le programme final et les résumés
Transcription
le programme final et les résumés
Journée Thématique de la Société de Biomécanique « La biomécanique cardio cardio--vasculaire en pratique clinique: un mariage de raison(s) ? » organisée sous le parrainage de la Société Française d'Hypertension Artérielle Program and Abstract Book Patrick Segers Pierre Boutouyrie Nikos Stergiopulos 14 décembre 2007 Paris, Paris, Palais des Congrès, France Journée Thématique 14 décembre 2007 – Abstract Book 10:30-10:40 2 Opening Session 1: Advanced computer simulations of cardiovascular applications Chair: Patrick Segers and Emilie Marchandise 10:40-10:55 Benyebka BOU-SAID1,Kenneth JANSEN2,John TICHY2 Finite Element Simulation of Blood Flow in a Bifurcation with Non-Newtonian Effects 1 LaMCoS,INSA, 20 Av. A. Einstein 69 621 Villeurbanne Cedex; 2 Rensselaer Polytechnic Institute, Troy NY, USA 10:55-11:10 Ramiro MORENO1, Franck NICOUD2, Frédéric VIART3, Hervé ROUSSEAU1 Optimized Computational Functional Imaging for Arteries 1 I2MR, UMR 858 INSERM, CHU Rangueil, Toulouse; 2 I3M, CNRS UMR 5149, Université de Montpellier II; 3 ASA, Advanced Solutions Accelerator, Montpellier 11:10-11:25 Valérie LACROIX1, Marie WILLEMET2, Emilie MARCHANDISE2 A numerical hemodynamic tool for predictive vascular surgery 1 Cliniques Universitaires Saint Luc, Cardio-vascular Department, Av. Hippocrate, 10, 1200 Bruxelles, Belgium; 2 Université Catholique de Louvain, Department of Mechanical Engineering, Av. G. Lemaitre, 4, 1348 Louvain-La-Neuve, Belgium. 11:25-11:40 Peter MORTIER1, Matthieu DE BEULE1,2, Denis VAN LOO1, Pascal VERDONCK1, Benedict VERHEGGHE1,3 Numerical simulations and bifurcation stenting: a promising combination 1 IBiTech, Ghent University, Belgium; 2 LMO, Ghent University, Belgium; 3 Department of Mechanical Construction 11:40-11:55 Walid MILADI1, Jean Marie CROLET 2 Contribution à la simulation de l'écoulement sanguin dans des bifurcations 1 FEMTO-ST, Département LMARC; 2 Institut Supérieur d'Ingénieurs de Franche-Comté (I.S.I.F.C), Université de Franche Comté Journée Thématique 14 décembre 2007 – Abstract Book 3 Session 2: Various topics on biomedical engineering in cardiovascular applications Chair: Nikos Stergiopulos and Agnes Drochon 14:00-14:15 Nikos STERGIOPULOS Arterial wall mechanics accounting for wall constituents and structure Hemodynamics and Cardiovascular Technology Laboratory, Ecole Polytechnique Federale de Lausanne, Lausanne, Switzerland 14:15-14:30 M. MAASRANI1, J.-P. VERHOYE2, H. CORBINEAU2, A. DROCHON3 Un outil de simulation des flux après pontage dans le cas de coronaropathies sévères 1 IUL University, Department of Biomedical Engineering, Beirut, Lebanon; 2 CHU PontChaillou, Service de Chirurgie Cardiovasculaire, Rennes, France; 3 UTC, UMR CNRS 6600, Compiègne, France 14:30-14:45 Anne AMBLARD, Benyebka BOU-SAID Tribological study on endoprosthesis used for the treatment of abdominal aortic aneurysms LaMCoS, INSA, 20 Av. A. Einstein 69 621 Villeurbanne Cedex 14:45-15:00 Annemiek JM CORNELISSEN1, Thi-Hanh NGUYEN3, Mathieu UNBEKANDT2, Loïc LEROY2, Alia AL-KILANI2, Ferdinand LE NOBLE4 and Vincent FLEURY2 In-Tissue Stress Gradients Pave the Path for Blood Flow and Vascular Patterning 1 Laboratoire Matière et Systèmes Complexes, Université Paris 7 Denis Diderot, Paris, France; 2 Équipe de Biophysique, Université de Rennes 1, Rennes, France; 3 École Polytechnique, Paris, France; 4 Max Delbrück centrum für Molekulare Medizin, Berlin, Germany 15:00-15:15 Nicolas DISPOT 1, Patrice FLAUD1, Maurice ROSSI 2 Méthodes inverses atraumatiques en hémodynamique 1 Laboratoire Matière et Systèmes Complexes, Bâtiment Condorcet, 10 rue Alice Domon et Léonie Duquet, 75205 Paris cedex 13; 2 Institut Jean le Rond d'Alembert, UPMC UMR 7190, 4 place Jussieu, T55-65, 5ème étage, case 161-162, 75252 Paris cedex 05 15:15-15:30 Dima ABI ABDALLAH, Agnès DROCHON, Vincent ROBIN, Odette FOKAPU Écoulement du sang en présence d'un champ magnétique Université de Technologie de Compiègne Journée Thématique 14 décembre 2007 – Abstract Book 4 Session 3: Biomechanics and cardiovascular diagnostics Chair: Pierre Boutouyrie 15:45-16:00 Pierre BOUTOUYRIE, Ingrid MASSON, Hélène BEAUSSIER, Cédric COLLIN, Erwan BOZEC, Mustapha ZIDI, Stéphane LAURENT Inhomogeneities in arterial wall mechanics : a segmental approach and clinical applications Hôpital Européen Georges Pompidou, Paris, France 16:00-16-15 David TANNE1,2, Julien MAGNE2, Eric BERTRAND1, Philippe PIBAROT2, Régis RIEU1. Pulmonary hypertension following mitral valve replacement: reproducing in-vitro what the clinician has diagnosed. 1 Equipe Biomécanique Cardiovasculaire, IRPHE-UMR 6594, Université de la Méditéranneé, Marseille. 2 Quebec Heart Institute, Laval Hospital, Laval University, Sainte-Foy, Quebec, Canada. 16:15-16:30 Anthony MUTITI1, Paul KELLY2, Stephen GREENWALD2 Measurement of arterial pulse wave velocity by Doppler ultrasound and/or photoplethysmography 1 Department of Paediatrics, UNZA School of Medicine, Lusaka, Zambia; 2 Institute of Cell & Molecular Science, Barts & The London School of Medicine & Dentistry, Queen Mary, University of London 16:30-16:45 Jan G KIPS1,2, Ernst R RIETZSCHEL3, Marc L DE BUYZERE3, Thierry C GILLEBERT3, Luc M VAN BORTEL2, Patrick SEGERS1 Wave reflection assessment via flow wave approximation: triangular versus population-based waveform 1 Cardiovascular Mechanics and Biofluid Dynamics, IBiTech, Ghent University, Belgium; 2 Department of Pharmacology, Ghent University Hospital, Belgium; 3 Department of Cardiovascular Diseases, Ghent University Hospital, Belgium 16:45-17:00 Damien COISNE1, Nicolas BENARD2, Luc CHRISTIAENS 1, Nicolas Varoud VIAL1, Pascal BLOUIN1, Robert PERRAULT2, Sloven DUBOIS3, Michel MENARD3 ECHO-PIV. Une nouvelle méthode d'éstimation du champ de vitesse 2D par l'échographie. Description, validation expérimentale sur modèles de sténose vasculaire et flux intra ventriculaire gauche 1 Cardiologie CHU Poitiers; 2 LEA UMR CNRS 6609 Université de Poitiers, 3 I Université de La Rochelle. Journée Thématique 14 décembre 2007 – Abstract Book Session 1 10:40-12:10 Advanced computer simulation for cardiovascular applications Chair: Patrick Segers and Emilie Marchandise 5 Journée Thématique 14 décembre 2007 – Abstract Book 6 Finite Element Simulation of Blood Flow in a Bifurcation with Non-Newtonian Effects Benyebka BOU-SAID1,Kenneth JANSEN2,John TICHY2 1. LaMCoS,INSA, 20 Av. A. Einstein 69 621 Villeurbanne Cedex 2. Rensselaer Polytechnic Institute, Troy NY, USA In recent years the methods of computational fluid dynamics (CFD) have been applied to the