light g guide exit with w your hands or othher parts of o your bod dy (dangerr of burns!) When iilluminating heat sens sitive or fla ammable lig ght absorbing objectss (e.g. in microscopy m y), special care must be taken to o keep an a appropriate distance between thee light guide e and objecct. Also to select a suiitable lamp brightness level in ord der to avoid thermal da mage to the e object. ource is sw witched on,, all light guide g exists s not beingg used in the working When tthe light so procedu ure must always be a safe dista ance – at least 10 cm m – away from heat sensitive or o flammable light absorbing ma aterials (pre evention of possible fire e hazard). C Care must therefore be b taken th hat each lig ght guide exit e is at th he above mentioned m safe s distannce away, for f example e: dark/coloured textiles and darrk/coloured wooden or plastic surfaces. To avoiid unnecesssary strain on biologiical tissue by illumina ating with vvisible light, reduce the brightne ess and durration of illumination to the absolute minimum m level requ ired. Ensure a safe earthing connection when connecting g the device Please m make sure that t your KL 1500 HAL cold ligh ht source is operated at a the voltag ge stated onn the model plate (13); all a air vents (11, 12) are kept clea r at all tim mes. In the event of insufficient cooling, an a integ grated therm mo switch will w cut off the e instrumen nt temporarily (see Poi nt 5 "Troubleshooting"") the la amp has co ooled off be efore being replaced. A warning sign s has beeen attached d in the doo or of the e lamp com mpartment to o remind yo ou of this ne ecessity: (w warning of hot h surface)) the fiilter slide an nd insert filtter have coo oled off befo ore the inse ert filter is reemoved. Th he slide is markked with a warning w sign n the fiilter slide is always locked in place e during the e operation of the light source (see e Point 2.6 "Filte er slide"!) the liight guide iss cooled offf before bein ng replaced d. The ligh ht source has h been de eveloped fo or operation n in dry roo oms only! ((see Point 7 "Technica al data"). ust not be us sed in explo osive areas. The insttrument mu Safe dissconnection n from the power p supplly is only gu uaranteed by b pulling ouut the mains s plug. The insstrument ma ay neither be opened nor dismantled. Tech hnical modiffications arre forbidden n. Repairss must onlyy be carried d out by th he manufac cturer or by y its authorrised custo omer servicce agencie es. Please ensure thatt every userr of the systtem has quiick access to t these opeerating instructions. The ma anufacturer is not liable e for damage e caused by failure to obey these instructions s. 5/15 KL 1500 H HAL / KL 1500 1 H - Operating O instructio ons 2. Operration 2.1 Lightt guide co onnection Start by lo oosening the locking screw s (3) o of the light guide g socket (2) by tuurning it an nti-clockwise e. Insert the light guide as a far as it will w go and ttighten the locking scre ew by turninng it clockw wise. Attention: W When inserrting light gu uides with a locating pin, p care mu ust be takenn to ensure e that the pin fits into one e of the two o guide slots s. Safe ety inform mation: ATTENTIO ON! Light guide es can beco ome hot during prolong ged use. Please make e sure that tthe light guiide is coole ed down befo ore replacing g it. It is recommende ed to turn offf the light source s for aabout 5 min nutes beforre replacing the light guid de. A warning sign hass been attac ched to remind youu of this nec cessity. guide socke et (2) is equipped in ad ddition with a sensor sy ystem (autoomatic switc ch off) whicch The light g prevents th he operatio on of the lam mp unless a recomme ended light guide is seeated in the e designate ed opening. T This protectts the user from being g blinded du uring operation withoutt light guide e, e.g. whe en the light gu uide is exch hanged by mistake m befo ore the lightt source is turned t off aat the on/off switch (1). If the light guide is rem moved from m the light g uide sockett (2) during operation, the lamp will w switch offf. It will turn b back on as soon as the e light guide e is reinsertted into the light guide socket (2). This will no ot affect the b brightness level set at the t light inte ensity settin ng (4). As long ass there is no o light guide e in the ligh ht guide soc cket (2) whe en the lightt source is switched s on n, the LCD diisplay (5) will w show the e error messsage "No Light L Guide"". 2.2 Powe er connection: Insert the three pin power corrd of type H05VV-F3G0,75 accessory) into i the des signated pl ug in socke et (10) (optional a on the bacck of the in nstrument. The T instrum ment needs to be connected to the main ns supply (1 100-240 V A AC, 50-60 Hz). H ou operate your y KL 150 00 HAL cold d light Please enssure that yo source only within the e specified voltage v rang ge. When repla acing the po ower cord the same tyype must be e used. 6/15 KL 1500 HAL / KL 1500 H - Operating instructions 2.3 Start up procedure Switch on/off the KL 1500 HAL by pressing the on/off switch (1). The indicator on the LCD display (5) is lit when the instrument is switched on. Position O: The instrument is switched off. Please disconnect the power by pulling out the power plug! To protect the halogen lamp the KL 1500 HAL is fitted with a gentle start up device that reduces the high switch on current that would otherwise occur. 