MA89 Installation Programming the alarm

Transcription

MA89 Installation Programming the alarm
MA89
Motion Detector Alarm with Auto Dialer and
remote keyfob
Controls
1. Motion Sensor
2. Speaker
3. Mic
4. Low battery light
The alarm unit has a permanent memory for stored telephone numbers
and the recorded voice message. To change the telephone number or
recorded message, repeat above.
Using the unit as a silent alarm.
You have the option to disable the siren by pressing
5. Keypad
6. Telephone Plug Socket
7. Code button
8. Battery Compartment
. To
retrieve the siren press
Connection to the telephone unit
1 Remove the screw at the base of the alarm unit.
2 Remove the back plate and connect the telephone cable to socket of
main unit 6 shown on fig A. The other end of the cable is connected into
the telecom wall socket.
Operation
Battery installation
1.
2.
3.
The battery compartment is accessed from the rear of the alarm unit by
removing the screw from the base of the unit and lifting the rear coverfixing bracket as shown on C.
Insert three AA size batteries (not included) following the polarity as
shown on D. When the last battery is inserted the alarm will beep very
loudly to indicate that the batteries are installed properly.
Replace the back cover and fix with screw.
The Low battery warning indicator light will illuminate when the batteries
need replacing.
Installation
1.
2.
3.
Place the alarm in the desired location.
Remove the rear cover and fix it to the wall using the screws supplied.
The alarm body can then be snapped into place onto the rear cover
and secured using the screw at the base of the unit.
Note: The key fob uses 1 piece A23S battery (included). If the low battery
indicator is 'On', simply remove and replace with fresh battery.
Please note: This alarm can also be used in a free standing position.
Programming the alarm
1.
2.
Press the code button 7 of main unit shown on figure A and press ‘On’
button of remote keyfob at same time to learn the remote keyfob.
After learning remote keyfob with main unit, simply press ‘On’ or ‘Off’
button of RF keyfob to arm or disarm the unit.
Leaving the protected area
Press ‘On’ button of remote keyfob to arm the unit. You now have 30
seconds to vacate the area. After this time, if motion is detected the alarm
will start to dial the stored telephone numbers and the alarm siren will
sound 20 seconds after the first telephone number is dialed.
Entering the protected area
Press ‘Off’ button of remote keyfob within 10 seconds and this will disarm
the alarm.
When the unit is activated, it will dial the first telephone number stored. If
the first telephone number is not answered within 45 seconds the second
stored number will be dialled and so on.
All three stored telephone numbers will be dialled if the unit is
activated unless you press ‘Off’ button of remote keyfob to disarm
the alarm.
Detection Area
Care and maintenance
To clean the case, simply use a soft slightly damp cloth with water and
wipe dry immediately.
Caution: Never use chemicals to clean the case, as they may cause
damage to the plastic and cause the alarm not to function.
Trouble shooting
The unit does not sound when the batteries are installed
Ensure that the batteries are connected correctly according to the
diagram in the battery compartment
The alarm does not arm
Ensure that the back plate of the alarm unit is secure to hold the batteries
in place and that the red light comes on when the keypad buttons are
pressed
The red light located in the middle of the alarm 4 is on
This is the low battery warning indicator light. The batteries need
replacing
Storing telephone Number
Press
and store 1st group of telephone No. and press
to
confirm storing. Press
for 2nd group of telephone No. and so on.
Maximum 3 sets of telephone number with max 16 digits can be stored.
Note: Only use friends and families telephone numbers. Do not use
emergency service numbers.
Can be used with a PABX phone system.
Recording a message
Press
the low battery indicator light will illuminate, you now have
6 seconds to record your personal message. Once the light goes off your
recording time is over.
Suggested message: This is an alarm call from?
Battery precautions
When using this product follow these precautions at all times.
· Use only the appropriate size batteries
· Be sure to follow the correct polarity when installing the batteries as
indicated in the battery compartment. Incorrect polarity may cause
damage to the alarm.
· Do not mix different types of battery such as Alkaline and Carbon-zinc
or old batteries with new.
· If the alarm is not used for long periods of time, remove the batteries to
prevent damage or injury from possible battery leakage.
· Do not recharge batteries not intended to be recharged as they can
overheat and rupture. (Always follow the manufacturer's directions.)
DECLARATION OF CONFORMITY
Company
Address, City
EDEN S.A.S
Centre de Puissanton
181 chemin de Puissanton
06220 VALLAURIS
France
Country
Declares that the product:
Description
Product number
Trade mark
KONFORMITATSERKL ARUNG
Firma
Land
EDEN S.A.S
Adresse Centre de Puissanton
181 chemin de Puissanton
06220 VALLAURIS
France
Erklärung des Produktes:
Mini alarm + PSTN dialler
M A89
EDEN
Artikelbeschreibung
Artikel-Nr.:
Markenname:
Minialarm mit Telefonwahlgerät
M A89
EDEN
Is herewith confirmed to comply with the requirements set in the
Council
Directive on the Approximation of the Member States relating to:
Hiermit bestätigen wir, um die Anforderungen aus den Richtlinien des
Rates über die Annäherung der Mitgliedsstaaten zu befolgen, die
Anerkennung folgender Richtlinien:
Electro Magnetic Compatibility Directive
R&TTE Directive
Elektromagnetische Verträglichkeit (EMC)
R&TTE-Anforderung
(89/336/EEC)
(1999/5/EEC)
(89/336/EEC)
(1999/5/EEC)
Assessment of compliance of the product with the requirements
relating to EMC was based on the following standards:
EN 301 489-1 V1.8.1 (2008-04)
EN 301 489-3 V1.4.1 (2002-08)
Die Bewertung des Produktes bezüglich der Anforderung bezüglich
EMC basiert auf den folgenden Standards:
EN 301 489-1 V1.8.1 (2008-04)
EN 301 489-3 V1.4.1 (2002-08)
The requirements relating RF was based on the following standard:
EN 300 220-2 V2.1.2 (2007-06)
Die Anforderungen bezüglich RF basiert auf den folgenden
Standards:
EN 300 220-2 V2.1.2 (2007-06)
The requirements relating to the telephone network compliance have
been checked per following standard
EN 301 437 V1.1.1 (TBR 37)
Die Anforderungen bezüglich Telefon Netzwerk basiert auf folgenden
Standard:
EN 301 437 V1.1.1 (TBR 37)
DECLARATION DE CONFORMITE
Société
Adresse/Ville
Pays
EDEN S.A.S
Centre de Puissanton
181 chemin de Puissanton
06220 VALLAURIS
France
Déclarons que le produit :
Description
Référence produit
Marque de commercialisation
Mini alarme + transmetteur
M A89
EDEN
Est certifié conforme aux exigences définies dans la Directive du
Conseil d’approximation des Etats Membres suivante :
Compatibilité Electro magnétique
Directive R&TTE
(89/336/EEC)
(1999/5/EEC)
L’évaluation de conformité du produit par rapport aux exigences de
Compatibilité Electro Magnétique a été effectuée sur la base des
normes suivantes :
EN 301 489-1 V1.8.1 (2008-04)
EN 301 489-3 V1.4.1 (2002-08)
Authorized representative: Mr. Pierre Van Der Deure
Les exigences radio ont été vérifiées par rapport à la norme suivante :
EN 300 220-2 V2.1.2 (2007-06)
Les exigences téléphoniques ont été vérifiées par rapport à la norme
suivante
EN 301 437 V1.1.1 (TBR 37)
Date: 07.09.2010
DECLARATION OF CONFORMITY IN OTHER LANGUAGES ON WWW.ELRO.EU