cardiovascular system to better understand the relationship between arterial blood flow and wall shear stress patterns and the disease process. A long-range goal is for such numerical studies to play a direct role in patient-specific surgical planning. Prior to the surgery, anatomic and physiologic data would be obtained through imaging procedures. From this information, three-dimensional computer models of the geometry are determined. The finite element model for blood flow is then applied to this arterial vessel system. In particular, the surgical configuration can be optimized to avoid flow abnormalities (turbulence and recirculation) thought to cause clots and plaque deposits. One of (Jansen) is presently involved in such a project with Stanford University and the University of Texas-Austin in the US. Obviously, the technical challenges associated with such modeling are formidable. Among the many problems to be addressed are issues concerning adaptive anisotropic finite elements, fluid-solid coupling, turbulence, pulsatile variation of the cardiac cycle, outflow boundary conditions, etc. In the proposed paper, we add yet another complication – the non-Newtonian nature of blood flow. We consider two broad categories of non-Newtonian: generalized Newtonian (purely viscous), and time dependent (viscoelastic). The former refers to models for variation of viscosity with shear rate (the power-law model, Carreau-Yasuda model, etc.); however, the fluid stress only depends on the instantaneous rate of strain. The latter refers to fluids that have an inherent time property and a “memory” of the past strain. The Maxwell model and the Phan-Thien and Tanner (PTT) model are such viscoelastic models. Through measurement, blood viscosity is known to vary quite strongly over the range of shear across an arterial flow (by a factor of four or so). Although measurements of blood viscoelasticity are rare, due to the fact that blood is a suspension of deformable cells in aqueous plasma, based on polymer network theory, it is likely that blood is significantly viscoelastic. Thus it is reasonable to assume that non-Newtonian effects in blood flow – heretofore rarely studied - may have a significant effect on cardiac flow structures. Due to the preliminary nature of our study, we limit ourselves to a generic and idealized geometry – a simple standard bifurcation of a tube with rigid walls. The pulsatile nature of the flow is considered. We use the Carreau-Yasuda model to describe generalized Newtonian viscosity variation, and the PTT model to describe viscoelastic flow. Turbulence is considered by a two-equation Reynolds Averaged Navier-Stokes (RANS) model, and by the Direct Navier Stokes (DNS) approach. Modification of the existing Jansen CFD code is considerable for the PTT case. Six additional scalar stress transport equations must be solved alongside the three momentum equations. Our results are not yet available; however, the most interesting case may be when the turbulence time scales in DNS simulations interact with the viscoelastic time scales, producing effects not foreseen by turbulent Newtonian models. Journée Thématique 14 décembre 2007 – Abstract Book 7 Optimized Computational Functional Imaging for Arteries Ramiro MORENO1, Franck NICOUD2, Frédéric VIART3, Hervé ROUSSEAU1 (1) I2MR, UMR 858 INSERM, CHU Rangueil, Toulouse (2) I3M, CNRS UMR 5149, Université de Montpellier II (3) ASA, Advanced Solutions Accelerator, Montpellier Background A tremendous evolution of the vascular imaging is occurring during the last two decades, when the traditional 2D evaluation by the angiography has been challenged by the 3D views offered by the angio CT, MR and either three-dimensional angiography. Even though, so far there is not any imaging method which is routinely performed for a morphologic and functional study of the thoracic aorta and main arteries. Materials and Methods In this contribution we want to report the first clinical application of a new imaging method coupling dynamic MRI and Computational Fluid Dynamics (CFD) in the pre and postoperative evaluation of patients candidated and subjected to endovascular aortic repair (EVAR) of thoracic aorta. The originality of this work is focused on the way how the position of the wall is set in the discrete field. The hemodynamic simulations carried out up to now can hardly describe the behaviour for the arterial wall. We propose to choose a non-coupled, fluid / structure model, which will impose at each time step of the CFD code, the position of the wall based on the dynamic medical imaging; by this way we try to preserve the non-linear arterial rheology. A new MRI protocol is at the heart of the conditions imposed to the numerical calculations. Results The CFD models reliably reproduced the dynamic vascular anatomy compared with the native images, provided realistic 3D images based on different selected parameters (velocity, turbulence, wall shear stress) and seemed easily readable. The validation of this concept is averred through some in-vitro and in-vivo applications. A short clinical study (15 patients) enabled to realise the feasibility in the case of patients having an Aortic Stent-Graft control. Conclusions This technique proposes a new way of vascular imaging, founded on the routine evaluation of morphologic and functional findings. In particular in the thoracic aortic district this means a non-invasive technique for the analysis of the physiopathology of arterial disease and treatment results with the same image protocol routinely performed. Further experiences will test the practical implications that the multiple, functional results of this imaging techniques can suggest and, on the other side, the new eventual clinical application’s fields. The research project (OCFIA, ANR-07-CIS) intends to drive modern medicine towards a better knowledge of vascular pathologies and innovative technical means (HPC) to handle them. Journée Thématique 14 décembre 2007 – Abstract Book A numerical hemodynamic tool for predictive vascular surgery. Valérie LACROIX(1), Marie WILLEMET(2), Emilie MARCHANDISE(2) (1) Cliniques Universitaires Saint Luc, Cardio-vascular Department, Av. Hippocrate, 10, 1200 Bruxelles, Belgium (2) Université Catholique de Louvain, Department of Mechanical Engineering, Av. G. Lemaitre, 4, 1348 Louvain-La-Neuve, Belgium. Background Arteriosclerosis, the most common type of cardiovascular disease, gives rise to the thickening of the arteries and leads in the lower limbs to critical ischemia. When a long arterial segment is occluded, a bypass remains the only surgical