2.4 Light intensity setting The brightness can be adjusted continuously by turning the light intensity setting rotary dial (4). The set brightness is indicated on the LCD display (5) in 1% increments between 0 and 100%. You can have the light intensity displayed as the equivalent colour temperature [Kelvin] at the light guide exit by means of a single press on the brightness control (4). Please note that this indicator is not an exact physical quantity and therefore, subject to a certain level of inaccuracy! It is merely intended as an approximate value! Neither fluctuations caused by manufacturing tolerances of the lamp nor any ageing processes are taken into account! The greatest light intensity is reached when the rotary dial is turned all the way to the 100% position (3400K). The average lifetime of the lamp is approximately 50 h (as specified by the manufacturer of the lamp). The brightness of the KL 1500 HAL can be regulated across 3 different segments and is indicated accordingly on the LCD display (5). These ranges can be used as an indicator for the application specific brightness and thus for the lifetime of the lamp: ECO 0 - 49% > 1,500 h STANDARD 50 - 79% approx. 150 h – approx. 1,500 h BOOST 80 - 100% approx. 50 h – approx. 150 h 7/15 KL 1500 HAL / KL 1500 H - Operating instructions When the brightness control is set to 0% there is no more light intensity, i.e. the lamp is off. Attention: Please note that when the brightness control is set to 0%, the instrument is not switched off. You switch off the KL 1500 HAL by pressing the on/off switch (1) (see Point 2.3 "Start up procedure"). Please ensure safe power disconnection by pulling out the power plug! If necessary, you can have the total operating time of the lamp (varying with the set intensity) displayed on the LCD display (see Point 2.5 "LCD display indication and settings"). 2.5 LCD display indication and settings Brightness indicator The brightness set at the light intensity setting rotary dial (4) can be displayed either in per cent or Kelvin (see Point 2.4). You can toggle the display by briefly pressing the light intensity setting rotary dial (4) once. Indicator of lamp operating time You can have the LCD display (5) indicate the accumulated total operating time of the used halogen lamp. This time is added up in full hours [h] throughout the lifetime of the lamp depending on which type of voltage is used with the lamp. You can use the menu control to switch this indicator on or off. To access the menu control, press and hold the light intensity setting rotary dial (4) > 5 seconds. The lamp will switch off as soon as the light source is set to menu control. Turning the light intensity setting rotary dial (4) clockwise and anti-clockwise will move the indicator arrow to the corresponding menu fields. The currently selected menu field is displayed as an inverted field. Press the light intensity setting rotary dial (4) briefly once to open the selected submenu. 8/15 KL 1500 HAL / KL 1500 H - Operating instructions Select the submenu "On/Off" to enable the operating hour counter. Turn the light intensity setting rotary dial (4) to select "On" and confirm your selection with a brief press of the rotary dial (a checkmark will appear in the menu field). Select "Menu" followed by "Exit". The lamp will switch back on. The operating hours are indicated at the top left of the LCD display (5). To turn off the operating hour indicator, select "On/Off" in the submenu. Turn the light intensity setting rotary dial (4) to select "Off" and confirm your selection with a brief press of the rotary dial (a checkmark will appear in the menu field). Select "Menu" followed by "Exit". If using the operating hour indicator of the lamp, you should reset the operating hour counter to 0 h after changing the lamp. This will not happen automatically! Press and hold the light intensity setting rotary dial (4) > 5 seconds to access the menu control. Next, select the "Reset" submenu. Turn the light intensity setting rotary dial (4) to select "Reset" and confirm your selection with a brief press of the rotary dial (a checkmark will appear in the menu field). Select "Menu" followed by "Exit". The counting of the lamp's operating hours in the memory will start anew (beginning with 0h) regardless of whether the operating hour indicator is turned or turned off. 2.6 Supplementary optics The use of the supplementary optics ensures that you will achieve uniform, high intensity illumination even when using light guides with a smaller bundle diameter than 9 mm. If the illumination is carried out with imaging or focussing optical systems at the light guide exit, perfectly uniform illumination is achieved by moving the supplementary optics out of the optical path. To pivot the supplementary optics in and out, turn the pivot lever (6) clockwise or anti-clockwise to the corresponding symbols. The supplementary optics always need to be pivot in or out as far as they will go! 9/15 KL 1500 H HAL / KL 1500 1 H - Operating O instructio ons 2.7 Filter slide h a filterr slide (7) which can be fitted with w an inssert filter (available as a The KL 1500 HAL has accessory)). When operating the light source,, the filter sllide must always be en ngaged in oone of the end e position ns or in the re est position. Safe ety inform mation: ATTENTIO ON! Operating the light so ource with the t filter slid de in an inttermediate position cann cause da amage to the slide. Fitting th he filter slide s Safe ety inform mation: ATTENTIO ON! Please enssure the filtter slide (7) has cooled d down before fitting th he insert filtter. A warning sign ha as been attacched to remind r you of this nece essity. he filter slide e (7) from th he light sou urce so that the label iss legible (lefft). Insert th he Completelyy pull out th filter with 2 28 mm diam meter using lint-free glo oves from to op right beh hind the