3500-U4x
Transcription
3500-U4x
Electronic Locking & Monitoring 3500-U4x db ID Box In Verbindung mit dem db Kommunikationsmodul 3500-U15 bietet diese Einheit die Möglichkeit zur Authentifizierung am Ende einer Schrankreihe. Über die Tastatur wird die gewünschte Schranktür ausgewählt. Anschließend können, je nach Ausstattung der ID Box, bis zu drei Berechtigungen (Fingerprint, PIN Code, Zutrittskarte) zur Authentifizierung eingegeben werden. Technische Änderungen vorbehalten. db ID Box In combination with the db Communications Module 3500-U15 this unit allows to authenticate at the end of a line of cabinets. The required cabinet door is selected via keypad. Depending on the configuration of the device, up to three credentials (fingerprint, pin code, access card) can be entered for authentication. Subject to technical changes. Power supply: Display: Keypad: via db bus cable (RJ45 patch cable) 2 lines, 16 digits each 12 keys metallic keypad Fig. 1 db ID Box front section Dimensions: 192 x 122 x 56 mm (W x H X D) Oper. temperature: 0 … 70 °C RFID (option): 125 kHz Prox or 13.56 Iclass reader Fig. 2 db ID Box rear section Mounting db ID Box Locate a suitable mounting surface for the db ID Box unit which is typically on the end of a row of cabinets. A person using the db ID Box should be able to stand directly in front of the unit without obstruction. Use the enclosed mounting template to mark the location for the mounting and cable pass-through holes and drill the cabinet where the 4 mounting screws are to be fixed. It is important to record the serial number (sticker below keypad) and location of each db ID Box installed for latter identification in the software db Control Cockpit. There is no limit to the number of db ID Boxes units that can be installed on a db Bus system, as long as: db ID Boxes 3500-U4x + db Communication Modules 3500-U20 <= 32) Mount the back plate of the db ID Box unit to the cabinet using the supplied mounting hardware. ID Box attaches directly to the db Bus. Pass the db Bus cables from the inside of the cabinet, through the cable passthrough hole. EMKA Beschlagteile GmbH & Co. KG Rev. 2014-07-24 / Roh-Art. Nr. 2577 Page 1 of 2 Electronic Locking & Monitoring 3500-U4x Wiring db ID Box to the db Bus System Connect the db Bus cables to the RJ-45 sockets and route the cables as shown in Fig. 3. Insert the 4 mounting lugs on the front section of the db ID Box unit into the 4 mounting holes on back section. Secure the db ID Box unit with the 4 supplied screws. The configuration of the db ID Box unit is done via db Control Cockpit Software Fig. 3 db ID Box- Bus cable connection and routing Fig. 4 db ID Box in db Bus System EMKA Beschlagteile GmbH & Co. KG Rev. 2014-07-24 / Roh-Art. Nr. 2577 Page 2 of 2