treatment to relieve the symptoms. Bypass surgery planning is commonly based on morphological data provided from radiological exams and on clinical studies from the literature. However, no predictive hemodynamic tool is available to choose for the best surgical option in order to avoid long-term obstruction of bypasses. Materials and Methods We have considered a reduced one-dimensional model of the peripheral arterial network. We resolve the equations of conservation of mass and momentum and describe the arterial wall as a thin and elastic material. We assume that blood flow in reasonable large vessels can be modelled as an incompressible, laminar and Newtonian fluid with a constant density and constant viscosity. We base our model on patient’s specifications, enforcing boundary conditions at the inlet and outlet arteries of the leg. At the inlet, the velocity measured with the echoDoppler is prescribed. At the outlet, the resistance and compliance of the distal network are modelled with an electrical analog of an hydraulic system. These electrical parameters are based on preoperative (echoDoppler) and operative measurements (arterial pressure in the pathological network). Our system of equations is dicretized by a Runge-Kutta discontinuous Galerkin method, assuming conservation of mass and total pressure at the interfaces. Results We tested the model in a clinical case: a patient needed a femoro-popliteal bypass for a superficial femoral artery occlusion. Area, velocity and pressure measurements of the pathological network were taken as described above. We observed good agreement between the flow velocities predicted in the bypass graft with the numerical simulation and the observed clinical results. The model can also predict the flow velocity expected in the bypass depending on its characteristics of material, diameter and shape. Conclusions We present a new approach for vascular surgery planning. This one-dimensional discontinuous Galerkin method coupled with a zero-dimensional model can predict blood flow profile of distal bypasses based on non invasive echoDoppler measurement before surgery and on arterial pressure measured during the operation. The surgeon could choose for the best option because the long-term graft patency is closely related to its hemodynamic characteristics. 8 Journée Thématique 14 décembre 2007 – Abstract Book Numerical simulations and bifurcation stenting: a promising combination Peter MORTIER1, Matthieu DE BEULE1,2, Denis VAN LOO1, Pascal VERDONCK1, Benedict VERHEGGHE1,3 1 IBiTech, Ghent University, Belgium 2 LMO, Ghent University, Belgium 3 Department of Mechanical Construction and Production, Ghent University, Belgium Background Stenting bifurcation lesions is still a challenge in coronary intervention and is generally associated with a low success rate. Many different techniques have been proposed, but all the suggested methodologies have their specific limitations. Therefore, numerical simulations may help to understand and eliminate the shortcomings of current clinical techniques and devices. In this computational study, one of the current techniques is analyzed, which involves the implantation of a stent in the main branch and the subsequent inflation of an angioplasty balloon in the side branch. The stent material covering the side branch opening is pushed away by the balloon inflation. This results in improved flow conditions at the entrance of the side branch. Materials and Methods The finite element simulations were performed using the commercial code ABAQUS (Dassault Systèmes). The geometrical model consists of the CYPHER stent (nominal diameter 3mm, Cordis) and the trifolded RAPTOR (nominal diameter 2.5mm, Cordis) balloon. The main and side branch intersect at an angle of 45° and have a diameter of respectively 3 and 2.5 mm. The stent is expanded in the main branch during a first step. Subsequently, the trifolded balloon, located in both the side and main branch is inflated. Results The balloon inflation deforms and enlarges the stent cell in front of the side branch, as illustrated in the right panel of the figure. However, the results also show some stent struts that are not completely pushed against the vessel wall (indicated with an arrow). These parts of the stent will obstruct the blood flow towards the side branch and may induce thrombosis formation. Conclusions In this study, it is shown that advanced numerical models may provide useful insights in the mechanical behavior of complex stenting techniques. In the investigated case, the inflation of the balloon positioned through a stent cell partially removes the obstructing stent material. This model allows quantifying the impact of balloon size, compliance and pressure and this knowledge can then be used in clinical practice to improve the outcome of the current interventions. In future, similar computer models will be developed in order to investigate a number of other (in clinical practice) proposed techniques and to evaluate the performance of different stent designs. This may lead to improved procedures and/or devices to treat bifurcation lesions. 9 Journée Thématique 14 décembre 2007 – Abstract Book Contribution à la simulation de l’écoulement sanguin dans des bifurcations Miladi Walid 1, Crolet Jean Marie 2 1 FEMTO-ST, Département LMARC 2 Institut Supérieur d'Ingénieurs de Franche-Comté (I.S.I.F.C) Université de Franche Comté Introduction Notre étude est une contribution à la modélisation et à la simulation numérique de la circulation sanguine dans le système artériel de manière à réaliser, à terme, un outil d'investigation à usage biomédical. La modélisation repose sur un traitement de l'interaction fluide structure et une description structurelle des artères comme des tubes hétérogènes à propriétés élastiques variables. Nous abordons plusieurs phases dont l'écoulement lui-même et l'aspect numérique de l'interaction fluide structure. Méthode L'écoulement est naturellement régi par l'équation de Navier Stokes et, de manière classique, on modélise la pression à la sortie du ventricule gauche par une fonction périodique respectant les diverses phases du rythme cardiaque et les propriétés physiques des artères par des lois de comportement déjà publiées dans la littérature. Une des particularités de nos simulations réside dans le fait que la viscosité peut varier selon divers paramètres dont le diamètre du vaisseau sanguin. Il est clair que cet effet n'est donc intéressant qu'en présence de bifurcations. Résultats Le calage de notre modèle peut se faire au niveau de l'écoulement dans l'aorte. La simulation de différentes configurations est relativement aisée et rapide. Par ailleurs, nous avons pu constater que la dépendance de la viscosité par rapport au diamètre du canal joue un rôle non négligeable. Une expression explicite d'une telle relation est cependant délicate car plusieurs autres facteurs ne sont pas encore pris en compte, en particulier la déformation des cellules transportées par le sang. Remerciements Ce travail repose sur une collaboration entre le département de mécanique appliqué de l’institut FEMTO-ST (UMR CNRS 6174), le laboratoire de mathématique (UMR 6623) et le service d’exploitation fonctionnelle du CHU de Besançon (IFR 133). Ce travail a été financé par le gouvernement tunisien et français. 