twoo retaining lu ugs and fix it with slight pressure (ccenter). The e filter is the en lying flat inside the holder h (rightt). e easily bend the brack ket (left) to tthe left and remove the e filter with ggloves. To remove If you wish h to operate e the light source s for a short time e without a filter f then oonly pull the e slide out to t the first rest position. When in th his position , the filter is still in the e light sourcce, but no longer l in the light path. 10/15 1 KL 1500 H HAL / KL 1500 1 H - Operating O instructio ons 3. Lamp c change Safe ety inform mation: ATTENTIO ON! t lamp and lamp so ocket have cooled do own before replacing the lamp. A Please ensure that the gn has been attached to remin nd you of th his necessity y. warning sig Please enssure that the e light sourc ce is switch hed off and the power plug p is pulleed out. Please be careful not to grasp intto the devicce. There is a risk of injjury by the ttrailing fan. artment (9) by pressin g down and d pulling at the designaated recess s and pulling Open the llamp compa the compa artment out as far as itt will go. Mo ove the lam mp including g socket upp and out of o the holder. Carefully p pull the defe ective lamp off the sockket and slip p on a new lamp (use a lamp that correspond ds to the specifications given g under Point 6.4)). Proceed by pressing g down on the lamp until u it snap ps into place inside the holder. Slid de the lamp p compartm ment back in n until it loccks (audibly y) into place e. Insert the p power plug and switch on the lightt source. ocket: Replacing the lamp so to last for 20,000 quality lamp socket is guaranteed g 2 The high q operating h hours or 20 lamp replacements. When repla acing the la amp socket,, start by ca arefully pulling off the lamp as de escribed above. Use a screwdrive er to loosen both fastening sscrews at th he top of the e clip and re emove the component completely. Thread th he two cablle ends of th he socket (spare partt, see Pointt 6.4) into th he correspo nding open nings on the clip and d retighten the screws (making su ure they are e seated firmly). Slip p the lamp back b on and d press it in nto the holde er as described above. 11/15 1 KL 1500 HAL / KL 1500 H - Operating instructions 4. Maintenance Your KL 1500 HAL is maintenance free. Disinfecting the light source during medical applications is to be avoided. To clean the outside of the instrument, use a soft dry cloth or commercially available plastic cleaning cloths. 5. Troubleshooting Should you be unable to correct the fault you are experiencing applying the measures listed below, turn to your authorised dealer or the next SCHOTT dealership. More extensive repairs have to be performed by authorised service technicians. Errors and faults are commonly displayed on the LCD display (5) (see Point 2.5): Overheating: Insufficient cooling; temperature monitor has triggered Open Circuit: Lamp circuit interrupted; lamp defective or missing No Fan: Fan defective No Light Guide: no light guide in the light guide socket (2) Type of the fault Possible cause Remedy Lamp off, fan not running, no LCD display Instrument not switched on Switch the instrument on Plug not in socket Insert the plug No mains voltage Check mains voltage Lamp compartment not connected Lamp defective Connect lamp compartment Replace lamp (see Point 3 of these instructions) No lamp Insert lamp with light source switched off No lamp contact Press lamp into the socket Lamp off, fan running, fault status indication "Open Circuit" 12/15 KL 1500 HAL / KL 1500 H - Operating instructions Lamp off, fan running, fault status indication "Overheating" Electronics overheated Lamp off, fan not running, fault status indication "No Fan" Fan defective, impeller jammed Have authorised customer service perform repairs Lamp off, fan running, fault status indication "No Light Guide" No recommended light guide in Plug recommended light guide into the light guide socket, check the light guide socket for proper seating Light guide is not plugged in until it stops Provide for sufficient cooling, verify correct lamp type, place the instrument back into operation after an extended cooling period Plug in light guide into the light guide socket until it stops 6. Accessories for KL 1500 HAL A wide range of accessories is available for your KL 1500 HAL. A separate brochure gives you comprehensive information (turn to page 15 for the order address) Only SCHOTT light guides and accessories guarantee perfect operation, safety and optimum light yield. 6.1 Light guides Self supporting and flexible light guides in various lengths and diameters are available, as well as point and slit illuminators. 6.2 Halogen lamps When ordering halogen lamps as spare parts (see point 6.4 of these instructions), you will receive the lamp type that gives you the maximum light yield and best possible degree of illumination. 6.3 Filters Optical filters can either be inserted into the filter slide (7) or placed in front of the light guide exit as a screw in or push on filter in conjunction with an auxiliary focussing device (accessory). Details of the auxiliary focussing device and the filter types available as standard can be found in the accessories catalogue. 13/15 KL 1500 HAL / KL 1500 H - Operating instructions 6.4 Spare parts Halogen lamp 15 V / 150 W Philips, type 6423 Philips, type 6423 XHP Osram, type HLX 64634 (catalogue no. 153000) Lamp socket (catalogue no. 150710) Only the use of the spare parts listed above will ensure maximum performance, light yield and safety. 7. Technical data KL 1500 HAL Properties Values General information Type description - KL 1500 HAL Dimensions (W x D x H) mm approx. 