StoreWay™ Optima4600
Transcription
StoreWay™ Optima4600
Mid-range storage StoreWay™ Optima4600 The ideal solution for entreprise environments StoreWay Optima4600 offers availability, capacity and performance for virtualized entreprise applications • Fibre Channel 8Gb/s, iSCSI 1 or 10Gb/s host connections • SAS 6Gb/s back-end with up to 960 drives, 2.5’’ or 3.5’’ form factor • Improved architecture and latest processor technology doubling the performance • Performance and efficiency improved by SSD cache and block level auto-tiering • Storage adapted to virtualized environments • Complete software offer with thin provisioning, snapshot, local and remote replication, performance optimization, virtual cache partitioning A highly performant architecture Optima4600 is designed to build highly performant and capacitive storage solutions. Its architecture leans on multi-core processors of the latest generation and offers four times the internal throughput of the already powerful Optima3600. Optima4600 offers up to 48 host connectivities in Fibre Channel and iSCSI. SSD, SAS and NLSAS disk drives can be connected through 32x SAS 6Gb/s links, bringing a great flexibility to build performant and highly capacitive solutions. Optima4600 supports upto 960 drives and a user capacity of 2,8 PBytes. Improved efficiency of Optima4600 Autonomic data allocation improves the efficiency of the storage by the analysis of the frequency of access to data and, according to the defined policy, the launch of an immediate or programmed data migration of blocks of data, from SAS or NL-SAS drives to SSD drives or vice-versa. This feature allows to limit the number of disk drives to the useful capacity and to reach the required performance by taking benefit of the SSD drives for the frequently used data. SSD cache significantly improves performance of transactional applications by moving hot data into the SSD cache. High availability and reliability Full redundant architecture with dual RAID controllers, mirrored cache, quadruple power supplies and fans, makes Optima4600 guarantee a 99,999% availability. Cache continuity is achieved by flash backup and controllers, disk drives, power supplies can be hot swapped undisruptively. Optima4600 tolerates a single disk failure in RAID-1/10, RAID-5/50 and a double disk failure in RAID-6 or RAID Triple Mirror. Super-Phoenix self healing technology reduces the number of disk drive replacement by repairing and recovering from suspected drive failures. Data protection is achieved by local replication or snapshot software and by remote replication between Optimas, whatever the model of Optima. Virtual Cache Partitioning achieves quality of service by allocating cache segments to an application and garanteeing its performance whatever the load of the other applications. Performance Monitor displays real time performance of Optima4600 and Performance Navigator analyzes performance evolution and predicts future saturations. Performance Optimizer detects bottlenecks and manages data migration to unloaded pools to balance the disks load and optimize the behaviour of the Optima4600. Virtualized environments Optima4600 is well fitted to VMware or Microsoft Hyper-V virtualized environments. In addition to the basic VMware and Site Recovery Manager certifications, a vSphere WEB client, a vCenter plug-in, vStorage APIs for Array Integration(vAAI) and vStorage APIs for Storage Awareness (VASA) are available. Also a plug-in Path Selection Architecture (PSA) is integrated in StoreWay Multipath for VMware. Ease of installation and Administration Optima Storage Manager manages all Optimas of a site from a central point. It manages the configuration of the disk array and all the optional software. Each Optima can also be configured by a manager embedded in the disk array. Migration from an existing storage to Optima4600 is easily achieved off-line by a Data Migration feature. It allows a quick start of the exploitation of the new storage with the existing data. Optima4600 connectivity ensures interoperability with Windows, Linux, HP-UX, Solaris, AIX and VMware. Server data access is secured by Storeway Multipath software available for Windows, Linux, VMware and AIX. Optima4600 software offer Optima4600 natively embeds Thin Provisioning ans Power Saver. Thin Provisioning optimizes the disk capacity and adapts this capacity to the increasing needs of the applications by managing thresholds at the LUN or pool level. Power Saver saves power consumption by stopping unactive disks, eg back-up drives outside