10 Journée Thématique 14 décembre 2007 – Abstract Book Session 2 14:00-15:30 Various Topics on Biomedical Engineering in Cardiovascular Applications Chair: Nikos Stergiopulos and Agnes Drochon 11 Journée Thématique 14 décembre 2007 – Abstract Book 12 Arterial wall mechanics accounting for wall constituents and structure N. Stergiopulos Ecole Polytechnique Fédérale de Lausanne (EPFL) Hemodynamics and Cardiovascular Technology Laboratory (LHTC) CH-1015 Lausanne Arterial wall function and remodeling depends on local wall stresses. Precise knowledge of stresses acting on each wall constituent and in all parts of the wall is still a very difficult task. This requires a constituent-based modeling and analysis of the arterial wall. The threedimensional biomechanical behavior of the vascular wall is best described by means of strain energy functions, which allow for the analysis of stresses over a wide range of deformations. We have earlier developed appropriate strain energy functions for the arterial wall [1]. The Zulliger et al. model uses a strain energy function, which accounts for the constituents and structural properties of the wall (i.e., collagen, elastin and vascular smooth muscle cell content as well as a statistical description for collagen engagement). The Zulliger et al. model was subsequently challenged by the work of Roy et al. [2], which showed that significant residual stresses are released when the arterial wall is decellularized, suggesting an in-series arrangement of the VSM with elastin. The in-series elastin would be in tension, whereas the inparallel elastin would be in compression. Upon VSM disruption, the in-series elastin cannot bear tension anymore and thus the compressed elastin expands relieving the additional residual strains [2]. Treatment with Cytochalassin D partially destroys stress fibers and disengages the VSM cytoskeleton, leading to further release of residual stresses and to a more compliant wall, all being consistent with the model of Roy et al. [2]. Keywords: wall constituents, collagen engagement, vascular smooth muscle mechanics 1. Zulliger MA, Fridez P, Hayashi K, and Stergiopulos N. A strain energy function for arteries accounting for wall composition and structure. J Biomech 37: 989-1000, 2004. 2. Roy S, Silacci P, and Stergiopulos N. Biomechanical properties of decellularized porcine common carotid arteries. Am J Physiol Heart Circ Physiol 289: H1567-1576, 2005. Journée Thématique 14 décembre 2007 – Abstract Book 13 UN OUTIL DE SIMULATION DES FLUX APRES PONTAGE DANS LE CAS DE CORONAROPATHIES SEVERES M. MAASRANI1, J.-P. VERHOYE2, H. CORBINEAU2, A. DROCHON3 IUL University, Department of Biomedical Engineering, Beirut, Lebanon, 2 CHU PontChaillou, Service de Chirurgie Cardiovasculaire, Rennes, France, 3 UTC, UMR CNRS 6600, Compiègne, France 1 Contexte La situation pathologique étudiée est celle où l’artère coronaire droite est thrombosée et où les deux artères coronaires gauches sont sténosées. Si le patient présente un réseau collatéral fonctionnel, le côté droit du cœur sera irrigué quand même via ce réseau de suppléance. Lors de l’intervention chirurgicale, 2 pontages sont réalisés sur les coronaires gauches. L’enjeu de l’étude est de pouvoir qualifier, avant l’intervention, l’efficacité du réseau collatéral pour juger de la pertinence d’un troisième pontage, sur la coronaire droite. Des problèmes de resténose peuvent en effet apparaître chez les patients ayant subi un triple pontage coronarien et présentant une bonne collatéralité. Matériel et méthodes Les mesures de pression et de débit sont effectuées par l’équipe chirurgicale de Rennes, pendant l’opération à cœur battant. Quatre situations sont successivement étudiées : 0G : situation pathologique, aucun pont ; 1G : un seul pont, sur l’artère droite ; 2G : deux ponts, du côté gauche (le pont droit est clampé) ; 3G : les 3 ponts sont en charge. Le modèle proposé pour la simulation de la répartition des flux dans le réseau coronaire est basé sur l’analogie entre les réseaux hydrauliques et électriques : les pertes de charge sont assimilées à des différences de potentiel, les débits à des courants. La viscosité et l’inertie du sang sont prises en compte par des résistances et des inductances, l’élasticité des artères par des capacités. Les simulations sont effectuées avec Simulink de Matlab. Résultats et discussion Le modèle permet de connaître des grandeurs qui ne sont pas directement accessibles à la mesure : les débits dans les branches collatérales (entre artères gauches et artère droite), dans les artères natives sténosées (avant et après pontage), dans les réseaux capillaires terminant chaque branche, ainsi que les pressions en différents points du réseau. Les résultats montrent que la mise en charge des ponts gauches n’améliore que faiblement l’irrigation du côté droit (via les collatérales) : en moyenne, pour les 7 patients inclus dans l’étude, le débit total (somme des débits reçus par les 3 branches, y compris ceux apportés par les ponts) augmente de 76.9 ±12.7 à 88.2 ±16.5 ml/min entre les situations 0G et 2G et de 109.3 ±20.6 à 119.2 ±22.2 ml/min entre les situations 1G et 3G. Ceci justifie donc la revascularisation complète effectuée chez ces patients. Pour améliorer la compréhension de l’hémodynamique de ce système, il sera nécessaire, entre autres, de prendre en compte l’influence de la contraction myocardique (entraînant une réduction de l’aire des vaisseaux) sur les éléments du réseau et d’y introduire les pertes de charge dues aux anastomoses. Journée Thématique 14 décembre 2007 – Abstract Book Tribological study on endoprosthesis used for the treatment of abdominal aortic aneurysms Anne AMBLARD, Benyebka BOU-SAID LaMCoS, INSA, 20 Av. A. Einstein 69 621 Villeurbanne Cedex Cardiovascular diseases are a major cause of death in the Western countries. The abdominal aortic aneurysm, characterized