202 x 146 x 286 Weight kg approx. 4,2 Cooling - Axial fan Ambient temperature °C + 5 ... + 40 Relative humidity % at 31°C ambient temperature: 85% 31°C to 40°C ambient temperature: linearly decreasing to 75% Air pressure hPa 800 ... 1060 Transport and storage Temperature Rel. humidity Air pressure °C % hPa -20 ... +70 10 ... 95 (non-condensing) 500 ... 1200 Electrical information Operating voltage, frequency Power consumption, max. Protection class 100 - 240 V ~ 50 - 60 Hz VA max. 180 - I II Overvoltage category Lamp type - Halogen reflector lamp Philips, type 6423 Philips, type 6423 XHP Osram, type HLX 64634 Lamp rated voltage V 15 Lamp rated power W 150 Average lamp lifetime Level 50% Level 80% Level 100% h h h 1500 150 50 14/15 KL 1500 H HAL / KL 1500 1 H - Operating O instructio ons nformation Lighting in Maximum e effective ligh ht guide bund dle diameter mm m 9 Total light fflux at light guide g exit (SCHOTT light guide Ø 9 mm, typ. values) Level 50% Level 80% Level 100% % approx.. 250 approx.. 450 approx.. 600 lm m lm m lm m Light entry angle (2 efff ) approx.. 85° Heat protecction filter - Markings - Approvals - EMC emisssion class - SCHOT TT KG 2, 45 x 45 d = 2.0 mm, toughened B The right iss reserved to t make cha anges in the e design an nd supplied items withinn the scope e of on-going technical d developmen nt. WEEE Declaration High-quality materials and componen nts have been us sed during t production o of your SCHOTT T product. the devvelopment and the This syymbol means that electrical and d electronic equ uipment must be disp posed of separa ately from your h household waste after they have re eached their end-of-life. SCHOT TT AG Lighting and Imaging ha ave arranged fo or a return system m that customers s can use to disspose of their eq quipment. Please e make use of th his system to disspose of your product. Join us in helping preserve e the environme nt in which we live. ore information on o our return syystem, log on to For mo www.schott.com/lightin ngimaging/recyccle. Manufactturer’s Ad dress: SCHOTT AG Lighting a and Imaging Division Otto-Scho ott-Strasse e2 55127 Ma ainz Germany 6 -0 Tel. +49 (0) 6131 / 66 15/15 1 KL 1500 HAL / KL 1500 H - Mode d'emploi Mode d'emploi KL 1500 HAL / KL 1500 H* Version : Mars 2016 * Nom différent de KL1500H possible. Pour des raisons de simplicité cette notice ne mentionne que le nom de KL 1500 HAL. 1/15 KL 1500 HAL / KL 1500 H - Mode d'emploi Sommaire 1. Remarques importantes ...................................................................... 4 2. Mode de fonctionnement ..................................................................... 6 2.1 Raccordement du conducteur de lumière ............................................ 6 2.2 Raccordement au secteur ............................................................... 6 2.3 Mise en service ................................................................................. 7 2.4 Réglage de l'intensité lumineuse ......................................................... 7 2.5 Affichage et réglages de l'écran LCD …......……………………….…. 8 2.6 Optique supplémentaire .....……………………………………….…… 2.7 Tiroir porte-filtre .................................................................................. 10 3. Remplacement de la lampe ............................................................... 4. Maintenance ....................................................................................... 12 5. Dépannage……………………………................................................... 12 6. Accessoires ......................................................................................... 13 7. Caractéristiques techniques ............................................................... 14 9 11 2/15 KL 1500 HAL / KL 1500 H - Mode d'emploi Vue d'ensemble de l'appareil 2 5 8 7 12 4 6 1 3 9 11 (1) Interrupteur principal (2) Entrée du conducteur de lumière avec coupure automatique 13 10 2.3 de l’alimentation de la lampe 2.1 (3) Vis de serrage 2.1 (4) Réglage électronique de l'intensité lumineuse 2.4 (5) Écran LCD 2.5 (6) Levier de l’optique supplémentaire 2.6 (7) Tiroir porte-filtre 2.7 (8) Poignée de transport 1. (9) Compartiment de lampe avec lampe halogène à réflecteur de lumière froide 3. (10) Raccord du câble secteur 2.2 (11) Ouvertures d'aération (fond de l'appareil) 1. (12) Grille d'évacuation (arrière de l'appareil) 1. (13) Plaque d’identification (fond de l'appareil) 1. 3/15 KL 1500 H HAL / KL 1500 1 H - Mode M d'em mploi 1. Rema arques im mportanttes Symboles s utilisés : Sym mbole Signification Ave ertissement : zone dange ereuse (attention : respec cter la docum mentation) Ave ertissement : surfaces cha audes Utilisation approprriée : La source de lumière froide KL 1500 1 HAL e est conçue pour p une utilisation danns le milieu industriel et e en laborato oire. Les source es de lumière froide se ervent à l'écclairage inte ensif d'objets s de toutes sortes. Les s proportion ns d'infraroug ges du rayo onnement de la lampe e sont filtrée es. Une lum mière visiblee d'intensité é élevée esst guidée verrs l'objet parr le biais d'u un conducte eur de lumiè ère flexible ou autoport rteur. Conformém ment la norm me EN 62471:2008, la a KL 1500 HAL H est un produit p de laa classe de risque 1. La source de lumière halogène pour p fibre o optique KL 1500 HAL respecte r less termes de es directive es suivantes d de la comm munauté eurropéenne. 