of the back-up windows. www.bull.com Services and Support Bull provides professional services for an optimal operation. StoreWay™ Optima4600 Technical Specifications GLOBAL CHARACTERISTICS PHYSICAL SPECIFICATIONS (Cont'd) Rack chassis version Weight Disk Array Controller Unit Disk Enclosure Controller Unit 47Kg 29kg Height standard EIA Disk Array Controller Unit Disk Enclosure Controller Unit 4U or 4 EIA 2U or 2 EIA Total Storage Capacity Disk modules (hot swap) RAID capability Interface to host Max number of port to host Max number of channels to disks Power Supply Redundancy Fan Redundancy 4U base including controllers, add 2U disks drawers; 12x3.5’’ slots drawer or 24x2.5’’ slots drawer; maximum 960 disks (whatever the drawer type) Up to 1.1 PB SAS or 3.8 PB NL-SAS 3 to 960 disks RAID0, 1, 5, 6, 10, 50 and Triple Mirror 8 or 16 Gb/s Fibre Channel, 1 Gb/s iSCSI, 10Gb/s iSCSI 8 or 16/48x FC, 4/24x iSCSCI 1Gb/s, 4/24x 10Gb/s 32x SAS 6Gb/s links Yes Yes POWER Power consumption (basic chassis) Power consumption (add-on disk encl.) Voltage ENVIRONMENTAL CONSTRAINTS CONTENT OF BASIC CHASSIS RAID controller Cache memory per RAID controller Host Port Extension Disk Port Extension Hot-Plug Power Supply Battery Backup (BBU ou SPS) Host Management Operating constraints Dual controller FC 8 or 16Gbps, iSCSI 1Gb or 10Gb, combo FC+iSCSI 1Gb or 10Gb 24GB or 48GB per controller (96GB max total for the Optima4600) 8ports FC 8 or 16Gbps HPE, 4ports iSCSI 1 or 10G HPE (6 HPE max) 8ports SAS 6Gb (4 DPE max) (total HPE+DPE=8) Yes BBU for copy of cache in flash on the controller in case of power down LAN TCP/IP, FC SES, snmp, smis provider, email events Windows Server 2012 Windows Server 2008 Windows Server 2003 Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 Unix Other OS Disk Port Extension Cache memory upgrade Hard Disk Drives 7.2Krpm Hard Disk Drives 10Krpm Hard Disk Drives 15 Krpm Solid State Drives Yes including WSFC clusters Yes including WSFC clusters Yes including MSCS clusters RHEL 5.5, 5.6, 5.7 RHEL 6.1, 6.2, 6.3 AIX 5.3, AIX 6.1, AIX 7.1 including ARF for AIX, HP-UX, Solaris VMware ESX/ESXi 4.0, 4.1, ESXi 5.0, ESXi 5.1 REGULATORY & SAFETY Regulatory compliance Host Port Extension 5-40°C, 10%-80% SOFTWARE CERTIFICATION OPTIONS ON TOP OF BASIC CHASSIS Additional RAID controller /SP FC : 1100W ; iSCSI 1G : 1090W; iSCSI 10G : 1130W 3,5’’ SAS15k 315W; NL-SAS 260W ; 2,5’’ SAS10k 310W DAC : 4 plugs ; DE : 2 plugs AC100 à 240V; 50/60 Hz UL, CSA, CE, FCC WARRANTY Upgrade Host Port extensions or Disk Port Extensions Up to 6x 8ports FC 8 or 16Gbps HPE, up to 4x 4ports iSCSI (6 HPE max) Up to 4x 8ports SAS 6Gb (4 DPE max) (total HPE + DPE = 8) Upgrade 24GB to 48GB per controller 3,5’’ : 2TB, 3TB, 4TB 2,5’’ : 300 GB, 600GB, 900GB, 1.2TB 2,5’’ : 300GB; 2,5’’ and 3.5’’ : 200GB and 800GB Standard warranty Warranty extension 3 Years, Parts only (CRU) for hardware Bull Global Care : bronze, silver or gold (according to localisation) STORAGE MANAGEMENT SOFTWARE © 2017 Copyright Bull SAS All rights reserved - On-the-fly printed on 2/8/2017 12:39:57 AM Storage Management Multi-path Management StoreWay Optima Manager StoreWay Multipath for Windows and Linux StoreWay Multipath for VMware StoreWay Multipath for AIX LUN mapping/Multi-server storage accessYes Performance Monitoring Performance Monitor, Performance Navigator, Performance Optimizer, Performance Monitor Suite, Performance Optimizer Suite (options) Snap Shot Dynamic snap volume (included with Local Data Replication) Local Data Replication Local data replication (option) Remote Data Replication Remote data replication/Consistency, Data Migration (options) Other Thin Provisioning, Power Saver (included with hardware) SSD cache, Virtual Cache Partitioning, SQL replication, Volume WORM , SecureEraser (options) PHYSICAL SPECIFICATIONS Size of Rack chassis (HxWxD) Disk Array Controller Unit Extension module rack size (HxWxD) 175.4 x 480 x 602.5 mm 87.8 x 482x 513.2 mm Bull SAS - RCS Versailles B 642 058 739 - All trademarks mentioned herein are the property of their respective owners. Bull reserves the right to modify this document at any time without prior notice. Some offers or parts of offers described in this document may not be available locally. Please contact your local Bull correspondent to know which offers are available in your country. This document has no contractual significance. Bull SAS - rue Jean Jaurès - 78340 Les Clayes-sous-Bois – France UK : Maxted Road, Hemel Hempstead, Herts HP2 7DZ USA : 285 Billerica Road, Chelmsford, MA 01824 www.bull.com