by a localized dilatation of the aorta, is a cardiovascular disease concerning 6 to 7% of the population. Such an aneurysm can burst, causing serious internal bleeding. Its prevention is thus a major issue from a medical point of view. A relatively new treatment of such an aneurysm is the endovascular repair: an endoprosthesis is positioned inside the aneurysm. Because there are smaller incisions, endovascular repair results in less discomfort, shorter hospital stay and faster recovery. It appears essential to direct research in this direction since the subject remains relatively poorly understood. However, as with any medical procedure, endovascular approach suffers from problems such as migration or endoleaks. The stresses generated by the blood flow are believed to be the major cause of these complications. A finite element model is proposed to understand these phenomena. Blood is a nonNewtonian fluid which cannot be represented by the traditional models. Hence, the Phan-Thien and Tanner model, derived from polymer rheology, is used to evaluate stresses generated on the prosthesis. Furthermore, the viscoelastic behaviour of the aorta is taken into account in our model. A separation between prosthesis and aorta is observed. One can give the best mechanical properties the endoprosthesis must have to avoid this separation. Fig1 : Dimensionless shear stress generated by blood, PTT model Fig 2. : Separation endoprosthesis/aorta 14 Journée Thématique 14 décembre 2007 – Abstract Book In-Tissue Stress Gradients Pave the Path for Blood Flow and Vascular Patterning Annemiek JM Cornelissen1 Thi-Hanh Nguyen3, Mathieu Unbekandt2, Loïc Leroy2, Alia Al-Kilani2, Ferdinand Le Noble4 and Vincent Fleury2 1 Laboratoire Matière et Systèmes Complexes, Université Paris 7 Denis Diderot, Paris, France ; 2Équipe de Biophysique, Université de Rennes 1, Rennes, France; 3 École Polytechnique, Paris, France; 4Max Delbrück centrum für Molekulare Medizin, Berlin, Germany By Newton’s law vascular development, and in more general tissue morphogenesis, requires mechanical forces to position cells and shape the developing organs. In a simplified picture, the addition of all incremental pushes of growing cells generates a stress gradient inside the growing tissue. Such stress gradient can on the one hand serve as a signal for cellular mechanotransducers resulting in gene activation. On the other hand, the dynamically changing landscape of stress guides the displacing, newly created, growing cells in an auto-organizing way. To address the auto-organizing role of stress gradients in vascular development we imaged the developing vasculature in the chick embryo yolk-sac in vivo. As soon as the vessels appeared, we measured the displacement of characteristic features in the vasculature. We show that the expansion speed inside the yolk-sac is higher at the edge than internally, with a linear variation of 0.016 h-1. Additionally, we isolated the yolk-sac from the yolk and mapped the compliance with a newly developed instrument: a scanning air puff tonometer. Compliance is a measure for in-plane stress. We observed a more than linear decrease in stress along the growth direction of the yolksac. A simple mathematical model is used to interpret the observations. The growth of the yolk-sac is modeled as a radial displacement of a viscous fluid between two fixed parallel plates, while fluid is injected uniformly into the yolk-sac. The injection represents the local additional flow due to cell dilation or mitosis. The model reveals that only uniform expansion of all cells in the yolk-sac can explain our observations. In conclusion, our observations suggest that the in-tissue stress gradients that correspond with softer regions at the edge of the yolk-sac is closely associated with the paths taken by the blood vessels. 15 Journée Thématique 14 décembre 2007 – Abstract Book Méthodes inverses atraumatiques en hémodynamique Nicolas DISPOT 1, Patrice FLAUD 1, Maurice ROSSI 2 1 : Laboratoire Matière et Systèmes Complexes, Bâtiment Condorcet, 10 rue Alice Domon et Léonie Duquet, 75205 Paris cedex 13 2 : Institut Jean le Rond d’Alembert, UPMC UMR 7190, 4 place Jussieu, T55-65, 5ème étage, case 161-162, 75252 Paris cedex 05 Introduction Le sang présente des caractéristiques rhéologiques extrêmement complexes : comportement non-newtonien, thixotropie… La mesure expérimentale des paramètres liés à la rhéologie du sang d’un individu constitue un bon indicateur de diagnostic. Nous proposons une méthode permettant à terme une mesure atraumatique et in vivo de certains de ces paramètres à partir de mesures de vélocimétrie Doppler. Méthode et dispositif expérimental Nous utilisons un banc hydrodynamique dans lequel s’écoule un fluide-modèle présentant des propriétés voisines de celles du sang dans la grande circulation, en terme de rhéologie et d’échogénicité aux ultrasons. La vélocimétrie ultrasonore à effet Doppler pulsé permet de mesurer les profils de vitesses dans la conduite. Nous utilisons ces données pour calculer la viscosité du fluide, ainsi que le rayon de la conduite. Le principe de la méthode repose sur la minimisation d’une fonction de coût dont les variables sont les paramètres rhéologiques du fluide, la vitesse du fluide au centre et les caractéristiques géométriques de la conduite. La minimisation fait appel à un algorithme de gradients conjugués où le gradient est calculé par une méthode de multiplicateurs de Lagrange. Le calcul des paramètres qui minimisent la fonction de coût constitue une mesure atraumatique. Résultats Nous avons principalement effectué des statistiques sur des écoulements simulés en tenant compte du bruit de mesure, des incertitudes sur le rayon de la conduite et sur la position de son centre, ainsi que des effets de convolution intrinsèque à la vélocimétrie Doppler. En outre, nous avons effectué une étude pour déterminer la gamme de fréquence permettant une caractérisation optimale des paramètres. Nous avons enfin comparé nos résultats sur des mesures in vitro, réalisées sur le banc hydrodynamique, à des mesures classiques de rhéométrie. Conclusions Nous avons donc mis au point une méthode numérique permettant une mesure nonperturbative des paramètres rhéologiques d’un fluide en écoulement pulsé dans une conduite cylindrique. La validité de la méthode numérique a été discutée et confirmée sur des écoulements simulés et appliquée à des écoulements in vitro. 