2014/35/UE (Directive e relative au ux faibles te ensions) e CEM) 2014/30/UE (Directive e RoHS) 2011/65/EU (Directive mité avec le es exigence es élémenta d su usmentionnnées est jus stifiée par la aires des directives La conform documenta ation technique, ainsi que q par le re espect totall des norme es suivantess : EN 61326--1:2013 EN 61010--1:2010 EN 50581::2012 UL 61010--1 Third Edition und CA AN/CSA-C2 22.2 No.611010-1-12 Con nsignes de e sécurité é: Veuillez liire et resp pecter scru upuleusem ment ce mo ode d'emp ploi. En caas de non-respect, la sécurité d de l'appareiil n'est pas s assurée. Durant le fonctionn nement, ne e jamais rregarder directementt dans l'orrifice de sortie s de la source de e lumière ou du condu ucteur de l umière (ris sque de lés sions oculaaires) ! Une lumière visible de haute inttensité est é émise par la l KL 1500 HAL. Les matériaux absorbant a la lumière ayyant la capa acité physiq que de transsformer la lumière l inciidente en cchaleur, les matériaux à absorption lumineuse e inflammab bles et senssibles à la chaleur c peuvent subir ddes dégâts. Pour évite er de tels dég gâts thermiq ques et un incendie po otentiel ou des d risques de brûluress, veuillez respecter r le es consignes suivantes : 4/15 KL 1500 H HAL / KL 1500 1 H - Mode M d'em mploi N'obture ez jamais la a sortie du conducteur c de lumière (risque d'in ncendie) ! Ne couvvrez jamaiss la sortie du conducte eur de lumiè ère avec la main ou d''autres parties du corp ps (risque de brûlure) ! e d'objets à absorption lumineuse e sensibles à la lumière re ou inflam mmables (pa ar En cas d'éclairage ex. en m microscopie e), il convien nt de choisi r la distance du conducteur de lum mière et l’in ntensité de la lampe d de telle sorte qu'aucune e détériorattion thermiq que ne peut atteindre l'oobjet. Toutes sorties de conducteurr de lumière es inutilisée es pendant la phase dde travail (appareil sou us tension)) doivent to oujours se trouver à une distan nce de séc curité – d’aau moins 10 1 cm – de matériau ux thermossensibles ou o inflamm mables abso orbant la lumière (poour éviter des risque es d’incend die). Il est in ndispensab ble que la diistance de sécurité me entionnée cci-dessus so oit respecté ée pour ce es sorties de d conducte eur de lum mière vis-à-v vis p.ex. de e textiles ssombres/collorées et de surfacess de bois ou u de plastiques sombre es/colorées s. Afin d’é éviter une réaction r ind désirables d de tissus biologiques due à la luumière visib ble, réduise ez l’intensité lumineusse et la duré ée d’exposittion au stric ct minimum nécessairee. Lors du brancheme ent de votre e appareil, vveillez à une e connexion n sûre à la tterre. Veuillez impérative ement vou us conform mer à ce qui q suit : votre e source de lumière fro oide KL 150 0 HAL doit être alimen ntée avec laa tension ind diquée sur la plaqu ue d’identification (13) ; toute es les ouve ertures d'aé ération (11, 12) doiven nt impérativ vement êtree dégagées s. En cas de refroidissement insuffisant, une sécu rité thermiq que intégrée éteint tem mporaireme ent l'appare eil ») ; (voir point 5 « Dépannage D la lam mpe doit êttre refroidie e avant d'êttre remplac cée. Un sym mbole d'aveertissementt est appossé danss la porte du u compartim ment de la la ampe pour vous v le rappeler : (Avertissem ment : surfac ces chaude es) ; oir porte-filtre et le filtre e intégré do oivent être refroidis ava ant le retraitt du filtre inttégré. Le le tiro tiroir est étiquettte avec le symbole s d'avvertissement ; le tiro oir porte-filtre doit en principe p être e enclenché é lors du fon nctionnemennt de la sou urce de lumiè ère (voir point 2.6 « Tirroir porte-filttre ») ! le co onducteur de e lumière doit être refro oidi avant d’être d remplacé. ère a été co onçue pour une utilisattion exclusiv vement danns des locau ux secs (vo oir La sourrce de lumiè point 7 « Caractérisstiques tech hniques »). pareil n'est pas p adapté à une utilissation dans des zones explosives.. Cet app Pour un ne isolation sûre du rés seau d'alime entation éle ectrique, déb brancher la prise. L'appareil ne doit pas être ouvert o ou d émonté. To oute modification techhnique de l'appareil esst interdite e. Les répa arations do oivent exclu usivement être ê effectu uées par lee fabricant ou par de es antenne es de servicce après-vente agréés.. Veuillezz-vous assu urer que ces conseilss d’utilisatio ons soient toujours à la portée de chaque utilisate eur. Le fabricant déclline toute responsab r bilité en cas s de domm mages qui sseraient du us à la non nobserv vation de mode m d’emp ploi. 5/15 KL 1500 H HAL / KL 1500 1 H - Mode M d'em mploi 2. Mode e de fonc ctionnem ment 2.1 Racco ordement du condu ucteur de llumière Tout d’abo ord tournez la vis de serrage s (3) de l’entrée e du conducteur de lu mière (2) dans d le sen ns contraire d des aiguilless d’une montre. Pousssez le conducteur de lu umière jusqqu’à la buté ée et tourne ez la vis de se errage danss le sens d’u une aiguille e d’une mon ntre pour serrer. Attention : en cas d'in nsertion de conducteurrs de lumièrre avec une e tige de guuidage, veillez à ce que cette dernière soit encclenchée da ans l'une de es deux fentes de guidage. Con nsignes de e sécurité é: ATTENTIO ON! Les condu ucteurs de e lumière peuvent p ch hauffer lors s d’une utilisation prrolongée. Viellez V à ce c que le con nducteur de d lumière soit s refroid di avant d’ê être rempla acé. Il est cconseillé d’éteindre d la source d de lumière e env. 5 min avan nt le remp placement du cond ducteur. Le L symbole d'avertissement v vous rappelle cette co onsigne. du conducte eur de lum mière (2) esst en plus dotée d'un n système de capteu urs (coupurre L’entrée d qui permet le fonctionn automatiqu ue de l’alimentation de e la lampe) q nement de la lampe un niquement si s un conduccteur de lum mière se trou uve dans l'o ouverture prévu p à cet effet. Ainsi,, il est impo ossible d'êtrre aveuglé e en cas de fonctionne ement sanss conducte eur optique e, comme par exemple lors du remplacem ment par mégarde m du conducteu ur de lumiè ère sans arrêter la soource de lu umière ave ec l'interrupteur principal (1). ucun conduccteur de lum mière ne se e trouve dan ns l’entrée du d conducteeur de lumière (2) alorrs Tant qu'au que la source lumière e est allumé ée, le messa age d'erreur « No Light Guide » ss'affiche surr l'écran LCD D (5). 