MA89 Installation Programming the alarm
Transcription
MA89 Installation Programming the alarm
MA89 Motion Detector Alarm with Auto Dialer and remote keyfob Controls 1. Motion Sensor 2. Speaker 3. Mic 4. Low battery light The alarm unit has a permanent memory for stored telephone numbers and the recorded voice message. To change the telephone number or recorded message, repeat above. Using the unit as a silent alarm. You have the option to disable the siren by pressing 5. Keypad 6. Telephone Plug Socket 7. Code button 8. Battery Compartment . To retrieve the siren press Connection to the telephone unit 1 Remove the screw at the base of the alarm unit. 2 Remove the back plate and connect the telephone cable to socket of main unit 6 shown on fig A. The other end of the cable is connected into the telecom wall socket. Operation Battery installation 1. 2. 3. The battery compartment is accessed from the rear of the alarm unit by removing the screw from the base of the unit and lifting the rear coverfixing bracket as shown on C. Insert three AA size batteries (not included) following the polarity as shown on D. When the last battery is inserted the alarm will beep very loudly to indicate that the batteries are installed properly. Replace the back cover and fix with screw. The Low battery warning indicator light will illuminate when the batteries need replacing. Installation 1. 2. 3. Place the alarm in the desired location. Remove the rear cover and fix it to the wall using the screws supplied. The alarm body can then be snapped into place onto the rear cover and secured using the screw at the base of the unit. Note: The key fob uses 1 piece A23S battery (included). If the low battery indicator is 'On', simply remove and replace with fresh battery. Please note: This alarm can also be used in a free standing position. Programming the alarm 1. 2. Press the code button 7 of main unit shown on figure A and press ‘On’ button of remote keyfob at same time to learn the remote keyfob. After learning remote keyfob with main unit, simply press ‘On’ or ‘Off’ button of RF keyfob to arm or disarm the unit. Leaving the protected area Press ‘On’ button of remote keyfob to arm the unit. You now have 30 seconds to vacate the area. After this time, if motion is detected the alarm will start to dial the stored telephone numbers and the alarm siren will sound 20 seconds after the first telephone number is dialed. Entering the protected area Press ‘Off’ button of remote keyfob within 10 seconds and this will disarm the alarm. When the unit is activated, it will dial the first telephone number stored. If the first telephone number is not answered within 45 seconds the second stored number will be dialled and so on. All three stored telephone numbers will be dialled if the unit is activated unless you press ‘Off’ button of remote keyfob to disarm the alarm. Detection Area Care and maintenance To clean the case, simply use a soft slightly damp cloth with water and wipe dry immediately. Caution: Never use chemicals to clean the case, as they may cause damage to the plastic and cause the alarm not to function. Trouble shooting The unit does not sound when the batteries are installed Ensure that the batteries are connected correctly according to the diagram in the battery compartment The alarm does not arm Ensure that the back plate of the alarm unit is secure to hold the batteries in place and that the red light comes on when the keypad buttons are pressed The red light located in the middle of the alarm 4 is on This is the low battery warning indicator light. The batteries need replacing Storing telephone Number Press and store 1st group of telephone No. and press to confirm storing. Press for 2nd group of telephone No. and so on. Maximum 3 sets of telephone number with max 16 digits can be stored. Note: Only use friends and families telephone numbers. Do not use emergency service numbers. Can be used with a PABX phone system. Recording a message Press the low battery indicator light will illuminate, you now have 6 seconds to record your personal message. Once the light goes off your recording time is over. Suggested message: This is an alarm call from? Battery precautions When using this product follow these precautions at all times. · Use only the appropriate size batteries · Be sure to follow the correct polarity when installing the batteries as indicated in the battery compartment. Incorrect polarity may cause damage to the alarm. · Do not mix different types of battery such as Alkaline and Carbon-zinc or old batteries with new. · If the alarm is not used for long periods of time, remove the batteries to prevent damage or injury from possible battery leakage. · Do not recharge batteries not intended to be recharged as they can overheat and rupture. (Always follow the manufacturer's directions.) DECLARATION OF CONFORMITY Company Address, City EDEN S.A.S Centre de Puissanton 181 chemin de Puissanton 06220 VALLAURIS France Country Declares that the product: Description Product number Trade mark KONFORMITATSERKL ARUNG Firma Land EDEN S.A.S Adresse Centre de Puissanton 181 chemin de Puissanton 06220 VALLAURIS France Erklärung des Produktes: Mini alarm + PSTN dialler M A89 EDEN Artikelbeschreibung Artikel-Nr.: Markenname: Minialarm mit Telefonwahlgerät M A89 EDEN Is herewith confirmed to comply with the requirements set in the Council Directive on the Approximation of the Member States relating to: Hiermit bestätigen wir, um die Anforderungen aus den Richtlinien des Rates über die Annäherung der Mitgliedsstaaten zu befolgen, die Anerkennung folgender Richtlinien: Electro Magnetic Compatibility Directive R&TTE Directive Elektromagnetische Verträglichkeit (EMC) R&TTE-Anforderung (89/336/EEC) (1999/5/EEC) (89/336/EEC) (1999/5/EEC) Assessment of compliance of the product with the requirements relating to EMC was based on the following standards: EN 301 489-1 V1.8.1 (2008-04) EN 301 489-3 V1.4.1 (2002-08) Die Bewertung des Produktes bezüglich der Anforderung bezüglich EMC basiert auf den folgenden Standards: EN 301 489-1 V1.8.1 (2008-04) EN 301 489-3 V1.4.1 (2002-08) The requirements relating RF was based on the following standard: EN 300 220-2 V2.1.2 (2007-06) Die Anforderungen bezüglich RF basiert auf den folgenden Standards: EN 300 220-2 V2.1.2 (2007-06) The requirements relating to the telephone network compliance have been checked per following standard EN 301 437 V1.1.1 (TBR 37) Die Anforderungen bezüglich Telefon Netzwerk basiert auf folgenden Standard: EN 301 437 V1.1.1 (TBR 37) DECLARATION DE CONFORMITE Société Adresse/Ville Pays EDEN S.A.S Centre de Puissanton 181 chemin de Puissanton 06220 VALLAURIS France Déclarons que le produit : Description Référence produit Marque de commercialisation Mini alarme + transmetteur M A89 EDEN Est certifié conforme aux exigences définies dans la Directive du Conseil d’approximation des Etats Membres suivante : Compatibilité Electro magnétique Directive R&TTE (89/336/EEC) (1999/5/EEC) L’évaluation de conformité du produit par rapport aux exigences de Compatibilité Electro Magnétique a été effectuée sur la base des normes suivantes : EN 301 489-1 V1.8.1 (2008-04) EN 301 489-3 V1.4.1 (2002-08) Authorized representative: Mr. Pierre Van Der Deure Les exigences radio ont été vérifiées par rapport à la norme suivante : EN 300 220-2 V2.1.2 (2007-06) Les exigences téléphoniques ont été vérifiées par rapport à la norme suivante EN 301 437 V1.1.1 (TBR 37) Date: 07.09.2010 DECLARATION OF CONFORMITY IN OTHER LANGUAGES ON WWW.ELRO.EU