16 Journée Thématique 14 décembre 2007 – Abstract Book Écoulement du sang en présence d’un champ magnétique Dima ABI ABDALLAH, Agnès DROCHON, Vincent ROBIN, Odette FOKAPU Université de Technologie de Compiègne Background L’effet d’un champ magnétique statique sur l’écoulement du sang a suscité beaucoup d’intérêt ces dernières années, notamment, avec l’augmentation des expositions à des champs de fortes intensités à cause de l’utilisation rependue de l’IRM. Quand le corps est soumis à un champ magnétique, les particules chargées du sang en mouvement perpendiculairement au champ sont déviées par la force de Lorentz, induisant ainsi des courants et des potentiels électriques. Ces potentiels perturbent le signal ECG qui sert à la synchronisation des images IRM. Par ailleurs, les interactions entre les inductions et le champ externe peuvent engendrer une réduction du flux et par suite provoquer une augmentation compensatrice de la pression artérielle afin de maintenir un débit sanguin constant. Materials and Methods L’écoulement magnétohydrodynamique du sang a fait l’objet de plusieurs études. Dans ce travail nous passons en revue les différentes approches pour calculer l’écoulement du sang en présence de champ magnétique statique. Les premiers calculs théoriques remontent aux débuts des années soixante. La solution la plus complète pour le cas stationnaire dans un vaisseau rigide à paroi isolante fut proposée par Gold. Vardanyan a publié, par la suite, une solution stationnaire approximative en négligeant les champs induits. Avec les mêmes hypothèses que Vardanyan, Sud et al. ont ensuite considéré un gradient de pression sinusoïdal, s'approchant ainsi de la nature pulsée de l'écoulement dans les artères. L'hypothèse des parois conductrices n'a été introduite qu'avec Kinouchi et al., qui ont inclus les inductions dans le vaisseau et les tissus environnants dans le cas d'un écoulement stationnaire. La majorité des études ont porté sur des tubes rigides. L’équipe de Sud et al. était l’une des rares à considérer l’élasticité du vaisseau. Toujours dans l'hypothèse de champs induits négligeables, ils ont étudié l’écoulement sinusoïdal dans un tube déformable. Results Les solutions proposées par ces différentes équipes ont été développées et comparées. Appliquer un champ magnétique statique externe à un écoulement sanguin provoque une réduction de débit, ainsi qu'un aplatissement du profil de vitesse avec un étirement plus prononcé selon la direction du champ appliqué. Les effets sont d'autant plus importants que le champ est grand. Une solution approximative obtenue en négligeant les inductions fait abstraction de la dissymétrie et surestime la réduction de vitesse. La comparaison de la solution exacte avec le cas stationnaire où la paroi est considérée conductrice, a montré que l'hypothèse de paroi isolante engendre une surestimation des débits. Conclusions La comparaison des résultats des approches sous différentes hypothèses permet de conclure que, dans la gamme de fonctionnement en IRM, il est raisonnable d’adopter des calculs simplifiés en négligeant les champs induits et la conductivité de la paroi. 17 Journée Thématique 14 décembre 2007 – Abstract Book Session 3 15:45-17:00 Biomechanics and Cardiovascular Diagnostics Chair: Pierre Boutouyrie 18 Journée Thématique 14 décembre 2007 – Abstract Book 19 Inhomogeneities in arterial wall mechanics : a segmental approach and clinical applications. Pierre BOUTOUYRIE, Ingrid MASSON, Hélène BEAUSSIER, Cédric COLLIN, Erwan BOZEC, Mustapha ZIDI , Stéphane LAURENT Unité de Pharmacologie Clinique, INSERM URMS 872, Hôpital Européen Georges Pompidou, 20 rue Leblanc, 75015 Paris Introduction : Les parois des gros vaisseaux sont le plus souvent considérées comme des milieux homogènes, isotropes, pourtant, la présence de plaques d’athérome rompt l’homogénéité spatiale de la paroi, et l’existence de maladies dissecantes suggère la présence de zones de fragilité dans l’épaisseur de la paroi artérielle. La rupture de plaque met en jeu des contraintes d’étirement dans le sens longitudinal. Deux types fonctionnels ont été déterminés (Paini et al. Stroke 2007) : le type A (paroi avec plaque plus distensible que la paroi adjacente) et le type B (paroi avec plaque plus rigide). Les patients dyslipidémiques et diabétiques de type 2 sont plus souvent de type B. La maladie d’Ehlers Danlos vasculaire se complique de dissections artérielles. Les mécanismes en sont mal connus. Une analyse de mécanique est possible, grâce aux mesures non-invasives de diamètre, épaisseur intima-media et rigidité artérielle par les systèmes échotracking de haute résolution. Objectifs : (a) Déterminer l’influence de l’hypertension essentielle sur les types fonctionnels A et B. (b) Réaliser une analyse biomécanique « couche par couche » en segmentant l’épaisseur de la paroi artérielle, pour mettre en évidence des différences comportementales d’une couche à l’autre. Méthodes : 92 patients, tous porteurs d’une plaque sur l’ACC, ont été inclus : 66 hypertendus essentiels (HT), traités ou non, et 26 normotendus (NT), 46 patients atteints du Syndrome Ehlers-Danlos de type vasculaire (vEDS) et 72 contrôles. Une nouvelle technique d’echotracking (Artlab®) nous a permis de mesurer l’épaisseur intima-media, le diamètre et la distensibilité sur 128 sites adjacents d’un segment d’ACC de 4 cm de long, aisi que les gradients de déformation au sein de l’épaisseur artérielle (Walltrack system). Résultats : Les HT et les NT ne diffèrent que par leur PA et leur âge. Les patients vEDS et leurs contrôles sont comparables pour l’age et la pression. Le type A, moins fréquent chez les HT que chez les NT, est associé à un remodelage interne alors que le type B est associé à un remodelage externe (diamètre externe augmenté mais diamètre interne inchangé). En analyse multivariée par régression logistique, les déterminants du type B sont l’HT (OR=6.8[1.35-34.9], P<0.02), le remodelage externe (OR=4.6[1.6-13.4], P<0.005) et l’absence de traitement par des inhibiteurs du SRA (OR=4.7[1.120.4],P<0.05). Différents outils conceptuels et opérationnels ont été développés. Aussi bien les patients vEDS que les sujets contrôles présentent une zone de déformation excessive à l’intérieur de la paroi (chiffres donnés à la fin de la phrase suivante). Cette zone est plus proche de la lumière (238±74µm (vEDS) vs 312±98µm (contrôles), p<0.001) et plus atténuée chez les patients vEDS que chez les sujets contrôles (pic médian : 52% vs 127%, p<0.001). Conclusion : Les patients hypertendus essentiels ont une paroi carotidienne plus rigide au niveau de la plaque d’athérosclérose, aboutissant à une exagération de la contrainte de courbure interne. Les bloqueurs du SRA pourraient diminuer cette contrainte longitudinale. Il est possible de réaliser une analyse segmentée en profondeur du comportement mécanique d’un segment artériel. Les parois artérielles, apparemment homogènes, présentent en fait des interfaces comportementales ; les déformations entre les différentes sous-couches de l’épaisseur de la paroi sont accrues dans ces zones. Ces déformations excessives pourraient jouer un rôle dans la survenue des dissections artérielles chez les vEDS. Les parois artérielles apparaissent beaucoup moins homogènes que décrit précédemment. L’influence de telles inhomogénéités sur les modèles biomécaniques de la paroi restent à étudier. Journée Thématique 14 décembre 2007 – Abstract Book Pulmonary hypertension following mitral valve replacement: reproducing in-vitro what the clinician has diagnosed. David TANNE1,2, Julien MAGNE2, Eric BERTRAND1, Philippe PIBAROT2, Régis RIEU1. 