2.2 Racco ordement au secteu ur : de type H05VVInsérer le câble d'allimentation tripolaire d a ) dans la prise F3G0,75 (disponible comme accessoire) prévue à ccet effet (10) à l'arrière de l'appare eil. Il est rac ccordé au secteurr (100-240 V CA, 50-60 0 Hz). S'assurer iimpérativem ment que vo otre source de lumière froide KL 1500 HAL fonctionne uniq quement da ans la plag ge de tension ind diquée. Lors du rremplaceme ent du câble d’alime entation, ve euillez utiliser un ccâble d’alim mentation du u même typ pe. 6/15 KL 1500 HAL / KL 1500 H - Mode d'emploi 2.3 Mise en service Allumer / Éteindre la KL 1500 HAL en actionnant l'interrupteur principal (1). Si l'appareil est allumé, l'affichage de l'écran LCD (5) s'allume. Position O : l'appareil est éteint. Pour isoler l'appareil du secteur, veuillez débrancher la prise ! La KL 1500 HAL est équipée pour préserver la lampe halogène avec un démarrage en douceur qui réduit le courant transitoire habituellement élevé. 2.4 Réglage de l'intensité lumineuse En tournant le régulateur d'intensité lumineuse (4) il est possible de régler l’intensité en continu. L’intensité réglée est indiquée sur l'écran LCD (5) en pourcentage en pas de 1 % de 0 à 100 %. En appuyant une fois sur le régulateur d'intensité lumineuse (4), il est également possible de l'indiquer sous forme de température de couleur équivalente enregistrée [Kelvin] au niveau de la sortie du conducteur de lumière. Attention : En l’occurrence il ne s'agit pas d'une grandeur physique exacte et cette valeur est sujette à une certaine imprécision ! Elle sert uniquement de valeur indicative ! Les variations dues à des tolérances de fabrication de la lampe et aux processus de vieillissement ne sont pas prises en compte ! L'intensité lumineuse maximale est atteinte en position 100 % (3 400 K). La durée de vie moyenne de la lampe est ainsi de 50 h environ (information fournie par le fabricant de la lampe). La plage de réglage de la KL 1500 HAL est divisée en 3 segments différents et elle est indiquée en conséquence sur l'écran LCD (5). Les plages peuvent être utilisées comme indicateur pour la clarté en fonction de l'application et ainsi pour la durée de vie de la lampe. ECO 0 - 49 % > 1 500 h STANDARD 50 - 79% env. 150 – env. 1 500 h BOOST 80 - 100% env. 50 – env. 150 h 7/15 KL 1500 HAL / KL 1500 H - Mode d'emploi En position 0% du régulateur aucune intensité n'est plus détectée, c'est-à-dire que la lampe est éteinte. Attention : lorsque le régulateur est en position 0 %, l'appareil n'est pas éteint. Pour éteindre la KL 1500 HAL, l'interrupteur principal (1) doit être actionné (voir point 2.3 « Mise en service »). Pour isoler l'appareil du secteur en toute sécurité, veuillez débrancher la prise ! La durée de fonctionnement totale de la lampe (indépendamment de l'intensité réglée) peut, en cas de besoin, être affichée sur l'écran LCD (voir point 2.5 « Affichage et réglages de l'écran LCD »). 2.5 Affichage et réglages de l'écran LCD Affichage de la clarté La clarté paramétrée sur le régulateur d'intensité lumineuse (4) peut être affichée en pourcentage ou en Kelvin (voir point 2.4). Le basculement est effectué en appuyant brièvement sur le régulateur d'intensité lumineuse (4). Affichage de la durée de fonctionnement de la lampe En cas de besoin, la durée de fonctionnement cumulée de la lampe halogène utilisée peut être affichée sur l'écran LCD (5). Elle est totalisée en heures complètes [h] au fur et à mesure de la durée de vie, indépendamment de la tension à laquelle la lampe fonctionne. La commande du menu permet d'activer ou de désactiver l'affichage. Afin d'accéder à la commande du menu, maintenir le régulateur d'intensité lumineuse (4) enfoncé pendant plus de 5 secondes. Pendant que la source lumineuse se trouve dans la commande du menu, la lampe est éteinte. En tournant le régulateur d'intensité lumineuse (4) vers la droite et la gauche, la flèche indicatrice se déplace dans les zones correspondantes du menu. La zone du menu activée est affichée de manière inversée. En appuyant brièvement une fois sur le régulateur d'intensité lumineuse (4), on accède au sous-menu sélectionné. 8/15 KL 1500 HAL / KL 1500 H - Mode d'emploi Pour activer l'affichage des heures de fonctionnement, veuillez choisir le sous-menu « On/Off ». En tournant le régulateur d'intensité lumineuse (4), choisir « On » et confirmer ce choix par une brève pression (une coche apparaît dans la zone de menu). Sélectionner « Menu », puis « Exit ». La lampe se rallume. Les heures de fonctionnement sont affichées en haut à gauche de l'écran LCD (5). Pour désactiver l'affichage des heures de fonctionnement, veuillez choisir le sous-menu « On/Off ». En tournant le régulateur d'intensité lumineuse (4), choisir « Off » et confirmer ce choix par une brève pression (une coche apparaît dans la zone de menu). Sélectionner « Menu », puis « Exit ». Si l'affichage des heures de fonctionnement de la lampe est utilisé, la durée d'heures de fonctionnement doit être réinitialisée sur 0 h après un remplacement de la lampe. Cela ne se fait pas automatiquement ! Pour ce faire, maintenir le régulateur d'intensité lumineuse (4) enfoncé pendant plus de 5 secondes pour accéder à la commande