P o we rdummy lo ads 5 kW Oil cooled with digital
Transcription
P o we rdummy lo ads 5 kW Oil cooled with digital
Calorimeter accuracy Remote interfaces ±3% of reading within 5°C to 30°C ambient temperature range Serial RS232 on load’s front panel with user software interface. Mbus link (50m max) with optionnal Mbus/RS232 converter**. ED IFI Power in kW 5 4.5 Power dummy loads 50 Ω ± 5% DC – 1 GHz (on request DC - 2.5 GHz) ≤ 1.10 at 1GHz -25 to +55°C 5 kW Oil + forced air Thermal + oil circulation Lated fuses : Fan 2 A, Pump 0.8 A 47 kg RT S Impedance Frequency Max VSWR Temperature range Average power @ 45°C Cooling Safety loop Main power safety Weight oH CE Standards NF C 96-315 MIL-DTL-39030 R 5 kW Oil cooled with digital calorimeter 5 45 50 55 Ambient temperature in °C A I R 40 600 40 407 I AC power supply connector RS232 connector A Mbus link Safety loop interface 600 345 A I R A I R 260 21 2 M6 fixing holes on front and rear side Dimensions in mm P/N Connector* AC power supply* A 17-0519 EIA 1.5/8’’ 220 V - 50 Hz 70 17-0518 EIA 3.1/8’’ 220 V - 50 Hz 90 * Others models on request. Options . VSWR ≤ 1.05 470 to 860 MHz for digital applications . Swivel castors ** Possibility to connect 3 loads on Mbus/RS232 converter for power monitoring. Other Mbus/RS232 converters available on request for connecting up to 20 loads Instruction manual and wiring diagram available on request 1 2 ave n u e d e s C u r e s Z . I . - 9 5 5 8 0 A n d i l l y - F R A N C E Tel. +33 (0)1 34 16 33 00 - Fax +33 (0)1 39 59 85 20 - www.diconex.fr Edition 6.1 217