1 Equipe Biomécanique Cardiovasculaire, IRPHE-UMR 6594, Université de la Méditéranneé, Marseille. 2 Quebec Heart Institute, Laval Hospital, Laval University, Sainte-Foy, Quebec, Canada. Contexte : Les pathologies valvulaires mitrales entraînent une hypertension artérielle pulmonaire suite à l’augmentation progressive du gradient de pression trans-valvulaire qui se répercute sur la pression de l‘oreillette gauche puis sur la circulation pulmonaire. L’objectif du remplacement valvulaire mitral (RVM) est alors non seulement de rétablir une hémodynamie correcte de la valve mais aussi de diminuer la pression artérielle pulmonaire (Pap). Malheureusement, la normalisation de la Pap est souvent incomplète et fluctue d’un patient à l’autre. Le but de notre projet est donc de déterminer les facteurs patient et/ou prothèse dépendant qui influent sur la Pap suite au RVM, en particulier l’effet d’une disproportion patient-prothèse. Conjointement à une étude clinique (1,2), nous avons donc développé un simulateur du cœur gauche et de la circulation pulmonaire couplé à des modèles 0D (3). Méthodes : Les contractions et relaxations du ventricule et de l’oreillette sont induits par l’activation rigide de moules en silicone de forme anatomique issus d’une reconstruction d’images de coro-scanner. Deux pompes contrôlent le volume de chaque cavité, calculé par l’intégration temporelle du débit d’activation. Les signaux de commande définis par l’utilisateur respectent la loi de conservation de masse (débits entrant=débits sortant). Le réseau pulmonaire est simulé par un filtre en pi composé de 2 compliances et une résistance. La performance hémodynamique (aire valvulaire effective (AVE), gradient, régurgitation,…) des prothèses est obtenue par cathétérisme, débitmétrie et échographie doppler. Résultats : La synchronisation des 2 pompes d’activation permet de reproduire des formes physiologiques de pressions ventriculaire et auriculaire. Les impédances d’entrée aortique et pulmonaire sont conformes aux données publiées dans la littérature. Les courbes pression-volume obtenues simulent fidèlement des mesures invivo. Conclusions : Le simulateur permet de caractériser dans des conditions physiologiques et pathologiques la performance des prothèses mitrales et d’obtenir les EOA de référence, utiles dans la prévention de la disproportion patient-prothèse en préopératoire et de ses conséquences pulmonaires post-opératoires. En effet, la disproportion est associée à un persistance de l’HTAP (1,2) et à une mortalité accrue (facteur de risque : 3.1) lorsqu’elle est sévère (2). Les seuils définissant la sévérité (modéré : AVE indexée<1.2 cm²/m² et sévère : AVE indexée<0.9 cm²/m²) ont été confirmé en utilisant un modèle 0D (3). A terme, d’autres facteurs tels que la forme du débit mitral ou la présence/absence de l’appendice auriculaire gauche seront étudiés. 1 - Li,M.; Dumesnil,J.G.; Mathieu,P.; Pibarot,P. Impact of valve prosthesis-patient mismatch on pulmonary arterial pressure after mitral valve replacement. J.Am.Coll.Cardiol. 47(5):1034-1040;(2005). 2 - Magne,J.; Mathieu,P.; Dumesnil,J.G.; Tanné,D.; Dagenais,F.; Doyle,D.; Pibarot,P. Impact of prosthesis-patient mismatch on survival after mitral valve replacement. Circulation 115:1417-1425 (2007). 3 - Tanné,D.; Kadem,L.; Rieu,R.; Pibarot,P. Hemodynamic impact of mitral prosthesis-patient mismatch : an in-silico study. Soumis à Ann. Biomed. Eng. (2007). 20 Journée Thématique 14 décembre 2007 – Abstract Book Measurement of arterial pulsewave velocity by Doppler ultrasound and/or photoplethysmography Anthony MUTITI1, Paul KELLY2, Stephen GREENWALD2 1 Department of Paediatrics, UNZA School of Medicine, Lusaka, Zambia 2 Institute of Cell & Molecular Science, Barts & The London School of Medicine & Dentistry, Queen Mary, University of London [email protected] Background It is well known that arterial stiffness may be estimated from pulse wave velocity (PWV) measurements by detecting the pulse non invasively at two sites a known distance apart and timing its passage between them. The favoured method of pulse detection in early non invasive studies was Doppler ultrasound (for the flow pulse) although many more recent studies have relied on tonometry, which detects the pressure pulse and, latterly, photoplethysmography (PPG), which detects the volume/diameter pulse. PPG devices have employed a variety of custom built probes and, for finger and toe use, commercially available transmission pulse oximetry sensors. PPG and tonometric probes have high sensitivity when compared to the Doppler approach but are limited to detecting signals from superficial sites. As a means of exploiting the ability of Doppler to detect signals from the thoracic aorta and thus obtain direct estimates of aortic PWV; whilst retaining the advantages of PPG for more distal sites, we have modified our current PPG system (1) to accept output from a commercial hand-held Doppler velocimeter and/or the original PPG sensors. We report here firstly, a comparison between transit times obtained by these two methods of pulse detection and secondly, the results of recent PWV measurements (using PPG only) on African children of varied nutritional status. Materials and Methods (a) PPG and Doppler signals were recorded simultaneously, first at the wrist over the radial artery and then over the dorsalis pedis artery at the ankle, in 10 healthy volunteers aged 22 to 61 yr. (b) Blood pressure in the brachial artery and PWV, in the carotid-femoral, carotid-radial and femoro-popliteal arterial pathways were measured in 135 Zambian children, aged 4 to 8yr, classified into 4 groups on the basis of birth weight, (BW) and current weight, (CW). Group I (LL) comprised children of low BW and CW; group 2 (LN), of