du menu. Veuillez choisir le sous-menu « Reset ». En tournant le régulateur d'intensité lumineuse (4), choisir « Reset » et confirmer ce choix par une brève pression (une coche apparaît dans la zone de menu). Sélectionner « Menu », puis « Exit ». Les heures de fonctionnement de la lampe sont désormais totalisées une nouvelle fois en commençant à 0 h, indépendamment du fait que l'affichage soit activé ou non. 2.6 Optique supplémentaire La mise en œuvre de l'optique supplémentaire garantit l'obtention d'un éclairage puissant et uniforme, même en utilisant des conducteurs de lumière dont le diamètre de fibrage est plus faible que 9 mm. Si l'éclairage est produit avec des systèmes optiques imageurs ou focalisateur à la sortie du conducteur de lumière, on obtient alors un éclairage régulier optimal lorsque l'optique supplémentaire est déployée. Pour relever ou déployer l'optique supplémentaire, tourner le levier (6) vers la gauche ou la droite sur le symbole correspondant. L'optique supplémentaire doit toujours être relevée ou déployée jusqu'à la butée finale ! 9/15 KL 1500 H HAL / KL 1500 1 H - Mode M d'em mploi 2.7 Tiroirr porte-filtrre La KL 1500 0 HAL est dotée d d'un tiroir t porte-ffiltre (7) qui peut être équipé d'un filtre intégré é (disponible comme accessoire). Le tiroir po orte-filtre do oit en princip pe se trouve er dans l'un ne des deux x positions dde butée ou u en positio on enclenchée e lors du fo onctionnement de la ssource de lu umière. C'e est la seule manière de garantir le refroidissement optimal de l'air de la source de lumière e. Con nsigne de sécurité : ATTENTIO ON ! Le fonction nnement de e la source lumineuse dans une position p inte ermédiaire ddu tiroir porrte-filtre peu ut occasionne er une dété érioration de e celui-ci. Equipeme ent du tiroirr porte-filtrre Con nsigne de sécurité : ATTENTIO ON ! Avant l’équ uipement du u tiroir porte e-filtre (7) a avec le filtre intégré, s'a assurer quee le tiroir soit refroidi. Le L symbole d''avertissem ment vou us rappelle de ne pas oublier o cette e consigne importante. mplètementt le tiroir po orte-filtre (7 ) de telle manière m que e l’inscriptioon soit visib ble (gauche). Retirer com Munissez-vvous de gants spéciau ux (anti-pou ssière) afin d’insérer le e filtre de diiamètre de 28 mm dan ns le support prévu à ce et effet. Le filtre doit ê être inséré à plat dans s le supporrt, derrière les fixation ns suivant le ssens de la flèche f (voir photos). Pour retire er le filtre éccartez légère ement la fixxation vers la l gauche et e le filtre tom pport. (Photto mbe du sup de gauche e) Si vous so ouhaitez utiliser la sourrce de lumiè ère brièvem ment sans filtre, ne sorttez le tiroir que q jusqu'a au premier crran. Dans cette c positio on, le filtre se trouve encore e dans la sourcee de lumière e, mais plu us dans faisce eau lumineu ux. 10/15 1 KL 1500 H HAL / KL 1500 1 H - Mode M d'em mploi acement de d la lamp pe 3. Rempla Con nsigne de sécurité : ATTENTIO ON ! S'assurer que la lam mpe et son support soient refrroidis avan nt le rempllacement. Le symbole d'avertisse ement vo ous rappelle e de ne pas oublier cette consigne e importantee. Vieillez à é éteindre la source s de lu umière et à débrancher le cordon d'alimentattion. S’assurer d de ne pas toucher l’intérieur de l ’appareil. Risque R de blessures een raison du ventilateu ur tournant. ompartimen nt de la lampe (9) en a baissant et en tirant au u niveau duu renfoncem ment prévu et e Ouvrir le co tirer jusqu'à la butée. Extraire la lampe, soccle inclus, du support par p le haut. Retirer avec précautio on la lampe d défectueuse e du socle et e insérer un ne nouvelle e lampe (veuillez utiliseer la lampe spécifiée au a point 6.4). Ensuite, pousser p à nouveau n la lampe dan ns son support par le haut jusqu u'à la butée e. Pousser le e logement de d la lampe e jusqu' jusq qu'à la buté ée (enclench hement auddible). Brancher la prisse et allumer la source de lumière. ment du soccle de la lam mpe : Remplacem La durée d de vie garan ntie du socle e de la lamp pe de haute e qualité est de 20 0 000 heures de fonction nnement ou 20 remplac cements de la lampe. placer le soccle de la lam mpe, comme encer par re etirer la Pour remp d plus h haut. Desse errer les lampe avec précaution, comme décrit deux vis de e fixation su upérieures de d la borne avec un tournevis et retirer l'é élément com mplet. Insérrer les deuxx extrémités s de câble du nouvea au socle (piè èce de rechange, voir p point 6.4) dans les orifices corrrespondants de la borrne et resse errer les vis (s'assurer qu'elles ne bougent pa as). Insérer de nouveau la enfoncer da ans le support, comme e décrit plus s haut. lampe et l'e 11/15 1 KL 1500 HAL / KL 1500 H - Mode d'emploi 4. Maintenance Votre KL 1500 HAL ne nécessite aucune maintenance. Une désinfection de la source de lumière en cas d'utilisation dans le secteur médical n'est pas prévue. Pour un nettoyage extérieur de l'appareil, utiliser un chiffon doux et sec ou des lingettes de nettoyage pour surfaces plastique courantes. 