Sheet D Imperial Working Drawing Template
Transcription
Sheet D Imperial Working Drawing Template
Line of concrete slab Perimeter bulkhead Line of concrete slab. 64mm metal stud application at 305mm o/c. Wire suspension Clerestory c./w 6mm tempered glass Metal "C" channel INFRASTRUCTURE SERVICES & COMMUNITY SUSTAINABILITY / SERVICES D'INFRASTRUCTURE ET VIABILITÉ DES COLLECTIVITÉS INFRASTRUCTURE SERVICES BRANCH / DIRECTION D'INFRASTRUCTURE DESIGN AND CONSTRUCTION DIVISION / DIVISION DE LA CONCEPTION ET DE LA CONSTRUCTION Recessed downlight fixture. DEPUTY CITY MANAGER / DIRECTEUR DES SERVICES MUNICIPAUX DIRECTOR / DIRECTEUR MANAGER / GESTIONNAIRE FOR / POUR 22mm furring channel at 304mm o.c. Maple frame Glass insert c/w 6mm tempered glass and window film. Refer to window film legend. Sidelight c/w 6mm tempered glass and window film. Refer to window film legend. Type 2 partition. Refer to page ID06. Align window film stripes/ design 13mm gypsum board on metal suspension. Paint P4. Refer to Wall Finish Plan on page ID04. INFRASTRUCTURE SERVICES & COMMUNITY SUSTAINABILITY Gypsum tape Existing partition. 64mm steel stud Section - Drywall Ceiling 3 1:5 ID10 U/S of suspended 13mm GWB bulkhead. INFRASTRUCTURE SERVICES DESIGN & CONSTRUCTION - BUILDINGS New or existing partition Section - Drywall Bulkhead 4 1:5 ID10 211-2141 Thurston Drive Ottawa ON K1G 6C9 Rubber base typical T 613-739-3699 F 613-739-3965 LWG-ai.com [email protected] Mounting bracket by contractor Elevation - Training Room 1 1:20 ID10 Ceiling tile Rough-in to suit projection screen unit by contractor. Unit by Others. 991 Existing wood railing and spindles to be removed and discarded. 6 New 13mm drywall bulkhead to be painted P1 Section - Projection Screen 5 1:5 ID10 5 4 Issued for tender 28-08-2013 MB 3 Issued for Final client review 13-08-2013 MB 2 Issued for 90% client review 23-07-2013 MB 1 Issued for 60% client review 26-06-2013 MB NUMBER/ NUMÉRO MILESTONE / FAIT SAILLANT DATE: DG (Y/M/D) (A/M/J) INITIALS INITIALES DG MB SCALE DETAIL NUMBER 914 Existing drywall panel to be removed for new steel beams Existing GWB bulkhead to remain. Existing GWB ceiling to remain. 76 Miles LED strip light c/w aluminum channel. Fasten to side of bulkhead. Refer to spec on page ID03. 22 O.C. 381 Existing steel beam that runs parallel to suite entry to be removed and discarded 101 New 13mm GWB bulkhead. 1 DRAWING TITLE A1.1 SCALE: SHEET NUMBER THIS DRAWING IS THE PROPERTY OF THE CITY OF OTTAWA AND ALL COPYRIGHT IS RESERVED. DIMENSIONS ON DRAWING ARE FOR ESTIMATING PURPOSES ONLY. IT IS THE RESPONSIBLITY OF EACH CONTRACTOR AND SUB-CONTRACTOR OR CONSULTANT TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE. NOTIFY OWNER OF ANY ERRORS OR OMISSIONS PROIR TO COMMENCING THE WORK. DO NOT SCALE THE DRAWINGS. ARCHITECT / ARCHITECTE CONSULTANT / EXPERT-CONSEIL RID 4280 A Section - Drywall Bulkhead 6 1:2 ID10 O Existing plexi-glass connected to drywall ceiling to be removed and discarded CE DESSIN CONSTITUE LA PROPRIÉTÉ DE LA VILLE D'OTTAWA ET TOUT DROIT D'AUTEUR EST RÉSERVÉ. LES DIMENSIONS UTILISÉES LE SONT À DES FINS D'ESTIMATION SEULEMENT. IL INCOMBE À CHAQUE ENTREPRENEUR, SOUS-CONTRACTANT OU CONSULTANT DE VÉRIFIER TOUTES LES DIMENSIONS ET LES CONDITIONS SUR LE CHANTIER. VEUILLEZ INFORMER LE PROPRIÉTAIRE DE TOUTE ERREUR OU OMISSION AVANT D'ENTAMER LES TRAVAUX. NE DRESSEZ PAS LES PLANS À L'ÉCHELLE. CONSULTANT / EXPERT-CONSEIL CONSULTANT / EXPERT-CONSEIL 2985 Existing steel beam located behind wall finish to remain PROJECT / LOCATION / PROJET / ENDROIT Services Building Renovation Phase 2 1 River St. 2nd Floor OTTAWA, ONTARIO DRAWING / DESSIN Section - Existing Structural 2 Beam 1:20 ID10 Building Details FACILITY NO. / NO. DE INSTALLTIONS TBC PROJECT NO. / PROJET NO. 11080SPTI3 SHEET NO. / FEUILLE No. ID10