TS 971 Automatic control panel DES / NES

Transcription

TS 971 Automatic control panel DES / NES
TS 971
Automatic control panel DES / NES
TS 971
Approvals and certificates
Control panel
TS 971
Compatible limit switches
DES / NES
Dimensiones (WxHxD)
mm
155 x 380 x 80
Power supply
VAC
1~ 190-230
3~ 190-400
Operating frequency
Hz
50 / 60
Max output power
kW
3,0
External supply voltage DC
VDC
A
24
0,35
External supply voltage AC
VAC
A
230
1,6
Control inputs
VDC
mA
24
10 typ.
Controller power input
VA
10
Operating temperature
°C
-5 / +40
Air humidity
%
90 (noncondensing)
Protection class
IP
65 (54)
VAC
A
2 changeover,
potential-free
230
1,0
TS 971
Type test according to:
DIN EN 12453
DIN EN 12978
DIN EN 60335-1
Relay contacts
DIN EN 60335-2-103
DIN EN ISO 13849-1
TÜV NORD CERT GmbH
N
E
S
Connectable accessories
24 V
External
D
E
S
With intergrated
U Universal
B Command sensor
S System
230 V
1~ 190-230V
3~ 190-400V
External
GfA-Gesellschaft für Antriebstechnik
Dr.-Ing. Hammann GmbH & Co.KG
Wiesenstraße 81
40549 Düsseldorf / Germany
+49 (0) 211-500 900
+49 (0) 211-500 90 90
[email protected]
www.gfa-elektromaten.de
Subject to
alterations.
(02.2012_Aa)
NEW features
Universal power supply (190 - 440VAC ~, 350mA)
Safe reversing contactor
(with second independent disconnection facility)
Two relay contacts (independently programmable)
Integrated radio receiver (433 MHz)
Integrated radio transmission system,
Wireless safety device (WSD)
Two UBS inputs
DES and NES processing
(compatible with TS 961 and TS 970)
Plugin power feed
(optional main-switch assembly kit)
Connecting cable installed from above or below
Keypad illumination
NEW software features
Rotation direction change via keypad
Dead man mode with active sensitive edge
Separately adjustable switch positions
for relay contacts
Max number of safety edge actuations
for auto time closure adjustable
Various command devices for
partial opening
Accessories
2
1
Identical enhanced functions for both relays:
• Green light
• Light switch function
• Cam switch contact
• Ramp enable
• Test output for external safety device
Flexible setting for force monitoring in upwards
direction (for fully balanced doors)
Configurable sensitive edge reversing time
Choice of different radio transmitters (various
manufacturers)
Finer differentiation of status messages
Display of last 6 status messages
The operating sequences and the controller
configuration can be read out with a service software
for simplified analyses and troubleshooting (readout
adapter and software available separately).
All other familiar TS 970 functions and the menu
structure have been adopted unchanged.
1
2
3
4
3
1 Emergency stop
2 Key switch
3 Toggle switch for
intermediate
stop setting
4 Main switch
4
Terminal assignment
GfA-Gesellschaft für Antriebstechnik
Dr.-Ing. Hammann GmbH & Co.KG
Wiesenstraße 81
40549 Düsseldorf / Germany
+49 (0) 211-500 900
+49 (0) 211-500 90 90
Pos.
Description
Pos.
Description
DES /
NES
DES or NES limit
switch connector
X1
Power supply
F1
1.5 A fine wire
slow blow fuse
X2
Safety edge and safety
switch for door
MOT
Motor connector
X3
E-STOP command device
S
Selector switch
X4
Auto time closure
ON / OFF
S11
OPEN button
X5
External push buttons
S12
STOP button
X6
One way or
reflection photocell
S13
CLOSE button
X7
Radio receiver /
Ceiling pull switch
T
Radio receiver aerial
X8
Partial opening ON / OFF
UBS
Universal bus sensor
(UCS) connector
X20
Potential free
relay contact 1
V1
Display
X21
Potential free
relay contact 2
X
24 V supply to
external devices
[email protected]
www.gfa-elektromaten.de
Subject to
alterations.
(02.2012_Aa)

Documents pareils