5. Dépannage S'il vous est impossible d'éliminer le dysfonctionnement à l'aide des mesures mentionnées ci-après, veuillez vous adresser à votre revendeur ou au représentant SCHOTT le plus proche. Toute autre réparation doit être exécutée par un service après-vente autorisé. Les défaillances et dysfonctionnements sont, en principe, affichés sur l'écran LCD (5) (voir point 2.5) : Overheating : refroidissement insuffisant ; la sécurité thermique a répondu. Open Circuit : circuit électrique de la lampe interrompu ; lampe défectueuse ou pas de lampe No Fan : ventilateur défaillant. No Light Guide : aucun conducteur de lumière dans l’entrée du conducteur de lumière (2) Nature de la panne Cause probable Solution Lampe éteinte, ventilateur éteint, pas d'affichage à l'écran L'appareil n'est pas allumé Allumer l'appareil La fiche d’alimentation n'est pas dans la prise Insérer la fiche d’alimentation Pas de tension secteur Vérifier la tension secteur Compartiment de la lampe pas fermé Lampe défectueuse Fermer le compartiment de la lampe Remplacer la lampe (voir point 3 de ce mode d'emploi) Pas de lampe Installer la lampe lorsque la source de lumière est éteinte Pas de contact au niveau de la lampe Pousser la lampe dans son support Lampe éteinte, ventilateur en fonctionnement, indication du statut d'erreur « Open Circuit » 12/15 KL 1500 HAL / KL 1500 H - Mode d'emploi Lampe éteinte, ventilateur en Surchauffe de l’électronique fonctionnement, indication du statut d'erreur « Overheating » S'assurer que le refroidissement est suffisant, vérifier si le type de la lampe est correct, remettre l'appareil en service après un refroidissement prolongé. Lampe éteinte, ventilateur éteint, affichage du statut d'erreur « No Fan » Ventilateur défaillant, rotor bloqué Faire réparer par un service après-vente agréé Lampe éteinte, ventilateur en fonctionnement, indication du statut d'erreur « No Light Guide » Aucun conducteur de lumière monté Insérer le conducteur de lumière dans son logement et s'assurer qu'il ne bouge pas 6. Accessoires pour KL 1500 HAL Une large gamme d'accessoires est disponible pour votre KL 1500 HAL. Une brochure séparée vous informe en détail (adresse pour une demande voir page 15) Seuls les conducteurs de lumière et les accessoires SCHOTT garantissent un fonctionnement et une sécurité sans faille ainsi qu'un rendement de lumière optimal. 6.1 Conducteur de lumière Des conducteurs de lumière flexibles et autoporteurs de différentes longueurs et de différents diamètres, ainsi que des éclairages annulaires ou linéaires sont disponibles. 6.2 Lampe halogène En cas de commande de lampes halogène sous forme de pièces de rechange (voir point 6.4 de ce mode d'emploi), le type de lampe livré est celui qui permet un rendement de lumière et un éclairage optimaux. 6.3 Filtre Des filtres optiques peuvent être introduits dans le tiroir porte-filtre (7) ou placés en amont de la sortie du conducteur de lumière en association avec un élément focalisateur (accessoire). Vous trouverez des détails sur l’élément focalisateur et sur les types de filtres standards disponibles dans la brochure des accessoires. 13/15 KL 1500 HAL / KL 1500 H - Mode d'emploi 6.4 Pièces de rechange Lampe halogène 15 V / 150 W Philips, modèle 6423 Philips, modèle 6423 XHP Osram, modèle HLX 64634 (Réf. 153000) Socle de lampe (Réf. 150710) Seule l'utilisation des modèles de pièces de rechange indiqués permet d'assurer un fonctionnement et une sécurité sans faille, ainsi que des rendements de lumière optimaux. 7. Caractéristiques techniques KL 1500 HAL Caractéristiques Valeurs Indications générales Désignation du modèle - KL 1500 HAL Dimensions (l x p x h) mm env. 202 x 146 x 286 Masse kg env. 4,2 Refroidissement - Ventilateur axial Température ambiante* °C + 5 ... + 40 Humidité relative de l'air* % Jusqu’à une température ambiante de 31 °C maxi. : 85% à une température ambiante de 31 °C à 40 °C : décroissance linéaire jusqu'à 75 % Pression atmosphérique hPa 800 ... 1060 Transport et stockage Température Humidité relative de l'air Pression atmosphérique °C % hPa -20 ... +70 10 ... 95 (sans condensation) 500 ... 1200 Caractéristiques électriques Tension de fonctionnement, fréquence Puissance maxi. absorbée Classe de protection 100 - 240 V~ 50 - 60 Hz VA max. 180 - I II Catégorie de surtension Type de lampe - Lampe à réflecteur halogène Philips, modèle 6423 Philips, modèle 6423 XHP Osram, modèle HLX 64634 Tension nominale de la lampe V 15 Puissance nominale de la lampe W 150 Durée de vie moyenne de la lampe Niveau 50 % Niveau 80 % Niveau 100 % h h h 1500 150 50 14/15 KL 1500 H HAL / KL 1500 1 H - Mode M d'em mploi Caractéris stiques tech hniques de la a lumière Diamètre d de faisceau utile u maximal du conducte eur de lumière en termes de d technique de lumière mm m 9 Flux lumine eux total en sortie s du con nducteur de lumière (Conducteu ur de lumière e SCHOTT Ø 9 mm, valeurs typ piques) lm Niveau 50 % lm Niveau 80 % m lm Niveau 100 0% m 50 env. 25 env. 45 50 env. 60 00 Angle d'ém mission de la lumière (2 eff ) env. 85 5° Filtre anti-ccalorique - Conformité é - Marque de e contrôle - Classe d’émission CEM M (compatibilité électromag gnétique) - SCHOT TT KG 2, 45 x 45 d = 2,0 mm, trempé é B Sous réserrve de modifications du u modèle ett du contenu de livraiso on dans le ccadre du développement technique. Déclarration DEEE Votre produit p SCHOTT T a été conçu ett fabriqué avec des matéria aux et des comp posants haut de e gamme. Le sy ymbole signifie e que les appare eils électriques e et électroniques s doivent être éliminés séparém ment des déchetss ménagers à la a fin de leur d vie d'utilisatio on. durée de SCHOT TT AG Lighting and Imaging a mis en place un n système de reprrise pour le recy yclage. Veuillez utiliser ce systè ème pour le recycla age de l'appareil. Contribuez à la préservation de notre environ nnement. Vous trrouverez de plus amples inform mations sur le sy ystème de reprise e sur www.schottt.com/lightingim maging/recycle. Distribute eur: SCHOTT FRANCE Départem ment Lightin ng and Ima aging 6Bis, Rue e Forunier F – 92110 0 CLICHY Tel. + 33 (0)1 40 87 7 39 46 15/15 1 Lighting and Imaging SCHOTT AG Hattenbergstr. 10 55122 Mainz Germany Phone: +49 (0)6131/66-7796 Fax: + 49 (0)6131/66-7850 [email protected] www.schott.com/lightingimaging