P o we rdummy lo ads 5 kW Oil cooled with digital

Transcription

P o we rdummy lo ads 5 kW Oil cooled with digital
Calorimeter accuracy
Remote interfaces
±3% of reading within 5°C to 30°C ambient temperature range
Serial RS232 on load’s front panel with user software interface.
Mbus link (50m max) with optionnal Mbus/RS232 converter**.
ED
IFI
Power in kW
5
4.5
Power dummy loads
50 Ω ± 5%
DC – 1 GHz (on request DC - 2.5 GHz)
≤ 1.10 at 1GHz
-25 to +55°C
5 kW
Oil + forced air
Thermal + oil circulation
Lated fuses : Fan 2 A, Pump 0.8 A
47 kg
RT
S
Impedance
Frequency
Max VSWR
Temperature range
Average power @ 45°C
Cooling
Safety loop
Main power safety
Weight
oH
CE
Standards
NF C 96-315
MIL-DTL-39030
R
5 kW Oil cooled with digital calorimeter
5
45 50 55
Ambient temperature in °C
A
I
R
40
600
40
407
I
AC power supply connector
RS232 connector
A
Mbus link
Safety loop interface
600
345
A I R
A I R
260
21
2 M6 fixing holes
on front and rear side
Dimensions in mm
P/N
Connector*
AC power supply*
A
17-0519
EIA 1.5/8’’
220 V - 50 Hz
70
17-0518
EIA 3.1/8’’
220 V - 50 Hz
90
* Others models on request.
Options
. VSWR ≤ 1.05 470 to 860 MHz for digital applications
. Swivel castors
** Possibility to connect 3 loads on Mbus/RS232 converter for power monitoring.
Other Mbus/RS232 converters available on request for connecting up to 20 loads
Instruction manual and wiring diagram available on request
1 2 ave n u e d e s C u r e s Z . I . - 9 5 5 8 0 A n d i l l y - F R A N C E
Tel. +33 (0)1 34 16 33 00 - Fax +33 (0)1 39 59 85 20 - www.diconex.fr
Edition 6.1
217