low BW and normal CW; group 3 (NL) had a normal BW and low CW and group 4 (NN) had both normal BW and normal CW. Results (a) Although, as expected the shape of the flow and diameter waves arriving at the wrist and ankle were different, their arrival time differed by less than 4 ms. In the measurements on Zambian children, there was no correlation between systolic or diastolic blood pressure and BW or CW. However, increased PWV in the leg was associated with low BW in both the LL group (low birth and current weight) and the LN group (;ow birth and normal current weight), (p < 0.05, ANOVA). Multivariate analysis for all groups combined, taking age, sex, blood pressure, weight and BW as independent variates, revealed a correlation between PWV and BW (p < 0.01) and a weaker but significant correlation with systolic blood pressure (p < 0.05). There were no gender differences and no association between PWV and CW. Conclusions To measure PWV from the foot of the systolic wave, Doppler and PWV pulse sensors may be used interchangeably. The preliminary results from the Zambian study show that low BW and impaired nutrition in early life are associated with increased leg conduit artery PWV in children and support the hypothesis that impaired growth in utero results in stiffer than normal arteries, which may then lead to raised pulse pressure in later life. Reference (1) Loukogeorgakis S et al. Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method. Physiol Meas 2002;23(3):581-96. 21 Journée Thématique 14 décembre 2007 – Abstract Book 22 Wave reflection assessment via flow wave approximation: triangular versus population-based waveform Jan G KIPS1,2, Ernst R RIETZSCHEL3, Marc L DE BUYZERE3, Thierry C GILLEBERT3, Luc M VAN BORTEL2, Patrick SEGERS1 1 Cardiovascular Mechanics and Biofluid Dynamics, IBiTech, Ghent University, Belgium 2 Department of Pharmacology, Ghent University Hospital, Belgium 3 Department of Cardiovascular Diseases, Ghent University Hospital, Belgium Background Wave reflections affect the aortic pressure and flow wave and play a role in systolic hypertension. Accurate quantification of pressure wave reflection requires separation of pressure in its forward (Pf) and backward (Pb) components, which requires aortic flow measurement. This limitation can be overcome by replacing the unknown flow wave by a triangular estimate of arbitrary amplitude, as recently proposed by Westerhof et al. We verified this technique using pressure and flow data measured in the Asklepios study (>2500 participants, 35 to 55 years). Secondly, we explored the possibility of approximating the flow wave by using a person-specific time-scaled normalised average flow waveform. Materials and Methods Wave separation analysis using measured pressure and flow yielded the reference reflection magnitude (RM=Pb/Pf). Then, RM was estimated using three triangular approximations of the flow wave, each with duration equal to the ejection time but with peak at (i) 30% of the ejection time (∆30); (ii) the shoulder point of the pressure wave (∆P) and (iii) the moment of real peak flow (∆Q). In a second analysis, an averaged and normalised flow waveform was calculated. This waveform was stretched in time based on timing of flow onset and end, derived from (i) the pressure wave (∩P) or (ii) the flow wave (∩Q) to obtain a subject-specific approximation of the flow waveform. ∆Q and ∩Q are considered reference cases. Results Averaged flow wave approximations correspond with lower absolute errors and yield better agreement between measured and estimated RM. This trend can also be seen in Bland-Altman plots of reference cases ∆Q (left panel) and ∩Q (right panel): m m mean + 2SD RM -RM Q∩ RM -RM Q∆ mean - 2SD m ∆ (RM Q+RM )/2 mean + 2SD mean - 2SD m ∩ (RM Q+RM )/2 Conclusions Application of the triangular flow approximation principle as proposed by Westerhof et al. on a large, non-invasive database of apparently-healthy middle-aged subjects showed rather low agreement between approximated and actual RM. Averaged waveform approximation yields significantly better agreement.This seems to imply that the triangular shape may be a too simple waveform approximation in this population. Journée Thématique 14 décembre 2007 – Abstract Book ECHO-PIV. Une nouvelle méthode d’éstimation du champ de vitesse 2D par l’échographie. Description, validation expérimentale sur modèles de sténose vasculaire et flux intra ventriculaire gauche. Damien Coisne MD PhD*, Nicolas Benard PhD**, Luc ChristiaensMD *, Nicolas Varoud Vial MD*, Pascal Blouin *, Perrault Robert**, Sloven Dubois***, Menard Michel*** * Cardiologie CHU Poitiers , ** LEA UMR CNRS 6609 Université de Poitiers, *** L3 I Université de La Rochelle. Background L’estimation des vitesses d’écoulement intra cavitaires est habituellement réalisée en clinique par la méthode Doppler (pulsé ou Doppler couleur). Cette méthode ne prends en compte que la composante de vitesse parallèle à la propagation des ultrasons. Le suivi des particules écho réfringentes est une approche prometteuse dans l’estimation des champs de vitesse complexes retrouvés usuellement en pathologie cardiaque et en particulier valvulaire. Notre objectif a été : de valider l’estimation de champs de vitesses par l’EchoPIV en confrontant les résultats à ceux fournis par la méthode de référence qu’est la PIV (particular velocity imaging). Deux méthodes de calculs ont été testées : la corrélation (AC) et le filtrage inverse (Filtres de Wiener ,WFM). Suite à cette validation expérimentale , une simulation expérimentale d’écoulements intra ventriculaires avec calcul du champs de vecteurs par l’ECHOPIV a été réalisée. Materials and Methods Des images de contraste d'écho de haute qualité ont été obtenues en modèle hydraulique simulant l'écoulement laminaire artériel en conditions pulsatiles (volume systolique: 26 ml, gamme de vitesse de 0 à 20 cm/s. La figure 1 montre les résultants obtenus par les trois méthodes (AC, WFM, et PIV. Les méthodes CCM et WFM détectent l'écoulement laminaire et les zones de re circulation. en donnant une représentation exacte du champ 2D de vitesse. Figure2 : résultat obtenus sur l’écoulement intra ventriculaire expérimental Results Figure 1 Figure 2 Conclusions Cette étude préliminaire démontre que le filtrage inverse donne des résultats prometteurs. Elle caractérise fiablement l’allure générale de l’écoulement, donne des résultants justes. Son application dans l’étude des écoulements cardiaques en particulier intra ventriculaires a eté réalisée démontrant une bonne visualisation des vortex générés par le flux trans mitral. 23